• Title/Summary/Keyword: National Disaster Disaster Protection

Search Result 254, Processing Time 0.029 seconds

Improvement plan and factual survey for weirs, drop structures and bridges in medium scale streams of Kyonggi province (경기도 지방하천에서의 보, 낙차공 및 교량 시설물의 실태 및 개선 방안 제시)

  • Noh, Huiseong;Ahn, Taejin
    • Journal of Wetlands Research
    • /
    • v.22 no.1
    • /
    • pp.31-38
    • /
    • 2020
  • Weirs are to secure amount water of streams and drop structures are to enhance stabilization of stream bed and bridges are to connect isolated region, which are called stream crossing structures. In the stream design criteria, directions for minimum size of structures are suggested to secure stability of stream crossing structures. However the sizes of almost all existing weirs and drop structures are not satisfied with the stream design criteria and only 22 percent of the peirs of bridges are satisfied. To enhance hydraulic stability of existing weirs and drop structures, it is required that the ratio of bed protection to apron should be above 3.3. According to factual survey of structures in the sample streams, it has been shown that the longitudinal slope of rapid works with 1:20 is the most reasonable to design velocity if existing weirs and drop structures are rehabilitated into rapid works. It has been known that violating freeboard and span length of piers should make existing bridges reconstructed or removed. However, comprehensive review including deterioration level of bridges, special regulation for span length, etc. should be considered to determine rehabilitation plan of bridges. In this study, a procedure has been suggested to improve hydraulic stability of weirs, drop structures and piers of bridges. Sound environment of stream and reduction of natural disaster could be achieved by improving stability of cross structures, which could be obtained by governmental budget and active stream management including observance of design criteria.

A Study on B Class Fire Extinguishing Performance of Air Ratio in the Compressed Air Foam System (압축공기포 소화설비의 공기포비에 따른 B급 소화성능 연구)

  • Lee, Jang-Won;Lim, Woo-Sub;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.27 no.6
    • /
    • pp.8-14
    • /
    • 2013
  • This research is to evaluate the fire extinguishing performance at a mixing ratio of pressurized air in the fire extinguishing system of compressed air foam (CAF) which injects compressed air into foam liquid and then discharging. The experimental device is made use of exclusive foam extinguishing facility for compressed air foam that is produces based on Canada National Laboratory and UL 162 standard, apply model of oil fire (B Class) 20 unit in accordance with "Standard of Model Approval and Product Inspection for Fire Extinguishing Agent" to the fire Extinguishing model. Compressed air is injected through the air mixture and study the tendency depending on increasing air foam ratio 1 : 4, 1 : 7, 1 : 10. In addition, the comparison experiments between synthetic surfactants foam and AFFF carry out with it at the air foam ratio 1 : 4. As a result, in the condition of same discharging flow, fire extinguishing effect of AFFF is the fastest at the air foam ratio 1 : 7 and the slowest at 1 : 10. Moreover, the fire extinguishing effect of AFFF in the comparison expeiments between AFFF and synthetic surfactants foam is faster than the other.

A Study on the Fire Prevention Activities and Suppression Measures of Utility-Pipe Conduit (지하공동구 화재예방활동 및 진압대책에 관한 연구)

  • Lee, Jung-Il
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.4
    • /
    • pp.63-68
    • /
    • 2010
  • Utility-Pipe Conduit is, Housing and city effectively accommodate what they absolutely need power, communications, gas, pipeline, water supply, drainage, energy facilities etc, according to expansion of urban infrastructure are derived, several ways to solve problems in, collection facilities in place are maintained and managed facility. If Utility-Pipe Conduit is damaged, as well as national security, because their impact on society as a whole, by introducing large vulnerability in the fire prevention activities and suppression measures and disaster for our situation by introducing measures, comprehensive analysis of the fire risk, it shall establish fire prevention activities and suppression through analysis of Utility-Pipe Conduit design, institutional issues, the problem of fire protection facilities, fire spread phenomenon etc. Because of Utility-Pipe Conduit is an enclosed place, so incomplete combustion due to lack of oxygen supply that there are problem such dark smoke, carbon monoxide etc, toxic combustion products and heat generation and visual impairment is an issue difficult to enter. As well as fire prevention activities, the fire In light of the particularity of the under ground than above ground fire, so this phenomenon is weak fire fighting that fire to become effective fire fighting tactics, basically it is necessary difficulty softening, non-burn softening and prevent combustion expansion of the cable is installed on the Utility-Pipe Conduit, having to considering the specificity of the response command system and relevant organizations to establish an on-site, Structural identification and other information gathering required to record of Response agencies, keep air conditioning system 24 hours and strengthening Virtual Total Training of Response agen

Estimation of Flood Risk Index for the Nakdong River Watershed (낙동강 유역의 홍수위험지수 산정)

  • Song, Jae Ha;Kim, Sangdan;Park, Moo Jong;Choi, Hyun Il
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.1
    • /
    • pp.35-45
    • /
    • 2013
  • The aim of study is to present how to estimate and use the FRI (Flood Risk Index) for classifying area zones based on regional flooding risk in terms of the integrated flood risk management. To estimate the FRI at a spatial resolution of city/county/town units for the Nakdong River Watershed, the 17 representative flood indexing factors are carefully selected for the three flood indexes, such as PI (Pressure Index), SI (State Index), and RI (Response Index) under the P-S-R (Pressure-State-Response) classification system. Because flood indexing factors are measured at different scales and units, they are transformed into a common domain by the T-Score normalization technique. The entropy weight coefficient method is also applied to calculate the weight of flood indexing factors in order to reduce subjective judgement on the effect of weight coefficients. The three flood indexes of PI, SI, and RI are integrated for an overall value of the FRI to evaluate the flood risk of districts. To examine the practical application of the proposed FRI, the FRI results with/without the weight coefficients are compared with flooding zones of natural disaster risk areas officially announced in 2010. It is expected that the FRI ensured by full verification can make regional protection plans against flooding disasters with respect to causes and characteristics of past floods.

Effects of NaCl/H3PO4 Flame Retardant Treatment on Lyocell Fiber for Thermal Stability and Anti-oxidation Properties (NaCl/H3PO4 내염화 처리가 라이오셀 섬유의 열 안정 및 내산화 특성에 미치는 영향)

  • Kim, Eun Ae;Bai, Byong Chol;Jeon, Young-Pyo;Lee, Chul Wee;Lee, Young-Seak;In, Se Jin;Im, Ji Sun
    • Applied Chemistry for Engineering
    • /
    • v.25 no.4
    • /
    • pp.418-424
    • /
    • 2014
  • The improved thermal stability and anti-oxidation properties of Lyocell fiber were studied based on flame retardant treatment by using NaCl/$H_3PO_4$ solution. The optimized conditions of flame retardant treatment were studied on various maxing ratio of NaCl and $H_3PO_4$ and the mechanism was proposed through experimental results of thermal stability anti-oxidation. The IPDT (integral procedural decomposition temperature), LOI (limited oxygen index) and $E_a$ (activation energy) increased 23, 30 and 24% respectively via flame retardant treatment. It is noted that thermal stability and anti-oxidation improved based on char and carbon layer formation by dehydrogenation and dissociation of C-C bond resulting the hindrance of oxygen and heat energy into polymer resin. The optimized conditions for efficient flame retardant property of Lyocell fiber were provided using NaCl/$H_3PO_4$ solution and the mechanism was also studied based on experimental results such as IDT (initial decomposition temperature), IPDT, LOI and $E_a$.

A Study on Application of the UAV in Korea for Integrated Operation with Spatial Information (무인항공기(UAV)의 공간정보 통합운영을 위한 국내적용 방안)

  • Yun, Bu Yeol;Lee, Jae One
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.22 no.2
    • /
    • pp.3-9
    • /
    • 2014
  • With broadcasting telecommunication, rapid change detection, and construction of spatial information, a long reconnaissance, resources detection in dangerous area and natural disasters, which are difficult for manned aerial vehicles to perform, international recognition in UAV merely being used for limited military purposes has been changed and its demand for both civil and military purpose have been increased. However, considering the current situation that availability of UAV varies and its working areas also broaden, the stability of UAV and the problems of privacy protection are more important in integrated operation of UAV. In particular, the application of UAV system is urgent for the area where rapid decision making due to expedite data construction such as disaster, calamity, and the acquisition of spatial information for small area are required. However, since technical stability for UAV system and institutional regulation in regard of spatial information are not examined, and UAV system has not been integrated with aerial photograph, the limitation of UAV system has been presented. Thus, this study is aimed at analyzing domestic and foreign research trend and institutional research trend in terms of integrated UAV operation, and proposing its implications and the availability of integrated UAV operation for future national spatial information data construction.

A Study of a Heat Flux Mapping Procedure to Overcome the Limitation of Heat Flux Gauges in Fire Tests (화재실험시 열유속 센서 사용의 단점을 보완한 Heat Flux Mapping Procedure에 관한 연구)

  • Choi, Keum-Ran
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.4 s.72
    • /
    • pp.171-179
    • /
    • 2005
  • It is essential to understand the role of wall lining materials when they are exposed to a fire from an ignition source. Full-scale test methods permit an assessment of the performance of a wall lining material. Fire growth models have been developed due to the costly expense associated with full-scale testing. The models require heat flux maps from the ignition burner flame as input data. Work to date was impeded by a lack of detailed spatial characterization of the heat flux maps due to the use of limited instrumentation. To increase the power of fire modeling, accurate and detailed heat flux maps from the ignition burner are essential. High level spatial resolution for surface temperature can be provided from an infrared camera. The objective of this study was to develop a heat flux mapping procedure for a room test burner flame to a wall configuration with surface temperature information taken from an infrared camera. A prototype experiment was performed using the ISO 9705 test burner to demonstrate the developed heat flux mapping procedure. The results of the experiment allow the heat flux and spatial resolutions of the method to be determined and compared to the methods currently available.

A Study on the Awareness of Firefighters on the Introduction of Drones and the Operation and Application of drones - Focusing on the Firefighters of Jeollanam-do (소방드론 도입에 따른 소방공무원의 인식과 드론의 운용 및 활용에 대한 연구 - 전라남도 소방공무원을 중심으로)

  • Ha, Kang Hun;Kim, Jae Ho;Choi, Jae Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.6
    • /
    • pp.332-340
    • /
    • 2021
  • The purpose of this study was to present a method for the application of drones through analysis after surveying Jeollanam-do firefighters regarding the recognition, operation, field of application, necessary field of work, and the need for education on fire drones. As a result of the survey, 80.29% of respondents were found to be willing to operate drones, and the fields of work for which drones were considered the most necessary were in the order of rescue, fire suppression, life safety, first aid, and others. Besides, 77.38% of respondents thought that drones could contribute to the prevention of safety accidents for firefighters, and 70.13% of respondents thought that it would be appropriate to recruit firefighting drone operators through changing positions, and respondents chose firefighters in their 40s as the most suitable age group for firefighting drone operation. Also, 82.84% of respondents said they would participate in drone training, and they recognized that the use of drones could contribute to solving the physical problems caused by the aging of firefighters, and that drone training would also help firefighters manage their retirement. The fields where firefighting drones are used were investigated in the order of searching for requestors, checking on-site information, and checking on-site prior risk. In this study, a difference analysis for each group was performed according to the drone operation experience. There was a statistically significant difference in the items of safety measures for requestors. The results of variance analysis by work experience confirmed that there were statistically significant differences in a total of eight items, including four items related to the field of use of drones, and the age group of the drone operating crew, and whether or not to help retirement management.

A study on the degree of aging recognition of firefighters and countermeasures(focus on firefighters in Jeollanam-do) (소방공무원의 고령화 인식정도와 대응방안에 관한 연구(전라남도 소방공무원을 중심으로))

  • Ha, Kang Hun;Kim, Jae Ho;Choi, Jae Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.3
    • /
    • pp.398-407
    • /
    • 2021
  • Firefighters (who are responsible for people's safety) have one of the jobs that are expected to have problems due to aging in the workforce. An increase in the average age of firefighters can lead to serious social problems. The aim of this study is to survey firefighters in Jeollanam-do about their awareness of aging in firefighters, and to propose a plan to prepare them for aging through investigation and analysis of work problems that may occur due to an aging workforce. The survey shows that the higher the age group, the higher the awareness of aging firefighters, and the higher the total work experience and internal/external work experience, the higher the awareness of aging. As a plan to solve various problems that may arise from aging in firefighters, regular operation of physical fitness promotion programs, field work, job rotation, and managerial measures (such as a change of position to an administrative department) are prepared, and drone or robot technology is used. These solutions include the introduction of applied high-tech technologies to firefighting activities, establishment of retirement management policies, and preparation of plans to revitalize the connection to private employment. In order to maximize the applicability of the field, government institutional plans and preparations are essential.

A Study on Flood Susceptibility of Heritage Sites by Heritage Type Depending on Locational Characteristics (입지특성에 따른 문화재 유형별 홍수 민감성 기초연구)

  • Kim, Ji-Soo
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.40 no.3
    • /
    • pp.46-56
    • /
    • 2022
  • This study aimed to analyze the locational characteristics of heritage sites in Seoul in order to identify flood susceptibility by type. As for the location factors related to flood susceptibility, elevation, slope, distance to streams, and topographic location were analyzed. Literature review was supplemented for the historical and humanistic environments of heritage sites. The results of the study are as follows. First, heritage sites in Seoul are distributed throughout the city, and are especially highly dense in the Hanyangdoseong fortress. It was also confirmed that heritage sites were concentrated around Jung-gu, Jongno-gu, Jingwan-dong, and Ui-dong in the quantitative spatial analyses. Second, types of heritage sites at the circumstance susceptible to flood damage were related to commerce and distribution, traffic, modern traffic and communication, geological monument, residence, government office, and palace. Third, heritage types with locational characteristics that showed low flood susceptibility were found to be natural scenic spots, telecommunication, ceramics, Buddhism, tombs, and tomb sculptural heritage assets. In a time when risk factors that can damage the value of heritage are gradually increasing due to anthropogenic influences along with changes in the natural environment, this study provides basic data for vulnerability analysis that reflects the unique characteristics of heritage assets. The results can contribute to more comprehensive and comprehensive insights for the management and protection of heritage by including the humanities and social science data together with natural factors in the analysis.