Optimization of Transient Stability Control Part-I: For Cases with Identical Unstable Modes

  • Xue Yusheng;Li Wei;Hill David John
    • International Journal of Control, Automation, and Systems
    • /
    • v.3 no.spc2
    • /
    • pp.334-340
    • /
    • 2005
  • Based on the stability margin provided by the EEAC, the unstable contingencies can be classified into sets according to their unstable modes. This two-part paper develops a globally optimal algorithm for transient stability control to coordinate preventive actions and emergency actions. In the first part, an algorithm is proposed for a set of contingencies having identical unstable modes. Instead of iterations between discrete emergency actions and continuous preventive actions, the algorithm straightforwardly searches for a globally optimal solution. The procedure includes assessing a set of insufficient emergency schemes identified by the EEAC; calculating the related preventive actions needed for stabilizing the system; and selecting the scheme with the minimum overall costs. Simulations on a Chinese power system highlight its excellent performance. The positive results obtained are explained by analogizing settlements for 0-1 knapsack problems using the multi-points greedy algorithm.

Digital Control for Takagi-Sugeno Fuzzy System with Multirate Sampling

  • Kim, Do Wan;Joo, Young Hoon;Park, Jin Bae
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.4 no.2
    • /
    • pp.199-204
    • /
    • 2004
  • In this paper, a new dual-rate digital control technique for the Takagi-Sugeno (T-S) fuzzy system is suggested. The proposed method takes account of the stabilizablity of the discrete-time T-S fuzzy system at the fast-rate sampling points. Our main idea is to utilize the lifted control input. The proposed approach is to obtain the dual-rate discrete-time T-S fuzzy system by discretizing the overall dynamics of the T-S fuzzy system with the lifted control, and then to derive the sufficient conditions for the stabilization in the sense of the Lyapunov asymptotic stability for this system. An example is provided for showing the feasibility of the proposed discretization method.

A Study on Wavelet Application for Signal Analysis (신호 해석을 위한 웨이브렛 응용에 관한 연구)

  • Bae, Sang-Bum;Ryu, Ji-Goo;Kim, Nam-Ho
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2005.11a
    • /
    • pp.302-305
    • /
    • 2005
  • Recently, many methods to analyze signal have been proposed and representative methods are the Fourier transform and wavelet transform. In these methods, the Fourier transform represents signal with combination cosine and sine at all locations in the frequency domain. However, it doesn't provide time information that particular frequency occurs in signal and denpends on only the global feature of the signal. So, to improve these points the wavelet transform which is capable of multiresolution analysis has been applied to many fields such as speech processing, image processing and computer vision. And the wavelet transform, which uses changing window according to scale parameter, presents time-frequency localization. In this paper, we proposed a new approach using a wavelet of cosine and sine type and analyzed features of signal in a limited point of frequency-time plane.

  • PDF

A Study on the Bit-slice Signal Processor for the Biological Signal Processing (생체 신호처리용 Bit-slice Signal Processor에 관한 연구)

  • Kim, Yeong-Ho;Kim, Dong-Rok;Min, Byeong-Gu
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.15-22
    • /
    • 1985
  • We have developed a microprogramir!able signal processor for real-time ultrasonic signal processing. Processing speed was increased by the parallelism in horizontal microprogram using 104bits microcode and the Pipelined architecture. Control unit of the signal processor was designed by microprogrammed architec- ture and writable control store (WCS) which was interfaced with host computer, APPLE- ll . This enables the processor to develop and simulate various digital signal processing algorithms. The performance of the processor was evaluated by the Fast Fourier Transform (FFT) program. The execution time to perform 16 bit 1024 points complex FF7, radix-2 DIT algorithm, was about 175 msec with IMHz master Clock. We can use this processor to Bevelop more efficient signal processing algorithms on the biological signal processing.

  • PDF

MATHEMATICAL ANALYSIS OF A THREE-SPECIES HOST-PARASITOID-HYPERPARASITOID

  • LIJIAO JIA;YUNIL ROH;IL HYO JUNG
    • East Asian mathematical journal
    • /
    • v.40 no.5
    • /
    • pp.507-514
    • /
    • 2024
  • This study investigated a new three-species host-parasitoid-hyperparasitoid system, which considers the mutual interference functional response. We establish the existence and uniqueness of positive equilibrium points and demonstrate that the presence of hyperparasitoids always leads to an increase in the level of host population equilibrium. In addition, we demonstrate that the quest constant b of hyperparasitoids is proportional to the host equilibrium level, which is critical for the efficiency of biological control programs. We provide parametric conditions for the local stability of the proposed system. Some numerical simulations are performed to validate our theoretical results.

Infection Control practices in accordance characteristic of Dental institutions -Daegu and North Gyeongsang Province around- (치과의료기관의 특성에 따른 감염관리실태 -대구, 경북지역을 중심으로-)

  • Sung, Mi-Ae;Yoon, Sung-Uk
    • Journal of Digital Convergence
    • /
    • v.16 no.5
    • /
    • pp.299-307
    • /
    • 2018
  • This study survey research of infection control, wastewater management, and instrument disinfection according to characteristic at Daegu, Gyeongbuk Province In 2012 and 2017, the same 114 dental clinics to identify the infection management behavior and prevent infection of dental medical institutions. Scored mean 3.37 points on 8 items of infection control, 95.5% in "records of the patient's medical history", 1.8% in "presence of a wastewater facility." Scored 94.7% in "disinfection of metal trays", 17.5% in "storage from a spitting receptacle in the waste bin and commissioned management.", Scored higher in of infection control, wastewater management and instrument disinfection according to general characteristics and dental characteristics in 2017 than in 2012. Points were higher dental hygienist, University graduation, Type of duty was counseling and management, hospital or higher, Number of dentist(dental hygienist, chair, patient) was high. Therefore raise a need for infection control into consideration the dental characteristics and education and promotion regardless of the hospital size.

Liquid Level System Realizing Van de Vusse Reactor Dynamics and its Control Experiments (Van de Vusse 반응기 동특성을 구현하는 액위시스템 및 제어 실험)

  • Lee, Jietae
    • Korean Chemical Engineering Research
    • /
    • v.58 no.2
    • /
    • pp.184-189
    • /
    • 2020
  • Van de Vusse reactors show the maximum points in input-output steady state maps and dramatic changes in their dynamic characteristics around those maximum points. According to their operating regions, there appear sign changes in steady state gains and nonlinear characteristics such as non-minimum phase dynamics which cause difficulties in applying controllers. Many nonlinear controllers that are available and newly designed are applied to these Van de Vusse reactor processes and their performances are tested. Reactor examples with real reactions have been reported. However, due to difficulties in constructing and operating chemical reactor systems, they are not adequate to be used for real applications of control experiments and hence most of results are based on simulations studies. Here, we propose a liquid level system that realizes most of the steady state and dynamic characteristics of Van de Vusse reactor, and two nonlinear control methods that can be used as base methods to compare nonlinear controllers newly designed. Liquid level experimental system and two nonlinear control methods are very simple and can be used to test performances of nonlinear controllers in practice.

A Study on the Application of the Curvature Theory of Ruled Surfaces for the Development of Five-Axis NC Machine Real-Time Control Algorithm (5축 NC 기계의 실시간 제어기법 개발을 위한 룰드 서피스 곡률 이론의 적용 연구)

  • Kim, Jae-Hui;Yu, Beom-Sang
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.1 s.173
    • /
    • pp.182-189
    • /
    • 2000
  • This paper presents the real time control method of 5-axis NC machine for high precision and productivity based on the curvature theory, of a ruled surface. The trajectory, of NC machine is described by, way of a ruled surface generated by the points on part surface and tool axis direction vector. The curvature theory, of a ruled surface is then applied to deter-mine the motion parameters of the 5-axis machine for control. The controller computes position, orientation, and differential motion parameters of the tool in each sampling period. The real-time approach produces smoother surfaces and requires substantially less machining time compared to conventional off-line approaches. The propose real-time control method based of the curvature theory of a ruled surface may give new methodology of precision 5-axis machine control.

Analysis of Critical Control Points through Field Assessment of Sanitation Management Practices in Foodservice Establishments (현장실사를 통한 급식유헝별 위생관리실태 분석)

  • Kwak Tong-Kyung;Lee Kyung-Mi;Chang Hye-Ja;Kang Yong-Jae;Hong Wan-Soo;Moon Hye-Kyung
    • Korean journal of food and cookery science
    • /
    • v.21 no.3 s.87
    • /
    • pp.290-300
    • /
    • 2005
  • Increased sanitation management of foodservice establishments is required because most of the reported foodborne-disease outbreaks were in the foodservice industry. The purpose of this study was to determine the important control points for good sanitation. In this study, we inspected twenty foodservice establishments in Seoul, Kyunggi, Kyungnam with a self-developed monitoring tool. These foodservice establishments included secondary schools, universities, and industries. Six of them had appointed as the HACCP-certified establishments from the Korea Food and Drug Administration. The inspection was conducted from June to August in 2002. The inspection tool consisted of nine dimensions and sixty-five items. The dimensions were 'personal sanitation', 'supply of raw food', 'food storage', 'handling of raw food and ready-to-eat', 'cleaning and sterilization', 'waste control', 'pest control', and 'control of establishment and equipment' The highest possible score of this inspection tool is 105 points. Statistical data analysis was completed using the SPSS Package(11.0) for descriptive analysis Kruskal-Wallis. The score for the secondary schools (83.6 points) was higher than for the others and number of in compliance item was 50.9 on average. Therefore, we concluded that the secondary schools' sanitation condition was good. The foodservice establishments acquired HACCP certification was 89.7 points, which was significantly higher than that of establishments not applying foodservices in total score. Instituting the HACCP system in a foodservice is very effective for sanitation management. Many out of the compliance observations were found in the dimensions of 'waste control', 'control of establishment and equipment', and 'supply of raw food' 'Clean condition of refrigerator' item was $65\%$ out of the compliance that was the highest percent in this study. 'Notify and observance of heating/reheating temperature' was $45\%$ out of compliance. Items which were over $30\%$ out of compliance were 'sterilization of knifes and chopping boards in cooking', 'education of workers', 'maintain refrigerator temperature blow $5^{\circ}C$', and 'countermeasure of infection workers' In the results, most of the foodservice establishments were poorly managed in temperature control and cross-contamination. The important control points revealed in this study were preventing contamination, cooking temperature compliance, management of raw food and refrigerator. Therefore foodservice establishments should pay attention to education and training about important control points. The systematic sanitation management monitoring tool developed in this study can be effectively applied for conducting self-inspection and improving the sanitary conditions of their own foodservice operations.

OPTIMAL SHAPE DESIGN OF THE FRONT WHEEL LOWER CONTROL ARM CONSIDERING DYNAMIC EFFECTS

  • Kang, B.J.;Sin, H.C.;Kim, J.H.
    • International Journal of Automotive Technology
    • /
    • v.8 no.3
    • /
    • pp.309-317
    • /
    • 2007
  • In this study, we conducted a vibration fatigue analysis of the lower control arm in a vehicle suspension system. The vehicle was driven during the tests so that the dynamic effects could be taken into account. The dynamic load of the frequency domain was superimposed on the frequency response analysis. We performed a virtual proving ground test using multi-body dynamics, along with a finite element analysis and fatigue life predictions. Shape optimization was also considered using the design of the experimental approach, and a response surface analysis was performed to improve the durability performance of the lower control arm. We identified the elements that had the most influence on the optimal shape of the finite element model and analyzed the sensitivity of those elements. Then the optimal points that minimized the amount of damage to the areas of interest were determined through a response surface analysis. The results suggested that the fatigue life of the model increased as its mass was not increased excessively, and demonstrated that these design procedures yielded an appropriate optimized lower control arm model.