• Title/Summary/Keyword: National Artifact

Search Result 283, Processing Time 0.029 seconds

Metal artifact SUV estimation by using attenuation correction image and non attenuation correction image in PET-CT (PET-CT에서 감쇠보정 영상과 비감쇠보정 영상을 통한 Metal Artifact 보정에 대한 고찰)

  • Kim, June;Kim, Jae-II;Lee, Hong-Jae;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.21-26
    • /
    • 2016
  • Purpose Because of many advantages, PET-CT Scanners generally use CT Data for attenuation correction. By using CT based attenuation correction, we can get anatomical information, reduce scan time and make more accurate correction of attenuation. However in case metal artifact occurred during CT scan, CT-based attenuation correction can induce artifacts and quantitative errors that can affect the PET images. Therefore this study infers true SUV of metal artifact region from attenuation corrected image count -to- non attenuation corrected image count ratio. Materials and Methods Micro phantom inserted $^{18}F-FDG$ 4mCi was used for phantom test and Biograph mCT S(40) is used for medical test equipment. We generated metal artifact in micro phantom by using metal. Then we acquired both metal artifact region of correction factor and non metal artifact region of correction factor by using attenuation correction image count -to- non attenuation correction image count ratio. In case of clinical image, we reconstructed both attenuation corrected images and non attenuation corrected images of 10 normal patient($66{\pm}15age$) who examined PET-CT scan in SNUH. After that, we standardize several organs of correction factor by using attenuation corrected image count -to- non attenuation corrected count ratio. Then we figured out metal artifact region of correction factor by using metal artifact region of attenuation corrected image count -to- non attenuation corrected count ratio And we compared standard organs correction factor with metal artifact region correction factor. Results according to phantom test results, metal artifact induce overestimation of correction factor so metal artifact region of correction factors are 12% bigger than the non metal artifact region of correction factors. in case of clinical test, correction factor of organs with high CT number(>1000) is $8{\pm}0.5%$, correction factor of organs with CT number similar to soft tissue is $6{\pm}2%$ and correction factor of organs with low CT number(-100>) is $3{\pm}1%$. Also metal artifact correction factors are 20% bigger than soft tissue correction factors which didn't happened metal artifact. Conclusion metal artifact lead to overestimation of attenuation coefficient. because of that, SUV of metal artifact region is overestimated. Thus for more accurate quantitative evaluation, using attenuation correction image count -to-non attenuation correction image count ratio is one of the methods to reduce metal artifact affect.

  • PDF

The Removal of Trembling Artifacts for FORMOSAT-2

  • Chang Li-Hsueh;Wu Shun-Chi;Cheng Hsin-Huei;Chen Nai-Yu
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.142-145
    • /
    • 2005
  • Since the successful launch of FORMOSAT -2 satellite by National Space Organization of Taiwan in May 2004, the Remote Sensing Instrument (RSI) on- board the FORMOSAT -2 has continuously acquired images at one panchromatic and four multi-spectral bands (http://www.nspo.org.tw). In general, the RSI performs well and receives high quality images which proved to be very useful for various applications. However, some RSI panchromatic products exhibit obvious trembling artifact that must be removed. Preliminary study reveals that the trembling artifact is caused by the instability of the spacecraft attitude. Though the magnitude of this artifact is actually less than half of a pixel, it affects the applicability of panchromatic products. A procedure removing this artifact is therefore needed for providing image products of consistent quality. Due to the nature of trembling artifact, it is impossible to describe the trembling amount by employing an analytic model. Relied only on image itself, an algorithm determining trembling amount and removing accordingly the trembling artifact is proposed. The algorithm consists of 3 stages. First, a cross-correlation based scheme is used to measure the relative shift between adjacent scan lines. Follows, the trembling amount is estimated from the measured value. For this purpose, the Fourier transform is utilized to characterize random shifts in frequency domain. An adaptive estimation method is then applied to deduce the approximate trembling amount. In the subsequent stage, image re-sampling operation is applied to restore the trembling-free product. Experimental results show that by applying the proposed algorithm, the unpleasant trembling artifact is no longer evident.

  • PDF

Comparison of Blooming Artifact Reduction Using Image Segmentation Method in CT Image (CT영상에서 이미지 분할기법을 적용한 Blooming Artifact Reduction 비교 연구)

  • Kim, Jung-Hun;Park, Ji-Eun;Park, Yu-Jin;Ji, In-Hee;Lee, Jong-Min;Cho, Jin-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.6
    • /
    • pp.295-301
    • /
    • 2017
  • In this study, We subtracted the calcification blooming artifact from MDCT images of coronary atherosclerosis patients and verified their accuracy and usefulness. We performed coronary artery calcification stenosis phantom and a program to subtract calcification blooming artifact by applying 8 different image segmentation method (Otsu, Sobel, Prewitt, Canny, DoG, Region Growing, Gaussian+K-mean clustering, Otsu+DoG). As a result, In the coronary artery calcification stenosis phantom with the lumen region 5 mm the calcification blooming artifact was subtracted in the application of the mixture of Gaussian filtering and K- Clustering algorithm, and the value was close to the actual calcification region. These results may help to accurately diagnose coronary artery calcification stenosis.

Evaluating applicability of metal artifact reduction algorithm for head & neck radiation treatment planning CT (Metal artifact reduction algorithm의 두경부 CT에 대한 적용 가능성 평가)

  • Son, Sang Jun;Park, Jang Pil;Kim, Min Jeong;Yoo, Suk Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.107-114
    • /
    • 2014
  • Purpose : The purpose of this study is evaluation for the applicability of O-MAR(Metal artifact Reduction for Orthopedic Implants)(ver. 3.6.0, Philips, Netherlands) in head & neck radiation treatment planning CT with metal artifact created by dental implant. Materials and Methods : All of the in this study's CT images were scanned by Brilliance Big Bore CT(Philips, Netherlands) at 120kVp, 2mm sliced and Metal artifact reduced by O-MAR. To compare the original and reconstructed CT images worked on RTPS(Eclipse ver 10.0.42, Varian, USA). In order to test the basic performance of the O-MAR, The phantom was made to create metal artifact by dental implant and other phantoms used for without artifact images. To measure a difference of HU in with artifact images and without artifact images, homogeneous phantom and inhomogeneous phantoms were used with cerrobend rods. Each of images were compared a difference of HU in ROIs. And also, 1 case of patient's original CT image applied O-MAR and density corrected CT were evaluated for dose distributions with SNC Patient(Sun Nuclear Co., USA). Results : In cases of head&neck phantom, the difference of dose distibution is appeared 99.8% gamma passing rate(criteria 2 mm / 2%) between original and CT images applied O-MAR. And 98.5% appeared in patient case, among original CT, O-MAR and density corrected CT. The difference of total dose distribution is less than 2% that appeared both phantom and patient case study. Though the dose deviations are little, there are still matters to discuss that the dose deviations are concentrated so locally. In this study, The quality of all images applied O-MAR was improved. Unexpectedly, Increase of max. HU was founded in air cavity of the O-MAR images compare to cavity of the original images and wrong corrections were appeared, too. Conclusion : The result of study assuming restrained case of O-MAR adapted to near skin and low density area, it appeared image distortion and artifact correction simultaneously. In O-MAR CT, air cavity area even turned tissue HU by wrong correction was founded, too. Consequentially, It seems O-MAR algorithm is not perfect to distinguish air cavity and photon starvation artifact. Nevertheless, the differences of HU and dose distribution are not a huge that is not suitable for clinical use. And there are more advantages in clinic for improved quality of CT images and DRRs, precision of contouring OARs or tumors and correcting artifact area. So original and O-MAR CT must be used together in clinic for more accurate treatment plan.

A new algorithm for minimization of metal artifact made on CT by pedicle screws (Pedicle screws에 의해 CT에 생성되는 metal artifact를 최소화하는 알고리즘 개발)

  • Lee, J.B.;Yeom, J.S.;Kim, N.K.;Lee, D.H.;Kim, J.H.;Kim, Y.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.279-280
    • /
    • 1998
  • A new algorithm is developed that can reduce the metal artifact on CT caused by pedicle screws. Metal artifact has been recognized as a major problem in precise reading of CT images. In particular, spine surgeons have been bothered with the artifact appearing on CT taken after pedicle screw insertion. To reduce the artifact, our new algorithm first finds the center line from CT images, and then overlays an exact size screw image on the CT. The exact screw is obtained from an actual design specifications of screw, and the CT images are processed to maximize bone margins while minimizing screw images through adjusting the window width and level. 실험 결과 단순한 Window W/L 조절로는 해결되지 않는군요. This algorithm provides spine surgeons with more accurate CT images and thus better interpretation of CT to ascertain the success or failure of pedicle screw insertion.

  • PDF

Conservation treatment of the sword with round pommel with a tri-ring excavated at Duckcheon-ri Tomb in Gyeongju (경주 덕천리 유적 수습 유물 보존처리-삼두환두대도를 중심으로)

  • Kim, Ji-Young;Seo, Jung-Eun;Ryu, Dong-Wan
    • 보존과학연구
    • /
    • s.26
    • /
    • pp.127-139
    • /
    • 2005
  • We have conserved the sword with round pommel with a tri-ring which was excavated from No. 1 tomb of the Duckcheon-ri at the Gyeongju and requested from Jungang Research Center of the Cultural Heritage. When this artifact excavated, it was pressed flat state because of the influence of earth pressure and stuck to a gravel and soil laid scattered on the wooden coffin. If the artifacts is handled without plan, it can be damaged, therefore that sword was collected together with soil using the Polyurethane foam. After the artifact which had a weak specific and was collected using a this method can be safetly collected as below; First, we made the supporter of article ordered using a silicon and gypsum. The silicon can conserve the weak point of the artifact because it has a flexible and smooth properties and the gypsum can adhere closely to the artifact because it has a little expansion and shrinking but a hard and fluid characters. Consequently, gypsum is a good complement to the weak point of the silicon. Second, During a remove gauze and a reinforcing agent from the surface of a artifact which was reinforced using a acetone steam method. The acetone steam method can be supplement to a dangerous problem of acetonedircet method because this can be damaged in a surface of the artifact.

  • PDF

Robust Design of Pulse Oximeter Using Dynamic Control and Motion Artifact Detection Algorithms

  • Cho, Jung Hyun;Kim, Jong Cheol;Yoon, Gil Won
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.5
    • /
    • pp.1780-1787
    • /
    • 2014
  • Arterial oxygen saturation ($SpO_2$) monitoring for newborns requires special attention in neonatal intensive care units (NICUs). Newborns have very low photo-plethysmogram (PPG) amplitudes and their body movements are difficult to contain. Hardware design and its associated signal processing algorithms should be robust enough so that faulty measurements can be avoided. In this study, improved designs were implemented to deal with low perfusion, motion artifact, and the influence of ambient light. Dynamic range was increased by using different LED intensities and a feedback system. To minimize the effects of motion artifact and to discard other unqualified data, four additional algorithms were used, which were based on dual-trace detection, continuity of DC level, morphology of PPG, and simultaneity check of $SpO_2$. Our $SpO_2$ system was tested with newborns with normal respiration in the NICU. Our system provided fast, real-time responses and 100% artifact detection was accomplished under 84% of $SpO_2$.

Filter-based Correction for Positive Sampling Artifacts in the Determination of Ambient Organic Carbon (여과지를 이용한 유기탄소의 측정 오차 보정)

  • Kang, Byung-Wook;Yeon, Ik-Jun;Cho, Byung-Yeol;Park, Sang-Chan;Lee, Hak-Sung;Jeon, Jun-Min;Na, Kwang-Sam
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.1
    • /
    • pp.63-72
    • /
    • 2011
  • This study describes the impact of positive sampling artifact caused by a filter-based sampling in the determination of ambient organic carbon (OC). Three different sampling media combinations were employed for this investigation: (1) Quartz filter-alone (Q-alone), (2) quartz filter behind quartz-fiber filter (QBQ), and (3) quartz filter and quartz filter behind Teflon filter (Q-QBT). The measurement of ambient OC was carried out at a semi-urban site near oceanside at the end of November of 2008. It was found that Q-alone sampling configuration resulted in a higher OC than QBQ and Q-QBT by 14% and 28%, respectively due to no correction for positive artifact caused by adsorption of gas-phase OC onto the filter. A lower quantity of OC was collected from the backup quartz filter on QBQ than that from Q-QBT. A possible explanation is that the front quartz filter of QBQ was not fully saturated with gas-phase OC during the sampling period, allowing smaller amount of gas-phase OC to reach the backup quartz filter. The contribution of positive artifact to $PM_{2.5}$ mass was approximately 2.15 ${\mu}g/m^3$ which is equivalent to 6% in terms of Q-QBT sampling configuration. The positive artifact was found to be more dominated during summer than during winter, showing temperature dependence. It was concluded that Q-QBT sampling configuration offers less impact of positive artifact on ambient OC sampling than QBQ in quantification of OC.

The study on stability of restoration material of organic artifact (유기질 문화재 복원재료의 재질안정성에 대한 연구)

  • Jeong, Seon-Young;Jeong, So-Young;Jeong, Seon-Hwa;Seo, Jin-Ho
    • 보존과학연구
    • /
    • s.29
    • /
    • pp.5-18
    • /
    • 2008
  • Hanji among paper, which is material for support of the organic artifact such as painting and Thangkas, is given as much importance as the original material in the conservation treatment of artifacts. This lining paper can go through physical and chemical deterioration due to its organic nature, and inflict serious damage to the original materials of the artifact. There is a lot of difficulty in keeping continuous production of the paper mulberry fiber based on lining paper due to a short supply of raw material and discontinuation of traditional method. Also restoration and conservation treatment is done by relying only on the knowledge and skill of few experts without any recognized manual based on scientific analysis. In this study, we evaluated the stability of lining paper which is used to support organic artifact. As the result of experiments, this lining paper was made from mulberry tree in Korea and produced by means of oebal method, but was not treated by starch in its surface.

  • PDF

A Study on the Expanded Description Elements for the Management of National Artifacts (국가행정박물 관리를 위한 기술요소확장에 관한 연구)

  • Kim, Jeong-Sim;Roh, Soo-Jeong;Nam, Young-Joon
    • Journal of Information Management
    • /
    • v.41 no.1
    • /
    • pp.145-172
    • /
    • 2010
  • National artifacts has the same physical characteristics to general artifacts and the evidential value which was produced during the public working. National artifacts different from paper and electronic records about physical properties. So it should be doing the expanded process. In this study, the ISAD(G), MODS, RAD and CDWA based on Korean Record Management Law by comparing and analysing of the technical elements was being extracted, The descriptive elements of national artifacts is pull by conclusion of the analysis.