• Title/Summary/Keyword: Narrow-diameter implant

Search Result 23, Processing Time 0.022 seconds

Titanium-zirconium alloy narrow-diameter implants for the rehabilitation of horizontally deficient mandibular posterior edentulous ridges (좁은 치조제를 가진 하악 구치부에서 지르코늄-티타늄 합금의 작은 직경 임플란트 사용 증례)

  • Lee, In Hye;Park, Young Bum;Han, Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.2
    • /
    • pp.212-217
    • /
    • 2017
  • In case of the insufficient horizontal bone loss, a regular diameter implant is not possible without lateral bone augmentation. In this situation, narrow diameter implants (NDIs) could be the alternative to lateral bone augmentation procedures. However, complication generally expected with the NDI is implant fracture. Recently, the survival rate and success rate of NDI in the posterior region are similar to that of standard-diameter implants (SDIs). These 3 case reports demonstrate the incorporation of NDI to replace missing mandibular posterior teeth. So far, the follow-up examination period was maintained and no unusual complications were presented for more than four years. Long term follow-up clinical data are needed to confirm the excellent clinical performance of these implants.

Survival rate and clinical evaluation of the implants in implant assisted removable partial dentures: surveyed crown and overdenture

  • Kang, Soo-Hyun;Kim, Seong-Kyun;Heo, Seong-Joo;Koak, Jai-Young
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.4
    • /
    • pp.239-249
    • /
    • 2020
  • PURPOSE. The purpose of this study was to investigate survival rates of the implants used in implant assisted removable partial dentures (IARPDs). MATERIALS AND METHODS. The study was conducted on 21 patients who were treated with IARPDs. The mean follow-up period for IARPD patients ranged from 12 to 185 months (mean 47.9 months). A total of 58 implants were used for IARPDs in two different modalities: 41 for surveyed crowns and 17 for overdentures. The survival of implants was determined by clinical and radiographic evaluations considering relevant factors: location, RPD classification, opposing dentition, splinting, and implant diameter. RESULTS. The survival rate of total 58 implants was 93.1%: 95.1% for implants supporting surveyed crowns and 88.2% for implants used in overdentures. Considering only the implants supporting surveyed crown, regular diameter implants showed a higher survival rate than narrow or wide diameter implants. CONCLUSION. The survival rate of the implants used in IARPDs was 93.1% (surveyed crown: 95.1%, overdenture: 88.2%).

Treatment plan for missing mandibular 4 incisors (하악 4전치 상실시 치료 계획)

  • Hahn, Kwang Jin
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.25 no.1
    • /
    • pp.25-34
    • /
    • 2016
  • Treatment of missing mandibular 4 incisors is often thought to be easier then other place during surgical and prothetic procedure. But clinicians encounter unexpected difficulties such as restricted implant site due to mesio-distal width of mandibular incisors, limited space as a result of crowing and mesial drift, esthetic problem after severe alveolar bone resorption, and difficulties of provisionalization Through cases, possible treatment options for missing mandibular incisors would be discussed. Treatment options for missing mandibular 4 incisors Place narrow type implant or one body mini implant on exact tooth position when there is no bone resorption Regular size implant on interseptal bone area when there is severe bone resorption Consider using resin bonded bridge(resin retained bridge/resin bonded fixed partial denture) as a tentative prosthesis when patient resists extracting remaining incisors with poor prognosis.

Mini-implant with additional retentive structure by using digital method (부가적인 유지구조를 가진 미니 임플란트의 디지털 수복 증례)

  • Hwang, Su-Hyun;Bae, Eun-Bin;Cho, Won-Tak;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.1
    • /
    • pp.119-126
    • /
    • 2022
  • Mini-implant has been reported as an alternative method to conventional diameter implants in the treatment of mandibular anterior region with narrow ridge. However, one-piece type mini-implant showed biological and technical complications, such as peri-implantitis by residual cement and prosthetic detachment. Recently, one-piece type mini-implant with additional retentive structure has been introduced to increase the retention and stability of the mini-implant. The mini-implant is based on spreading the upper retentive structure with a spreader and connected it with the inner surface of the zirconia prosthesis. In two cases, we tried to reduce these complications through the mini-implant on the narrow mandibular anterior region, and it was possible to reduce the overall treatment period through a digital system. In this case report, restoration using the digital mini-implant system showed improvement of patient satisfaction on the aspect of function and esthetic in the narrow mandibular anterior region.

Clinical and radiographic assessment of narrow-diameter and regular-diameter implants in the anterior and posterior jaw: 2 to 6 years of follow-up

  • Alrabiah, Mohammed;Deeb, Modhi Al;Alsahhaf, Abdulaziz;AlFawaz, Yasser F.;Al-Aali, Khulud Abdulrahman;Vohra, Fahim;Abduljabbar, Tariq
    • Journal of Periodontal and Implant Science
    • /
    • v.50 no.2
    • /
    • pp.97-105
    • /
    • 2020
  • Purpose: The present retrospective clinical study aimed to evaluate and compare the clinical and radiographic parameters, complications, and satisfaction in patients who received fixed prostheses supported by narrow-diameter implants (NDIs) in the anterior and posterior jaw. Methods: Patients aged ≥30 years who had NDI-supported fixed prostheses in the anterior or posterior region of either jaw for at least 2 years were included. Complications such as chipping of the crown; loosening or fracture of the screw, crown abutment, or implant; and loss of retention were recorded. Clinical peri-implant outcomes and crestal bone loss (CBL) were measured. A questionnaire was used to record responses regarding the aesthetics and function of the fixed restorations. Analysis of variance was used to assess the significance of between-group mean comparisons. The log-rank test was performed to analyze the influence of location and prosthesis type on technical complications. Results: Seventy-one patients (mean age: 39.6 years) provided informed consent with a mean follow-up duration of 53 months. Only bleeding on probing showed a statistically significant difference between NDIs in the anterior and posterior regions. The complication rate for NDIs in the posterior region was significantly higher than that for NDIs in the anterior region (P=0.041). For NDIs, CBL was significantly higher around splinted crowns than single crowns (P=0.022). Overall mean patient satisfaction was 10.34±3.65 on a visual analogue scale. Conclusions: NDIs in the anterior and posterior jaws functioned equally well in terms of periimplant soft and hard tissue health and offered acceptable patient satisfaction and reasonable complication rates.

Multicentric retrospective clinical study on the clinical application of mini implant system (미니 임플란트 시스템의 적용에 대한 다기관 후향적 임상연구)

  • Kim, Young-Kyun;Yeo, In-Sung;Yi, Yang-Jin;Kim, Un-Kyu;Moon, Kyung-Nam;Jeon, Seung-Joon;Cho, Yong-Seok;Yun, Pil-Young
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.36 no.4
    • /
    • pp.325-330
    • /
    • 2010
  • Introduction: Mini-implant system is applicable to areas of narrow space and area requiring temporary loading support. The purpose of this study was to evaluate the clinical outcome of a mini-implant system as well as the application of mini-implant system in the dental clinical field. Materials and Methods: The patients who had been operated from Jan 2007 to Dec 2007 in the four dental facility including Seoul National University Bundang Hospital were enrolled. To evaluate the factors associated with the clinical outcome, the patients were classified according to gender, age, area of surgery, type of implant, diameter and length of the implant, and the purpose of the mini-implant system application. Results: From 147 implants, only three implants failed, one of them was for temporary loading. There were no serious surgical or prosthetic complications in this study. Conclusion: An analysis of the preliminary data revealed a satisfactory clinical outcome. However, more long-term evaluation of narrow ridge type as well as the patient’s satisfaction on the use of a provisional type mini-implant system is needed.

Esthetic restoration in mandibular anterior region with one-piece implant and immediate loading (하악 전치부에서의 일체형 임플란트 식립 후 즉시부하)

  • Yoon, Sena
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.27 no.2
    • /
    • pp.97-104
    • /
    • 2018
  • Mandibular anterior region has high implant survival rates and better accessibility compared with any other region. Even if there are possibilities for perforation on lingual cortical bone due to improper drilling and bleeding caused by lingual artery damage, mandibular anterior region is a safe region because less amount of major anatomical structures exist compared with other regions. However, because of narrow bucco-lingual width of alveolar ridge, it is challengeable to obtain esthetic implant prosthesis. Although patients are less sensitive subjectively, mandibular anterior region is as difficult as maxillary anterior region in that implant placement location plays a critical role on the prognosis of implant prosthesis. One-piece implant is a very useful option for mandibular anterior region. Considering the narrow roots and thin alveolar bone of mandible, it is clinically difficult for implant diameter to be greater than 3mm In this case, we could approach the esthetic restoration in mandibular anterior region with one-piece implant and immediate loading.

Immediate Loading of Narrow Diameter Implants at the Mandibular Incisor Area Using Full Digital Flow: A Case Report

  • Ahn, Ji Ho;Lim, Young-Jun;Baek, Yeon-Wha;Lee, Jungwon
    • Journal of Korean Dental Science
    • /
    • v.15 no.1
    • /
    • pp.92-99
    • /
    • 2022
  • This case report describes the immediate loading of narrow diameter implants in the mandibular incisor area using full-digital flow. The 3-dimensional position of the implants was planned using digital software, and the corresponding surgical template was fabricated. The implants were inserted immediately after extraction and on the same day, the interim abutment and bridge were placed. At 8 weeks after surgery, the stability of the implants was measured and a digital impression was made using a scan body. Customized titanium abutments and a cement-type full zirconia bridge were delivered. At 36 weeks' follow-up, no clinical or radiographic complications were detected, and the patient was satisfied with the results.

A two-short-implant-supported molar restoration in atrophic posterior maxilla: A finite element analysis

  • Song, Ho-Yong;Huh, Yoon-Hyuk;Park, Chan-Jin;Cho, Lee-Ra
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.4
    • /
    • pp.304-312
    • /
    • 2016
  • PURPOSE. The aim of this study was to investigate the stress distribution of 2-short implants (2SIs) installed in a severely atrophic maxillary molar site. MATERIALS AND METHODS. Three different diameters of internal connection implants were modeled: narrow platform (NP), regular platform (RP), and wide platform (WP). The maxillary first molars were restored with one implant or two short implants. Three 2SI models (NP-oblique, NP-vertical, and NP-horizontal) and four single implant models (RP and WP in a centered or cantilevered position) were used. Axial and oblique loadings were applied on the occlusal surface of the crown. The von Mises stress values were measured at the bone-implant, peri-implant bone, and implant/abutment complex. RESULTS. The highest stress distribution at the bone-implant interface and the peri-implant bone was noticed in the RP group, and the lowest stress distribution was observed in the 2SI groups. Cantilevered position showed unfavorable stress distribution with axial loading. 2SI types did not affect the stress distribution in oblique loading. The number and installation positions of the implant, rather than the bone level, influenced the stress distribution of 2SIs. The implant/abutment complex of WP presented the highest stress concentration while that of 2SIs showed the lowest stress concentration. CONCLUSION. 2SIs may be useful for achieving stable stress distribution on the surrounding bone and implant-abutment complex in the atrophic posterior maxilla.

Evaluation of the Availability of Implant placement using Ridge Expansion Osteotomy (REO) (치조능확장골절단술을 이용한 임프란트 식립술의 유용성 평가)

  • Kim, Yeong-Gyun;Yun, Pil-Yeong;Kim, Beom-Su
    • The Journal of the Korean dental association
    • /
    • v.46 no.4
    • /
    • pp.243-247
    • /
    • 2008
  • Purpose : Ridge expansion osteotomy (REO) has been introduced when it is necessary to expand narrow crestal ridge with simultaneous implant placement. This study has designed to evaluate the clinical availability of REO. Materials and methods : Subject were patients who had visited Seoul National University Bundang Hospital from July. 2003 to December, 2005 for implant placement using REO by one surgeon. Intraoperative and postoperative complication, failure of initial osseointegration and marginal bone resorption were estimated using electronic medical record and periapical radiography. Twenty?three patients, 8 males and 15 females, mean age 51, ranged 18 to 72, were treated for mean 26 months, ranged from 16 months to 46 months. Results : Mean diameter and length of implants placed at upper anterior, were 3.72mm and 13.32mm each other. Guided bone regeneration and ridge splitting were accompanied in this study. Five cases of cortical bone fracture, three cases of crestal bone loss more than 2mm, 2cases of gingival recession, and 2 cases of infection were noted, but there were no implants removed because of disintegration. Success rate of implant was 91.7%, even if survival rate of implant was 100%. In addition, there were no statistical significance between the success rate of REO and bone graft(p>0.05). Conclusion : Based on the results of the present study, it can be concluded that REO technique is reliable for implant placement at atrophic ridge with adequate height compared to bone graft and other osteotomies for ridge expansion, but care should be taken of esthetic problem such as gingival recession because of crestal bone resorption from trauma by osteotome.

  • PDF