• Title/Summary/Keyword: Narrow ridge

Search Result 44, Processing Time 0.03 seconds

Radiographic evaluation of marginal bone level alteration around narrow implants placed in narrow alveolar ridge using guided flapless surgery (폭이 좁은 치조골에서 컴퓨터가이드를 이용한 무절개 임플란트 수술로 식립한 narrow implant의 방사선학적 평가)

  • Jeong, Seung-Mi;Choi, Byung-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.4
    • /
    • pp.306-312
    • /
    • 2020
  • Purpose: The aim of this study was to compare radiographic outcomes around narrow-diameter implants placed using guided flapless surgery at longer than 6 month post-placement. Materials and methods: A total of 12 implants were assessed in 12 patients for the sites where 0.5 - 1.5 mm labial bone was covering the implants, using CBCT. Results: A statistically significant preservation of crestal bone was observed in the narrow-diameter implants. Conclusion: Guided flapless implant surgery may be important in preventing bone loss around the narrow-diameter implants that are placed in narrow alveolar ridges.

Evaluation of the Availability of Implant placement using Ridge Expansion Osteotomy (REO) (치조능확장골절단술을 이용한 임프란트 식립술의 유용성 평가)

  • Kim, Yeong-Gyun;Yun, Pil-Yeong;Kim, Beom-Su
    • The Journal of the Korean dental association
    • /
    • v.46 no.4
    • /
    • pp.243-247
    • /
    • 2008
  • Purpose : Ridge expansion osteotomy (REO) has been introduced when it is necessary to expand narrow crestal ridge with simultaneous implant placement. This study has designed to evaluate the clinical availability of REO. Materials and methods : Subject were patients who had visited Seoul National University Bundang Hospital from July. 2003 to December, 2005 for implant placement using REO by one surgeon. Intraoperative and postoperative complication, failure of initial osseointegration and marginal bone resorption were estimated using electronic medical record and periapical radiography. Twenty?three patients, 8 males and 15 females, mean age 51, ranged 18 to 72, were treated for mean 26 months, ranged from 16 months to 46 months. Results : Mean diameter and length of implants placed at upper anterior, were 3.72mm and 13.32mm each other. Guided bone regeneration and ridge splitting were accompanied in this study. Five cases of cortical bone fracture, three cases of crestal bone loss more than 2mm, 2cases of gingival recession, and 2 cases of infection were noted, but there were no implants removed because of disintegration. Success rate of implant was 91.7%, even if survival rate of implant was 100%. In addition, there were no statistical significance between the success rate of REO and bone graft(p>0.05). Conclusion : Based on the results of the present study, it can be concluded that REO technique is reliable for implant placement at atrophic ridge with adequate height compared to bone graft and other osteotomies for ridge expansion, but care should be taken of esthetic problem such as gingival recession because of crestal bone resorption from trauma by osteotome.

  • PDF

Determination of Instantaneous Frequency By Continuous Wavelets Ridge (연속 웨이브렛 Ridge를 이용한 순간주파수 결정)

  • Kim, Tae-Hyung;Yoon, Dong-Han
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.1
    • /
    • pp.8-15
    • /
    • 2005
  • The analysis of Rader signal that have non-linearity variable phase is signal that contact easily in several fields such as radar, telecommunication, seismic, sonar and biomedical applications. In generally, Non-stationary signal means that spectral characteristics are varying with time and instantaneous frequency is only one frequency or narrow range of frequencies varying as a function of time. Therefore, Instantaneous frequency is vary important variable that understanding physical characteristic of signal. This paper was describes continuous wavelet transform to determine instantaneous frequency at non-staionary signal and compare to existing method. When white noise or various frequency is overlapped each other in sign, existing method was can not decide corrected instantaneous frequency, but when used continuous wavelet transform, very well decide correctly frequency regardless of component of signal.

Theoretical and Experimental Investigation on the Probe Design of a Ridge-loaded Slot Type for Near-Field Scanning Microwave Microscope

  • Son, Hyeok-Woo;Kim, Byung-Mun;Hong, Jae-Pyo;Cho, Young-Ki
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.5
    • /
    • pp.2120-2125
    • /
    • 2015
  • In this paper, a rectangular waveguide probe with a ridge-loaded straight slot (RLSS) is presented for a near-field scanning microwave microscope (NSMM). The RLSS is located laterally at the end wall of the cavity and is loaded on double ridges in a narrow straight slot to improve the spatial resolution compared with a straight slot. The probe consists of a rectangular cavity with an RLSS and a feed section of a WR-90 rectangular waveguide. When the proposed NSMM is located at distance of 0.1mm in front of a substrate without patches or strips, the simulated full width at half maximum (FWHM) of the probe improve by approximately 31.5 % compared with that of a straight slot without ridges. One dimensional scanning of the E-plane on a sample under test was conducted, and the reflection coefficient of the near-field scanning probe is presented.

Case report of a newly designed narrow-diameter implant with trapezoid-shape for deficient alveolar bone (좁은 치조골에서 사다리꼴형 디자인으로 개발된 단폭경임플란트의 증례 보고)

  • Lee, Sa Ya;Goh, Mi-Seon;Ko, Seok-Yeong;Yun, Jeong-Ho
    • The Journal of the Korean dental association
    • /
    • v.56 no.5
    • /
    • pp.263-276
    • /
    • 2018
  • Long-term survival and prognosis of narrow-diameter implants have been reported to be adequate to consider them a safe method for treating a deficient alveolar ridge. The objective of this study was to perform case report of narrow-diameter implants with a trapezoid-shape in anterior teeth alveolar bone. A 50-year-old male patient presented with discomfort due to mobility of all of the maxillary teeth and mandibular incisors. Due to destruction of alveolar bone, four anterior mandibular teeth were extracted. Soft tissue healing was allowed for approximately 3 months after the extraction, and a new design of implant placement was planned for the mandibular incisor area, followed by clinical and radiological evaluation. Implant placement was determined using an R2GATE surgical stent. The stability of the implants was assessed by ISQ measurements at the first and second implant surgery and after prosthetic placement. At 1 and 3 months and 1 year after implantation of the prosthesis, clinical and radiological examinations were performed. Another 50-year-old male patient presented with discomfort due to mobility of the mandibular central incisors. For the same reason as in the first patient, implant placement was carried out in the same way after extraction. ISQ measurements and clinical and radiological examinations were performed as in the previous case. In these two clinical cases, 12 months of follow-up revealed that the implant remained stable without inflammation or additional bone loss, and there was no discomfort to the patient. In conclusion, computer-guided implant surgery was used to place an implant in an optimal position considering the upper prosthesis. A new design of a narrow-diameter implant with a trapezoid-shape into anterior mandibular alveolar bone is a less invasive treatment method and is based on the contour of the deficient alveolar ridge. Through all of these procedures, we were able to reduce the number of traumas during surgery, reduce the operation time and total treatment period, and provide patients with more comfortable treatment.

  • PDF

PRELIMINARY STUDY ON "RIDGE SPLITTING TECHNIQUE" IN HORIZONTALLY DEFICIENT ALVEOLAR RIDGE (위축된 치조골에서 치조골 수평 확장술을 이용한 임플란트 이식술에 관한 임상연구)

  • Park, Young-Ju;Nam, Jeong-Hun;Song, Jun-Ho;Yeon, Byung-Moo;Noh, Kyung-Lok;Pang, Eun-O;Chung, Jae-An;Shin, Jin-Eob;Kang, Eung-Seon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.4
    • /
    • pp.314-318
    • /
    • 2009
  • The aim of this study was to evaluate the clinical applicability of a ridge splitting technique for reconstruction of narrowed edentulous alveolar ridges for dental implantation. 41 patients with 47 edentulous areas were included in this study. After corticotomy of a rectangular buccal segment and about 3-4 weeks healing period, the alveolar ridge was splitted, implant was placed. The initial ridge width varied between 2.5 and 7.0mm, average was 3.99mm. 68 dental implants were placed, and the gap between the implants and the bone is filled with various bone graft material, or none. All splitted sites showed sufficient bone volume for insertion of the implants at the moment of implantation. Over 1 year of follow-up period, five implants(7.3%) had mobility in two patients, among them, 2 implants(2.9%) sustained infection and removed. And any other complications were not noted. Our conclussion is that ridge splitting of the narrow edentulous area is a reliable and safe procedure in horizontally deficient ridges.

Responses of Malting Barley Cultivars to Different Seeding Rates I. Variation of Yield Components and Yields in Different Seeding Rates (파종량에 따른 맥주맥의 품종간반응 I. 수량구성요소 및 수량변이)

  • 구자옥;이영만;하기용;신동영
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.29 no.4
    • /
    • pp.409-415
    • /
    • 1984
  • Finding the variations of principal agronomic traits, fourteen malting barley cultivars were tested with both narrow-spaced row seeding and broadcasting on high ridge respectively. The seeding rates were varied as 15, 20, 25, 30 and 35 liter per 10a in the narrow-spaced row seeding and 20, 25, 30, 35, and 40 litre in the broad casting on his ridge respectively. As a result of the test, there were highly significant differences in variation pattern of assessed traits among cultivars. However, the additional seeding rates in both seeding methods caused the drifts of earlier heading and maturity, longer in culm length, linear increase in number of spike and yields per unit area, slight reduction in 1000 grain weight, and slight increase in one litre weight, but no changes in number of grain per spike.

  • PDF

Mini-implant with additional retentive structure by using digital method (부가적인 유지구조를 가진 미니 임플란트의 디지털 수복 증례)

  • Hwang, Su-Hyun;Bae, Eun-Bin;Cho, Won-Tak;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.1
    • /
    • pp.119-126
    • /
    • 2022
  • Mini-implant has been reported as an alternative method to conventional diameter implants in the treatment of mandibular anterior region with narrow ridge. However, one-piece type mini-implant showed biological and technical complications, such as peri-implantitis by residual cement and prosthetic detachment. Recently, one-piece type mini-implant with additional retentive structure has been introduced to increase the retention and stability of the mini-implant. The mini-implant is based on spreading the upper retentive structure with a spreader and connected it with the inner surface of the zirconia prosthesis. In two cases, we tried to reduce these complications through the mini-implant on the narrow mandibular anterior region, and it was possible to reduce the overall treatment period through a digital system. In this case report, restoration using the digital mini-implant system showed improvement of patient satisfaction on the aspect of function and esthetic in the narrow mandibular anterior region.

Description of the Post Larva of Star Pipefish, Halicampus punctatus (Syngnathidae, Gasterosteiformes) First Found in the Southwestern East Sea, Korea

  • Kim, Sung;Lee, Youn-Ho;Oh, Ji-Na
    • Ocean Science Journal
    • /
    • v.41 no.4
    • /
    • pp.201-205
    • /
    • 2006
  • Larval specimens of Halicampus punctatus were collected off Ulsan and Uljin in December 2002 (three specimens) and off Ulsan in December 2003 (one specimen). These specimens are characterized by the following morphological characteristics: rings, 14 + 35 = 49; subdorsal rings, 1 + 3 = 4; dorsal fin rays, 19 - 20; pectoral fin rays, 14 - 15; anal fm rays, 9; head length (HL), 5.8 - 6.7 in the standard length; snout length, 1.9 in HL; snout depth, 3.7 - 5.2 in snout length. The number of caudal fin rays 9 is less than those of the other species in the same genus 10. Wide stripe bands composed of small pigments are shown in the trunk and the tail. Melanophores are not found in the dorsal fin, the pectoral fin, and the anal fin except the caudal fin. The supraoccipital crest is on the head. The frontal ridge is on the dorsal side of front trunk. The blanched ridges on the opercular are fused with a main ridge like a tree branch. A few branched ridges that are small and narrow on the trunk and the tail are fused with the main ridges. We report these specimens as the first record in Korea and name them 'Byeol-sil-go-ki' in Korean.

Hyperspectral Fluorescence Imaging for Mouse Skin Tumor Detection

  • Kong, Seong G.;Martin, Matthew E.;Vo-Dinh, Tuan
    • ETRI Journal
    • /
    • v.28 no.6
    • /
    • pp.770-776
    • /
    • 2006
  • This paper presents a hyperspectral imaging technique based on laser-induced fluorescence for non-invasive detection of tumorous tissue on mouse skin. Hyperspectral imaging sensors collect image data in a number of narrow, adjacent spectral bands. Such high-resolution measurement of spectral information reveals contiguous emission spectra at each image pixel useful for the characterization of constituent materials. The hyperspectral image data used in this study are fluorescence images of mouse skin consisting of 21 spectral bands in the visible spectrum of the wavelengths ranging from 440 nm to 640 nm. Fluorescence signal is measured with the use of laser excitation at 337 nm. An acousto-optic tunable filter (AOTF) is used to capture images at 10 nm intervals. All spectral band images are spatially registered with the reference band image at 490 nm to obtain exact pixel correspondences by compensating the spatial offsets caused by the refraction differences in AOTF at different wavelengths during the image capture procedure. The unique fluorescence spectral signatures demonstrate a good separation to differentiate malignant tumors from normal tissues for rapid detection of skin cancers without biopsy.

  • PDF