• Title/Summary/Keyword: Narrow backfill

Search Result 14, Processing Time 0.026 seconds

A Study on the Lateral Earthpressure at Behind Structure for Backfill by Sand (구조물 배면에 사질토 되메움시 유발되는 수평토압에 관한연구)

  • Lee, Sang-Duk;Kang, Se-Gu
    • Journal of the Korean Geosynthetics Society
    • /
    • v.10 no.4
    • /
    • pp.11-18
    • /
    • 2011
  • In this study, the reinforcing effect of geogrids in the narrow backfill by sand was experimentally studied. In the model tests, the size of space and the slope of the cut off slope were varied out. The resultant and the distribution of lateral earth pressure were measured. Width of backfill space varied 10 cm, 20 cm, 30 cm at the lower wall level and angle of the cut off slope varied $90^{\circ}$, $75^{\circ}$, $60^{\circ}$. Geogrids were installed in the backfill. Measured results showed that the distribution of the lateral earth pressure due to the narrow backfill developed in a arching shape. And the earth pressure was reduced due to the reinforcement of the backfill by geogrid. geogrid helps reduction of lateral earth pressure.

Evaluation of Construction Applicability for Slurry Backfill Materials of Underground Power Cable (지중송전관로 유동화 뒷채움재의 시공성 평가)

  • Kim, Dae-Hong;Cho, Hwa-Kyung;Oh, Gi-Dae;Lee, Dae-Soo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.1068-1075
    • /
    • 2006
  • Flow-able backfill is known as soil-cement slurry, void fill, and controlled low-strength material (CLSM). The benefits of CLSM include reduced equipment costs, faster construction, re-excavation in the future, and the ability to place material in confined spaces such as narrow parts nearly impossible for compaction or perimeter of underground power cables. A review of some recent full-scale tests carried out by KEPRI on slurry backfill materials for application in underground power cable was presented. Based on this research, applicability was assessed and compare to results of laboratory tests for improved slurry materials with optimal mixture contents.

  • PDF

A Study on Earth Pressure in Unsymmetrical Narrow Backfill Space (비대칭 좁은 공간에서의 되메움 토압에 관한 연구)

  • 문창열
    • Journal of the Korean Geotechnical Society
    • /
    • v.15 no.4
    • /
    • pp.261-277
    • /
    • 1999
  • The horizontal and vertical earth pressures in backfill space which is narrowly excavated like ditch are affected by the share of ditch backfill space and the wall friction between excavated surface and backfill soil. In this paper, for the excavated surface the Handy's equation of a symmetric vertical case and the Kellogg's equation of a symmetric sloped one are modified to show the minor principal stress arch for the unsymmetrical excavated backfill space. Compared with the soil test box result, a similarity in magnitude and distribution of backfill earth pressure shows that the earth pressure has been observed. The backfill earth pressure in unsymmetrically sloped space has been shown twice as much as the one in vertically excavated space and also remarkable decline of arching for the former case. It is verified that the earth pressure equation should account the shape and size of backfill space to calculate the earth pressure for similar structure to the one handled in this study.

  • PDF

The Seismic Behavior of Corrugated Steel Plate Lining in Cut-and-Cover Tunnel (개착식 터널에서 파형강판 라이닝의 동적 거동 특성)

  • Kim Jung-Ho;Kim Nag-Young;Lee Yong-Jun;Lee Seung-Ho;Chung Hyung-Sik
    • 한국터널공학회:학술대회논문집
    • /
    • 2005.04a
    • /
    • pp.233-247
    • /
    • 2005
  • Most tunnel lining material which has been used in the domestic is a concrete. But many problems as the construction period, the cost, and the crack occurrence for the design, construction, and management were happened in the concrete lining. For this reason, many research institutes like the Korea Highway Corporation recognize the necessity of an alternate material development and grow on the interest for that. So in this study, the seismic behaviour characteristics for the application of the Corrugated Steel Plate Lining in cut-and-cover tunnel are evaluated as several conditions for the backfill height, the cutting slope, and the relative density of backfill soil are changed. The compressive stress which is calculated in the Corrugated Steel Plate Lining by the seismic load is decreased as the backfill height increases and the cut slope grows gentle. Also, the moment shows the tendency of decrease according to the increase of the backfill height. But in the case of the relative density of the backfill soil is small, the moment increases according to the increase of the backfill height and affects the dynamic behaviour characteristic. So it is considered that the relative density of the backfill soil is also the important point. As the result in analyzing the seismic response characteristics of the reinforcement spacing of the Corrugated Steel Plate, the variation in the compressive force is hardly happened, but the moment and the shear force increase on the reinforcement spacing being narrow.

  • PDF

Optimal Mixture Contents of Accelerated Flowable Backfill Materials Using Surplus Soil for Underground Power Utilities (굴착잔토를 재활용한 지중전력구조물 급결성 유동화 뒷채움재의 최적배합비)

  • Cheon, Seon-Ho;Jeong, Sang-Seom;Lee, Dae-Soo;Cho, Hwa-Kyung
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.10a
    • /
    • pp.395-404
    • /
    • 2005
  • This study is to evaluate the physical and mechanical characteristics of flowable backfill and search for the optimal mixture contents of it used for constructing underground power utilities. flowable backfill is known as soil-cement slurry, void fill, and controlled low-strength material(CLSM). The benefits of CLSM include reduced equipment costs, faster construction, re-excavation in the future, and the ability to place material in confined spaces such as narrow parts nearly impossible for compaction or perimeter of underground power cables. The flowable slurry mixture made with 9 types of soil and 6 types of accelerated mixtures in the laboratory were evaluated for bleeding, flowability, heat resistance, and unconfined compressive strength to meet the aim values of this study.

  • PDF

Horizontal Earth Pressure of the Backfill in the Narrowly Excavated Ground Considering Various Boundary Conditions (좁게 굴착된 뒤채움 지반의 경계조건에 따른 수평응력 변화에 관한 연구)

  • Kim, Hee Su;Ban, Hoki;Moon, Chang-Yeul
    • Journal of the Korean GEO-environmental Society
    • /
    • v.18 no.11
    • /
    • pp.19-26
    • /
    • 2017
  • When narrowly excavated in the urban area, the wall of backfill space is not only symmetrical but also asymmetrical. In this case, the horizontal stress induced by backfilling depends mostly on the wall asymmetry and the wall friction angle. Therefore, in this study, the model test in the laboratory was conducted to investigate horizontal earth pressure with depth considering various boundary conditions such as base width, wall friction, relative density of backfill, and wall angle. As the wall is smoother and wall angle is lower from the bottom, the results showed higher the horizontal stresses due to the increase of vertical stresses.

Lateral Earth Pressure with The Shape of Narrow Space with Backfill (좁은 공간의 형상에 따른 되메움 토압에 관한 연구)

  • Huh, Kyung-Han
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.1
    • /
    • pp.89-96
    • /
    • 2008
  • The study, with regard to unsymmetrically inclined backfilled wall, was intended to estimate the lateral earth pressure, develop the equation for lateral earth pressure and eventually identify the mutual behavior, based on the modified Kellogg theory, while changing the width between the walls, wall angle, relative density and wall friction angle. To verify the geostatic pressure obtained from the study, the results in the wake of 62 kinds of model tests performed were compared and evaluated with the behaviors based on theoretical equations. As a result, the wall inclination angle was found to be the factors affecting the earth pressure the most, when both walls were inclined unsymmetrically. And the narrower the backfill space and the larger the wall inclination angle to the horizontal level, the greater the effect of the wall friction. The equation considering the wall friction reaction indicated the value, which was closer to the actually-measured earth pressure, and when the width between the warts was narrow, the arching effect appeared to be great, thereby indicating the difference between the measured earth pressure, theoretically calculated earth pressure and the geostatic pressure proved to be insignificant.

An Experimental Study on the Earth Pressure on the Underground Box Structure (지하 박스구조물에 작용하는 토압에 관한 실험적 연구)

  • 김은섭;이상덕
    • Journal of the Korean Geotechnical Society
    • /
    • v.15 no.4
    • /
    • pp.235-246
    • /
    • 1999
  • Some of the underground structures such as subway tunnels are constructed by open cut method, in which the ground is excavated, a structure installed, and after that the excavated space is backfilled. In this case, because of their narrow and constrained boundary conditions, the earth pressure induced by self-weight of the backfilled soil acting on the underground structures is different from that of the classical theory. The vertical and horizontal earth pressures acting on upper slab and side wall of the underground structures constructed by open cut method are affected by the backfill geometry. The laboratory model tests were performed in the conditions of a variety of the shapes of backfill geometry and wall friction. And their results were compared with those from theories. As a result, it was observed that the distribution of the earth pressure acting on the underground structure is affected by the shapes of backfill geometry, the width of backfill, the angle of excavation and the wall friction.

  • PDF

A Study on the Comparison of the Backfill Loads Obtained by the Marston-Spangler에s Theory and by the Finite Element Analysis for the Metal-Polyethylene Composite Pipes (금속-폴리에틸렌 복합관에 대해서 Marston-Spagler이론과 유한요소해석에 의해 구해진 뒤채움하중의 비교에 관한 연구)

  • 정진호
    • Geotechnical Engineering
    • /
    • v.14 no.5
    • /
    • pp.89-110
    • /
    • 1998
  • Variations of backfill load on the metal-polyethylene composite( MPC ) pipes buried in various trenches backfill afterward were investigated in this paper. The backfill loads obtained by the finite element method( FBM ) were compared with those calculated by the well-known MarstonBpangler(M-5) theory. The reliability of the finite element analysis used in this study was examined by an inaitu best for the buried pipe. The backfill lords and deflections on the real-size pipe buried on-site were measured while increasing the backfill height. In addition, further investigations were made for the variations of the backfill loads as a function of several important parameters such as the backfill soil type, bach. height$(\leq4.0m)$, diameter of the pipe$(B.$1.0m)$, and trench width($\leq 3.0 B_c$). It is confirmed that the M-S theory predicts reasonably well the backfill loafs of the MPC of the M-S backfill coils be 0.13 and 0.15 for the SC and SM coils in the D unman soil model, respectively. The load ratio, Wu-s/WwgM for a narrow trench varies negligibly with the back(111 height but fiends to increase for a wide trench. The ratio increases with increasing diameter of the pipe for a narrow trench while decreasing for a wide trench. It is also found that the ratio generally decreases as the degree of compaction increases and BM soil exhibits larger load ratio than that of SC soil.

  • PDF

Mechanical Characteristics of Accelerated Flowable Backfill Materials Using Surplus Soil for Underground Power Utilities (굴착 잔토를 재활용한 지중전력구조물 뒷채움재의 역학적 특성)

  • Cheon, SeonHo;Jeong, Sangseom;Lee, DaeSoo;Kim, DaeHong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.5C
    • /
    • pp.303-312
    • /
    • 2006
  • This study is to evaluate the mechanical characteristics of flowable backfill and offer a guide line of mixture proportion based on soil types for constructing underground power utilities. Flowable backfill is known as soil-cement slurry, void fill, and controlled low-strength material(CLSM). The benefits of CLSM are reduced equipment costs, faster construction, re-excavation in the future, and the ability to place materials in confined spaces, which are narrow parts or perimeters of underground power cables nearly impossible for compaction. The flowable slurry mixed with 17 soils and 6 accelerated mixtures in the laboratory were evaluated for flowability and unconfined compressive strength to meet the target values of this study.