• Title/Summary/Keyword: Naked eye detection

Search Result 56, Processing Time 0.03 seconds

A Naked Eye Detection of Fluoride with Urea Receptors Which have both an Azo Group and a Nitrophenyl Group as a Signaling Group

  • Dang, Nhat Tuan;Park, Jin-Joo;Jang, Soon-Min;Kang, Jong-Min
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.5
    • /
    • pp.1204-1208
    • /
    • 2010
  • Anion recognition via hydrogen-bonding interactions could be monitored with changes in UV-vis absorption spectra and in some cases easily monitored with naked eye. Urea receptors 1 and 2 connected with both an azo group and a nitrophenyl group as a signaling group for color change proved to be an efficient naked eye receptor for the fluoride ion. The anion recognition phenomena of the receptors 1 and 2 via hydrogen-bonding interactions were investigated through UV-vis absorption and $^1H$ NMR spectra.

Edge Detection based on Non Local Means (비지역적 평균 기법을 이용한 경계 검출)

  • Kim, Han-Su;Choi, Myung-Ruyl
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2011.11a
    • /
    • pp.298-301
    • /
    • 2011
  • Edge detection is an base research task in the field of image processing. Edge detection can be regarded as a technique for locating pixels of abrupt gray-level change. So with Gradient method, it can be computed easily. But it can't satisfy human naked eye. so in this paper, new algorithm based on the NLM(Non Local Means) is proposed for good performance for human naked eye.

LCD BLU Defects Detection System with Sidelight (측면조명을 이용한 LCD 백라이트 불량검출 시스템)

  • Moon, Chang-Bae;Bark, Jee-Woong;Lee, Hae-Yeoun;Kim, Byeong-Man;Shin, Yoon-Sik
    • The KIPS Transactions:PartB
    • /
    • v.17B no.6
    • /
    • pp.445-458
    • /
    • 2010
  • A Cold Cathode Fluorescent Lamp(CCFL) is used as a LCD Monitor's backlight widely. The most common way to check CCFL's defects is an examination with the naked eye. This naked eye examination can cause examination inconsistencies and industrial disasters. A shooting environment and detection algorithms are important for finding CCFL defects automatically. This paper presents CCFL defect detection algorithms using images captured under the shooting environment with sidelight which is one of the shooting environment we have suggested. The experimental result shows 4.65% of overdetection and 5.37% of unsuccessful defect detection of CCFL.

Implementation of Automatic Detection System for CCFL's Defects based on Combined Lighting (조합조명 기반 CCFL 불량판별 자동화 시스템 구현)

  • Moon, Chang-Bae;Ahn, Young-Hoon;Lee, Hae-Yeoun;Kim, Byeong-Man;Oh, Duk-Whan
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.15 no.2
    • /
    • pp.69-81
    • /
    • 2010
  • A Cold Cathode Fluorescent Lamp(CCFL) is used as a LCD Monitor's backlight widely. The most common way to check CCFL's defects is an examination with the naked eye. This naked eye examination can cause an examination inconsistency and an industrial disaster. To examine CCFL defects, a shooting equipment and a defect detection algorithm are necessary. This paper shows the shooting environments for checking CCFL and presents some CCFL defect detection algorithms. As a result of experiments, our implementations showed 98.32% of successful defect detection of CCFL.

PDA Sensors for the Detection of Pathogenic Bacteria and Hazardous Substances (병원성미생물 및 유해물질 검출을 위한 PDA 센서)

  • Lim, Min-Cheol;Kim, Young-Rok
    • Journal of Dairy Science and Biotechnology
    • /
    • v.29 no.2
    • /
    • pp.43-49
    • /
    • 2011
  • The increasing number of analytes in concern and the alarming health and environmental consequences have required effective means of monitoring for safety control. Biosensors offer advantages as alternatives to conventional analytical methods because of their inherent specificity, simplicity, and quick response. Colorimetric biosensor, one of biosensor group, is one of the easiest and the most convenient methods because detection can be done using naked eye. Recently, a novel method for rapid detection and read-out of specific immunoassays with naked eye using polydiacetylene (PDA) was developed. Polydiacetylene has recently been in the limelight as a transducing materials because of its special features that allow optical transduction of sensory signals and inherent simplicity and ease of use in supramolecular chemistry. Various forms of PDA are used as a sensor platform for detection of various biological analytes such as viruses, DNA, proteins, bacteria and hazardous molecules.

  • PDF

Highly Sensitive and Naked Eye Dual-readout Method for ʟ-Cysteine Detection Based on the NSET of Fluorophore Functionalized Gold Nanoparticles

  • Fu, Xin;Liu, Yuan;Wu, Zhitao;Zhang, He
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.4
    • /
    • pp.1159-1164
    • /
    • 2014
  • A simple, highly sensitive and selective method based on the rhodamine B-covered gold nanoparticle with dual-readout (colorimetric and fluorometric) detection for $\small{L}$-cysteine is proposed. A mechanism is that citrate-stabilized AuNPs were modified with RB by electrostatic interaction, which enables the nanometal surface energy transfer (NSET) from the RB to the AuNPs, quenching the fluorescence. In the presence of $\small{L}$-cysteine, it was used as a competitor in the NSET by the strongly Au-S bonding to release RB from the Au surface and recover the fluorescence, and the red-to-purple color change quickly, which was monitored simply by the naked eye. Under the optimum conditions, the detection limit is as low as 10 nM. The method possessed the advantages of simplicity, rapidity and sensitivity at the same time. The method was also successfully applied to the determination of $\small{L}$-cysteine in human urine samples, and the results were satisfying.

Crack Detection of Concrete Structures Using Optical Fiber Cables (광섬유 케이블을 이용한 콘크리트 구조물의 균열 탐사)

  • 조남소;김남식
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.896-902
    • /
    • 2000
  • Crack detection technique for concrete structures has been developed in this study,. The technique utilizes OTDR(Optical Time Domain Reflectometer) method that is widely used in the field of optical engineering. At present, some techniques, such as the naked eye inspection, inspection by crack gauge, ultra sonic detection and os on, are used for crack detection. However, these are not economical and are often time-consuming works. This method employs a common optical fiber as a means of crack detection. Th optical fiber is fully attached to concrete surface, and a crack on concrete could be detected to synchronize with the crack on optical fiber. The experimental verification was performed for concrete beams and the intial crack on the beam was detected under cracking force.

  • PDF

Gold Nanoparticle-Based Detection of Hg(II) in an Aqueous Solution: Fluorescence Quenching and Surface-Enhanced Raman Scattering Study

  • Ganbold, Erdene-Ochir;Park, Jin-Ho;Ock, Kwang-Su;Joo, Sang-Woo
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.2
    • /
    • pp.519-523
    • /
    • 2011
  • We studied the detection of the Hg(II) concentration in an aqueous solution using rhodamine dyes on citrate-reduced Au nanoparticles (NPs). The quenching effect from Au NPs was found to decrease as the Hg(II) concentration increased under our experimental conditions. As the fluorescence signals intensified, the surface-enhanced Raman scattering (SERS) intensities reduced on the contrary due to less rhodamine dyes on Au NPs as the Hg(II) concentration increased. The rhodamine 6G (Rh6G) and rhodamine 123 (Rh123) dyes were examined via fluorescence and SERS measurements depending on Hg(II) concentrations. Fast and easy fluorescence detection of an Hg (II) concentration as low as a few ppm could be achieved by naked eye using citrate-reduced Au NPs.

Clinical validation of ImmuneCheck IgE for the rapid detection of serum total IgE (총 IgE의 신속한 정량 측정을 위한 ImmuneCheck IgE의 임상적 유용성)

  • Lee, Shinhaeng;Choi, Jinyoung;Choe, Eunju;Lee, Sang Chul;Park, Kyung Hee;Lee, Jae-Hyun;Park, Jung-Won
    • Allergy, Asthma & Respiratory Disease
    • /
    • v.6 no.6
    • /
    • pp.310-314
    • /
    • 2018
  • Purpose: Conventional serum IgE assay was costly, required the skills of expert, and relied heavily on expensive equipment. Quantitative measurement of total IgE using Point of Care Test (POCT) device can be the solution for these limitations. This study evaluated and validated the reproducibility of ImmuneCheck IgE. Methods: This study included 120 patients of allergic diseases such as allergic rhinitis, asthma, drug allergy, food allergy, atopic dermatitis, or anaphylaxis. The reliability of POCT ImmuneCheck IgE was evaluated by comparing results from the naked eye and from the Q-Reader. Intratest reproducibility and intertest correlation were analyzed using intraclass correlation coefficient (ICC). Results: Of the 120 enrolled patients, 51 were males and 69 were females. The ages ranged from 19 to 84 years, with an average age of 51.5 years. The concentration of serum total IgE measured by Phadia ImmunoCAP IgE ranged from 5.95 to 5,000 IU/mL. ICC for Intratest reproducibility of ImmuneCheck IgE by naked eye and by Q-Reader were 0.991 (P< 0.001) and 0.989 (P< 0.001), respectively. In addition, intertest correlation between ImmuneCheck IgE and Phadia ImmunoCAP IgE results of naked eye and Q-Reader were 0.968 (P< 0.001) and 0.948 (P< 0.001), respectively. Conclusion: The ImmuneCheck IgE was reproducible and highly correlated with conventional Phadia ImmunoCAP IgE assay. This result suggests that ImmuneCheck IgE can be a useful tool for rapid and precise detection of total IgE.

Automatic Safety Inspection Technique for Ammunition Fuzes using Radiographic Images (방사선 영상을 이용한 탄약신관 안전상태 자동인식기술 개발)

  • An, Ji Yeon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.18 no.3
    • /
    • pp.283-292
    • /
    • 2015
  • This paper presents the development of the automatic safety inspection technique for the ammunition fuzes using radiography images. The technique inspects 49-ammunition fuze by detecting the X-ray or neutron radiographic images to check whether the fuze is unintendedly armed or/and some major assembled parts are at right place. To execute the program, we loads the image(s) for under test. After reading images, the program conducts a series of pre-image processing, and then starts inspecting input images by using the detection algorithms which are designed distinctively for each fuze. After completing the detection process, the program displays the final result of the fuze status: "safety or danger." Through this program, we can cut off the fuzes which have any doubt about safety, and can only provide absolutely safe fuzes, compared with the current naked eye inspection method.