• Title/Summary/Keyword: NaI 검출기

Search Result 69, Processing Time 0.024 seconds

A Fast Neutron Time-of-Flight Spectrometer with High Resolution

  • Cho, Mann
    • Nuclear Engineering and Technology
    • /
    • v.4 no.2
    • /
    • pp.116-131
    • /
    • 1972
  • A fast neutron time-of-flight spectrometer has been constructed with suitable choice of target thickness and proton bombarding energy in Li$^{7}$ (p, n) Be$^{7}$ nuclear reaction for a continuous keV spectrum of neutrons at 0 degree in 1-nsec pulse from a Van do Graaff and a time-pick-up fast neutron detector assembled with a 5 mm-thick 92% enriched B$^{10}$ slab and four heavily shielded 4"$\times$3" NaI scintillation detectors. Energy resolution of this spectrometer is better than 0.3% at 50 keV and the signal-to-background ratio is also improved. Total cross section measurements of several separated single isotopes have been carried out with this spectrometer and analyzed by Rmaxtrix multi-level computer code. The spin values and resonance parameters of each individual resonances are given.

  • PDF

Study on Radioactive Material Management Plan and Environmental Analysis of Water (I) Study of Radioactive Substances in Water Management and Analysis to Eat of the US Environmental Protection Agency (Envirionmental Protection Agency) (물 환경의 방사성 물질 관리 방안과 분석법에 관한 연구 (I) 미국환경보호청(Envirionmental Protection Agency)의 먹는 물 방사성물질 관리와 분석법에 관한 고찰)

  • Her, Jae;Kim, Jung-Min;Min, Hye-Lim;Han, Seong-Gyu;Lim, Hyun-Jong;Jo, Han-Byeol;Noh, Young-Hoon;Lee, Ho-Sun;Park, Min-Suk
    • Journal of radiological science and technology
    • /
    • v.38 no.2
    • /
    • pp.163-170
    • /
    • 2015
  • The interest of the people in the radioactive contamination of the water has increased significantly and the study about analysis and management of radioactive materials are being actively conducted. And monitoring spots have been expanded to the range of public water as well as drinking water by publishing the rule of drinking water quality standards and examination in the Environmental Enforcement Ordinance No. 553 of Korea. In this study, US EPA was investigated as the foreign advanced cases and the way that is appropriate for the Korea was sought by analyzing investigate radionuclide, interval and management. As a result, in the selection part of investigate radionuclide, geological survey, status of nuclear power plants and the presence of the use of artificial radionuclides of the Korea should be investigated and additionally after the selection of a few radionuclides, the systems should be extended to cover all possible radionuclides by considering radioactive pollution levels in humans may be exposed due to the annual drinking water. In the part of the investigate interval, the concept(MCL, DL) should be set up for preventing concentration detection of above MCL and it needs to the maintenance and management. For example, when the concentration is more than MCL, it should be investigated on a quarterly and when the concentration is lower than MCL, it should be investigated to each different interval and management. And the US EPA divided the management area and make the roadmap for managing drinking water. The each classified area has been organized to match the state budget and labor force and the individual data have been managed effectively by HPGe, the NaI, TLD and so on.

Measurement of $^{93}Nb(n,n{\alpha})^{89m}Y$, $^{93}Nb(n,{\alpha})^{90m}Y$ and $^{93}Nb(n,2n)^{92m}Nb$ Cross Sections for 14 MeV Neutrons ($^{93}Nb(n,n{\alpha})^{89m}Y$, $^{93}Nb(n,{\alpha})^{90m}Y$$^{93}Nb(n,2n)^{92m}Nb$ 반응의 14 MeV 중성자 반응 단면적 측정)

  • Kim, Y.S.;Kim, N.B.;Chung, K.H.;Bak, H.I.
    • Nuclear Engineering and Technology
    • /
    • v.18 no.2
    • /
    • pp.92-96
    • /
    • 1986
  • The $^{93}Nb(n,n\alpha)^{89m}Y$, $^{93}Nb(n,{\alpha})^{90m}Y$ and $^{93}Nb(n,2n)^{92m}Nb$ cross sections at a neutron energy of 14.6 MeV have been measured relative to the $^{27}Al(n,p)^{27}Mg$ and $^{27}Al(n,{\alpha})^{24}Na$ cross sections. A small accelerator utilizing $T(D,n)^4He$ reaction was used as a neutron source and the neutron energy spread is about 0.4MeV at the sample. All induced activities were measured with a 70cc HPGe detector in the same geometry.

  • PDF

The Flow-rate Measurements in a Multi-phase Flow Pipeline by Using a Clamp-on Sealed Radioisotope Cross Correlation Flowmeter (투과 감마선 계측신호의 Cross correlation 기법 적용에 의한 다중상 유체의 유량측정)

  • Kim, Jin-Seop;Kim, Jong-Bum;Kim, Jae-Ho;Lee, Na-Young;Jung, Sung-Hee
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.1
    • /
    • pp.13-20
    • /
    • 2008
  • The flow rate measurements in a multi-phase flow pipeline were evaluated quantitatively by means of a clamp-on sealed radioisotope based on a cross correlation signal processing technique. The flow rates were calculated by a determination of the transit time between two sealed gamma sources by using a cross correlation function following FFT filtering, then corrected with vapor fraction in the pipeline which was measured by the ${\gamma}$-ray attenuation method. The pipeline model was manufactured by acrylic resin(ID. 8 cm, L=3.5 m, t=10 mm), and the multi-phase flow patterns were realized by an injection of compressed $N_2$ gas. Two sealed gamma sources of $^{137}Cs$ (E=0.662 MeV, ${\Gamma}$ $factor=0.326\;R{\cdot}h^{-1}{\cdot}m^2{\cdot}Ci^{-1}$) of 20 mCi and 17 mCi, and radiation detectors of $2"{\times}2"$ NaI(Tl) scintillation counter (Eberline, SP-3) were used for this study. Under the given conditions(the distance between two sources: 4D(D; inner diameter), N/S ratio: $0.12{\sim}0.15$, sampling time ${\Delta}t$: 4msec), the measured flow rates showed the maximum. relative error of 1.7 % when compared to the real ones through the vapor content corrections($6.1\;%{\sim}9.2\;%$). From a subsequent experiment, it was proven that the closer the distance between the two sealed sources is, the more precise the measured flow rates are. Provided additional studies related to the selection of radioisotopes their activity, and an optimization of the experimental geometry are carried out, it is anticipated that a radioisotope application for flow rate measurements can be used as an important tool for monitoring multi-phase facilities belonging to petrochemical and refinery industries and contributes economically in the light of maintenance and control of them.

Development of New Ocean Radiation Automatic Monitoring System (새로운 해양 방사선 자동 감시 시스템의 개발)

  • Kim, Jae-Heong;Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.23 no.2
    • /
    • pp.743-746
    • /
    • 2019
  • In this paper we proposed a new ocean radiation automatic monitoring system. The proposed system has the following characteristics: First, using NaI + PVT mixed detectors, the response speed is fast and precision analysis is possible. Second, the application of temperature compensation algorithm to scintillator-type sensors does not require additional cooling devices and enables stable operation in the changing ocean environment. Third, since cooling system is not needed, electricity consumption is low, and electricity can be supplied reliably by utilizing solar energy, which can be installed at the observation deck of ocean environment. Fourth, using GPS and wireless communications, accurate location information and real-time data transmission function for measurement areas enables immediate warning response in the event of nuclear accidents such as those involving neighboring countries. The results tested by the authorized testing agency to assess the performance of the proposed system were measured in the range of $5{\mu}Sv/h$ to 15mSv/h, which is the highest level in the world, and the accuracy was determined to be ${\pm}8.1%$, making normal operation below the international standard ${\pm}15%$. The internal environmental grade (waterproof) was achieved, and the rate of variation was measured within 5% at operating temperature of $-20^{\circ}C$ to $50^{\circ}C$ and stability was verified. Since the measured value change rate was measured within 10% after the vibration test, it was confirmed that there will be no change in the measured value due to vibration in the ocean environment caused by waves.

A Study on the Torque Control of Induction Motor using Voltage Source Inverter without speed Sensor (전압형 Inverter에 의한 속도검출기 없는 유도전동기 속도제어)

  • Hwang, L.H.;Kim, J.I.;Jang, B.G.;Lee, S.Y.;Na, S.K.;Kim, J.L.;Lee, C.S.;Cho, M.T.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1130-1132
    • /
    • 2000
  • In this paper, For Control of the speed sensorless induction motor propose the method which is controled the motor by operating two axis current in input current of the inverter. This method determines frequency of inverter in order to stator electromotive force and E/F ratio for the setting magnetic flux, drives for speed control using a voltage power converter of the induction motor by means of voltage fed converter with current control ability.

  • PDF

Determination of Trace Iodide in Sodium Bisulfite Aqueous Solution by Ion Chromatography with UV Detection (이온크로마토그래피를 이용한 Sodium bisulfite 수용액 중의 미량 요오드 정량)

  • Park, Yang-Soon;Kim, Do-Yang;Choi, Kwang-Soon;Park, Soon-Dal;Han, Sun-Ho
    • Analytical Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.304-308
    • /
    • 2000
  • The iodide was recovered from a simulated spent fuel to the sodium bisulfite aqueous solution. It was discussed that the trace iodide (below 1 ppm) was determined without the matrix effect of 0.1 M sodium bisulfite and 1 mM $HNO_3$ in aqueous solution by ion chromatography with UV detection. AS4A-SC (DIONEX) column and UV-absorption spectrophotometer were used. The UV-absorption spectra of sodium bisulfite, nitric acid and iodide were obtained, and then 230 nm was selected as an absorption wavelength for iodide determination. 0.1 M NaCl eluent was optimum condition. In this condition the calibration curve of iodide was obtained on the range of about 0-1,000 ppb. The linear coefficient was 0.99993 and the detection limit was 5 ppb. The relative standard deviation was 1.26%.

  • PDF

Development of a Small Gamma Camera Using NaI(T1)-Position Sensitive Photomultiplier Tube for Breast Imaging (NaI (T1) 섬광결정과 위치민감형 광전자증배관을 이용한 유방암 진단용 소형 감마카메라 개발)

  • Kim, Jong-Ho;Choi, Yong;Kwon, Hong-Seong;Kim, Hee-Joung;Kim, Sang-Eun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Moon-Hae;Joo, Koan-Sik;Kim, Byuug-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.4
    • /
    • pp.365-373
    • /
    • 1998
  • Purpose: The conventional gamma camera is not ideal for scintimammography because of its large detector size (${\sim}500mm$ in width) causing high cost and low image quality. We are developing a small gamma camera dedicated for breast imaging. Materials and Methods: The small gamma camera system consists of a NaI (T1) crystal ($60 mm{\times}60 mm{\times}6 mm$) coupled with a Hamamatsu R3941 Position Sensitive Photomultiplier Tube (PSPMT), a resister chain circuit, preamplifiers, nuclear instrument modules, an analog to digital converter and a personal computer for control and display. The PSPMT was read out using a standard resistive charge division which multiplexes the 34 cross wire anode channels into 4 signals ($X^+,\;X^-,\;Y^+,\;Y^-$). Those signals were individually amplified by four preamplifiers and then, shaped and amplified by amplifiers. The signals were discriminated ana digitized via triggering signal and used to localize the position of an event by applying the Anger logic. Results: The intrinsic sensitivity of the system was approximately 8,000 counts/sec/${\mu}Ci$. High quality flood and hole mask images were obtained. Breast phantom containing $2{\sim}7 mm$ diameter spheres was successfully imaged with a parallel hole collimator The image displayed accurate size and activity distribution over the imaging field of view Conclusion: We have succesfully developed a small gamma camera using NaI(T1)-PSPMT and nuclear Instrument modules. The small gamma camera developed in this study might improve the diagnostic accuracy of scintimammography by optimally imaging the breast.

  • PDF

Traffic Sign Recognition using SVM and Decision Tree for Poor Driving Environment (SVM과 의사결정트리를 이용한 열악한 환경에서의 교통표지판 인식 알고리즘)

  • Jo, Young-Bae;Na, Won-Seob;Eom, Sung-Je;Jeong, Yong-Jin
    • Journal of IKEEE
    • /
    • v.18 no.4
    • /
    • pp.485-494
    • /
    • 2014
  • Traffic Sign Recognition(TSR) is an important element in an Advanced Driver Assistance System(ADAS). However, many studies related to TSR approaches only in normal daytime environment because a sign's unique color doesn't appear in poor environment such as night time, snow, rain or fog. In this paper, we propose a new TSR algorithm based on machine learning for daytime as well as poor environment. In poor environment, traditional methods which use RGB color region doesn't show good performance. So we extracted sign characteristics using HoG extraction, and detected signs using a Support Vector Machine(SVM). The detected sign is recognized by a decision tree based on 25 reference points in a Normalized RGB system. The detection rate of the proposed system is 96.4% and the recognition rate is 94% when applied in poor environment. The testing was performed on an Intel i5 processor at 3.4 GHz using Full HD resolution images. As a result, the proposed algorithm shows that machine learning based detection and recognition methods can efficiently be used for TSR algorithm even in poor driving environment.

Analysis of Gamma-ray Spectrum and Assessment of Corresponding Exposure Rate by Means of Response Matrix Method (Response Matrix에 의한 감마선(線) Spectrum 및 그 조사선량(照射線量) 해석(解析))

  • Kim, Seong-Kwan;Jun, Jae-Shik
    • Journal of Radiation Protection and Research
    • /
    • v.11 no.1
    • /
    • pp.3-14
    • /
    • 1986
  • A stud has been carried out for figuring out real photon spectrum from an observed gamma-ray spectrum by means of response matrix method, which is known one of the relatively convenient method for the estimation of exposure rate of a complex gamma ray field in comparison with graphical analysis and least square fitting of the measured spectrum. A 3'${\times}$3' cylindrical Nal(T1) scintillation detector in association with multichannel pulse height analyzer and six reference gamma ray sources covering the photon energy range of 0.05 to 2.0 MeV were used. In dividing the energy region for the construction of response matrix, two different approaches were attempted. One is dividing the entire energy region of interest into 20 bins, one of which corresponds to a width of 0.1 MeV to form $20{\times}20$ matrix, and another is dividing the 2 MeV region into 14 bins to form $14{\times}14$ matrix consists of $0.1(MeV)^{1/2}$ intervals assuming the resolution of the detector is dependent on square root of the incident photon energy. Inversion of thus constructed matrices was performed by a computor(P-E8/32) using the program attached to the end of this paper. The resultant exposure rates obtained by this method were in good agreement, within 10% with those calculated by ordinary formula widely used for a gamma-ray field of known energy and flux. It is concluded that the photen flux obtained by the response matrix constructed under the assumption of $E^{1/2}$ dependence is more realistic than that obtained by the matrix consist of identical energy bins in dosimetrical point of view.

  • PDF