• Title/Summary/Keyword: NS7

Search Result 498, Processing Time 0.031 seconds

Feline adipose tissue-derived mesenchymal stem cells pretreated with IFN-γ enhance immunomodulatory effects through the PGE2 pathway

  • Park, Seol-Gi;An, Ju-Hyun;Li, Qiang;Chae, Hyung-Kyu;Park, Su-Min;Lee, Jeong-Hwa;Ahn, Jin-Ok;Song, Woo-Jin;Youn, Hwa-Young
    • Journal of Veterinary Science
    • /
    • v.22 no.2
    • /
    • pp.16.1-16.13
    • /
    • 2021
  • Background: Preconditioning with inflammatory stimuli is used to improve the secretion of anti-inflammatory agents in stem cells from variant species such as mouse, human, and dog. However, there are only few studies on feline stem cells. Objectives: This study aimed to evaluate the immune regulatory capacity of feline adipose tissue-derived (fAT) mesenchymal stem cells (MSCs) pretreated with interferon-gamma (IFN-γ). Methods: To assess the interaction of lymphocytes and macrophages with IFN-γ-pretreated fAT-MSCs, mouse splenocytes and RAW 264.7 cells were cultured with the conditioned media from IFN-γ-pretreated MSCs. Results: Pretreatment with IFN-γ increased the gene expression levels of cyclooxygenase-2, indoleamine 2,3-dioxygenase, hepatocyte growth factor, and transforming growth factor-beta 1 in the MSCs. The conditioned media from IFN-γ-pretreated MSCs increased the expression levels of M2 macrophage markers and regulatory T-cell markers compared to those in the conditioned media from naive MSCs. Further, prostaglandin E2 (PGE2) inhibitor NS-398 attenuated the immunoregulatory potential of MSCs, suggesting that the increased PGE2 levels induced by IFN-γ stimulation is a crucial factor in the immune regulatory capacity of MSCs pretreated with IFN-γ. Conclusions: IFN-γ pretreatment improves the immune regulatory profile of fAT-MSCs mainly via the secretion of PGE2, which induces macrophage polarization and increases regulatory T-cell numbers.

Artificial Neural Network with Firefly Algorithm-Based Collaborative Spectrum Sensing in Cognitive Radio Networks

  • Velmurugan., S;P. Ezhumalai;E.A. Mary Anita
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.17 no.7
    • /
    • pp.1951-1975
    • /
    • 2023
  • Recent advances in Cognitive Radio Networks (CRN) have elevated them to the status of a critical instrument for overcoming spectrum limits and achieving severe future wireless communication requirements. Collaborative spectrum sensing is presented for efficient channel selection because spectrum sensing is an essential part of CRNs. This study presents an innovative cooperative spectrum sensing (CSS) model that is built on the Firefly Algorithm (FA), as well as machine learning artificial neural networks (ANN). This system makes use of user grouping strategies to improve detection performance dramatically while lowering collaboration costs. Cooperative sensing wasn't used until after cognitive radio users had been correctly identified using energy data samples and an ANN model. Cooperative sensing strategies produce a user base that is either secure, requires less effort, or is faultless. The suggested method's purpose is to choose the best transmission channel. Clustering is utilized by the suggested ANN-FA model to reduce spectrum sensing inaccuracy. The transmission channel that has the highest weight is chosen by employing the method that has been provided for computing channel weight. The proposed ANN-FA model computes channel weight based on three sets of input parameters: PU utilization, CR count, and channel capacity. Using an improved evolutionary algorithm, the key principles of the ANN-FA scheme are optimized to boost the overall efficiency of the CRN channel selection technique. This study proposes the Artificial Neural Network with Firefly Algorithm (ANN-FA) for cognitive radio networks to overcome the obstacles. This proposed work focuses primarily on sensing the optimal secondary user channel and reducing the spectrum handoff delay in wireless networks. Several benchmark functions are utilized We analyze the efficacy of this innovative strategy by evaluating its performance. The performance of ANN-FA is 22.72 percent more robust and effective than that of the other metaheuristic algorithm, according to experimental findings. The proposed ANN-FA model is simulated using the NS2 simulator, The results are evaluated in terms of average interference ratio, spectrum opportunity utilization, three metrics are measured: packet delivery ratio (PDR), end-to-end delay, and end-to-average throughput for a variety of different CRs found in the network.

Endoscopic Radial Artery Harvest: Techniques & Results (내시경을 이용한 요골동맥 수확법의 수술 방법과 결과)

  • Jeong, Young-Kyun;Lee, Jong-Tae;Cho, Jun-Yong;Kim, Kyu-Tae;Chang, Bong-Hyun
    • Journal of Chest Surgery
    • /
    • v.39 no.1 s.258
    • /
    • pp.35-41
    • /
    • 2006
  • Background: The radial arteries are being used more often for coronary artery bypass grafting, We tried to the endoscopic radial artery harvest to reduce the cosmetic problems and neurologic complications of the conventional open harvesting and report the techniques and early results. Material and Method: The 86 patients underwent coronary artery bypass grafting between May 2003 and April 2005 had their nondominant radial artery endoscopically removed through a 2 cm incision at the wrist. The radial pedicle was dissected and was divided at antecubial area through a 5 mm counterincision. Result: The 23 patients complained of neuralgias on territory of superficial raidal none but no one complained of neuralgias on territory of lateral antebrachial cutaneous none. There was no functional impairment of the hand. There was no wound complication except a localized hematoma. All patients were contacted by telephone after postoperative 7.9$\pm$3.6 months. The 4 patients still complained of neuralgia. All the patients were satisfied with the aesthetics of the wounds. The multidetectional tomography was done on the 66 patients for the estimation of early patency of radial artery. There were 2 cases of stenosis and a case of occlusion. Conclusion: Endoscopic radial artery harvest had no functional impairment of the hand, lesser rate of neurologic complications and outstanding aesthetics. The results of early patency of the radial artery was similar to conventional methods. Therefore, we think that endoscopic radial artery harvest is the optimal procedure.

Chimooite, a New Mineral from Dongnam Mine, Korea (동남광산에서 발견된 신종광물 Zn­란시아이트(치무석))

  • 최헌수;김수진
    • Journal of the Mineralogical Society of Korea
    • /
    • v.16 no.4
    • /
    • pp.333-339
    • /
    • 2003
  • A new mineral, Zn analogue of rancieite (Chimooite), has been discovered at the Dongnam mine, Korea. It occurs as compact subparallel fine­grained flaky or acicular aggregates in the massive manganese oxide ores which were formed by supergene oxidation of rhodochrosite­sulfide ores in the hydrothermal veins trending NS­N25E and cutting the Pungchon limestone of the Cambrian age. The flakes of chimooite are 0.2 mm for the largest one, but usually less than 0.05 mm. The acicular crystals are elongated parallel to and flattened on (001). This mineral shows gradation to rancieite constituting its marginal part, thus both minerals are found in one and the same flake. Color is bluish black, with dull luster and brown streak in globular or massive aggregates. Cleavage is perfect in one direction. The hardness ranges from 2.5 to 4. Under reflected light it is anisotropic and bireflectant. It shows reddish brown internal reflection. Chemical analyses of different parts of both minerals suggest that rancieite and chimooite constitute a continuous solid solution series by cationic substitution. The empirical chemical formula for chimooite has been calculated following the general formula, $R_2_{x}$ M $n^{4+}$$_{9­x}$ $O_{18}$ $.$n$H_2O$ for the 7 $\AA$ phyllomanganate minerals, where x varies from 0.81 to 1.28 in so far studied samples, thus averaging to 1.0. Therefore, the formula of Zn­rancieite is close to the well­known strochiometric formula $_Mn_4^{4+}$ $O_{9}$ $.$4$H_2O$. The mineral has the formula (Z $n_{0.78}$N $a_{0.15}$C $a_{0.08}$M $g_{0.01}$ $K_{0.01}$)(M $n^{4+}$$_{3.98}$F $e^{3+}$$_{0.02}$)$_{4.00}$ $O_{9}$ $.$3.85$H_2O$, thus the ideal formula is (Zn,Ca)M $n^{4+}$$_4$ $O_{9}$ $.$3.85$H_2O$. The mineral has a hexagonal unit ceil with a=2.840 $\AA$ c=7.486 $\AA$ and a : c = 1 : 2.636. The DTA curve shows endothermic peaks at 65, 180, 690 and 102$0^{\circ}C$. The IR absorption spectrum shows absorption bands at 445, 500, 1630 and 3400 c $m^{1}$. The mineral name Chimooite has been named in honour of late Prof, Chi Moo Son of Seoul National University.ity.versity.ity.y.

The Results of Drilling in Weondong Mine Area, the Taebaegsan Mineralized District, Republic of Korea (강원도 태백산지역 원동광산 시추탐사연구)

  • Lee, Jae-Ho
    • Economic and Environmental Geology
    • /
    • v.44 no.4
    • /
    • pp.313-320
    • /
    • 2011
  • The Taebaegsan Mineralized District is the most prospective region for the useful mineral commodities such as a coal, non-metallic, metallic mineral in South Korea. From a general point of view, Cambro- Ordovician limestone formations, Myobong slate and Pungchon (Daegi) limestone, are the most fertilizable formations in the Taebaegsan Mineralized District. The geology around Weondong mine area consists mainly of Carboniferous-Triassic formations and Cambro-Ordovician formations intruded by rhyolite/quartz porphyry. The great overthrusted fault of N40~$50^{\circ}E$ direction, so called Weondong overthrust fault, is observed in the central part of the mine area and the NS fault system cuts the overthrusted fault. By postulating from the favorable geological and structural condition around Weondong area, the possibility of deep seated hidden ore bodies is expected. In 2010, on the basis of the results of LOTEM and CSAMT survey, the cross-hole survey was performed for the investigation of the hidden polymetallic ore body in the deep parts of the Weondong mine area and the grade of the newly-discovered orebody is as follows; (1) The cut-off grade for lead-zinc 3%; an weighted average grade 5.50% (2.7 m), (2) The cutoff grade for copper 0.1%; an weighted average grade 0.91% (14.65 m), (3) The cut-off grade for iron 30%; an weighted average grade 38.18% (3.3 m), (4) $WO_3$ for each cut-off grade(0.01%, 0.05%, 0.1%); an weighted average grade 0.29 wt. % (8.8 m), 1.15 wt. % (2.1 m), 1.97 wt. % (1.2 m), (5) $MoS_2$ for each cut-off grade(0.01%, 0.1%); an weighted average grade 0.15 wt. % (6.3S m), 0.28 wt. % (3.15 m), (6) $Ta_2O_5$ for each cut-off grade (0.01%, 0.1%); an weighted average grade 0.13% (19.S m), 1.11% (1.8 m), (7) $Nb_2O_5$ for each cut-offgrade (0.01%, 0.1%); an weighted average grade 0.06% 11.5 m), 0.15% (3.0 m).

A Family Screening of Patients with Vesicoureteral Reflux (방광 요관 역류 환아의 가족 선별 검사에 관한 연구)

  • Kang Hee;Kim Hyung Jin;Yoo Kee Hwan;Hong Young Sook;Lee Joo Won;Kim Soon Kyum
    • Childhood Kidney Diseases
    • /
    • v.5 no.1
    • /
    • pp.36-42
    • /
    • 2001
  • Purpose : Vesicoureteral reflux is the most commonly inherited disease detected in children with urinary tract infection. The incidence of vesicoureteral reflux among siblings of children with known vesicoureteral reflux is 8$\%$ to 45$\%$ according to different authors. Family screening of a patient with vesicoureteral reflux is important in order to prevent reflux nephropathy. The purpose of this study is to determine the incidence of vesicoureteral reflux in asymptomatic family of children with vesicoureteral reflux and the factors which influence the family history. Methods : The study group consisted of 27 families of patients with vesicoureteral reflux. The total number in the group were 79 persons. BUN, Cr, urineanalysis, voidingcystourethrography(VCUG) and 99mTc -dimercaptosuccinic acid(DMSA) renal scan were performed oil tile siblings. As for tile parents the same tests were performed except the VCUG. Results : The abnormality was detected in 7 of 27 families(25.9$\%$). Vesicoureteral reflux was detected in 5 of 20 siblings and renal scar ns detected in 3 of 32 parents. In children with vesicoureteral reflux, renal scar was detected in 24 of 32 children. Between the group with the abnormality in its family(Group A) and the group without the abnormality in its family(Group B), There was no difference of creatinine clearance between two groups. More renal scars were detected in group A according to the DMSA(A:100$\%$, B:75$\%$. t-test P<0.05). There was no difference of grade of VCUG between two groups. There was no difference between one site and both sites in two groups. In tile case of tile siblings with vesicoureteral reflux, there was high incidence of renal scar in a patient with vesicoureteral reflux according to the DMSA. Conclusion : It is important to screen vesicoureteral reflux and renal scar in case of urinary tract infection to prevent reflux nephropathy. This study implies that it is necessary to screen the family of a patient with vesicoureteral reflux especially with renal scar. (J, Korean Soc Pediatr Nephrol 5 : 36- 42, 2001)

  • PDF

Risk Factors for the First-Year Relapse in Children with Nephrotic Syndrome (신증후군 환아에서 1년내 재발과 관련된 위험 요인)

  • Shin, Hye Kyoung;Kim, Ji Hee;Yoo, Kee Hwan;Hong, Young Sook;Lee, Joo Won;Kim, Soon Kyum
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.9
    • /
    • pp.889-892
    • /
    • 2003
  • Purpose : This study aimed to evaluate risk factors of the first year relapse in children with nephrotic syndrome(NS) without the need for biopsy. Methods : We reviewed, retrospectively, 78 children diagnosed with steroid responsive nephrotic syndrome between July 1997 and June 2002. Median years to follow up were 4.4 years(range : 1-5 years). We divided the patients into two groups(group I : primary responders with no relapse or with only two relapses in the first year after initial response; group II : initial steroid responders with three or more relapses within the first year). We retrospectively reviewed and compared variables - sex, onset age, serum albumin, serum cholesterol, 24 hours urinary protein, creatinine clearance(Ccr), presence of hematuria and hypertension(HTN), and days from initial attack to remission. Results : Of 78 patients(male : 61(78.2%), female : 17(21.8%), age range 1.1 years to 14 years, median $5.1{\pm}3.0years$), 47(60.3%) were in group I and 31(39.7%) were in group II. There were no statistically significant differences in sex, serum albumin, serum cholesterol, 24 hours urinary protein, Ccr, presence of hematuria or HTN. The median age of onset showed no statistical difference between the two groups. However, if the patients are dividing into two groups according to the age of onset of three-years, patients theree yrs old or less fit into group II, as opposed to patients older than three yrs in age(63.2% vs. 32.2%, P<0.05). The days from initial attack to remission was longer in group II($12.9{\pm}0.5$ vs. $16.2{\pm}1.1$, P<0.05). Conclusion : We may conclude that the age of onset of three yrs old or less, and the longer time remission to initial steroid therapy, are risk factors of the first year relapse.

Role of Intra-aortic Balloon Pump in High Risk Patients undergoing Off-Pump Coronary artery bypass graft (심폐바이패스 없이 시행하는 관상동맥 우회술시 고위험군 환자에서 대동맥내 풍선 펌프의 유용성)

  • Cho, Suk-Ki;Jang, Woo-Ik;Lim, Cheong;Lee, Cheul;Lee, Jae-Ik;Kim, Yong-Lak;Ham, Byung-Moon;Kim, Ki-Bong
    • Journal of Chest Surgery
    • /
    • v.34 no.12
    • /
    • pp.895-900
    • /
    • 2001
  • Background : This study aimed to evaluate the usefulness of preoperative placement of intraaortic balloon pump(IABP) in reducing operative risk and facilitating posterior vessel OPCAB in high risk patients with left main disease( 75% stenosis), intractable resting angina, postinfarction angina, or left ventricular dysfunction(ejection fraction 35%). Material and Method : One hundred eighty- nine consecutive patients who underwent multi-vessel OPCAB including posterior vessel revascularization were studied. The patients were divided into group I(n=74) that received preoperative or intraoperative IABP and group II(n=115) that did not receive IABP. In group I, there were 39 patients with left main disease, 40 patients with intractable resting angina, 14 patients with left ventricular dysfunction and 7 patients with postinfarction angina. Ten patients received intraoperative IABP support due to hemodynamic instability during OPCAB. Result : There was one operative mortality in group I and two mortalities in group II. The average number of distal anastomoses was not different between group I and group II(3.5$\pm$0.9 vs 3.4$\pm$0.9, p=ns). There were no significant differences in the number of posterior vessel anastomosis per patient between the two groups. There were no differences in ventilator support time, length of hospital stay, and morbidity between the two groups. There was one case of IABP-related complication in group I. Conclusion : IABP facilitates posterior vessel OPCAB in high risk patients, with comparable surgical results to low risk patients

  • PDF

Establishment of the Room Acoustic Criteria for the Korean Traditional Music Halls Using Subjective Listening Tests (청감실험에 의한 국악당의 음향설계조건 설정)

  • Haan, Chan-Hoon;Shin, Jic-Su
    • The Journal of the Acoustical Society of Korea
    • /
    • v.26 no.7
    • /
    • pp.343-352
    • /
    • 2007
  • The present study aims to investigate the design standard for acoustic criteria of Korean traditional music which could be used for the design of Korean traditional music halls. In order to do this, subjective listening tests were undertaken to musicians using auralized sounds which were convolved with the impulse response of traditional instruments recorded in an anechoic chamber. 94 pairs of sound were made which have different value of acoustic parameters including RT, BR, Brilliance, G, C80, ITDG, IACC. A paired comparison method(PCM) was used to analyze the results from the subjective listening tests. The results show that the preference of acoustic criteria for the Korean traditional music is far different from those of western music. As a result, specific range of acoustic criteria were suggested for the appropriate acoustic conditions of Korean traditional music. Also, a guideline of the acoustic design of halls for performing the Korean traditional music was suggested which could be used as a basic reference in the future works.

Performance Evaluation of Siemens CTI ECAT EXACT 47 Scanner Using NEMA NU2-2001 (NEMA NU2-2001을 이용한 Siemens CTI ECAT EXACT 47 스캐너의 표준 성능 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.259-267
    • /
    • 2004
  • Purpose: NEMA NU2-2001 was proposed as a new standard for performance evaluation of whole body PET scanners. in this study, system performance of Siemens CTI ECAT EXACT 47 PET scanner including spatial resolution, sensitivity, scatter fraction, and count rate performance in 2D and 3D mode was evaluated using this new standard method. Methods: ECAT EXACT 47 is a BGO crystal based PET scanner and covers an axial field of view (FOV) of 16.2 cm. Retractable septa allow 2D and 3D data acquisition. All the PET data were acquired according to the NEMA NU2-2001 protocols (coincidence window: 12 ns, energy window: $250{\sim}650$ keV). For the spatial resolution measurement, F-18 point source was placed at the center of the axial FOV((a) x=0, and y=1, (b)x=0, and y=10, (c)x=70, and y=0cm) and a position one fourth of the axial FOV from the center ((a) x=0, and y=1, (b)x=0, and y=10, (c)x=10, and y=0cm). In this case, x and y are transaxial horizontal and vertical, and z is the scanner's axial direction. Images were reconstructed using FBP with ramp filter without any post processing. To measure the system sensitivity, NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves were scanned at the center of transaxial FOV and 10 cm offset from the center. Attenuation free values of sensitivity wire estimated by extrapolating data to the zero wall thickness. NEMA scatter phantom with length of 70 cm was filled with F-18 or C-11solution (2D: 2,900 MBq, 3D: 407 MBq), and coincidence count rates wire measured for 7 half-lives to obtain noise equivalent count rate (MECR) and scatter fraction. We confirmed that dead time loss of the last flame were below 1%. Scatter fraction was estimated by averaging the true to background (staffer+random) ratios of last 3 frames in which the fractions of random rate art negligibly small. Results: Axial and transverse resolutions at 1cm offset from the center were 0.62 and 0.66 cm (FBP in 2D and 3D), and 0.67 and 0.69 cm (FBP in 2D and 3D). Axial, transverse radial, and transverse tangential resolutions at 10cm offset from the center were 0.72 and 0.68 cm (FBP in 2D and 3D), 0.63 and 0.66 cm (FBP in 2D and 3D), and 0.72 and 0.66 cm (FBP in 2D and 3D). Sensitivity values were 708.6 (2D), 2931.3 (3D) counts/sec/MBq at the center and 728.7 (2D, 3398.2 (3D) counts/sec/MBq at 10 cm offset from the center. Scatter fractions were 0.19 (2D) and 0.49 (3D). Peak true count rate and NECR were 64.0 kcps at 40.1 kBq/mL and 49.6 kcps at 40.1 kBq/mL in 2D and 53.7 kcps at 4.76 kBq/mL and 26.4 kcps at 4.47 kBq/mL in 3D. Conclusion: Information about the performance of CTI ECAT EXACT 47 PET scanner reported in this study will be useful for the quantitative analysis of data and determination of optimal image acquisition protocols using this widely used scanner for clinical and research purposes.