• 제목/요약/키워드: NOTCH4

Search Result 450, Processing Time 0.034 seconds

A Study on the Corrosion Fatigue Characteristics of Ion-nitrided SCM4 Steel in Rotationg Bending (이온질화처리한 SCM4 강의 회전굽힘 부식피로 특성에 관한 연구)

  • Lee, Du-Yong;Woo, Chang-Gi
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.6 no.1
    • /
    • pp.75-84
    • /
    • 1989
  • This paper deals with the effect of $N_2$ and $H_2$gas mixture ratio and ion-nitriding time in the corrosion fatigue fracture behavior of ion-nitrided SCM4 steel with notch subject to rotary bending stress. The specimens were treated rapid water cooling after ion-nitriding at $500^{\circ}C$ Torr for 1 hour and 3 hours in gas mixtures of 80% $N_2$and 50% $N_2$. The fatigue limit and the fracture strength of corrosion fatigue depended on $N_2$gas quantity and ion-nitriding time. The ion-nitrided specimens showed about 88 .approx. 158% increase in the fracture strength of corrosion fatigue in $10^6$ cycles than non-nitrided specimens. The corrosion failure is due to corrosion pitting of the surface, and the propargation of cracks started at the surface into the core.

  • PDF

R-Curve Behavior of Silicon Nitride at Elevated Temperatures

  • Sakaguchi, Shuji
    • The Korean Journal of Ceramics
    • /
    • v.4 no.4
    • /
    • pp.331-335
    • /
    • 1998
  • R-curve, of three kinds of silicon nitride-based ceramics were measured, using single edge notched beam (SENB) method at room and at elevated temperatures, up to $1200^{\circ}C$. Stable fraacture was seen on ceramic materials with SENB specimens if the machined notch is deep enough, even though the crack resistance did not increase with crack length. Hot pressed silicon nitride did not show the rising R-curve behavior at room temperature, but it showed some rising at $1000^{\circ}C$ and above. Si3N4 reinforced with SiC whiskers showed no rising behavior at room and elevated temperatures, as it has smaller grain size, compare to the monolithic specimen. Gas pressure sintered silicon nitride had very large and elongated grains, and it showed rising R-curve even at room temperature. However, it showed some creep behavior at $1200^{\circ}C$ and the calculated R-curve on this condition did not show a good result. We cannot apply this technique on this condition for obtaining the R-curve.

  • PDF

Evaluation of the Effect of High Temperature on the Interface Characteristics between Solid Oxide Fuel Cell and Ag Paste (고온열처리가 고체산화물연료전지의 전극과 Ag 페이스트의 계면에 미치는 특성 평가)

  • Jeon, Sang Koo;Nahm, Seung Hoon;Kwon, Oh Heon
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.1
    • /
    • pp.21-27
    • /
    • 2015
  • In this study, interfacial characteristics between SOFC and Ag paste as current collector was estimated in the high temperature environment. The Ag paste was used to connect the unit cell of SOFC strongly with interconnector and provide the electrical conductivity between them. To confirm electrical conductivity, Ag paste was treated in the furnace at $800^{\circ}C$ for 48 hours. The sheet resistance of Ag paste was measured to compare the resistance values before and after the heat treatment. Also, the four-point bending test was performed to measure the interfacial adhesion. The unit cell of SOFC and $SiO_2$ wafer were diced and then attached by Ag paste. The $SiO_2$ wafer had the center notch to initiate a crack from the tip of the notch. The modified stereomicroscope combined with the CCD camera and system for measuring the length was used to observe the fracture behavior. To compare the characteristics before heat treatment and after heat treatment, the specimen was exposed in the furnace at $800^{\circ}C$ for 48 hours and then the interfacial adhesion was evaluated. Finally, the interfacial adhesion energy quantitatively increases $1.78{\pm}0.07J/m^2$ to $4.9{\pm}0.87J/m^2$ between the cathode and Ag paste and also increase $2.9{\pm}0.47J/m^2$ to $5.12{\pm}1.01J/m^2$ between the anode and Ag paste through the high temperature. Therefore, it is expected that Ag paste as current collector was appropriate for improving the structural stability in the stacked SOFC system if the electrical conductivity was more increased.

The Effects of Dura mater on Healing of Furcation III Defects in Dogs (Dura meter가 성겹 3급 분지부 병소에 미치는 영향)

  • Choi, Sung-Ho;Kim, Joon-Il;Moon, Ik-Sang;Cho, Kyoo-Sung;Chai, Jung-Kyu;Kim, Chong-Kwan
    • Journal of Periodontal and Implant Science
    • /
    • v.26 no.3
    • /
    • pp.591-604
    • /
    • 1996
  • The present study evaluates the effects of dura mater barrier membranes In class III furcation defects on the regeneration of periodontal tissues in dogs. Experimental class III furcation defects were created surgically by removing alveolar bone horizontally down to 4mm from CEJ in mandibular premolars of adult dogs. Dura mater barrier membranes were applied bucco-lingually in the test group, and flap surgery only with no membranes in the control group. The healing was evaluated clinically and histologically after 8weeks. Clinically, the test group showed slight exposures of the membranes, while the control group showed no furcation exposure, The test specimens showed new bone formation coronal to the notch, while the control specimens had new bone formation up to the level of the notch. New cementum was observed in both groups. The test specimens showed functional arrangements of connective tissue fibers between new bone and new cenentum, while irregular arrangements were observed in the controls. No root resorption or ankylosis were observed in either groups,These results suggest that dura mater resorbable barrier membranes on class III furcation defects may be effective in regeneration of alveolar bone and peridontal ligament.

  • PDF

Crack Initiation Life Analysis in Notched Pipe Under Cyclic Bending Loads (굽힘피로 하중을 받는 배관의 피로균열 발생수명 예측)

  • Gwak, Sang-Rok;Lee, Jun-Seong;Kim, Yeong-Jin;Park, Yun-Won
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.10
    • /
    • pp.1528-1534
    • /
    • 2001
  • In order to improve Leak-Be(ore-Break methodology, more precisely the crack growth evaluation, a round robin analysis was proposed by the CEA Saclay. The aim of this analysis was to evaluate the crack initiation life, penetration life and shape of through wall crack under cyclic bending loads. The proposed round robin analysis is composed of three main topic; fatigue crack initiation, crack propagation and crack penetration. This paper deals with the first topic, crack initiation in a notched pipe under four point bending. Both elastic-plastic finite element analysis and Neuber's rule were used to estimate the crack initiation life and the finite element models were verified by mesh-refinement, stress distribution and global deflection. In elastic-plastic finite element analysis, crack initiation life was determined by strain amplitude at the notch tip and strain-life curve of the material. In the analytical method, Neuber's rule with the consideration of load history and mean stress effect, was used for the life estimation. The effect of notch tip radius, strain range, cyclic hardening rule were examined in this study. When these results were compared with the experimental ones, the global deformation was a good agreement but the crack initiation cycle was higher than the experimental result.

Effect of Gastric Filling on the Images of Hepatic Scintigraphy (위의 충만유무에 의한 간신티그램영상의 변화)

  • Lee, J.S.;Choi, M.S.;Sung, C.M.;Lee, J.Y.;Lee, K.H.;Sohn, I.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.23 no.2
    • /
    • pp.189-193
    • /
    • 1989
  • To observe the effect of gastric filling on the images of hepatic scintigraphy, we performed hepatic scintigraphy using $^{99m}Tc-tin$ colloid in twenty patients both in the fasting state and after meal, and made the visual comparison of both images. We found that gastric filling could cause some of the following changes in individual patients. 1) In the anterior view, the distance between the liver and the spleen increased and the interlobar notch of the inferior hepatic border was obliterated. The spleen was displaced downwards, its radioactivity in the upper medial part was reduced, and its upper pole was laterally displaced. 2) In the posterior view, the left lobe of the liver was separated from the spleen and the distance between the liver and the spleen increased. 3) In the right lateral view, the notch separating the right and the left lobes of the liver was well demarcated. 4) In the left lateral view, the spleen was separated from the liver and the distance between the liver and the spleen increased. The shape of the spleen was also changed. In case of the follow-up study, above changes should make one consider the possibility of the effect of gastric filling.

  • PDF

A Study on Hot Straining Embrittlement of Coarse Grained HAZ in Steel Weldments (강 용접열영향부 조립역의 열변형취화에 관한 연구)

  • 정세희;김태영;임재규
    • Journal of Welding and Joining
    • /
    • v.3 no.1
    • /
    • pp.22-31
    • /
    • 1985
  • Hot straining embrittlement is one of the most important factors which cause the brittle fracture initiation even in the service temperature in the case of mild steel and high tensile steel. Therefore it is necessary to analyze thoroughly the hot straining embrittlement occurred in weld HAZ of the structural steels. The behaviors of plastic deformation and fracture toughness at the notch tip of the hot strained weld HAZ in structural steels (SB 41 KS, SA 588-Grade A ASTM) have been studied by the recrystallization technique and crack opening displacement (COD) test method. The obtained results are summarized as follows; 1. The plastic zone is formed at the notch tip of weld HAZ owing to nomotonic and cyclic hot stran, and the maximum plastic strain increases with the accumulated hot straining amounts. 2. The distribution of the effective strain at the plastic deformed zone in HAZ can be determined as follows; (.epsilon. over bar $_{p}$ )$_{\chi}$=.epsilon. over bar $_{cr}$ ( $R_{/chi}$/.chi.)$^{m}$ where, .epsilon. over bar $_{cr}$ : (SB 41; .epsilon. over bar $_{cr}$ = 0.2, SA 588; .epsilon. over bar $_{cr}$ = 0.1) 3. The embrittlement of weld HAZ in SB 41 and SA 588 is influenced by hot strain, and the degree of embrittlement becomes deeper with hot straining amounts. 4. The embrittlement of weld HAZ of SB 41 is not influenced by the hot straining amounts until .epsilon. over bar $_{max}$ = 0.36, $R_{\chi}$ = 0.065mm, however the embrittlement of structure in SA 588 is considerably influenced even by a small quantity of the hot straining amounts.s.

  • PDF

The Experimental Study on GCM(General Coordinative Manipulation) which has been studied on the basis of Spine & Limb Extremity (인체 사지 및 척추관절의 운동증감패턴에 따른 전신교정치료에 관한 실증적 연구)

  • Moon, Sang-Eun
    • Journal of Korean Physical Therapy Science
    • /
    • v.6 no.2
    • /
    • pp.1041-1062
    • /
    • 1999
  • This study is to stimulate the model of which top notch muscle stimuli physical therapy has been made on the basis of GCM. GCM has been studied on the hypermobility & hypomobility pattern on the part of spine & extremity, and the body characteristics of four body types, which is the tilting of seal scapular & ilium. The purpose of this study is to analysize the type of GCM which has been focused on the spine & extremity for the patients having dysfunctions of neuromuscular system, being analysized the movement. The result of this study is as following; 1) The First hypothesis: The hypermobility & hypomobility pattern assorted by the tilting of scapular & ilium, as does the former study analysize was claimed that it would be in line with the pattern for hypermobility hypomobility and physical characteristics according to each body type at the percentage of at least 60(p<.001). 2) The 2nd hypothesis : Stimuli therapy of muscle dealing with physical characteristics and joint hypermobility hypomobility has the important role in restoring the deformity and keeping anatomical postural plumb alignment also it would a highly effects on correcting the body even though the stimuli area was limited to four areas and it was lack of time compared with those applied by general physical therapy(p<.001). As above the result, the top-notch type for physical therapy based on hypermobility hypomobility pattern by 4 body types which has been studied on tilting of scapular & ilium is more specificed and specialized than those of general physical therapy technologies. So this study will be believed to dedicate to restoration ideal anatomical postural plumb alignment based on spinal Manipulation and the concept of whole person as well as to being simple and effective to apply.

  • PDF

Implementation of Diplexer using Heterogeneous Dielectric Multilayer Organic Substrate (이종 유전율의 다층 유기물 기판을 이용한 diplexer 구현)

  • Lee, Jae-Yong;Moon, Byung-Moo;Park, Se-Hoon;Yoo, Chan-Sei;Lee, Woo-Sung;Kim, Jun-Chul;Kang, Nam-Kee;Park, Jong-Chul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.36-36
    • /
    • 2007
  • 본 논문에서는 SoP-L(System on Package-Laminates) 기술을 이용하여 이종의 유전율을 가진 유기물 적층 기반의 수동소자를 이용한 GSM/DCS 대역 분리용 diplexer를 설계, 제작하였고 그 특성을 고찰하였다. SoP-L 기술은 LTCC기술과 같은 타 SoP 기술과 비교해서 이종의 물질을 접합하는데 용이하고 공정비용이 저렴하다. 이러한 장점을 이용하여 캐때시터는 유전율 40의 고유전율 재료를 사이에 두고 구성하였고, 인덕터 부문에는 유전율 4률 적용, 정방혈 스파이럴 구조로 두 개 층으로 구성하여 소형화를 이룰 수 있었다. 제작 시에 구리와 유기물을 적층, patterning 하였고, 수직 via hole 을 형성하고 구리의 무전해, 전해 도금 과정을 거쳐 각 소자를 연결하였다. 이러한 과정을 거쳐 제작된 diplexer의 GSM 저역 통과 필터는 0.52 dB이하의 삽입손실과 20 dB 이상의 반사손실을 가지고 DCS 통과 대역 부근에 notch 가 존재하도록 설계함으로써 DCS 통과 대역에서 17 dB 이상의 저지특성을 나타내었다. DCS 고역 통과 필터는 1.2 dB 이하의 삽입손실과 16 dB 이상의 반사손실을 가지며 GSM 통과 대역 부근에 notch를 가지도록 설계하여 GSM 통과대역에서 32 dB 이상의 저지특성을 나타내었다.

  • PDF

Material Properties of 400MPa Grade Hot Rolled H-beam(SHN400) for Building Structure (400MPa급 건축구조용 열간압연 H형강(SHN400)의 소재 특성)

  • Kim, Hee-Dong;Choi, Byoung-Jeong;Kim, Sang-Sub;Kim, Chul-Hwan;Oh, Young-Suk
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.4
    • /
    • pp.515-522
    • /
    • 2011
  • The purpose of this study was to evaluate the material characteristics of SHN400 steel, which is suitable as a steel material for building structures, using the experimental approach. For this purpose, the chemical composition test, tensile test, macro test, micro test, and charpy notch impact test were conducted with specimens taken from the highest, thickest, and commonly used H-beams for girder or beam members. Each test was conducted under the Korean Standard(KS) test conditions. All the test results satisfied the requirements of KS (KS D 3866) and the steel material for seismic design. The carbon equivalent value (Ceq), which is related to weldability, and the yield ratio, which is related to inelastic behavior, showed especially good results. Thus, SHN400 is definitely suitable as the steel material for building structures.