• Title/Summary/Keyword: NORSOK

Search Result 19, Processing Time 0.026 seconds

Sound Insulation Measurement and Evaluation for Cabin Unit Mock Up in Vessel Satisfying NORSOK Standard (NORSOK 적용 선박의 Cabin Unit Mock Up 차음성능 계측평가)

  • Park, Jin-Hyung;Park, Hyung-Sik;Park, No-Jun;Kwun, Hyuk;Suh, Yong-Suk;Seo, Jong-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.18-19
    • /
    • 2014
  • NORWAY 해역에서 시추 및 생산 작업을 위한 시추선 및 생산 설비의 경우, 엄격한 기준인 NORSOK 기준을 만족해야 한다. NORSOK 기준은 선원들의 안전과 안락성을 위한 Working Environment 만족을 요구하고 있다. 특히 선원들의 거주구역에 안락성은 더욱 중요시되고 소음의 기준을 제시하고 만족을 요구한다. Cabin Unit 이 적용되는 선박의 경우 실선과 동일 조건의 Mock Up 을 제작하여 차음성능 계측 및 평가를 실시한다. 본 논문에서는 NORSOK 이 적용되는 선박의 Cabin Unit 의 Mock Up 차음성능 만족 사례를 소개하고자 한다.

  • PDF

Development of NORSOK T-100-based telecom management system for off-shore installation (NORSOK T-100 기반의 해양플랜트용 TMS 응용 소프트웨어 개발)

  • Mun, Seong-Mi;Jang, Won-Seok;Park, Su-Hyun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.3
    • /
    • pp.210-216
    • /
    • 2016
  • Malfunctioning of telecom systems can have serious implications on the safe navigation and operation of vessels and off-shore plants. Most safety-related accidents incur significant monetary damages and pollution due to complicated arrangements of the working environments and facilities. Therefore, an automated monitoring system that can collect data from configured telecom equipment connected to a network based on IP is required to ensure safe navigation and operation of such crucial institutions. This paper reports a list of such system requirements, system functions, and user-centered requirements based on the NORSOK T-100 (a standard of telecom management system). These findings were made through research with the newly designed and developed telecom management system (TMS). The TMS was tested by a testbed configured with CCTV, PA/GA, and other network equipment.

Evaluation of Corrosion Protection for Epoxy and Urethane Coating by EIS under Various Cyclic Corrosion Tests

  • Hyun, Jonghun;Shon, Minyoung
    • Corrosion Science and Technology
    • /
    • v.10 no.3
    • /
    • pp.95-100
    • /
    • 2011
  • Protective coatings play an important role in the protection of metallic structures against corrosive environment. The main function of anticorrosive coating is to prevent the materials from corrosive agents, such as water, oxygen and ions. In the study, the corrosion protection properties of urethane and epoxy coating systems were evaluated using EIS methods exposed to the corrosion acceleration test such as Norsok M501, Prohesion and hygrothermal cyclic test. AFM analysis of the coating systems was carried out to monitor the change of roughness of coatings. Urethane coating system was more stable than the epoxy coating under given cyclic conditions. Water uptake into the urethane coatings was less than that into the epoxy coating. The urethane coating system showed better corrosion protection than epoxy coating system based on the changes of the impedance modulus at low frequency region with exposure time. Consequently, the corrosion protection properties of the epoxy and urethane coatings was well correspond with their surface roughness changes and water uptakes.

Design of an integrated network management system for telecom subsystem in offshore plants

  • Kang, Nam-seon;Kim, Nam-hun;Lee, Seon-ho;Kim, Young-goon;Yoon, Hyeon-kyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.8
    • /
    • pp.863-869
    • /
    • 2015
  • This study analyzed the offshore plant industry and related regulations such as ISO, IEC, and Norsok Standards to develop an integrated network management system (INMS) capable of both on-site and remote management and configuration of IP-based network equipment in offshore plants. The INMS was designed based on actual specifications and POS plans, and a plan of management was verified through an offshore plant engineering company. Various modules such as PAGA interface modules, CCTV, IP-PBX, and HF-radio communication modules were developed for system implementation. Protocol and data design and screen design were followed by framework development and introduction of the automatic satellite communication function.

Development of the Vertical Ladder using a High-Strength Aluminium Alloys (6082-T6) (고강도 알루미늄 합금을 적용한 수직 사다리 개발 연구)

  • Kim, Jae-hyeong;Seo, Kwang-Cheol;Park, Joo-Shin
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.26 no.6
    • /
    • pp.698-705
    • /
    • 2020
  • In this study, an improved aluminum alloy (6082-T6) was used to develop a unique model of an aluminum ladder for usage in offshore plant. The structural strength design was carried out in accordance with international standards such as ISO, NORSOK Austria Standard. Load combination was performed to satisfy all conditions. The structural safety of the designed model was verified using SACS, an analysis program for offshore plants based on the Finite elements method. The analysis results confirmed that both stress and deflection were satisfied within the acceptance criteria. The developed model can be applied used in various fields in the near future as it meets all the necessary criteria and is lightweight and has improved productivity.

Weathering Performance Evaluation of Duplex Coating Systems of Thermal Spraying and Painting using Corrosion Test (부식실험에 의한 금속용사와 도장의 복합피복방식법의 내후성능평가)

  • Kim, In Tae;Kim, Ho Seob;Kien, Dao Duy;Jun, Je Hyeong;Ahn, Jin Hee
    • Journal of Korean Society of Steel Construction
    • /
    • v.28 no.2
    • /
    • pp.97-108
    • /
    • 2016
  • Thermally sprayed metals or organic coatings is often used in corrosion protection of steel structures. Duplex coating systems of thermally sprayed metal in combination with organic coating are selected as a new generic type of coatings on steel structures under the highly corrosive environments. In this study, three types of corrosion tests were carried out on four types of thermal sprayed specimens with sealing: zinc, zinc-15%aluminum alloy, aluminum and aluminum-5%magnesium alloy, four types of duplex coated specimens; thermally sprayed metals in combination with paint of acrylic urethane, and painted specimens. NORSOK M-501, Wet/dry cyclic seawater tests and outdoor exposure tests of nine types of specimens were conducted. From the corrosion test results, weathering performance of them were presented.

Valve induced noise and vibration evaluation procedure for process piping of offshore production facility (Offshore 선 Process 배관계의 밸브 소음/진동 평가 절차)

  • Lee, JooHun;Choi, ChoongYoung;Kim, JaeHong;Kwun, Hyuk
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.04a
    • /
    • pp.201-204
    • /
    • 2014
  • Recent year, the vibration induced fatigue and noise of piping work become critical in offshore hydrocarbon production facilities with increasing requests by major oil company. In this paper, the risk base piping vibration induced fatigue assessment of NORSOK L-002 standard and UK Energy Institute guideline have been introduced with real project application practice. Also the piping breakout noise evaluation by flow restriction devices of compressible and in-compressible flow are reviewed with its practical application on real project.

  • PDF

An experimental study for the evaluation of airborne sound insulation performance of the small window (소형 창문의 차음 성능 평가에 관한 실험적 고찰)

  • Choi, Dool;Moon, Soon-Sung;Goo, Hee-Mo;Kim, Hang;Park, Hyeon Ku
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.1-1
    • /
    • 2014
  • Side scuttle in the shipboard windows is used in a smaller size in order to prevent damage to the glass. This shipboard windows should have high sound insulation performance (More than $R_w$ 53 dB) according to norsok standards. However, side scuttle having a small size and high sound insulation material is difficult to measure exact result without a suitable filler wall. In this study, the test was conducted according to the number of changes in the small window. As a result, before starting the test should be conducted to the selection of the suitable filler wall or secure a specimen area.

  • PDF

Study of Living Quarter Fire Protection for PSA AoC (PSA AoC 획득을 위한 Living Quarter Fire Protection 고찰)

  • Heo, Jun
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2015.09a
    • /
    • pp.96-99
    • /
    • 2015
  • Norwegian Continental Shelf(NCS) is known as rich oil & gas reservoir and takes one third(1/3) of total continental shelf of Europe.(As of year 2013, Norway ranked third in the world in terms of exporting natural gas.) Until recent low oil price stream, development of oil & gas in NCS was active and perceived as profitable business. This paper describes study of living quarter fire protection for PSA AoC to prepare for likely increasing demands of offshore projects in NCS field.

  • PDF

Evaluation of Deterioration of Epoxy Primer for Steel Bridge Coating using Image Processing and Electrochemical Impedance Spectroscopy (화상처리 기법과 전기화학적 임피던스 분광법을 이용한 강교 도장용 에폭시 하도 도료의 열화 평가)

  • Lee, Chan Young;Lee, Sang Hun;Park, Jin Hwan
    • Corrosion Science and Technology
    • /
    • v.8 no.2
    • /
    • pp.53-61
    • /
    • 2009
  • In this study, both evaluations by visual imaging for exterior view of coating and by EIS were executed for epoxy primer coated specimens deteriorated by accelerated test, and comparison and analysis were carried out for 2 evaluation methods. In the comparison between total damaged area ratio acquired by image processing method and deterioration point, higher deterioration points were appeared for rusted specimens than for non-rusted specimens. It is attributed that deterioration point per unit area ratio given for rust is higher than for peeling. In the comparison between total damaged area ratio and EIS result, impedance of coating was largely decreased as about TEX>$10^4{\Omega}{\cdot}cm^2$ or less when rust area ratio is more than about 0.1%, and blistering area ratio is more than about 3%. Charge transfer resistance ($R_{ct}$) and double layer capacitance ($C_{dl}$) values were appeared for all specimens except 2 ones, which shows that water is accumulated and steel substrate is corroded at coated film-steel interface. In the comparison between deterioration point and EIS result, more than 10 points as deterioration point were given for specimens of below $10^6{\Omega}{\cdot}cm^2$ of impedance at low frequency. For specimens deteriorated by NORSOK cyclic test, impedance was lowest of all, though deterioration point was not high. It is thought to be attributed that coating system and accelerated deterioration condition of cyclic tested specimens were different from those of main specimens. From the result, it is thought that coating resistance can be relatively more decreased than deterioration degree estimated from exterior view under more severe corrosion environment or in the present of more complex deterioration factors.