• Title/Summary/Keyword: NO gas sensor

Search Result 229, Processing Time 0.023 seconds

A Numerical Study on the Smoke Behavior by Solar Radiation through Ceiling Glass in Atrium Fires

  • Jeong, Jin-Yong
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.10 no.3
    • /
    • pp.117-128
    • /
    • 2002
  • This paper describes the smoke filling process of a fire field model based on a self-deve-loped SMEP (Smoke Movement Estimating Program) code to the simulation of fire induced flows in the two types of atrium space containing a ceiling heat flux. The SMEP using PISO algorithm solves conservation equations for mass, momentum, energy and species, together with those for the modified k-$\varepsilon$ turbulence model with buoyancy production term. Also it solves the radiation equation using the discrete ordinates method. Compressibility is assumed and the perfect gas law is used. Comparison of the calculated upper-layer average tempera-ture and smoke layer clear height with the zone models has shown reasonable agreement. The zone models used are the CFAST and the NBTC one-room. For atrium fires with ceiling glass the ceiling heat flux by solar heat causes a high smoke temperature near the ceiling. However, it has no effect on the smoke movement such as the smoke layer clear heights that are important in fire safety. In conclusion, the smoke layer clear heights that are important in evacuation activity except the early of a fire were not as sensitive as the smoke layer tem-perature to the nature of ceiling heat flux condition. Thus, a fire sensor in atrium with ceiling glass has to consider these phenomena.

Fabrication of ZnO :AI, In Thin Film $NH_3$ Gas Sensor and Its Characteristics (Al과 In이 도핑된 ZnO 박막 $NH_3$ 가스센서의 제작과 검지 특성에 대한 연구)

  • Kim, Gwon-Tae;Kim, Jin-Hae;Kim, Jeong-Gyoo;Park, Ki-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1710-1712
    • /
    • 1999
  • 암모니아가스에 민감한 In이 도핑된 ZnO(ZnO:In) 박막을 In 박막$(100{\AA})$ 및 ZnO박막$(3000{\AA})$의 연속적인 증착과 열처리공정을 통하여 제조하고, 이와 같은 방법으로 Al과 In이 도핑된 ZnO (ZnO:Al, In) 박막을 In 박막과 ZnO:Al 박막의 연속적인 증착과 같은 조건에서의 열처리를 통하여 제조하였다. 기판은 $1000{\AA}$의 산화막이 열적으로 성장되어 있는 Si 기판을 사용하였다. In/ZnO 및 In/ZnO:Al 박막 이중층의 열처리온도에 따른 구조적 및 전기적 특성을 x-선회절기, 주사전자현미경, 오제전자분광법 및 4점측정시스템을 통하여 조사하였다. 이들 막에 대하여 열처리온도에 따른 암모니아가스에 대한 감도, 선택성 및 시간응답특성을 구하였다. 열처리온도 $400^{\circ}C$, 동작온도 $300^{\circ}C$에서 100 ppm의 암모니아가스를 주입한 결과 140 %의 최대감도를 나타내었으며 CO, $NO_x$ 가스에 대한 감도는 아주 낮은 것으로 나타났다.

  • PDF

Highly Ordered Porous Silica Adsorbent with Dual Pore Size Regime for Bulky VOC Gas Sensing

  • Yun, Ji Sun;Jeong, Young Hun;Nam, Joong-Hee;Cho, Jeong-Ho;Paik, Jong-Hoo
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.3
    • /
    • pp.181-184
    • /
    • 2013
  • Highly ordered porous materials having mesopores in the walls of macropores showed improved adsorption dynamics results for VOC molecules, especially bulky molecules. These meso/macroporous mataerials were synthesized by the dual templating method, and mesopore and macropore size were controlled by adjusting the templates for each pore size regime. In the case of adsorption and desorption of small VOC molecules (toluene), although meso/macroporous MCM-41 with smaller mesopore size showed improved results, meso/macroporous SBA-15 with larger mesopore size was not improved regardless of the existence of macropores, since there was no limitation of movement through the larger mesopore. However, the adsorption dynamics of bulky VOC molecules (p-xylene) over meso/macroporous SBA-15 were drastically improved by increasing the macropore size.

Remote Measurement for ECU Self Diagnostic Signal by RF Module (RF 모듈을 이용한 ECU 자기진단 신호의 원격 계측)

  • 정진호;이영춘;윤여흥;권대규;이우열;이성철
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.231-234
    • /
    • 2001
  • OBD-II regulations are already effective in many countries. The California Air Resources Board(CARB) first issued regulations in 1985 for the 1988 model year, known as OBD-I, and required the vehicle's engine management computer to warn the driver by means of a dash-mounted light if a malfunction occurred in either the oxygen sensor, the exhaust gas recirculation(EGR) valve or the evaporative emission system purge solenoid, and to store information on troubles that have no recurrent characteristics. This paper presents two methods of wireless monitoring OBD signal, which is one of the ECU output for self diagnostic measurement. RF module is used to monitor ECU's Self diagnostic signal remotely. Two kinds of measurement systems which are based on micro-controller(80C196KC) for portable detection and PC for sever are considered for receiving the RF signal. Therefore, possibility of real-time monitoring of ECU's self diagnostic signal remotely is verified on this paper.

  • PDF

The Volume Measurement of Air Flowing through a Cross-section with PLC Using Trapezoidal Rule Method

  • Calik, Huseyin
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.4
    • /
    • pp.872-878
    • /
    • 2013
  • In industrial control systems, flow measurement is a very important issue. It is frequently needed to calculate how much total fluid or gas flows through a cross-section. Flow volume measurement tools use simple sampling or rectangle methods. Actually, flow volume measurement process is an integration process. For this reason, measurement systems using instantaneous sampling technique cause considerably high errors. In order to make more accurate flow measurement, numerical integration methods should be used. Literally, for numerical integration method, Rectangular, Trapezoidal, Simpson, Romberg and Gaussian Quadrature methods are suggested. Among these methods, trapezoidal rule method is quite easy to calculate and is notably more accurate and contains no restrictive conditions. Therefore, it is especially convenient for the portable flow volume measurement systems. In this study, the volume measurement of air which is flowing through a cross-section is achieved by using PLC ladder diagram. The measurements are done using two different approaches. Trapezoidal rule method is proposed to measure the flow sensor signal to minimize measurement errors due to the classical sampling method as a different approach. It is concluded that the trapezoidal rule method is more effective than the classical sampling.

Nano Porous Tin Oxide Film Fabricated by Anodization (양극산화법으로 제작된 나노 다공성 주석 산화물 박막)

  • Mun, Kyu-Shik;Cheon, Se-Jon;No, Hee-Kyu;Chun, Seung-Chul;Park, Sung-Yong;Lee, Ro-Un;Park, Yong-Joon;Choi, Won-Youl
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.328-328
    • /
    • 2007
  • $SnO_2$ has a high potential for electric and electronic applications. We have anodized pure tin metal and nano porous tin oxide film was obtained on pure Sn. Nano porous tin oxide were grown by anodization in nonaqueous-base electrolytes at different potentials between 5 V and 100 V. Pore size of ~100nm was observed by FE-SEM. Pore sizes as a function of applied voltage and anodizing time were characterized. We obtained nano porous tin oxide film having an uniform pore size at low temperature. High specific surface area of $SnO_2$ will be very useful for gas sensor, lithium battery, and dye sensitized solar cell.

  • PDF

Preparation of Zinc Oxide Thin Film by CFR Method and its Electrical Property for Detection of Sulfur Compounds (CFR 법에 의한 산화아연 박막의 제조 및 황 화합물 검출을 위한 전기적 특성)

  • Lee, Sun Yi;Park, No-Kuk;Yoon, Suk Hoon;Lee, Tae Jin
    • Korean Chemical Engineering Research
    • /
    • v.48 no.2
    • /
    • pp.218-223
    • /
    • 2010
  • The zinc oxide thin film, which can be applied as the gas sensor of a semiconductor type, was grown on the silicon substrate by CFR(continuous flow reaction) method in this study. The growth property and the electrical property of the zinc oxide thin films synthesized by CFR method were also investigated. Zinc acetate solutions of 0.005~0.02 M were used as the precursor for the preparation of zinc oxide thin films. The size of ZnO particles consisted on the zinc oxide thin film increased not only with increasing concentration of precursor, but also the thickness of thin film increased. The growth rate of zinc oxide thin film by CFR method was proportionably depend on the concentration of precursor and the uniform ZnO thin film was prepared when zinc acetate of 0.01 M is used as the precursor. The charged currents on the zinc oxide thin films were obtained as its electrical property by I-V meter, and increased agree with increasing the thickness of zinc oxide thin film. Thus, it was concluded that the charged current on the zinc oxide thin film can be controlled with changing concentration of precursor solution in CFR method. The charged currents on the zinc oxide thin films also decreased when ZnO thin film is exposed under hydrogen sulfide of 500 ppmv at $300^{\circ}C$ for 5 min. From these results, it could be confirmed that the zinc oxide thin film prepared by CFR method can be used for the detection of sulfur compounds.

Effects of Process Variables on the Microstructure and Gas Sensing Characteristics of Magnetron Sputtered $\textrm{SnO}_2$Thin Films (마그네트론 스퍼터링 증착 조건에 따른 $\textrm{SnO}_2$ 박막의 미세구조와 가스검지특성 변화)

  • Kim, Jong-Min;Moon, Jong-Ha;Lee, Byung-Teak
    • Korean Journal of Materials Research
    • /
    • v.9 no.11
    • /
    • pp.1083-1087
    • /
    • 1999
  • Microstructures and the gas-sensing characteristics of the $\textrm{SnO}_2$ thin films were studied, which were deposited at various conditions (rf power, sample temperature, $\textrm{O}_2$/Ar ratio) by the rf magnetron sputtering. As a result, six typical microstructures were derived, such as amorphous(A), amorphous mixed with polycrystalline grains (A+P), polycrystalline with random crystalographic orientation (P), fine columnar (FC), coarse columnar (CC) and Zone T (T) with dense fiberous structure. Typically, A, A+ P, and P structures were formed when no $\textrm{O}_2$ was added to the sputter gas, whereas FC, CC, and T structures were obtained when $\textrm{O}_2$ was added. The A structure formed at low rf power and low temperature, the A+P at high rf power and low temperature, and the P at high rf power and high temperature. The FC structure was obtained at low rf power and low temperature. the CC at low rf power and high temperature, and the T at high rf power and low temperature. Results of the gas-sensing test of the sensor chips fabricated from the typical films indicated that the fine columnar microstructure shows the highest sensitivity both at $300^{\circ}C$ and $400^{\circ}C$. It was proposed that this is due to the high specific surface area of the micro-columns.

  • PDF

Micromachined Multiple Gas Sensor for Automotive Ventilation and Air Conditioning Systems (미세기계가공된 자동차 HVAC 시스템용 다중 가스센서)

  • Choi, W.S.;Lee, S.H.;Kim, S.D.;Park, J.S.;Park, H.D.;Min, N.K.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1637-1638
    • /
    • 2006
  • HVAC 시스템은 쾌적하고 깨끗한 운전환경을 만들어 줌으로써 운전자에게 향상된 안락성과 안전성을 제공한다. 이때 센서는 시시각각으로 변화하는 차실 내외의 환경변화에 대한 정보를 검출하여 HVAC 제어 유니트에 제공한다. 현재 HVAC 시스템에 사용되고 있는 후막 가스센서는 소자 크기와 소비전력이 크고, 제작공정이 까다로워 생산성이 낮은 단점이 있다. 이와 같은 문제점을 해결하기 위해서 최근에는 초소형화, 저소비전력, 대량생산에 의한 저가격화가 가능한 MEMS 가스센서의 연구개발이 활발히 진행되고 있다. 본 연구에서는 MEMS 구조체를 이용한 마이크로 가스센서를 설계 및 제작하였고, 감도특성을 고찰하였다. 가스 감지막은 금속산화물 페이스트를 스크린 프린팅 하는 종래의 방법 대신 MEMS 구조체에 적용 가능한 sol-gel 프로세스에 의해 형성하였다. 또 가스 감지전극과 micro-heater를 동일 평면상에 제작, 공정을 간소화하여 저가화를 시도하였다. MEMS 구조체 위에 제작된 Pt 박막 micro-heater의 인가전압에 따른 발열특성을 조사한 결과, 발열온도가 인가전압에 비례하는 이상적인 선형성을 나타내었으며, $300^{\circ}C$의 동작 온도에 도달하기 위해 65mW 이하의 저전력 동작이 가능하였다. 가스 센서의 감도특성 확인 실험은 CO 가스 10ppm, NO 가스 0.3ppm을 기준으로 수행되었으며, CO 및 NO에 대해 Rs(sensitivity, 가스반응저항/초기저항) 값은 각각 0.753 과 2.416로 우수한 성능을 나타내었다.

  • PDF

Partial Discharge Detection of High Voltage Switchgear Using a Ultra High Frequency Sensor

  • Shin, Jong-Yeol;Lee, Young-Sang;Hong, Jin-Woong
    • Transactions on Electrical and Electronic Materials
    • /
    • v.14 no.4
    • /
    • pp.211-215
    • /
    • 2013
  • Partial discharge diagnosis techniques using ultra high frequencies do not affect load movement, because there is no interruption of power. Consequently, these techniques are popular among the prevention diagnosis methods. For the first time, this measurement technique has been applied to the GIS, and has been tested by applying an extra high voltage switchboard. This particular technique makes it easy to measure in the live state, and is not affected by the noise generated by analyzing the causes of faults ? thereby making risk analysis possible. It is reported that the analysis data and the evaluation of the risk level are improved, especially for poor location, and that the measurement of Ultra high frequency (UHF) partial discharge of the real live wire in industrial switchgear is spectacular. Partial discharge diagnosis techniques by using the Ultra High Frequency sensor have been recently highlighted, and it is verified by applying them to the GIS. This has become one of the new and various power equipment techniques. Diagnosis using a UHF sensor is easy to measure, and waveform analysis is already standardized, due to numerous past case experiments. This technique is currently active in research and development, and commercialization is becoming a reality. Another aspect of this technique is that it can determine the occurrences and types of partial discharge, by the application diagnosis for live wire of ultra high voltage switchgear. Measured data by using the UHF partial discharge techniques for ultra high voltage switchgear was obtained from 200 places in Gumi, Yeosu, Taiwan and China's semiconductor plants, and also the partial discharge signals at 15 other places were found. It was confirmed that the partial discharge signal was destroyed by improving the work of junction bolt tightening check, and the cable head reinforcement insulation at 8 places with a possibility for preventing the interruption of service. Also, it was confirmed that the UHF partial discharge measurement techniques are also a prevention diagnosis method in actual industrial sites. The measured field data and the usage of the research for risk assessment techniques of the live wire status of power equipment make a valuable database for future improvements.