• Title/Summary/Keyword: NO conversion

Search Result 1,594, Processing Time 0.025 seconds

Effect of Cholecystokinin-pancreozymin on the Nitric Oxide Synthase Activity and Cyclic GMP Level in Rat Pancreatic Tis-sue

  • Seo, Dong-Wan;Nam, Suk-Woo;Nam, Tae-Kyun;Lee, Young-Jin;Ko, Young-Kwon;Lee, Hyang-Woo
    • Archives of Pharmacal Research
    • /
    • v.18 no.6
    • /
    • pp.434-439
    • /
    • 1995
  • In pancreatic cells, NO formation is associated with increased levels of cGMP and endocrine/exocrine secretion. In the present study, the role of NO in the regulation of exocrine secretion was investigated in rat pancreatic tissues. Treatment of rat pancreatic tissue with sholecystokinin-pancreozymin (CCK-PZ) resulted in an significant increase in arginine conversion to citruline, the amount of nitrite/nitrate, the release of amylase, and the level of cGMP. Furthermore, CCK-PZ stimulated increase of amylase release and conversion of arginine to citrulline transformation were counteracted by the inhibitor of NO synthase, $N^G-nitro-L-arginine$ methyl ester. The results on the time course of CCK-PZ-induced citrulline formation within the first seconds of simulation. The kinetics of citrulline accumulation correlate well with those of cGMP rise, which further confirms the conclusion that NO mediates the response to CCK-PZ by cGMP.

  • PDF

Nursing Delivery System Improvement Plan in A Hospital (간호전달 체계 개선 방안 - 일 병동을 중심으로 -)

  • Lee, Jin-Hi;Lee, Sung-Ae;Ham, Yong-Hee;Yang, Myong-Ju;Kim, Ok-Sohn
    • Quality Improvement in Health Care
    • /
    • v.3 no.2
    • /
    • pp.52-59
    • /
    • 1997
  • Background : In many Nursing Delivery System, Nursing Department at D Hospital had used to traditional nursing practice model what is called functional activities based system. It has a lot of merit that carried out specialized and rapid works but tend to ignore indivisual professional responsibility and task-based work assignments. In addition this system showed high turnover rates due to heavy workload, timesum of handing over duties, lack of support from peers and interstaff communication. So we performed conversion of Nursing Delivery System to My Patients Nursing Care System for providing comprehensive nursing to patient and reducing turnover rates and increasing job satisfaction to nurse. Method : 1. 1st step(96.4.9): Detected the problem of Nursing delivery System and estabilished improving planning 2. 2nd step(96.4.26): Visited other hospital on job training 3. 3th step(96.4.29): Discussed to premonitoring problem after conversion Nursing Delivery System and prepared structure 4. 4th step(96.5.6): My Patients Nursing Care System practical application 5. 5th step(96.7.20): Held complementary meeting 6. 6th step(96. 7): The other ward application 7. 7th step(96. 10): Extended application to whole wards Results: 1. Workload: (1) reduction(55.6%) (2) addition(44.4%) 2. Strong points after conversion: (1) decreased timesum of handing overduties (35.2%) (2) increased responsibility(33%) (3) broaden nurse's outlook to duties(14.8%) 3. Shortcoming after conversion: (1) understanding difficulties except my patient(57.8%) (2) weak teamwork(23.3%) (3) intensive stress to low grade nurse(12.2%) 4. Effective complemental way: (1) manpower(76.7%) (2) conversion of though (8.9%) (3) education(14.4%) 5. Patient's satisfaction: (1) satisfaction(64%) (2) no effect(36%) 6. Physician and peer's satisfaction: (1) satisfaction(12.5%) (2) dissatisfaction(21.6%) (3) no interest(44.3%) 7. Nurse's satisfaction: (1) satisfaction(74.7%) (2) dissatisfaction(5.5%) (3) unknown(20.5%) 8. Want to continued: (1) want(76.4%) (2) try to any other system(18%) Conclusion : Even though Nursing Delivery System conversion still has many problem, we gained more merits than traditional nursing delivery system. So we suggest that My Patients Nursing Care System should be encouraged for comprehensive nursing care and satisfaction to nurses.

  • PDF

Relationship between Land-Use Change and Soil Carbon and Nitrogen (토지(土地) 이용(利用) 형태(形態)의 변화(變化)와 토양(土壤) 내(內) 탄소(炭素)와 질소(窒素의 관계(關係))

  • Son, Yowhan;Lee, Sook Hee
    • Journal of Korean Society of Forest Science
    • /
    • v.90 no.3
    • /
    • pp.242-248
    • /
    • 2001
  • Changes in land-use can affect soil organic matter content and fertility. We compared total soil carbon and nitrogen concentrations, soil respiration, and nitrogen availability under three land-use types in central Korea; conversion of old rice field to natural willow-maple (Salix-Acer) forest, conversion of old field to artificial Korean pine (Pines koraiensis) forest, and indigenous oak (Quercus spp.) forest. After 20 years of fallow the area of rice field conversion to forest had higher soil carbon and nitrogen concentrations in the soil depth of 0-10cm and 10-20cm than the areas of field conversion to Korean pine forest and indigenous forest. In general, soil carbon and nitrogen concentrations decreased with soil depth. Organic matter accumulation as a balance of input and decomposition seemed to be higher in the soil of previous rice field, and carbon and nitrogen accumulation was largely confined to the topsoil. Soil respiration rates were greatest at the area of rice field conversion to forest, and appeared to be related to soil carbon and soil moisture. Soil nitrogen availability measured by the ion exchange resin bag method differed significantly among land-use types; soil inorganic nitrogen ($NH_4{^+}+NO_3{^-}$) and ammonium availability were highest in the soil under indigenous oak forest followed by conversion of old field to artificial Korean pine forest and conversion of old field to natural willow-maple forest.

  • PDF

The Power Conversion System of a Sterilizer Processing for the Long Term Storage of Flours (밀가루 장기보관을 위한 살균처리 전력변환시스템)

  • 강욱중;정상화;고강훈;서기영;이현우
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.6
    • /
    • pp.27-34
    • /
    • 2001
  • There are several electricity applied sterilizers such as using high frequency, ozone, high voltage, and so on. Those sterilizers feature "because of no chemical process and no secondly environmental pollution". At the power conversion part, ZVS and ZCS methods have been used that it results in reduced switching loss, miniaturized size, and lightened weight. Besides, the current in the propose device is smaller than that of existing method. Thus, it is expected that the cost of sterilization process, when quality of the device is measured by power consumption, will be reduce. Therefore, the purpose of this research is to solve the sterilization problems of existing powder with high voltage and field to and more economical and effective way, and to suggest mere improved sterilizer.

  • PDF

The improvement of sterilization effective using resonance inverter Power conversion device (공진용 인버터 전력 변환 장치를 이용한 플라즈마 살균효과 개선)

  • Kim, J.Y.;Kim, Y.M.;Kwon, S.K.;Lee, H.W.;Suh, K.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2003.04a
    • /
    • pp.266-269
    • /
    • 2003
  • A sterilizer equipment by using electrical energy has merits that no process of chemical and no second environmental pollution. Also, the power conversion circuit for sterilizer equipment has merits that are reducing switching loss for soft switching topology by using zero current and zero voltage switching, and miniaturizing size of equipment. Thus, it is expected that the cost of sterilization process, when quality of the device is measured by power consumption, will be reduced. Therefore, the purpose of this research is to solve the sterilization problems of existing powder with plasma sterilization device, to find more economical and effective way, and to suggest more improved sterilizer.

  • PDF

High Step-Up Converter with Hybrid Structure Based on One Switch

  • Hwu, K.I.;Peng, T.J.
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.1566-1577
    • /
    • 2015
  • A novel high step-up converter is presented herein, which combines the conventional buck-boost converter, the charge pump capacitor and the coupling inductor. By doing so, a quite high voltage conversion ratio due to not only the turns ratio but also the duty cycle, so as to increase design feasibility. It is noted that the denominator of the voltage conversion ratio is the square of one minus duty cycle. Above all, there is no voltage spike across the switch due to the leakage inductance and hence no passive or active snubber is needed, and furthermore, the used switch is driven without isolation and hence the gate driving circuit is relatively simple, thereby upgrading the industrial application capability of this converter. In this paper, the basic operating principles and the associated mathematical deductions are firstly described in detail, and finally some experimental results are provided to demonstrate the effectiveness of the proposed high step-up converter.

Synthesis of Ga-silicate and Its Catalytic Performance for NO Removal under the Presence of Water

  • Misook Kang;Yoon, Yong-Soo;Um, Myeong-Heon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.E
    • /
    • pp.1-8
    • /
    • 1999
  • Catalytic performance for NOx removal by Ga-incorporated silicates(Ga-silicate; Gallosilicate) with MFI type synthesized by the rapid crystallization method was reported in this study. NOx removal was investigated under the condition of O2 excess(10%), with various hydrocarbons of low concentrations. Effect of H2O(2%) addition was also considered. The result showd that the conversion from NOx to N2 was enhanced on the Ga-silicate compared with the Al-silicate. Furthermore, the performance for NOx conversion on the Ga-silicate increased with addition of water.

  • PDF

A Novel Integrated Battery Charger Structure for Multiple Charge and V2G application for Electric Vehicles (전기자동차의 다중충전 및 V2G 응용을 위한 새로운 통합 배터리 충전기구조)

  • Vu, Hai-Nam;Choi, Woojin
    • Proceedings of the KIPE Conference
    • /
    • 2016.11a
    • /
    • pp.13-14
    • /
    • 2016
  • This paper has introduces a novel Integrated On-board Charger (IOBC) to reduce the size, weight and cost of power conversion stages in Electric Vehicles (EVs). The IOBC is composed of an OBC and a low voltage dc-dc converter (LDC). The IOBC includes a bidirectional ac-dc converter and a bidirectional full-bridge converter with an active clamp circuit. The LDC converter is a hybrid topology combining an active clamped full-bridge converter and a forward converter derived from the Weinburg converter topology. Unlike conventional OBC, the proposed IOBC is compact and the LDC converter of it can achieve a higher efficiency. In addition, the LDC converter of the proposed IOBC can achieve high step-down voltage conversion ratio, no circulating current, no reverse recovery current of the rectifier diodes and small ripple current of output inductor on the auxiliary battery. A 1kW hardware of the LDC converter is implemented to verify the performances of the proposed IOBC.

  • PDF

Analytic equation to energy conversion between electromagnetically coupled superconducting and copper coils

  • An, Soobin;Choi, Kibum;Bang, Jeseok;Bong, Uijong;Hahn, Seungyong
    • Progress in Superconductivity and Cryogenics
    • /
    • v.21 no.1
    • /
    • pp.36-39
    • /
    • 2019
  • This paper presents an analytic method to calculate energy conversion between electromagnetically coupled high-temperature superconducting and copper coils. The energy transfer from one coil to the other is commonly observed during quench of a no-insulation (NI) high temperature superconductor (HTS) magnet. Proper understanding of this phenomenon is particularly important to protect an NI HTS magnet, especially to avoid any potential mechanical damages. In this paper, analytic equations are obtained to estimate the energy transfer between the NI and copper coils. The well-known lumped-parameter circuit model is adopted provided that key parameters of the coils are given.

Enhancement of Photoelectric Efficiency in a Dye-sensitized Solar Cell Using Hollow TiO2 Nanoparticles as an Overlayer

  • Lee, Kyoung-No;Kim, Woo-Byoung;Lee, Caroline Sunyong;Lee, Jai-Sung
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.6
    • /
    • pp.1853-1856
    • /
    • 2013
  • $TiO_2$ hollow nanoparticles (HNPs) and their light scattering effect which influences on the photoelectric conversion efficiency of a dye-sensitized solar cell (DSSC) were investigated. When only HNPs were employed in DSSC as the anode layer material, the conversion efficiency (e.g., 0.96%) was the lowest, possibly due to scattering loss of incident light. However, DSSC fabricated by using HNPs as a scattering overlayer on the $TiO_2$ nanoparticles (P-25), showed higher conversion efficiency (4.02%) than that without using HNPs (3.36%).