• Title/Summary/Keyword: NIR spectroscopy

Search Result 466, Processing Time 0.024 seconds

Hydrothermal Synthesis of Metal-doped BiVO4 Powder and its Thermochromic Properties (금속이 도핑된 BiVO4 분말의 수열 합성 및 이의 열 변색 특성)

  • Wu, Guan Zhu;Son, Dae Hee;Jin, Young Eup;Lee, Gun-Dae;Park, Seong Soo
    • Applied Chemistry for Engineering
    • /
    • v.26 no.6
    • /
    • pp.681-685
    • /
    • 2015
  • In this study, pure $BiVO_4$ powder and metal-doped $M-BiVO_4$ (M = Mg, Cu) powder, well known as thermochromic materials, were prepared from a mixed aqueous solution of bismuth nitrate ($Bi(NO_3)_3$) and ammonium vanadate ($NH_4VO_3$) in autoclave by hydrothermal method. The crystal structure, microstructure, and thermochromic property of samples were analyzed using FE-SEM, FT-IR, XRD, DSC, UV-Vis-NIR spectroscopy and colorimeter. When heating samples above phase transition temperature, the color of $M-BiVO_4$ (M = Mg, Cu) sample was thermally changed more clearly than that of using only pure $BiVO_4$ sample.

IR Absorption Property in Nano-thick Nickel Silicides (저온에서 형성된 니켈실리사이드의 적외선 흡수 특성)

  • Han, Jeung-Jo;Song, Oh-Sung;Choi, Young-Youn
    • Korean Journal of Materials Research
    • /
    • v.19 no.4
    • /
    • pp.179-185
    • /
    • 2009
  • We fabricated thermally evaporated 30 nm-Ni/(20 nm or 60 nm)a-Si:H/Si films to investigate the energy-saving property of silicides formed by rapid thermal annealing (RTA) at temperatures of $350^{\circ}C$, $450^{\circ}C$, $550^{\circ}C$, and $600^{\circ}C$ for 40 seconds. A transmission electron microscope (TEM) and a high resolution X-ray diffractometer (HRXRD) were used to determine the cross-sectional microstructure and phase changes. A UVVIS-NIR and FT-IR (Fourier transform infrared spectroscopy) were employed for near-IR and middle-IR absorbance. Through TEM and HRXRD analysis, for the nickel silicide formed at low temperatures below $450^{\circ}C$, we confirmed columnar-shaped structures with thicknesses of $20{\sim}30\;nm$ that had ${\delta}-Ni^2Si$ phases. Regarding the nickel silicide formed at high temperatures above $550^{\circ}C$, we confirmed that the nickel silicide had more than 50 nm-thick columnar-shaped structures with a $Ni_{31}Si_{12}$ phase. Through UV-VIS-NIR analysis, nickel silicide showed almost the same absorbance in the near IR region as well as ITO. However, in the middle IR region, the nickel silicides with low temperature showed similar absorbance to those from high temperature silicidation.

The effect of PVT process parameters on the resistance of HPSI-SiC crystal (PVT 공법의 공정 변수가 고순도 반절연 SiC 단결정의 저항에 미치는 영향)

  • Jun-Hyuck Na;Min-Gyu Kang;Gi-Uk Lee;Ye-Jin Choi;Mi-Seon Park;Kwang-Hee Jung;Gyu-Do Lee;Woo-Yeon Kim;Won-Jae Lee
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.34 no.2
    • /
    • pp.41-47
    • /
    • 2024
  • In this study, the resistance characteristics of semi-insulating SiC single crystals grown using the PVT method were investigated, considering the purity level of SiC source powders used in PVT growth and the cooling procedure after crystal growth. Two β-SiC powders with different purities were employed, and the cooling rate after growth was adjusted to achieve various resistance values. 4-inch HPSI-SiC ingots were grown using the PVT method, utilizing SiC powders with low nitrogen concentration and relatively high nitrogen concentration. These ingots were then subjected to different cooling procedures to modify the cooling rate. Transmission/absorption spectra and crystal quality of the grown crystals were analyzed through UV/VIs/NIR spectroscopy and X-ray rocking curve analysis, respectively. Additionally, electrical properties were investigated through non-contact resistivity analysis to identify the dominant factors influencing resistivity properties.

DISEASE DIAGNOSED AND DESCRIBED BY NIRS

  • Tsenkova, Roumiana N.
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1031-1031
    • /
    • 2001
  • The mammary gland is made up of remarkably sensitive tissue, which has the capability of producing a large volume of secretion, milk, under normal or healthy conditions. When bacteria enter the gland and establish an infection (mastitis), inflammation is initiated accompanied by an influx of white cells from the blood stream, by altered secretory function, and changes in the volume and composition of secretion. Cell numbers in milk are closely associated with inflammation and udder health. These somatic cell counts (SCC) are accepted as the international standard measurement of milk quality in dairy and for mastitis diagnosis. NIR Spectra of unhomogenized composite milk samples from 14 cows (healthy and mastitic), 7days after parturition and during the next 30 days of lactation were measured. Different multivariate analysis techniques were used to diagnose the disease at very early stage and determine how the spectral properties of milk vary with its composition and animal health. PLS model for prediction of somatic cell count (SCC) based on NIR milk spectra was made. The best accuracy of determination for the 1100-2500nm range was found using smoothed absorbance data and 10 PLS factors. The standard error of prediction for independent validation set of samples was 0.382, correlation coefficient 0.854 and the variation coefficient 7.63%. It has been found that SCC determination by NIR milk spectra was indirect and based on the related changes in milk composition. From the spectral changes, we learned that when mastitis occurred, the most significant factors that simultaneously influenced milk spectra were alteration of milk proteins and changes in ionic concentration of milk. It was consistent with the results we obtained further when applied 2DCOS. Two-dimensional correlation analysis of NIR milk spectra was done to assess the changes in milk composition, which occur when somatic cell count (SCC) levels vary. The synchronous correlation map revealed that when SCC increases, protein levels increase while water and lactose levels decrease. Results from the analysis of the asynchronous plot indicated that changes in water and fat absorptions occur before other milk components. In addition, the technique was used to assess the changes in milk during a period when SCC levels do not vary appreciably. Results indicated that milk components are in equilibrium and no appreciable change in a given component was seen with respect to another. This was found in both healthy and mastitic animals. However, milk components were found to vary with SCC content regardless of the range considered. This important finding demonstrates that 2-D correlation analysis may be used to track even subtle changes in milk composition in individual cows. To find out the right threshold for SCC when used for mastitis diagnosis at cow level, classification of milk samples was performed using soft independent modeling of class analogy (SIMCA) and different spectral data pretreatment. Two levels of SCC - 200 000 cells/$m\ell$ and 300 000 cells/$m\ell$, respectively, were set up and compared as thresholds to discriminate between healthy and mastitic cows. The best detection accuracy was found with 200 000 cells/$m\ell$ as threshold for mastitis and smoothed absorbance data: - 98% of the milk samples in the calibration set and 87% of the samples in the independent test set were correctly classified. When the spectral information was studied it was found that the successful mastitis diagnosis was based on reviling the spectral changes related to the corresponding changes in milk composition. NIRS combined with different ways of spectral data ruining can provide faster and nondestructive alternative to current methods for mastitis diagnosis and a new inside into disease understanding at molecular level.

  • PDF

A Melon Fruit Grading Machine Using a Miniature VIS/NIR Spectrometer: 2. Design Factors for Optimal Interactance Measurement Setup

  • Suh, Sang-Ryong;Lee, Kyeong-Hwan;Yu, Seung-Hwa;Shin, Hwa-Sun;Yoo, Soo-Nam;Choi, Yong-Soo
    • Journal of Biosystems Engineering
    • /
    • v.37 no.3
    • /
    • pp.177-183
    • /
    • 2012
  • Purpose: In near infrared spectroscopy, interactance configuration of a light source and a spectrometer probe can provide more information regarding fruit internal attributes, compared to reflectance and transmittance configuration. However, there is no through study on the parameters of interactance measurement setup. The objective of this study was to investigate the effect of the parameters on the estimation of soluble solids content (SSC) and firmness of muskmelons. Methods: Melon samples were taken from greenhouses at three different harvesting seasons. The prediction models were developed at three distances of 2, 5, and 8 cm between the light source and the spectrometer probe, three measurement points of 2, 3, and 6 evenly distributed on each sample, and different number of fruit samples for calibration models. The performance of the models was compared. Results: In the test at the three distances, the best results were found at a 5 cm distance. The coefficient of determination ($R_{cv}{^2}$) values of the cross-validation were 0.717 (standard error of prediction, SEP=$1.16^{\circ}Brix$) and 0.504 (SEP=4.31 N) for the estimation of SSC and firmness, respectively. The minimum measurement point required to fully represent the spectral characteristics of each fruit sample was 3. The highest $R_{cv}{^2}$ values were 0.736 (SEP=$0.87^{\circ}Brix$) and 0.644 (SEP=4.16 N) for the estimation of SSC and firmness, respectively. The performance of the models began to be saturated when 60 fruit samples were used for developing calibration models. The highest $R_{cv}{^2}$ of 0.713 (SEP=$0.88^{\circ}Brix$) and 0.750 (SEP=3.30 N) for the estimation of SSC and firmness, respectively, were achieved. Conclusions: The performance of the prediction models was quite different according to the condition of interactance measurement setup. In designing a fruit grading machine with interactance configuration, the parameters for interactance measurement setup should be chosen carefully.

Evaluation of Feed Values for Whole Crop Rice Using Near Infrared Reflectance Spectroscopy (근적외선분광법을 이용한 사료용 벼의 사료가치 평가)

  • Kim, Ji Hye;Lee, Ki-Won;Oh, Mirae;Park, Hyung Soo
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.39 no.4
    • /
    • pp.292-297
    • /
    • 2019
  • In this study, whole crop rice samples were used to develop near-infrared reflectance (NIR) equations to estimate six forage quality parameters: Moisture, crude protein (CP), neutral detergent fiber (NDF), acid detergent fiber (ADF), Ash and relative feed value (RFV). A population of 564 whole crop rice representing a wide range in chemical parameters was used in this study. Undried finely chopped whole crop rice samples were scanned at 1 nm intervals over the wavelength range 680-2500 nm and the optical data recorded as log 1/Reflectance (log 1/R). NIRS calibrations were developed by means of partial least-squares (PLS) regression. The correlation coefficients of cross-validation (R2cv) and standard error of cross-validation (SECV) for whole crop rice calibration were 0.98 (SECV 1.81%) for moisture, 0.89 (SECV 0.50%) for CP, 0.86 (SECV 1.79%) for NDF, 0.89 (SECV 0.86%) for ash, and 0.84 (SECV 5.21%) for RFV on a dry matter (%), respectively. The NIRS calibration equations developed in this study will be useful in predicting whole crop rice quality for these six quality parameters.

근적외 분광분석법을 이용한 황색종 잎담배의 화학성분 분석

  • 김용옥;이경구;장기철;김기환
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.20 no.2
    • /
    • pp.183-190
    • /
    • 1998
  • This study was conducted to analyze chemical components in flue-cured tobacco using near infrared spectroscopy(NIRS). Samples were collected in '96 and '97 crop year and were scanned in the wavelengths of 400 ~ 2500 nm by near infrared analyzer(NIRSystem Co., Model 6500). Calibration equations were developed and then analyzed flue-cured samples by NIRS. The standard error of calibration(SEC) and performance (SEP) of '96 crop year samples between NIRS and standard laboratory analysis(SLA) were 0.18% and 0.24% for nicotine, 1.60% and 1.77% for total sugar, 0.13% and 0.15% for total nitrogen, 0.58% and 0.68% for crude ash, 0.23% and 0.28% for ether extracts, and 0.09% and 0.08% for chlorine, respectively. The coefficient of determination($R^2$) of calibration and prediction samples between NIRS and SLA of '96 crop year samples was 0.94~0.99 and 0.83~0.97 depending on chemical components, respectively. The SEC and SEP of '97 crop year samples were similar to those of '96 crop year samples. The SEP of '97 crop year samples which were analyzed using '96 calibration equation was 0.32 % for nicotine, 2.72% for total sugar, 0.14 % for total nitrogen, 1.00 % for crude ash, 0.48 for ether extracts and 0.17% for chlorine, respectively. The prediction result was more accurate when calibration and prediction samples were produced in the same crop year than those of the different crop year. The SEP of '96 and '97 crop year samples using calibration equation which was developed '96 plus '97 crop year samples was similar to that of '96 crop year samples using 96 calibration equation and that of '97 crop year samples using '97 calibration equation, respectively. The SEP of '97 crop year samples using calibration equation which was developed '96 plus '97 crop year samples was lower than that of '97 crop year samples analyzed by '96 calibration equation. To improve the analytical inaccuracy caused by the difference of crop year between calibration and prediction samples, we need to include the prediction sample spectra which are different from calibration sample spectra in recalibration sample spectra, and then develop recalibration equation. Although the analytical result using NIR is not as good as SLA, the chemical component analysis using NIR can apply to tobacco leaves, leaf process or tobacco manufacturing process which demand the rapid analytical result.

  • PDF

Preliminary study on the use of near infrared spectroscopy for determination of plasma deuterium oxide in dairy cattle

  • Purnomoadi, Agung;Nonaka, Itoko;Higuchi, Kouji;Enishi, Osamu;Amari, Masahiro;Terada, Fuminori
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.4101-4101
    • /
    • 2001
  • Information of body composition (fat and protein) in living animal is important to determine the nutrients requirement. Deuterium oxide (D2O) dilution techniques, as one of isotope dilution techniques have been useful for the prediction of body composition. However, the determination of D2O concentration is time consuming and complicated. Therefore this study was conducted to develop a new method to predict D2O concentration in plasma using near infrared spectroscopy technique (NIRS). Four dairy cows in early lactation were used. They were fed total mixed ration containing conr silage, timothy hay, and concentrates to make 17.0%CP and 14.0 MJDE/kgDM. Dosing D2O was at week 1,3 and 5 after parturition. After dosing D2O, the blood was collected from hour 0 to 72. Blood samples were then centrifuge at 3,000 rpm for 10 minutes to obtain plasma. D2O concentration was analyzed by gas chromatograph (deuterium oxide analyzable system, HK102, Shokotsusyou) after extracted from plasma by liophilization. Plasma sample was scanned by NIRS using Pacific Scientific (Neotec) model 6500 (Perstorp Analytical, Silver Spring, MD) in the range of wavelength from 1100 to 2500 nm. Calibration equation was developed using multiple linear regression. Sample from one animal (cow #550; n: 74) was used for developing the calibration while the rest three animals were used for validating the equation. The range, R and SEC of the calibration set samples were 135-925 ppm, 0.93 and 48.1 ppm, respectively. Validation of the calibration equation for three individual cows was done and the average of NIR predicted value of D2O at each collection time from three weeks injection showed a high correlation. The range, r and 53 of plasma from cow #474 were 322-840 ppm,0.93 and 53.1; cow #478 were 146-951 ppm,0.95 and 39.8; cow #942 were 313-885 ppm,0.95 and 37.2, respectively. Judgement of accuracy based on ratio of standard deviation and standard error in validation set samples (RPD) for cow #474, #478 and #942 were 2.2,4.3 and 3.4, respectively. The error in application due to the variation between individual was considered smaller than the bias from collection period, however, this prediction can be overcome with correction of standard zero-minute concentration of blood. The results of this preliminary study on the use of NIRS for determination of D2O in plasma showed very promising as shown by a convenient and satisfy accuracy. Further study on various physiological stage of animal should be done.

  • PDF

DISCRIMINATION BETWEEN VIRGIN OLIVE OILS FROM CRETE AND THE PELOPONESE USING NEAR INFRARED TRANSFLECTANCE SPECTROSCOPY

  • Flynn, Stephen J.;Downey, Gerard
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1520-1520
    • /
    • 2001
  • Food adulteration is a serious consumer fraud and a potentially dangerous practice. Regulatory authorities and food processors require a rapid, non-destructive test to accurately confirm authenticity in a range of food products and raw materials. Olive oil is prime target for adulteration either on the basis of the processing treatments used for its extraction (extra virgin vs virgin vs ordinary oil) or its geographical origin (e.g. Greek vs Italian vs Spanish). As part of an investigation into this problem, some preliminary work focused on the ability of near infrared spectroscopy to discriminate between virgin olive oils from separate regions of the Mediterranean i. e. Crete and the Peloponese. A total of 46 oils were collected: 18 originated in Crete and 28 in the Peloponese. Oils were stored in a temperature-controlled room at 2$0^{\circ}C$ prior to spectral collection at room temperature (15-18$^{\circ}C$). Samples (approximately 0.5$m\ell$) were placed in the centre of the quartz window in a camlock reflectance cell; the gold-plated baking plate was then gently placed into the cell against the glass so as to minimize the formation of air bubbles. The rear of the camlock cell was then screwed into place producing a sample thickness of 0.5mm. Spectra were recorded between 400 and 2498nm at 2nm intervals on a NIR Systems 6500 scanning monochromator. Spectral collection took place over 2-3 days. Data were analysed using both WINISI and The Unscrambler software to investigate the possibility of discriminating between the oils from Crete and the Peloponese. A number of data pre-treatments were used and discriminant models were developed using discriminant PLS (WINISI & Unscrambler) and SIMCA (Unscrambler). Despite the small number of samples involved, a satisfactory discrimination between these two oil types was achieved. Graphical examination of principal component scores for each oil type also holds out the possibility of separating oils from either Crete and the Peloponese on the basis of districts within each region. These preliminary data suggest the potential of near infrared spectroscopy to act as a screening technique for the confirmation of geographic origin of extra virgin olive oils. The sample presentation strategy adopted uses only small volumes of material and produces high quality spectra.

  • PDF

Comparison of Performance of Measuring Method of VIS/NIR Spectroscopic Spectrum to Predict Soluble Solids Content of 'Shingo' Pear (VIS/NIR 스펙트럼 측정모드에 따른 신고 배의 당도 예측성능 비교)

  • Suh, Sang-Ryong;Lee, Kyeong-Hwan;Yu, Seung-Hwa;Yoo, Soo-Nam;Choi, Yeong-Soo
    • Journal of Biosystems Engineering
    • /
    • v.36 no.2
    • /
    • pp.130-139
    • /
    • 2011
  • Three modes of VIS/NIR spectroscopic measurement (interactance and two modes of transmission) were compared for their ability to estimate soluble solids content (SSC) of 'Shingo' pear non-destructively. The two transmission modes are named as full- and semi-transmission, where full-transmission stands for passing of light through abdomen of pear and semi-transmission is for transit of light mainly through flesh of pear. For comparison of the modes, prediction models developed from the collected spectroscopic data by the three modes were developed and tested for comparison of their performance. Partial least square regression (PSLR) was used to develop the models and various pre-processing methods were applied to develop models of high accuracy. The experiment was repeated three times with pears produced in different regions. The experiments resulted that selection of pre-processing is very important to attain accurate models, and multiplicative scatter correction (MSC) was selected as a pre-processor of high accuracy for the three modes of spectroscopic measurement in every experiment. Except for MSC, different group of pre-processing methods were selected for the three modes of measurement in every experiment without any tendency to the tested modes of measurement and pears of different produced region. Root-mean-square error of prediction (RMSEP) of prediction models of the three modes of measurement using prepreocessor of MSC were compared for their ability to estimate SSC. The models resulted in ranges of $0.37{\sim}0.57^{\circ}Brix$, $0.65{\sim}0.72^{\circ}Brix$, $0.39{\sim}0.51^{\circ}Brix$ for interactance, full- and semi-transmission, respectively. As shown, modes of semi-transmission and interactance resulted about the same level of prediction accuracy and were noted as modes of high performance to predict SSC.