• Title/Summary/Keyword: NIPS system

Search Result 14, Processing Time 0.03 seconds

Efficiency Calibration of HPGe Detector in Normal ana Coincidence Mode for the Determination of Prompt Gamma-ray (즉발감마선 측정을 위한 HPGe 검출기의 전계수 또는 동시계수모드에서의 광대역 계측효율 보정)

  • 송병철;박용준;지광용
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.2 no.2
    • /
    • pp.97-104
    • /
    • 2004
  • Neutron induced prompt gamma-ray spectroscopy(NIPS) system measures the prompt gamma-ray emitting by the interaction of a neutron with various materials. This system will be of great benefit to scientists worldwide, since it provides the non-destructive measurement of many element in either solid or liquid wastes. In this study, the full-energy-peak (FEP) efficiency calibration for a HPGe detector was constructed in the ${\gamma}$-ray energy range from 80 keV to 8 MeV, using $^{l33}$Ba and >TEX>$^{152}Eu$ RI sources and $ ^{35}Cl(n, ${\gamma}$)^{36}Cl$ thermal neutron captured reaction. The FEP efficiency curve for the higher energies using the $^{35}Cl(n, ${\gamma}$)^{36}Cl$ reaction was normalized with the curve obtained from the RI sources, since the accurate activity of its prompt ${\gamma}$-ray is unknown. The average thermal neutron flux was theoretically calculated using the FEP efficiency curve for the KCl standard solutions. The NIPS system equipped with a ${\gamma}$-${\gamma}$ coincidence setup with two n-type coaxial HPGe detectors was considered in order to reduce the interfering ${\gamma}$-ray background. The FEP efficiency curve for the ${\gamma}$-${\gamma}$ coincidence system was also obtained for full energy range. The performance of the normal and coincidence NIPS system was tested by comparing signal-to-noise ratio in each mode using the reference sample.e.

  • PDF

Nonpharmacologic Pain Relief with Oral 25% Dextrose or/and Pacifier for Newborn Infants (신생아에서 비약물적 통증조절을 위한 25% 경구 포도당과 인공 젖꼭지 사용의 효과)

  • Kim, Min-Kyung;Kim, In-Ah;Jung, Min-Hee;Han, Myung-Ki;Park, Kie-Young;Kim, Bong-Seong;Jin, Hyun-Seong
    • Neonatal Medicine
    • /
    • v.18 no.2
    • /
    • pp.353-358
    • /
    • 2011
  • Purpose: The goal of this study was to compare the efficacy of oral 25% dextrose treatment or/and pacifier for analgesia in healthy newborns during intramuscular injection of a hepatitis B vaccine. Methods: A prospective, randomized, partially blinded, clinical trial was performed in 132 healthy newborns. They were assigned randomly to 4 treatment groups: control group (2 mL distilled water), dextrose group (2 mL 25% dextrose), pacifier group, dextrose+pacifier group (pacifier coating with 25% dextrose) during intramuscular injection of hepatitis B vaccine. For all groups, Neonatal Infant Pain Scale (NIPS), Neonatal Facial Coding System (NFCS), Premature Infant Pain Profile (PIPP) scores were evaluated before the injection, during the injection, and at 2 minutes after the injection. Pain scores were compared among the 4 groups. Results: Maternal and neonatal characteristics were similar among the 4 groups. 25% dextrose treatment led to lower NIPS pain scores during injection (6.4${\pm}$0.9 vs. 5.5${\pm}$1.7, P=0.01) and after injection (1.6${\pm}$2.0 vs. 0.6${\pm}$0.9, P=0.01) and NFCS pain scores after injection (1.5${\pm}$2.3 vs. 0.7${\pm}$0.8, P=0.04) than control group. The number of neonates who feel the pain (indication of scores: NIPS${\geq}$4, NFCS${\geq}$3) decreased (9 (23.1%) vs. 0 (0%), P=0.04 via NIPS, 7 (17.9%) vs. 0 (0%), P=0.02 via NFCS). However, all treatment groups did not decreased PIPP scores, compared with the control group. Conclusion: Oral 25% dextrose is effective than distilled water or using pacifier with or without 25% dextrose in reducing pain during intramuscular injection of hepatitis B vaccinations. Further study based on this preliminary study need about nonpharmacologic management of pain in newborns.

Development of Neutron Induced Prompt γ-ray Spectroscopy System Using 252Cf (252Cf 선원을 이용한 즉발감마선 계측시스템 구성)

  • Park, Yong-Joon;Song, Byung-Chul;Jee, Kwang-Yong
    • Analytical Science and Technology
    • /
    • v.16 no.1
    • /
    • pp.12-24
    • /
    • 2003
  • For the design and set-up of neutron induced prompt ${\gamma}$-ray spectroscopy system using $^{252}Cf$ neutron source, the effects of shielding and moderator materials have been examined. The $^{252}Cf$ source being used for TLD badge calibration in Korea Atomic Energy Research Institute was utilized for this preliminary experiment. The ${\gamma}$-ray background and prompt ${\gamma}$-ray spectrum of the sample containing Cl were measured using HPGe (GMX 60% relative efficiency) located at the inside of the system connected to notebook PC at the outside of the system (about 20 meter distance). The background activities of neutron and ${\gamma}$-rays were measured with neutron survey meter as well as ${\gamma}$-ray survey meters, respectively and the system was designed to minimize the activities. Prompt ${\gamma}$-ray spectrum was measured using ${\gamma}$-${\gamma}$ coincident system for reduce the background and the continuum spectrum. The optimum system was designed and set up using the experimental data obtained.

Study in Background Reduction for the Neutron Induced Prompt Gamma-ray Spectroscopy

  • Song, Byoung-Chul;Jee, Kwang-Yong;Park, Yong-Joon
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.06a
    • /
    • pp.433-433
    • /
    • 2004
  • Neutron induced prompt gamma-ray spectroscopy (NIPS) system measures the prompt gamma-ray, emitting by the interaction of a neutron with various materials. This system will be of great benefit to scientists worldwide, since it provides the non-destructive measurement of many elements in either solid or liquid wastes. A NIPS facility has been developed in Nuclear Chemistry Research Division, at Korea Atomic Energy Research Institute (KAERI) with the aim of analyzing the major component elements in both aqueous and solid samples.(omitted)

  • PDF

Study on Thermal Neutron Efficiency for Neutron Induced Prompt Gamma-ray Spectrometer Using Various Reflectors (즉발감마선 계측시스템의 반사체를 이용한 열중성자 효율증대 연구)

  • Park, Y.J.;Song, B.C.;Jee, K.Y.
    • Analytical Science and Technology
    • /
    • v.16 no.5
    • /
    • pp.426-429
    • /
    • 2003
  • Neutron induced prompt gamma-ray spectroscopy (NIPS) system equipped with a $^{252}Cf$ neutron source and a n-type coaxial HPGe detector was installed for the quantitative analysis of aqueous samples in KAERI, Korea. Since the thermal neutron flux for the $^{252}Cf$ neutron source is relatively low compared to that for the reactor, the use of a thermal neutron reflector in the NIPS system may lead to improved results. The enhancement by using various reflectors was carried out by comparing the Cl peak with or without a cadmium plate between sample and the $^{252}Cf$ source. The use of pyrolitic graphite as a reflector provided a good result.

A High-speed Pattern Matching Acceleration System for Network Intrusion Prevention Systems (네트워크 침입방지 시스템을 위한 고속 패턴 매칭 가속 시스템)

  • Kim Sunil
    • The KIPS Transactions:PartA
    • /
    • v.12A no.2 s.92
    • /
    • pp.87-94
    • /
    • 2005
  • Pattern matching is one of critical parts of Network Intrusion Prevention Systems (NIPS) and computationally intensive. To handle a large number of attack signature fattens increasing everyday, a network intrusion prevention system requires a multi pattern matching method that can meet the line speed of packet transfer. In this paper, we analyze Snort, a widely used open source network intrusion prevention/detection system, and its pattern matching characteristics. A multi pattern matching method for NIPS should efficiently handle a large number of patterns with a wide range of pattern lengths and case insensitive patterns matches. It should also be able to process multiple input characters in parallel. We propose a multi pattern matching hardware accelerator based on Shift-OR pattern matching algorithm. We evaluate the performance of the pattern matching accelerator under various assumptions. The performance evaluation shows that the pattern matching accelerator can be more than 80 times faster than the fastest software multi-pattern matching method used in Snort.

An Improved Signature Hashing-based Pattern Matching for High Performance IPS (고성능 침입방지 시스템을 위해 개선한 시그니처 해싱 기반 패턴 매칭 기법)

  • Lee, Young-Sil;Kim, Nack-Hyun;Lee, Hoon-Jae
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.10a
    • /
    • pp.434-437
    • /
    • 2010
  • NIPS(Network Intrusion Prevention System) is in line at the end of the external and internal networks which performed two kinds of action: Signature-based filtering and anomaly detection and prevention-based on self-learning. Among them, a signature-based filtering is well known to defend against attacks. By using signature-based filtering, intrusion prevention system passing a payload of packets is compared with attack patterns which are signature. If match, the packet is discard. However, when there is packet delay, it will increase the required pattern matching time as the number of signature is increasing whenever there is delay occur. Therefore, to ensure the performance of IPS, we needed more efficient pattern matching algorithm for high-performance ISP. To improve the performance of pattern matching the most important part is to reduce the number of comparisons signature rules and the packet whenever the packets arrive. In this paper, we propose an improve signature hashing-based pattern matching method. We use tuple pruning algorithm with Bloom filters, which effectively remove unnecessary tuples. Unlike other existing signature hashing-based IPS, our proposed method to improve the performance of IPS.

  • PDF

Load Balancing Algorithm for Parallel Computing of Design Problem involving Multi-Disciplinary Analysis (다분야통합해석에 기반한 설계문제의 병렬처리를 위한 부하분산알고리즘)

  • Cho, Jae-Suk;Chu, Min-Sik;Song, Yong-Ho;Choi, Dong-Hoon
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2007.04a
    • /
    • pp.327-332
    • /
    • 2007
  • An engineering design problem involving Multi-Disciplinary Analysis(MDA) generally requires a large amounts of CPU time for the entire design process, and therefore Multiple Processing System (MPS) are essential to reduce the completion time. However, when applying conventional parallel processing techniques, all of the CAE S/W required for the MDA should be installed on all the servers making up NIPS because of characteristic of MDA and it would be a great expense in CAE S/W licenses. To solve this problem, we propose a Weight-based Multiqueue Load Balancing algorithm for a heterogeneous MPS where performance of servers and CAE S/W installed on each server are different of each other. To validate the performance, a computational experiments comparing the First Come First Serve algorithm and our proposed algorithm was accomplished.

  • PDF

A High-speed Packet Filtering System Architecture in Signature-based Network Intrusion Prevention (시그내쳐 기반의 네트워크 침입 방지에서 고속의 패킷 필터링을 위한 시스템 구조)

  • Kim, Dae-Young;Kim, Sun-Il;Lee, Jun-Yong
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.34 no.2
    • /
    • pp.73-83
    • /
    • 2007
  • In network intrusion prevention, attack packets are detected and filtered out based on their attack signatures. Pattern matching is extensively used to find attack signatures and the most time-consuming execution part of Network Intrusion Prevention Systems(NIPS). Pattern matching is usually accelerated by hardware and should be performed at wire speed in NIPS. However, that alone is not good enough. First, pattern matching hardware should be able to generate sufficient pattern match information including the pattern index number and the location of the match found at wire speed. Second, it should support pattern grouping to reduce unnecessary pattern matches. Third, it should always have a constant worst-case performance even if the number of patterns is increased. Finally it should be able to update patterns in a few minutes or seconds without stopping its operations, We propose a system architecture to meet the above requirement. The system architecture can process multiple pattern characters in parallel and employs a pipeline architecture to achieve high speed. Using Xilinx FPGA simulation, we show that the new system stales well to achieve a high speed oner 10Gbps and satisfies all of the above requirements.