A Study on Patients Dose and Image Quality according to Source to Image receptor Distance in Abdomen Radiography: comparison of ESD measured and DRLs in other countries (복부일반촬영시 선원과 검출기간의 거리변화에 따른 영상 화질 및 피폭선량에 관한 연구)

  • Jang, Ji-Sung;Choi, Weon-Keun;Jung, Jae-Yon;Lee, Kwan-Sub;Ha, Dong-Yoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.39-46
    • /
    • 2012
  • Purpose : The purpose of this study was to reduce Entrance Surface Dose and maintain image quality by changing Source to Image receptor Distance. And we'd like to compare ESD on this study to DRLs in other contries. Materials and Methods : We used indirect DR system(Definium 8000, General Electric, USA)and phantom(ART-200X, Flukebiomedical, USA),glass dosimeters(GD-352M, Asahi Techno Glass, Japan)for this study. The imagies were obtained throuh 80kVp fixed, and different tube currents using AEC mode in $16{\times}16$(inch) field size and changing Source to Image receptor Distance from 100 cm to 130 cm per 10 cm unit. The phantom with attaching 5 glass dosimeters on abdomonal skin was set at supine and erect position as a anterioposterial projection on detector For measuring Entrance Surface Dose. Image analysis was conducted by histograms of Image J(1.46r) which was given from National Institutes of Health(NIH). Results : Due to inverse square law of distance, the tube currents were increasing 42.6 % in supine position and 32.6 % in erect position according to the change of Source to Image receptor Distance. While Entrance Surface Doses were rapidly decreasing 14.2 % in supine position and 29.4 % in erect position according to the change of Source to Image receptor Distance. As the results of histogram using Image J, pixel mean values from 100 cm to 110 cm, 120 cm and 130 cm were decreasing each 1.4%, 2.5%, 2.7%, 4.5%, 2.2 %, 5.8 % in supine, erect position. While standard deviations from 100 cm to 110 cm, 120 cm and 130 cm were increasing each 1.4 %, 2.5 %, 2.5 %, 4.0 %, 2.0 %, 4.9 % Consequently, there are no significant differences in abdomen images taken. Conclusion: As the results described above, we strongly recommend using long Sourceto Image receptor Distance than 100cm that we have been using. So, we should deliver less Entrance Surface Dose to the patients while maintaining image quality in abdomen radiography.

  • PDF

A Study of Image Characteristics due to Focus-Grid and Head Phantom Decentering from the Armorphos Silicon Thin Film Transistor Detector the Fixed Focus-Grid is Applied (고정식 초점형 격자가 적용된 비정절 실리콘 평판형 검출기에서 초점-격자와 두부 팬텀의 중심 변위에 의한 화질 특성에 관한 연구)

  • Choi, Jun-Gu;Kim, Byeong-Gi;Cha, Seon-Hwa;Kim, Gyeong-Su
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.9 no.1
    • /
    • pp.7-15
    • /
    • 2007
  • This study aim to investigate image characteristics due to focus-grid and head phantom decentering from the armorphos silicon thin film transistor detector the fixed focus-grid is applied, wish to propose right use method of digital medical equipment. Acquired image according to focus-grid and head phantom position decentering using head phantom on armorphos silicon thin film transistor detector the fixed focus-grid is applied. acquired image evaluate pixel value, histogram, plot profile, surface plot using NIB (Image J) image analysis program and compared decentering image with standard image. Mean value and standard deviation value of focus-grid lateral decentering and duplex decentering of focus-grid and head phantom decreased by ratio, consequently increase of horizontality, diagonal decentering. also, deteriorated contrast of image because frequency of high pixel value decreases fairly. according increases decentering, image distortion phenomenon was increase, by next time, pixel mean value of head phantom decentering was no big change but horizontality, diagonal, mean value and standard deviation value of pixel decreased by ratio. Even if increase pixel noise of image because wide latitude and post processing ability of digital detector, radiotechnologist can not recognize. Therefore, radiotechnologist must recognize correctly the photographing factors which increases pixel noise on the grid system installation digital detector and should exam.

  • PDF

Influence of the Lumbar Spine Adjustment using the Lumbar Roll Support on Head and Neck Posture in Older Adults (요추 지지대에 의한 노인의 요추만곡 조절이 머리와 목 자세에 미치는 영향)

  • Ko, Seung-Hyun;Kim, Yu-Shin;Yoon, Bum-Chul
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.12
    • /
    • pp.800-806
    • /
    • 2011
  • The objective of this study was to identify the effect of lumbar lordotic curve adjustment on head and neck posture in older adults. Methods Twenty healthy older participants (mean age 71.32) were photographed while watching monitor in sitting with or without lumbar roll support(length 28cm, diameter 10cm). The upper cervical angle and lower cervical angle were measured using the NIH ImageJ 1.32. Comparisons between upper and lower cervical angle with or without lumbar roll support were made using paired-t test analysis. Results Subjects demonstrated a significant difference in the mean upper and lower cervical angle. Mean difference of the upper cervical angle was about $2.83^{\circ}$ with and without lumbar roll support(p<0.005). Mean difference of the lower cervical angle was about $4.44^{\circ}$ with and without lumbar roll support(p<0.0001). Conclusions This study showed that healthy older adults demonstrated more ability to maintain an upright posture of cervical spine during lumbar lordotic curve maintenance with lumbar roll support than without lumbar roll support. When the clinicians consider improvement of the head and neck posture in older adults, they must incorporate adjustment in the lumbar region.

The Role of nerve Growth Factor on Corneal Wound Healing in Dogs

  • 우흥명
    • Journal of Veterinary Clinics
    • /
    • v.18 no.4
    • /
    • pp.418-423
    • /
    • 2001
  • To investigate the modulation of nerve growth factor (NGF) during corneal epithelial wound healing and the effect of topical NGF on corneal epithelial wound healing in dogs. An axial epithelial defect was created in the right eye using 6mm axial corneal mechanical debridement while the left served as an unwounded control. The tears were collected from both eyes during 1 week and the corneal epithelium was processed for the measurement of NGF at day 0 and 7. The NGF content of tears and corneal epithelium was determined by enzyme-linked immunosorbent assay. In another experiment, the animals were divided into 3 groups. The right eyes in each group were treated every six hours with 200 ug/ml of recombinant human (rh) NGF, murine NGF, or 600 ug/ml of anti-NGF blocking antibody. The left eye of each animal was treated with bovine serum albumin (BSA) to serve as controls. Wound healing was analyzed using NIH image software. Tear NGF was markedly increased in the wounded eyes, relative to tears from control eyes during the early healing period. The NGF content of the corneal epithelium was elevated in the wounded eye (p=0.024). Time to wound closure and rate of epithelial migration were not significantly different between the NGF treated or the NGF antibody treated, and the control BSA treated eyes. Corneal epithelial wounding increased NGF content only on the wounded side during the early healing period. Neither topical recombinant human or murine NGF affected corneal epithelial wound healing in the normal dog.

  • PDF

Study on Performance Evaluation of Dental X-ray Equipment (치과 방사선 발생기의 성능평가에 관한 연구)

  • Jung, Jae-Eun;Jung, Jae-Ho;Kang, Hee-Doo;Lee, Jong-Woong;Ra, Keuk-Hwan
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.11 no.2
    • /
    • pp.115-119
    • /
    • 2009
  • I think this will be valuable reference for assuring consistency and homogeneity of clarity and managing dental radiation equipment by experimentation of dental radiation equipment permanent which based on KS C IEC 61223-3-4 standard and KS C IEC 61223-2-7. Put a dental radiation generator and experiment equipment as source and film(sensor) length within 30 em, place the step-wedge above the film(sensor). Tie up tube voltage 60 kVp, tube current 7 mA and then get an each image through CCD sensor and film by changing the exposure time as 0.12sec, 0.25sec, 0.4sec. Repeat the test 5times as a same method. Measure the concentration of each stage of film image, which gained by experiment, using photometer. And the image that gained by CCD sensor, analyze the pixel value's change by using image J, which is analyzing image program provided by NIH(National Institutes of Health). In case of film, while 0.12sec and 0.25sec show regular rising pattern of density gap as exposure time's increase, 0.4sec shows low rather than 0.12sec and 0.25sec. In case of CCD sensor density test, the result shows opposite pattern of film. This makes me think that pixels of CCD's sensor can have 0~255 value but it becomes saturation if the value is over 255. The way that getting clear reception during decreasing human's exposed radiation is one of maintaining an equipment as a best condition. So we should keeping a dental radiation equipment's condition steadily through cyclic permanent test after factor examination. Even digital equipment doesn't maintain a permanent, it can maintain a clarity by post processing of image so that hard to set it as standard of permanent test. Therefore it would be more increase the accuracy that compare a film as standard image. Thus I consider it will be an important measurement to care for dental radiation equipment and warrant homogeneity, consistency of dental image's clarity through comparing pattern which is the result from factor test against cyclic permanent test.

  • PDF

Analysis of Contrast Medium Dilution Rate for changes in Tube Current and SOD, which are Parameters of Lower Limb Angiography Examination (하지 혈관조영검사 시 매개변수인 관전류와 SOD에 변화에 대한 조영제 희석률 분석)

  • Kong, Chang gi;Han, Jae Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.603-612
    • /
    • 2020
  • This study has a purpose to look into the effect of the relationship between the Tube current (mA) and SOD(Source to Object Distance), which is a parameter of lower limb angiography examination, and the dilution rate of the contrast medium concentration (300, 320, 350) on the image. To that end, using 3 mm vessel model water phantom, a vessel model custom made in the size of peripheral vessel diameter, this study measured relationships between change of parameters, such as tube current (mA), SOD and varying concentrations (300, 320, 350) of contrast medium dilution into SNR and CNR values while analyzing the coefficients of variance(cv<10). The software used to measure SNR and CNR values was Image J 1.50i from NIH (National Institutes of Health, USA). MPV (mean pixel value) and SD (standard deviation) were used after verifying numerically the image signal for region of interest (ROI) and background on phantom from the DICOM (digital imaging and communications in medicine) 3.0 file transmitted to PACS. As to contrast medium dilution by the change of tube current, when 146 mA and 102 mA were compared, For both SNR and CNR, the coefficient of variation value was less than 10 until the section of CM: N/S dilution (100% ~ 30% : 70%) but CM: N/S dilution rate (20%: 80% ~ 10% : 90%) the coefficient of variation was 10 or more. As to contrast medium dilution by concentration for SOD change, when SOD's (32.5 cm and 22.5 cm) were compared,For both SNR and CNR, the coefficient of variation value was less than 10 until the section of CM: N/S dilution (100% ~ 30% : 70%) but CM: N/S dilution rate (20%: 80% ~ 10% : 90%) the coefficient of variation was 10 or more. As to contrast medium dilution by concentration for SOD change, when SOD's (32.5 cm and 12.5 cm) were compared,For both SNR and CNR, the coefficient of variation value was less than 10 until the section of CM: N/S dilution (100% ~ 30% : 70%) but CM: N/S dilution rate (20%: 80% ~ 10% : 90%) the coefficient of variation was 10 or more. As a result, set a low tube current value in other tests or procedures including peripheral angiography of the lower extremities in the intervention, and make the table as close as possible to the image receiver, and adjust the contrast agent concentration (300) to CM: N/S dilution (30%: 70%). ) Is suggested as the most efficient way to obtain images with an appropriate concentration while simultaneously reducing the burden on the kidney and the burden on exposure.

Evaluation of Bone Change by Digital Subtraction Radiography after Implantation of Tooth Ash-plaster Mixture (치아회분과 석고혼합제제 매식후 Digital Subtraction Radiography에 의한 골량 변화의 평가)

  • Kim Jae-Duk;Kim Kwang-Won;Cho Yaung-Gon;Kim Dong-Kie;Choi Eui-Hwan
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.2
    • /
    • pp.423-433
    • /
    • 1999
  • Purpose : To assess the methods for the clinical evaluation of the longitudinal bone changes after implantation of tooth ash-plaster mixture into the defect area of human jaws. Materials and methods : Tooth ash-plaster mixtures were implanted into the defects of 8 human jaws. 48 intraoral radiograms taken with copper step wedge as reference at soon, 1st, 2nd, 4th, and 6th week after implantation of mixture were used. X-ray taking was standardized by using Rinn XCP device customized directly to the individual dentition with resin bite block. The images inputted by Quick scanner were digitized and analyzed by NIH image program. Cu­equivalent values were measured at the implanted sites from the periodic digital images. Analysis was performed by the bidirectional subtraction with color enhancement and the surface plot of resliced contiguous image. The obtained results by the two methods were compared with Cu­equivalent value changes. Results : The average determination coefficient of Cu-equivalent equations was 0.9988 and the coefficient of variation of measured Cu values ranged from 0.08~0.10. The coefficient of variation of Cu-equivalent values measured at the areas of the mixture and the bone by the conversion equation ranged from 0.06 ~0.09. The analyzed results by the bidirectional subtraction with color enhancement were coincident with the changes of Cu-equivalent values. The surface plot of the resliced contiguous image showed the three dimensional view of the longitudinal bone changes on one image and also coincident with Cu-equivalent value changes after implantation. Conclusion : The bidirectional subtraction with color enhancement and the surface plot of the resliced contiguous image was very effective and reasonable to analyze clinically and qualitatively the longitudinal bone change. These methods are expected to be applicable to the non-destructive test in other fields.

  • PDF

Study on the Correlation Between Physical Function and Forward Head Posture in Spastic Diplegia (경직형 양하지 뇌성마비 아동의 전방머리자세와 신체기능간의 상관관계)

  • Jo, Yong-Eun;Lee, Eun-Ju
    • PNF and Movement
    • /
    • v.19 no.2
    • /
    • pp.163-172
    • /
    • 2021
  • Purpose: This study investigated the correlation between physical function and forward head posture in spastic diplegia. Methods: The subjects of this study were 10 spastic diplegia patients. We took pictures of the subjects' craniovertebral angle with a digital camera to determine the degree of forward head posture and then analyzed them using the NIH image J program. The physical function test used the TCMS, the BBT, and a spirometer. The data in this study were measured using SPSS version 23.0, and the statistical significance level α was 0.05. A Pearson correlation coefficient analysis was performed to identify the correlation between the degree of the subject's head forward position and physical function. Results: When we performed the BBT and spirometer tests, the subjects' forward head postures were not correlated (p < 0.05). However, with the TCMS, there was a strong correlation between the forward position of the head and balance, with balance decreasing as the head position increased (p < 0.05). Conclusion: Spastic diplegia patients with severe forward head posture showed problems with static balance, dynamic balance, and equilibrium reaction when sitting. Intervention on the right posture and preventive activities will be needed to improve the health of spastic diplegia patients and prevent future problems with physical function.

Repair of UV-induced Cyclobutane Pyrimidine Dimers in Human Mitochonrial DNA-less Cells

  • Ikushima, Takaji;Gu, Ning;Tanizaki, Yuichi
    • Journal of Photoscience
    • /
    • v.9 no.2
    • /
    • pp.479-481
    • /
    • 2002
  • UV-induced DNA damage causes cell killing and mutations leading to carcinogenesis. In normal human cells, UV damage such as cyclobutane pyrimidine dimers (CPDs) and primidine-prymidone (6-4) photoproducts are mainly repaired by nucleotide excision repair mechanism. The molecular processes have been well characterized recently. To know the influence of mitochondrial genome on the nucleotide excision repair mechanism against CPDs, we comparatively examined the production of CPDs by UVC irradiation and their repair kinetics in human cells completely lacking mitochondrial DNA (mtDNA) and the parental HeLa S cells. Whole DNA extracted from the cells exposed to UVC was treated with T4-endonuclease V to break the phosphodiester bond adjacent to CPDs. The DNA was electrophoresed in a denaturing agarose gel, which was visualized by ethidium bromide staining. The relative amount of CPDs was determined by image analysis using NIH Image software. MtDNA- less (rho-O) cells were apparently more sensitive to UVC than HeLa S cells, while the level of induction of CPDs in rho-O and HeLa cells was comparable. The repair of CPDs was less efficient in rho-O cells compared with HeLa cells. The residual amount of CPDs after 24-h repair was larger in rho-O cells than in HeLa cells where more than 90 % of CPDs were repaired by then. The non-repaired CPDs would lead to apoptosis in rho-O cells. These results suggest that mitochondrial genome may contribute to some ATP-dependent steps in nucletide excision repair by supplying sufficient ATP which is generated through a respiratory chain in mitochondria.

  • PDF

An Assessment on Cu-Equivalent Image of Digital Intraoral Radiography (디지털구내방사선사진의 구리당량화상에 대한 평가)

  • KIM JAE-DUK
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.1
    • /
    • pp.33-42
    • /
    • 1999
  • Geometrically standardized dental radiographs were taken. We prepared Digital Cu-Equivalent Image Analyzing System for quantitative assessment of mandible bone. Images of radiographs were digitized by means of Quick scanner and personal Mcquintosh computer. NIH image as software was used for analyzing images. A stepwedge composed of 10 steps of 0.1mm copper foil in thickness was used for reference material. This study evaluated the effects of step numbers of copper wedge adopted for calculating equation. kVp and exposure time on the coefficient of determination(r²)of the equation for conversion to Cu-equivalent image and the coefficient of variation and Cu-Eq value(mm) measured at each copper step and alveolar bone of the mandible. The results were as follows: 1. The coefficients of determination(r²) of 10 conversion equations ranged from 0.9996 to 0.9973(mean=0.9988) under 70kVp and 0.16 sec. exposure. The equation showed the highest r was Y=4.75614612-0.06300524x +0.00032367x² -0.00000060x³. 2. The value of r² became lower when the equation was calculated from the copper stepwedge including 1.0mm step. In case of including 0mm step for calculation. the value of r showed variability. 3. The coefficient of variation showed 0.11, 0.20 respectively at each copper step of 0.2, 0.1mm in thickness. Those of the other steps to 0.9 mm ranged from 0.06 to 0.09 in mean value. 4. The mean Cu-Eq value of alveolar bone was 0.14±0.02mm under optimal exposure. The values were lower than the mean under the exposures over 0.20sec. in 60kVp and over 0.16sec. in 70kVp. 5. Under the exposure condition of 60kVp 0.16sec.. the coefficient of variation showed 0.03. 0.05 respectively at each copper-step of 0.3, 0.2mm in thickness. The value of r² showed over 0.9991 from both 9 and 10 steps of copper. The Cu-Eq value and the coefficient of variation was 0.14±0.01mm and 0.07 at alveolar bone respectively. In summary. A clinical application of this system seemed to be useful for assessment of quantitative assessment of alveolar provided high coefficient of determination is obtained by the modified adoption of copper step numbers and the low coefficient of variation for the range of Cu-Equivalent value of alveolar bone from optimal kVp and exposure time for each x-ray machine.

  • PDF