• Title/Summary/Keyword: NI-01

Search Result 248, Processing Time 0.036 seconds

Preparation and analysis of nickel-coated alumina by sonochemistry (음향화학법으로 니켈을 코팅한 알루미나의 제조 및 분석)

  • Kim, Jin-Woo;Choi, Sung-Woo;Lee, Chang-Seop
    • Analytical Science and Technology
    • /
    • v.24 no.2
    • /
    • pp.61-68
    • /
    • 2011
  • Ni-coated alumina was prepared by sonochemical method. To increase an efficiency of Ni coating on alumina, amorphous alumina was prepared by sol-gel method and Ni was coated to fine particles of alumina. Ni-coated alumina was prepared from various calcination temperatures ($500^{\circ}C$, $1,000^{\circ}C$), concentrations of Ni solution (0.01 M~0.2 M) and sonochemical reaction times (30 min, 2h). The prepared fine particles were characterized by X-Ray Diffractometer (XRD), Scanning Electron Microscope (SEM), Inductively Coupled Plasma Atomic Emission Spectroscopy (ICP-AES), and Particle Size Analyzer (PSA). The coating amount of Ni increased, as Ni concentration and ultrasonication time increased. The maximum amount of Ni was coated to fine particles of alumina, when Ni-coated alumina was prepared with 0.1 M concentration of Ni solution for 2 h of sonication time at $1000^{\circ}C$ of calcination temperature. The average particle size was in the range of 835.9 to 986.7 nm.

A Study on the Heavy Metal Content of Permanent Wave Products (퍼머넌트 웨이브제의 중금속 함량에 관한 연구)

  • Yoo, Tai-Soon;Jang, Nam-Soon;Jung, Yeon
    • Journal of the Korean Society of Fashion and Beauty
    • /
    • v.2 no.2 s.2
    • /
    • pp.93-100
    • /
    • 2004
  • This study is to measure the heavy metal content of permanent wave products which on marketing correctly as estimating the extent of exposure by a hair permanent wave scientifically. We would like to prevent an affair from arising health obstruction as to the heavy metal who is using those and also show the basic data for proposing the new standard. The results were as follows.: in case of the average heavy metal content for a wave type thioglycol acid ingredient includes 1.61ppm(Pb), 0.03ppm(Cd), 0.05ppm(Ni), 0.27ppm(Mn), 0.82ppm(Cu) and those were recognized the significant gap between products all the heavy metals. In case of a cysteine acid ingredient includes 0.86ppm(Pb), 0.01ppm(Cd), 0.05ppm(Ni), 0.20ppm(Mn) and 0.66ppm(Cu) and those were recognized the significant gap between products except a nickel. Straight type of permanent wave reductant includes 2.11ppm(Pb), 0.01ppm(Cd), 0.27ppm(Ni), 0.66ppm(Mn), 2.53ppm(Cu) and those were recognized the significant gap between products all the heavy metals. Permanent wave reducing agent includes 1.43ppm(Pb), 0.01ppm(Cd), 0.09ppm(Ni), 0.66ppm(Mn), 0.75ppm(Cu) and those were approved the significant gap between products except a cadmium. Exposure level of the heavy metal contents per onetime permanent waving were 242.3ppm(Pb), 2.5ppm(Cd), 17.7ppm(Ni), 89.0ppm(Mn), 174.7ppm(Cu).

  • PDF

A Study on the Deformation Behaviors of $Ni_3Al$ Single Crystals Depending on Crystallographic Orientations (결정학적 방위에 의존하는 $Ni_3Al$ 단결정의 변형거동에 관한 연구)

  • Han, Chang-Suk;Chun, Chang-Hwan;Han, Seung-Oh
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.22 no.3
    • /
    • pp.155-161
    • /
    • 2009
  • An investigation of the deformation behavior of ${\gamma}'-Ni_3Al$ single crystals containing fine dispersion of disordered ${\gamma}$ particles was performed for several different crystal orientations. Deformation structures were observed by the weak-beam method of transmission electron microscopy (TEM). The critical resolved shear stress (CRSS) for (111) [$\bar{1}$01] slie. increases with increasing temperature in the temperature range where (111) slip operates. The CRSS for (111) [$\bar{1}$01] slip is dependent on crystal orientation in the corresponding temperature range. The temperature where the strenjlth reaches a maximum is dependent on crystal orientation; the higher the ratio of the Schmid factors of (010) [$\bar{1}$01] to that of (111) [$\bar{1}$01], the higher the peak temperature. The peak temperatures were increased by the precipitation of y particles for the samples of all orientations. Electron microscopy of deformation induced dislocation arrangements under peak temperature has revealed that most of dislocations are straight screw dislocations. The mobility of screw dislocations decreases with increasing temperature. Above the peak temperature, dislocations begin to cross slip from the (111) [$\bar{1}$01] slip system to the (010) [$\bar{1}$01] slip system, thus decreasing the strength.

Pore Structure and Mechanic:11 Property of Porous TiNi Biomaterial Produced by Self-Propagating High-Temperature Synthesis (고온자전합성법으로 제조된 다공성 TiNi 생체재료의 기공구조 및 기계적 특성)

  • 김지순;강지훈;양석균;정순호;권영순
    • Journal of Powder Materials
    • /
    • v.10 no.1
    • /
    • pp.34-39
    • /
    • 2003
  • Porous TiNi bodies were produced by Self-propagating High-temperature Synthesis (SHS) method from a powder mixture of Ti and Ni. Porosity, pore size and structure, mechanical property, and transformation temperature of TiNi product were investigated. The average porosity and pore size of produced porous TiNi body are 63% and $216\mutextrm{m}$, respectively. XRD analysis showed that the major phase of produced TiNi body is B2 phase. Its average fracture strength and elastic modulus measured under dry condition were $22\pm2$ MPa and $0.18\pm0.01$GPa, respectively. It could be strained up to 7.3 %. The transformation temperatures determined by DSC showed the $M_s$ temperature of $67^{\circ}C$ and $A_f$ temperature of $99^{\circ}C$.

Study on Heavy Metal Contents in Air of Den Tal Laboratories and Urine of Dental Laboratory Technicians in CHONBUK Area (전북지방 치과기공실 공기중 및 치과기공사의 뇨중중금속 함량에 관한 연구)

  • 이정오;이종섭;유인수
    • Journal of Environmental Health Sciences
    • /
    • v.16 no.2
    • /
    • pp.97-103
    • /
    • 1990
  • For this study, I used the urine of 100 dental laboratroy technicians and 24 students in Chonbuk region. The purposes of this study were to investigate concentrations of cadmium (Cd), nickel (Ni) and chromium (Cr) in the air of dental laboratories. The results were as follows: 1. The concentrations of Cd is 0.0115mg/m$^{3}$ in the porcelain part, 0.0090mg/m$^{3}$ in the polishing part, that of Ni is 0.2864mg/m$^{3}$ in the porcelain part, 0.3188mg/m$^{3}$ in the polishing part, that of Cr is 0.0448mg/m$^{3}$ in the porcelain part, 0.1032mg/m$^{3}$ in the polishing part. 2. The concentrations of Cd, Ni and Cr in the technicians urine are 3.06 $\mu$g/l, 44.55 $\mu$g/l and 14.58 $\mu$g/l. Those of students, urine as the control group are 1.93 $\mu$g/l, 19.05 $\mu$g/l and 7.48 $\mu$g/l. There is significant difference between experimental group and control group (P < 0.01). 3. Watching for age and working place, 31-40 years age group reveals the highest group in the concentrations of Cd. Over 41 year age group represents the highest group in the concentrations of Ni and Cr (P < 0.01) The concentration of Cd turns up the highest in the partial part and that of Ni and Cr appears the highest in the polishing part (P < 0.01). Looking into working age, over 7 year group is the highest group in the concentrations of all investigated (P < 0.05).

  • PDF

Preparation of Electrode Using Ni-PTFE Composite Plating for Alkaline Fuel Cell (Ni-PTFE 복합도금기술을 이용한 알칼리형 연료전지용 전극 제조)

  • Kim, Jae-Ho;Lee, Young-Seak
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.20 no.5
    • /
    • pp.361-370
    • /
    • 2009
  • Ni-PTFE composite plated on graphite (C/Ni-PTFE) and PTFE (PTFE/Ni-PTFE) particles were prepared uniformly by electroless composite plating. The conductivity of C/Ni-PTFE particles was 280 S/m higher than 95 S/m of PTFE/Ni-PTFE particles at same composite plating condition (Ni:35~36 wt%, PTFE:8 wt%). The C/Ni-PTFE particles were formed into the C/Ni-PTFE plate using heat treatment at $350^{\circ}C$ under 10~$1000\;kg/cm^2$. The C/Ni-PTFE plate showed 1) high conductivity of $5.7\;{\times}\;10^4\;S/m$ due to the existence of graphite as conducting aid and the formation of 3-dimensional Ni network 2) good gas diffusion caused by various pore volumes (0.01~$100\;{\mu}m$) in the plate. The plate could be useful for an electrode in an alkaline fuel cell (AFC). The current density of C/Ni-PTFE electrode indicated $84\;mA/cm^2$ at 0.3V and it was 3.0 times higher than that of PTFE/Ni-PTFE electrode.

Quantitative Structure Determination of Ni(111)(2×2)-O/CO: temperature Dependent Study (광전자회절을 이용한 Ni(111)(2×2)-O/CO의 표면 흡착 구조: 시편준비의 온도 의존성)

  • Kang J.H.
    • Journal of the Korean Magnetics Society
    • /
    • v.16 no.1
    • /
    • pp.92-97
    • /
    • 2006
  • A study of the adsorption site of CO in the Ni(111)$(2\times2)$-O/CO coadsorbed phase over different sample preparation temperatures revealed that the atop site is favoured. The Ni-C spacing is given by $1.77\pm0.01\;{\AA}$. A study of the adsorption site of Co in the Ni(111)$(2\times2)$-O/CO coadsorbed phase over different sample preparation temperatures revealed that the atop site is favoured. The Ni-C spacing is given by $1.77\pm0.01\;{\AA}$. The data from the sample prepared at 265 K showed atop sites, which is well consistent with vibrational spectroscopy, whilst the data from the low temperature preparation appears the mixture of atop and hop $(35\%)$. The occupation of hop hollow sites is probably due to an incorrect pre-coverage of atomic oxygen (different from 0.25ml). Similar observation of site mixture also found in recent high resolution XPS measurements using C 1s and O 1s chemical shifts.

Magnetic and Electric Properties of Multiferroic Ni-doped BiFeO3

  • Yu, Yeong-Jun;Hwang, Ji-Seop;Park, Jeong-Su;Lee, Ju-Yeol;Gang, Ji-Hun;Kim, Gi-Won;Lee, Gwang-Hun;Lee, Bo-Hwa;Lee, Yeong-Baek
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.182-182
    • /
    • 2014
  • Multiferroic materials have attracted much attention due to their own fascinating fundamental physical properties and potential technological applications to magnetic/ferroelectric data storage systems, quantum electromagnets, spintronics, and sensor devices. Among single-phase multiferroic materials, $BiFeO_3$, in particular, has received considerable attention because the enhanced ferromagnetism was found by the Fe-site ion substitution with magnetic ions. The structural, the magnetic and the ferroelectric properties of polycrystalline $BiFe_{1-x}Ni_xO_3$ (x=0, 0.01, 0.02, 0.03 and 0.05), which were prepared by the solid-state reaction and the rapid-sintering method, have been investigated. The x-ray diffraction patterns reveal that all the samples are in single phase and show rhombohedral structure with R3c space group. The magnetic properties are enhanced according to the doping content. The Ni-doped $BiFeO_3$ samples exhibit lossy P-E loop due to the oxygen vacancy. The leakage current density of Ni-doped samples (x=0.01 and 0.02) is increased by four orders of magnitude. On the other hand, the x=0.03 and 0.05 samples show the relative reduction of the leakage current.

  • PDF