• Title/Summary/Keyword: NGV2 인증

Search Result 2, Processing Time 0.017 seconds

Development of the High Pressure Hydrogen Gas Cylinder(Type4) for Fuel Cell Vehicle;Design Qualification Tests (연료전지 차량용 고압기체수소 저장용기(Type4)개발;설계검증시험)

  • Yoo, Gye-Hyoung;Ju, Yong-Sun;Heo, Seok-Bong;Jeon, Sang-Jin;Kim, Jong-Lyul;Lee, Jong-Hee
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.193-196
    • /
    • 2007
  • We developed and tested the high pressure hydrogen gas cylinder(type4) for fuel cell vehicle. The working pressure is 350bar. We conducted material tests, production tests and design qualification tests on the developed cylinders according to modified NGV2-2000(hydrogen). The high pressure hydrogen gas cylinder met all the design qualification requirements of ANSI/CSA NGV2-2000 and acquired NGV2 certification from independent inspection agency.

  • PDF

A Study on Performance of Pressure Relief Devices of CNG Cylinder Valves (CNG 용기용밸브의 압력방출장치 성능에 관한 연구)

  • Kim, Young-Seob;Kim, Lae-Hyun;Lee, Jae-Hun
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.4
    • /
    • pp.33-39
    • /
    • 2009
  • This study is intended to experiment performance of pressure relief device and to extend the effective ways to prevent cylinders of NGV from bursting when they are exposed to local fire intensively or when they are overcharged under ambient temperature at fueling stations in summer. In the results of thermal cycling experiments, all products of three companies met the requirements for gas leakage in the qualification criteria between $82^{\circ}C$ and $-40^{\circ}C$. But the o-rings of two companies' specimens among the three companies' specimens got damaged under the accelerated conditions between $135^{\circ}C$ and $-45^{\circ}C$. It took one minute and thirty nine seconds for a glass bulb type of a thermal sensitive type PRD to activate and it took two minutes and thirty one seconds for a fusible plug type of a thermal sensitive type PRD to activate. These results indicated that a glass bulb type of a thermal sensitive type PRD was one minute faster than a fusible plug type of a thermal sensitive type PRD. Under the accelerated condition $135^{\circ}C$, the activation pressure of a pressure sensitive type PRD burst at 32.1 MPa and, under the condition of qualification criteria, it burst from 30.7 MPa to 32.1 MPa.. As a result of the experiment for performance of pressure relief device, in the case of the thermal sensitive type PRD, a glass bulb type is more effective to flame than a fusible plug type. we confirmed that the rupture pressure of a pressure sensitive type PRD could not be affected by temperature and pressure cycling.

  • PDF