• Title/Summary/Keyword: NFPA

Search Result 151, Processing Time 0.02 seconds

Optimum Design on Fire Resistance of Gas Cylinder Cabinets using Thermal Analysis (열해석을 이용한 가스 실린더 캐비닛의 내화성능 최적설계)

  • Nam, Minseo;Kim, Jiyu;Kim, Euisoo
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.1
    • /
    • pp.34-40
    • /
    • 2022
  • Gas cylinder cabinets have risks such as cylinder explosion and scattering of debris when a fire occurs. These risks are likely to cause gas spills and cause secondary damage. In order to reduce damage, it is very important to secure the fire resistance performance of the gas cylinder cabinet. In foreign countries, NFPA codes in the United States and EN-14470-2 in Europe stipulate fire resistance test standards for gas cylinder cabinets to protect internal cylinders for a certain period of time in a situation where gas cylinder cabinets are exposed to flames. However, in Korea, only internal pressure performance and airtight performance standards are specified, and the target is limited to piping, and research and regulations for the fire resistance performance of gas cylinder cabinets are insufficient compared to overseas. Therefore, in this study, finite element analysis was used to establish fire resistance standards for domestic gas cylinder cabinets. In the event of a fire, optimal conditions are derived in terms of structure and material.

Study on the Prioritization of Management for Each Toxic Chemical Substance in Ansan Smart Hub. (안산스마트허브 유해화학물질별 관리우선순위 선정에 관한 연구)

  • Choi, Bong Seok;Sa, Jae-Hwan;Kim, Min Wook;Jeon, Eui Chan
    • Korean Journal of Hazardous Materials
    • /
    • v.2 no.1
    • /
    • pp.12-17
    • /
    • 2014
  • With a rapid growth of domestic industry in korea, now about 25,000 kinds of chemicals are being distributed, and it has been known that just about 15% of them has toxic substances. Recently, South Koreans have an anxiety about the stability and accidents of chemicals because chemical accidents like Gumi hydrofluoric acid accident have occurred. The U.S. has adopted the systems like EPCRA (Emergency Planning and Community Right-to-Know Act), TRI (Toxic Release Inventory) and TSCA (Toxic Substances Control Act), and is also managing the hazardous chemicals by providing the information about them to its people and site workers. Japan's Ministry of Health, Labor and Welfare also has adopted J-CHECK system and is implementing it to let Japanese people know the information of safety of chemicals about REACH. However, the Korean government has a difficult situation to mediate the different idea with the Korean industry to make lower statute of Pre-legislation registration & evaluation of chemicals that will be implemented and Chemical Material Control Association that is being implemented. Especially city and country areas located in the industrial areas need political improvement focusing on vulnerable area through the check about current situation of hazardous chemicals of jurisdiction and management method, but the information about the management situation of small scale work places is insufficient. Therefore this study set up the urgent management area in Ansan Smart Hub through NFPA code according to the types of accident and dander characteristics of each chemical being used in the companies that have less than 50 workers and deal with chemicals located in Ansan Smart Hub in Gyeonggi-do.

Effectiveness of Friction Loss Calculation Used for Water Mist Fire Extinguishing System on Marine Vessels

  • Lee Kyung-Woo;Kim You-Taek;Lee Young-Ho;Kim Mann-Eung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.1
    • /
    • pp.86-97
    • /
    • 2005
  • Nowadays, Water Mist Fire Extinguishing System is increasingly used in maritime field for various application. The fire extinguishing capability of the system should be verified by hydraulic calculation in the same manner as the conventional water based fire extinguishing system such as sprinkler system. water spray system and etc. Additionally, the review of effectiveness of friction loss calculation method used for hydraulic calculation is needed because the pipe flow characteristic of its piping system has higher Reynolds number than that of the conventional system. In this paper the review work was carried out based on the NFPA Code 750.

A Study on the Development of Computer Software for the Design of Fire Protection System (방화설비계통 설계용 전산소프트웨어 개발에 관한 연구)

  • 이정혜
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.22 no.3
    • /
    • pp.275-284
    • /
    • 1998
  • Standard on the carbon dioxide extinguishing system was prepared by the committed of the national fire protection assocition(NFPA)in USA on 1980. And this code is also applied to the design of a marine fire extinguishing system The most important problem in design is the uniform discharge of $CO_2$ through each nozzle from the high pressure $CO_2$ storage facility. The purpose of this paper is to develop the computer software to design the marine fire protection piping system. By solving the continuity equation energy equation and Bernoulli's equation simulataneously the flowrate in branch pipelines and discharge nozzles can be calculated.

  • PDF

Spray Flow Characteristics of Twin-fluid Water Mist Nozzle for Fire Suppression (2유체 미세 물분무 소화노즐의 분무유동 특성)

  • Kim, Bong-Hwan;Choi, Hyo-Sung;Kim, Dong-Keon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.3
    • /
    • pp.60-66
    • /
    • 2011
  • In the present investigation, experimental studies were conducted on the fire suppression performance of twin-fluid water mist spray which is subjected to thermal radiation in a closed space. Downward-directed water-mist sprays, interacting with an under kerosene pool fire, were investigated in a test facility. The mass mean diameter of water-mist droplets were measured by PMAS under various flow conditions. The developed twin-fluid water mit spray nozzle satisfied the criteria of NFPA 750, Class 1. The mechanism of fire suppression by fine water mist was concluded to be the cooling of the fire surface which leads to the suppression of fuel evaporation. It was proved that the automatic twin-fluid water mist spray system under lower pressures could be applied to an industrial facilities.

A study on the Water Mist Fire Suppression Performance (미세 물 분무 소화 성능에 관한 연구)

  • 김봉환;김용판;문철진;홍철현;이형욱
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.61-65
    • /
    • 2002
  • The present study was numerically and experimentally performed to investigate the fire suppression performance of water mist spray subjected to thermal radiation in closed space. Downward-directed water mist sprays to interact with an under kerosine pool fire were investigated in test facility. The mass mean diameters of water mist droplet were measured by PMAS under various flow conditions. The developed water mist spray nozzle was satisfied to the criteria of NFPA 750, Class 1. The mechanism of the fire suppression by water mist was concluded to be cooling of the fire surface which lead to suppressed of fuel evaporation. It was proved that the water mist spray system under lower pressures could be applied to underground fire protection system.

  • PDF

Rolling Stock Fire Engineering aspect of System Engineering (System Engineering 측면에서 전동차 화재기술관리)

  • Chang, Jung-Hoon;Kang, Chan-Yong
    • Proceedings of the KSR Conference
    • /
    • 2005.05a
    • /
    • pp.163-168
    • /
    • 2005
  • In case of rolling stock, SEMS is generally applied in the advanced countries, but is start stage in our country. SEMS is defined the system engineering management system in order to achieve the optimized train performance among the several client requirements aspect of technical engineering management during the design life cycle. And the fire engineering activities in hong kong EMU project are introduced aspect of SEMS in this paper. The fire engineering at rolling stock in view of SEMS controls to apply the satisfied interior material by the fire safety standards (regulation of the commute urban subway safety guideline by the MOCT, BS 6853, NFPA 130, NF F 16-101) and to minimize the fire load in order that passengers egress safe from the fired rolling stock. The rolling stock in the advanced countries is designed to stand for 15-20 minutes in considering the rolling stock to be fired in tunnel. For passenger fire safety, the passenger evacuation provision and progress is set up.

  • PDF

Review of Code Provisions on Seismic Design of Fire Protection System (소방설비 내진설계에 관한 각국 기준 비교 연구)

  • Lee, Hyun-Jin;Shin, Yi-Chul;Lee, Jae-Young;Seo, Dong-Goo;Han, Byung-Chan;Kim, Jae-Hwan;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.238-241
    • /
    • 2008
  • In this paper, provisions related with the seismic design and equipments of fire protection system are being considered. The provisions from various international codes on seismic design fire protection system were reviewed. The codes, reviewed are, Japanese code, NFPA guideline and Korean code. It is noted that all the codes excepted to korean code consider earthquake effect to evaluate seismic forces and behaviors. But, korean provision are not covered in seismic response in all. A brief description on limitations in korean code is also presented.

  • PDF

The Study on Real Scale Fire Test of Building Exterior Wall Assemblies (건축물 외장재 수직확산 실대형 화재실험에 관한 연구)

  • Kweon, Oh-Sang;Yoo, Yong-Ho;Kim, Heung-Youl
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.295-300
    • /
    • 2011
  • 국내 건축물 외장재의 화재위험성 판단을 위한 기준 설정 및 건축물 외장재 수직확산 방지를 위하여 국내 외 실규모 화재실험을 비교 분석하였다. 현재 미국, 영국 등의 화재안전선진국들에서는 NFPA 285, BS 8414-1 등의 실대형 화재 실험을 통하여 외장재의 화재위험성을 판단하고 있다. 이에 본 연구에서는 국내 외 건축물 외장재의 수직화재확산 성능 평가 방법들의 비교 분석을 통하여 국내 실정에 맞는 실대형의 화재실험 방법을 결정하고자 하였다. 본 결과를 통해 건축물의 단위 공간에서 화재가 발생하여 화재의 성장이 플래시오버에 도달한 후 창문 등의 개구부를 통하여 화염이 출화되었을 때 이러한 화염에 의한 건축물 외장재의 수직화재 확산 성능 평가하는 건축물 외장재 수직확산 실대형 화재실험 장비를 개발하고자 하였다.

  • PDF

A Study to Determine the Quantity of Clean Agent in an Automatic Fire Extinguisher for Switchgear (수배전반용 개별식 자동소화장치를 위한 청정소화약제량 최적산정에 관한 연구)

  • Choi, Young-Kwan;Yoon, Byeong-Don;Shin, Myong-Chul
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.393-396
    • /
    • 2011
  • 설치의 법적규제가 없는 수배전반용 개별식 자동소화장치의 경우, 소화약제량 산정시 설계자마다 체적당 소요가스량, 개구부 면적, 개구면적당 가산량을 다르게 적용하여 같은 크기의 panel 인데도 소화약제량이 다르게 산정되는 경우가 있다. 따라서, 본 논문에서는 수배전반 및 전동기 기동반용 개별식 자동소화장치를 위한 청정소화약제량(HFC-227ea)을 산정하기 위해 NFPA, NFSC를 비교분석하여 최적의 소화약 제량 산정식을 도출하였다.

  • PDF