• Title/Summary/Keyword: NExT

Search Result 71, Processing Time 0.024 seconds

Evaluation of Tendency for Characteristics of MRI Brain T2 Weighted Images according to Changing NEX: MRiLab Simulation Study (자기공명영상장치의 뇌 T2 강조 영상에서 여기횟수 변화에 따른 영상 특성의 경향성 평가: MRiLab Simulation 연구)

  • Kim, Nam Young;Kim, Ju Hui;Lim, Jun;Kang, Seong-Hyeon;Lee, Youngjin
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.1
    • /
    • pp.9-14
    • /
    • 2021
  • Recently, magnetic resonance imaging (MRI), which can acquire images with good contrast without exposure to radiation, has been widely used for diagnosis. However, noise that reduces the accuracy of diagnosis is essentially generated when acquiring the MR images, and by adjusting the parameters, the noise problem can be solved to obtain an image with excellent characteristics. Among the parameters, the number of excitation (NEX) can acquire images with excellent characteristics without additional degradation of image characteristics. In contrast, appropriate NEX setting is required since the scan time increases and motion artifacts may occur. Therefore, in this study, after fixing all MRI parameters through the MRiLab simulation program, we tried to evaluate the tendency of image characteristics according to changing NEX through quantitative evaluation of brain T2 weighted images acquired by adjusting only NEX. To evaluate the noise level and similarity of the acquired image, signal to noise ratio (SNR), contrast to noise ratio (CNR), root mean square error (RMSE) and peak signal to noise ratio (PSNR) were calculated. As a result, both noise level and similarity evaluation factors showed improved values as NEX increased, while the increasing width gradually decreased. In conclusion, we demonstrated that an appropriate NEX setting is important because an excessively large NEX does not affect image characteristics improvement and cause motion artifacts due to a long scan.

T/R Module Development for X-Band Active Phased-Array Radar (능동 위상 배열 레이더용 X-대역 T/R 모듈 개발)

  • Kim, Dong-Yoon;Chong, Min-Kil;Kim, Sang-Keun;Chon, Sang-Mi;Na, Hyung-Gi;Baik, Seung-Hun;Ahn, Chang-Soo;Kim, Seon-Joo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.12
    • /
    • pp.1243-1251
    • /
    • 2009
  • This paper presents design and test results of X-Band Transmit/Receive(T/R) module for active phased-array radar. Active phased array radars typically require solid state T/R modules with high output power, low noise figure, high Third Order Intercept(TOI), and sufficient gain in both transmit and receive. The output power of the module is 9 watts over a wide bandwidth. The noise figure is as low as 2.8 dB. Phase and amplitude are controlled by the 6-bit phase shifter and 5-bit attenuator, respectively. Highly integrated T/R module is achieved by using LTCC(Low Temperature Co-fired Ceramic) multiple layer substrate. The module incorporates a compact digital interface, requires only three supply voltages.

Effects of NEX on SNR and Artifacts in Parallel MR Images Acquired using Reference Scan

  • Heo, Yeong-Cheol;Lee, Hae-Kag;Cho, Jae-Hwan
    • Journal of Magnetics
    • /
    • v.18 no.4
    • /
    • pp.422-427
    • /
    • 2013
  • The aim of this study was to investigate effects of the number of acquisitions (NEX) on signal-to-noise (SNR) and artifacts in SENSE parallel imaging of magnetic resonance imaging (MRI). 3.0T MR System, 8 Channel sensitivity encoding (SENSE) head coils were used along with an in-vivo phantom. Reference sequence of 3D fast field echo (FFE) was consisted of NEX values of 2, 4, 6, 8, 10 and 12. The T2 turbo spin echo (TSE) sequence used for exams achieved SENSE factors of 1.2, 1.5, 1.8, 2.0, 2.2, 2.5, 2.8, 3.0, 3.2, 3.5, 3.8 and 4.0. Exams were conducted five times for each SENSE factor to measure signal intensity of the object, the posterior phase-encode direction and frequency direction. And SNR was calculated using mean values. SENSE artifacts were identified as background signal intensity in the phase-encoded direction using MRIcro. It was found that SNR increased but SENSE artifacts reduced with NEX of 4, 8 and 12 when the NEX increased in reference scan. It is therefore concluded that image quality can be improved with NEX of 4, 8 and 12 for reference scanning.

Bioequivalence of Nex capsule to Axid capsule (Nizatidine 150 mg) (액시드 캅셀(니자티딘 150 mg)에 대한 넥스 캅셀의 생물학적 동등성)

  • Kim, Ji-Man;Lee, Sang-Bong;Jeon, Seong-Sill;Shin, Young-Hee
    • Journal of Pharmaceutical Investigation
    • /
    • v.34 no.1
    • /
    • pp.43-48
    • /
    • 2004
  • The purpose of the present study was to evaluate the bioequivalence of two nizatidine capsules, Axid (Lilly Korea Pharm. Co., Ltd.) and Nex (Bi-nex Pharm. Co., Ltd.), according to the guidelines of Korea Food and Drug Administration (KFDA). The nizatidine release from the two nizatidine capsules in vitro was tested using KP Apparatus method with various dissolution media (pH 1.2, 4.0, 6.8 buffer solutions and water). The dissolution prefers of two nizatidine capsules were very similar at all dissolution media. Twenty four normal male volunteers were divided into two groups with a randomized 22 crossover study. After two capsules (300 mg nizatidine) were orally administrated, blood was taken and the concentrations of nizatidine in serum were determined using HPLC with UV detector. The pharmacokinetic parameters such as $AUC_t$, $C_{max}$ and $T_{max}$ were determined. The result showed that the differences in $AUC_t$, $C_{max}$ and $T_{max}$ between two nizatidine capsules based on the Axid were -6.16%, -8.26% and -1.82%, respectively. There were no sequence effects between two capsules in these parameter. The 90% confidence intervals using logarithmically transformed data were within the acceptance range of log(0.8) to log(125)(e.g., $log(0.91){\sim}log(0.97)$ and $log(0.85) {\sim}log(0.99)$ for $AUC_t$ and $C_{max}$ respectively), indicting that Nex capsule is bioequivalent to Axid capsule.

Development of Planar Active Electronically Scanned Array(AESA) Radar Prototype for Airborne Fighter (항공기용 평면형 능동 전자주사식 위상 배열(AESA) 레이더 프로토 타입 개발)

  • Chong, Min-Kil;Kim, Dong-Yoon;Kim, Sang-Keun;Chon, Sang-Mi;Na, Hyung-Gi
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.12
    • /
    • pp.1380-1393
    • /
    • 2010
  • This paper presents a design, fabrication and the test results of planar active electronically scanned array(AESA) radar prototype for airborne fighter applications using transmit/receive(T/R) module hybrid technology. LIG Nex1 developed a AESA radar prototype to obtain key technologies for airborne fighter's radar. The AESA radar prototype consists of a radiating array, T/R modules, a RF manifold, distributed power supplies, beam controllers, compact receivers with ADC(Analog-to-Digital Converter), a liquid-cooling unit, and an appropriate structure. The AESA antenna has a 590 mm-diameter, active-element area capable of containing 536 T/R modules. Each module is located to provide a triangle grid with $14.7\;mm{\times}19.5\;mm$ spacing among T/R modules. The array dissipates 1,554 watts, with a DC input of 2,310 watts when operated at the maximum transmit duty factor. The AESA radar prototype was tested on near-field chamber and the results become equal in expected beam pattern, providing the accurate and flexible control of antenna beam steering and beam shaping.

Ka-band Compact AESA Antenna Unit Design for Seeker

  • Bongmo Kang;Ikjong Bae;Jaesub Han;Youngwan. Kim;Jaehyun Shin;Jihan Joo;Seonghyun Ryu
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.16 no.1
    • /
    • pp.330-338
    • /
    • 2024
  • In this paper, a Ka-band high-output active phased array antenna device applicable to small radars and seekers was designed, and the improved performance was studied. The radiation device assembly consists of 1x8 arrangements, and the step flared notch antenna type. It shows low active reflection loss characteristics in broadband, and low loss characteristics by applying the air-strip feeding structure, and is designed to enable beam steering up to 45 degrees. The TRM(transmit receive module) output power is more than 2.0W per channel using GaN HPA in the transmitting path, and satisfies more than 25.0 dB gain and less than 6.0 dB noise figure in the receiving path. Accordingly, the Effective Isotropically Radiated Power(EIRP) of the antenna unit shows the performance of 0.00 dB or more and the receive gain-to-noise temperature ratio(G/T) of 0.00 dB/k or more. For demonstration, we have designed aforementioned planar array antenna which consists of 64 radiating elements having a size within 130 mm x 130 mm x 300 mm and weight of less than 4.9 kg..

Numerical Analysis for Thermal Design of Electronic Equipment Using Phase Change Material (상변화 물질을 이용한 전자 장비 방열 설계의 수치 해석적 연구)

  • Lee, Dong Kyun;Lee, Won Hee;Park, Sung Woo;Kang, Sung Wook;Cho, Ji Hyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.4
    • /
    • pp.285-291
    • /
    • 2017
  • In this study, a case analysis for thermal design of electronic equipment using a phase change material(PCM) was performed numerically using ANSYS Fluent. Experiments were conducted to find the temperature increase(${\Delta}T_m$), melting temperature($T_m$), and volume expansion of the PCM under the melting process. To verify the accuracy of the Fluent solver model, $T_m$, ${\Delta}T_m$, and the melting time were compared with experimental results. To simulate the temperature stagnation phenomenon under the melting process, the equivalent specific heat method was applied to calculate the thermal properties of the PCM in the solver model. To determine the thermal stability of electronic equipment, we paid special attention to finding a thermal design for the PCM using fins. Further, an additional numerical analysis is currently underway to find an optimum design.

DVB-S2-based T4 class common data link performance improvement plan for UAV system application (무인기 체계 적용을 위한 DVB-S2 기반 T4급 공용데이터링크 성능 개선방안)

  • Bae, Jongtae;Baek, Seongho;Oh, Jimyung;Lee, Sangpill;Song, Choongho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.26 no.12
    • /
    • pp.1846-1854
    • /
    • 2022
  • The sophistication and diversification of mission equipment for surveillance and reconnaissance is leading to a demand for large-capacity public data links. Overseas, a T4 class(274Mbps) common data link was applied to the Global hwak, a high-altitude unmanned aerial vehicle, and various research and development are being conducted in Korea. In this paper, we propose a structure in which pilot is additionally applied to improve SNR performance while minimizing data transmission rate loss in the DVB-S2 frame structure, which is a european satellite broadcasting standard, for high-capacity transmission of T4 class or higher in the common data link. For the performance evaluation of the proposed structure, the performance of the DVB-S2 was compared and analyzed by simulating the UAV data link channel environment. As a result of simulation, 0.15% of transmission rate loss occurred at T4 class transmission rate compared to DVB-S2 in the proposed structure, but improved SNR reception performance of 0.2~0.3dB was confirmed in the UAV channel environment.

Alteration Analysis of Normal Human Brain Metabolites with Variation of SENSE and NEX in 3T Multi Voxel Spectroscopy (3T Multi Voxel Spectroscopy에서 SENSE와 NEX 변화에 따른 정상인 뇌 대사물질 변화 분석)

  • Seong, Yeol-Hun;Rhim, Jae-Dong;Lee, Jae-Hyun;Cho, Sung-Bong;Woo, Dong-Chul;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.256-262
    • /
    • 2008
  • To evaluate the metabolic changes in normal adult brains due to alterations SENSE and NEX (number of excitation) by multi voxel MR Spectroscopy at 3.0 Tesla. The study group was composed of normal volunteers (5 men and 8 women) with a mean ($\pm$ standard deviation) age of 41 (${\pm}11.65$). Their ages ranged from 28 to 61 years. MR Spectroscopy was performed with a 3.0T Achieva Release Version 2.0 (Philips Medical System-Netherlands). The 8 channel head coil was employed for MRS acquisition. The 13 volunteers underwent multi voxel spectroscopy (MVS) and single voxel spectroscopy (SVS) on the thalamus area with normally gray matter. Spectral parameters were as follows: 15 mm of thickness; 230 mm of FOV (field of view); 2000 msecs of repetition time (TR); 288 msecs of echo time (TE); $110{\times}110$ mm of VOI (view of interest); $15{\times}15{\times}15$ mm of voxel size. Multi voxel spectral parameters were made using specially in alteration of SENSE factor (1~3) and 1~2 of NEX. All MRS data were processed by the jMRUI 3.0 Version. There was no significant difference in NAA/Cr and Cho/Cr ratio between MVS and SVS likewise the previous results by Ross and coworkers in 1994. In addition, despite the alterations of SENSE factor and NEX in MVS, the metabolite ratios were not changed (F-value : 1.37, D.F : 3, P-value : 0.262). However, line-width of NAA peak in MVS was 3 times bigger than that in SVS. In the present study, we demonstrated that the alterations of SENSE factor and NEX were not critically affective to the result of metabolic ratios in the normal brain tissue.

  • PDF

A Study on the Establishment of Reliability Growth Planning for One-shot System (원샷시스템의 신뢰도 성장 계획 설정 방안)

  • Seo, Yang Woo;Jeon, Dong Ju;Kim, So Jung;Kim, Yong Geun
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.16 no.1
    • /
    • pp.1-8
    • /
    • 2020
  • In this paper we proposed to develop the reliability growth planning for the One-shot system using the PM2-Discrete model. The PM2-Discrete is the methodology specifically developed for discrete systems and is the first quantitative method available for formulating detailed plans in the discrete usage domain. First, the parameters RG, RI, T, MS and d of the PM2-Discrete model are set. Second, the case analysis was performed on One-shot system A. Third, the input parameter values were applied to drive the R(t) equation. Finally, using RGA 11 Software, the reliability Growth Planning Curve of One-shot system A was constructed. Also, the sensitivity analyses are performed for the changes of model parameters. The results of this study can be usefully used in establishing the reliability growth planning curve of the One-shot system.