Browse > Article
http://dx.doi.org/10.4333/KPS.2004.34.1.043

Bioequivalence of Nex capsule to Axid capsule (Nizatidine 150 mg)  

Kim, Ji-Man (College of Pharmacy, Kyungsung University)
Lee, Sang-Bong (College of Pharmacy, Kyungsung University)
Jeon, Seong-Sill (Wallece Memorial Baptist Hospital)
Shin, Young-Hee (College of Pharmacy, Kyungsung University)
Publication Information
Journal of Pharmaceutical Investigation / v.34, no.1, 2004 , pp. 43-48 More about this Journal
Abstract
The purpose of the present study was to evaluate the bioequivalence of two nizatidine capsules, Axid (Lilly Korea Pharm. Co., Ltd.) and Nex (Bi-nex Pharm. Co., Ltd.), according to the guidelines of Korea Food and Drug Administration (KFDA). The nizatidine release from the two nizatidine capsules in vitro was tested using KP Apparatus method with various dissolution media (pH 1.2, 4.0, 6.8 buffer solutions and water). The dissolution prefers of two nizatidine capsules were very similar at all dissolution media. Twenty four normal male volunteers were divided into two groups with a randomized 22 crossover study. After two capsules (300 mg nizatidine) were orally administrated, blood was taken and the concentrations of nizatidine in serum were determined using HPLC with UV detector. The pharmacokinetic parameters such as $AUC_t$, $C_{max}$ and $T_{max}$ were determined. The result showed that the differences in $AUC_t$, $C_{max}$ and $T_{max}$ between two nizatidine capsules based on the Axid were -6.16%, -8.26% and -1.82%, respectively. There were no sequence effects between two capsules in these parameter. The 90% confidence intervals using logarithmically transformed data were within the acceptance range of log(0.8) to log(125)(e.g., $log(0.91){\sim}log(0.97)$ and $log(0.85) {\sim}log(0.99)$ for $AUC_t$ and $C_{max}$ respectively), indicting that Nex capsule is bioequivalent to Axid capsule.
Keywords
Nizatidine; Axid; Nex; Bioequivalence; HPLC;
Citations & Related Records
연도 인용수 순위
  • Reference
1 P. Vallani, M.B. Regazzi, M. Ercolini, M. Tizzoni and D. Savio, The effect of aging on the pharmacokinetic of nizatidine, Eur. J. Drug Metab. Pharmacoldnetic. Spec, 3, 205-210 (1991)
2 T.J. Sullivan, J.H. Reese, L. Jauregui, K. Miller, L. Levine and K.A. Bachman, Short Report: A comparative study of the interaction between antacid and Hrreceptor antagonist, Aliment Pharmacol. Ther., 8, 123-126 (1994)   DOI   ScienceOn
3 식품의약품안전청 고시 제 2002-60호, 생물학적동등성시험 기준, 식품의약품안전청 (2002. 11. 22).
4 A. Tracqui, P. Kintz and P. Mangin, Determination of nizatidine and two of its main metabolites in human serum using high performance liquid chromatography, J. Chromatography, Biomedical Application, 529, 369-376 (1990)   DOI
5 G. Carlucci, High performance liquid chromatographic assay for nizatidine, a new Hz blocker, in human plasma and urine using disposable solid phase extraction column, J. Chromatography, Biomedical Application, 525, 490-494 (1990)   DOI   ScienceOn
6 Statistical Solutions Ltd., Equiv Test 2.0, UK (2001)
7 J.M. Kim, S.B. Lee and YH. Shin, Simple high-perfor-mance liquid chromatographic determination of nizatidine in human serum. The 40th International Symposium of Korean Society of Life Science, p. 5 (2003)