• Title/Summary/Keyword: NEC

Search Result 233, Processing Time 0.031 seconds

호주 항공산업의 중심지-멜버른

  • Sim, Jae-Gyu
    • Defense and Technology
    • /
    • no.9 s.139
    • /
    • pp.40-53
    • /
    • 1990
  • 세계시장에서 멜버른의 기록은 매우 인상적이다. 이곳 회사들은 국내외 보잉 747 창정비시설과 정비시설등을 공급하였고, 록히드사엔 항공기 격납고를, GE사엔 F404, T700 엔진을, NEC사엔 인공위성 부품을, 프랑스의 에이버스 항공사엔 기체구조물(Floor support structure), MD사엔 MDX헬기의 기체를, 보잉사엔 복합재료를 사용한 Rudder시스템을 공급하였다. 생산품의 3분의 1 이상은 해외수출을 하며, 이외의 많은 생산품과 부품은 미국, 유럽, 아시아지역등에 판매하고 있다.

  • PDF

Design and Fabrication of two-stage Low Noise Amplifier for 24㎓ (24㎓ 2단 저잡음 증폭기의 설계 및 제작)

  • 한석균
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.7
    • /
    • pp.1374-1379
    • /
    • 2003
  • In this paper, twoㆍstage low noise amplifier(LNA) for 24㎓ is designed and fabricated using NE450284C HJ-FET of NEC CO. In order to get noise figure and input VSWR to be wanted it is considered input VSWR and noise figure simultaneously in matching-circuit designing. The fabricated two-stage low noise mph u has the gai of 16.6㏈, input VSWR of 1.6, and output VSWR under 1.5.

슈퍼컴퓨터 3호기 기술 분석

  • Kim, Jeong-Ho
    • Journal of Scientific & Technological Knowledge Infrastructure
    • /
    • s.6
    • /
    • pp.140-147
    • /
    • 2001
  • 전체가 벡터형 단일 기종이었던 이전의 두 시스템과는 달리 슈퍼컴퓨터 3호기의 경우는 시스템 전체 규모의 대부분을 범용 RISC프로세서를 사용하는 IBM Regatta 시스템이 차지하고 있고 벡터형 시스템인 NEC SX-5의 규모는 상대적으로 매우 작은 편이다. 따라서 본고에서는 이러한 형태의 시스템 도입이 결정된 과정과 그런 결론을 내게 만든 슈퍼컴퓨팅 환경의 변화와 슈퍼컴퓨팅 기술의 동향에 대해 살표보고 나아가서 앞으로의 변화 추세를 도입이 결정된 시스템을 중심으로 살펴보고자 한다.

  • PDF

The Surface fCO2 Distribution of the Western North Pacific in Summer 2002 (2002년 여름 북서태평양 표층 해수의 이산화탄소 분포 특성)

  • Choi, Sang-Hwa;Kim, Dong-Seon;Shim, Jeong-Hee;Min, Hong-Sik
    • Ocean and Polar Research
    • /
    • v.28 no.4
    • /
    • pp.395-405
    • /
    • 2006
  • We measured the fugacity of $CO_2$ $(fCO_2)$, temperature, salinity, nutrients and chlorophyll a in the surface water of the western North Pacific $(4^{\circ}30'{\sim}33^{\circ}10'N,\;144^{\circ}20'{\sim}127^{\circ}35'E)$ in September 2002. There were zonally several major currents which have characteristics of specific temperature and salinity (NECC, North Equatorial Counter Current; NEC, North Equatorial Current; Kuroshio etc.). Surface $fCO_2$ distribution was clearly distinguished into two groups, tropical and subtropical areas of which boundary was $20^{\circ}N$. In the tropical Int surface $fCO_2$ was mainly controlled by temperature, while in the subtropical area, surface $fCO_2$ was dependent on total inorganic carbon contents. Air-sea $CO_2$ flux showed a large spatial variation, with a range of $-0.69{\sim}0.79 mmole\;m^{-2}day^{-1}$. In the area of AE (Anticyclonic Eddy), SM(Southern Mixed region) and NM (Northern Mixed region), the ocean acted as a weak source of $CO_2$ $(0.6{\sim}0.79 mmole\; m^{-2}day^{-1})$. In NECC, NEC, Kuroshio and ECS (East China Sea), however, the fluxes were estimated to be $-0.3mmole\; m^{-2}day^{-1})$ for the first three regions and $-1.2mmole\; m^{-2}day^{-1})$ for ECS respectively, indicating that these areas acted as sinks of $CO_2$. The average air-sea flux in the entire study area was $0.15mmole\;m^{-2}day^{-1})$, implying that the western North Pacific was a weak source of $CO_2$ during the study period.

A Study on Design for Relay Station Antennas with U-shaped Back Plate Structure (ㄷ자형 Back Plate를 가진 중계국안테나의 설계에 관한 연구)

  • 민경식;임정남;김동일;정세모;이돈신
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.2 no.4
    • /
    • pp.643-652
    • /
    • 1998
  • This paper presents the characteristics of a relay station antenna with the newly designed back-plate structure which is composed of the U-shaped metal plate for suppression of the back lobe by edge diffraction. The back lobe level of the conventional type was about -20 dB in the -z direction ( 180 ) . In order to improve the characteristics, the U-shaped mesh type metal plate is considered, where the design condition of the model antenna satisfies the wide null point angle range with the back lobe level of -30 dB below in the -z direction. The design parameters with the minimum back lobe level such as the dipole length, the distance between dipole elements and the back plate size have been found by using the released NEC Win Pro code. The calculated and measured back lobe Bevel of model antenna have been obtained 48.48 dB and -45 dB at 325 MHz, respectively.

  • PDF

Diagnosis and Therapy of Primary Hepatic Neuroendocrine Carcinoma: Clinical Analysis of 10 Cases

  • Wang, Li-Ming;An, Song-Lin;Wu, Jian-Xiong
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.6
    • /
    • pp.2541-2546
    • /
    • 2014
  • Background: Primary hepatic neuroendocrine carcinoma (PHNEC) is rarer than extrahepatic gastrointestinal neuroendocrine carcinoma (NEC). It is difficult to make a correct diagnosis and poses a challenge for management. Materials and Methods: Ten PHNEC patients were admitted to our hospital from June 2006 to June 2011. Laboratory tests and imaging scans were performed for diagnosis and exclusion of extrahepatic NEC. All patients were AFP - and CA199-. Seven patients had solid tumors with cystic changes on ultrasonography, CT and/or MRI. For the initial treatment, four patients received combined-therapy and six monotherapy. Considering overall treatment, six patients received combined-therapy and four patients monotherapy. Staging criteria of primary hepatocellular carcinoma (PHC, AJCC 7th edition) were used to differentiate the stage of all patients: 3 patients were stage I, 2 stageII, 4 patients stageIII and 1 stageIV. All patients were followed up and clinical data were gathered. Results: The median follow-up duration was 38.5 months. The 1-year, 2-year, 3-year and 6-year disease-free survival was 80.0%, 46.2% and 46.2% and 0% respectively. The overall survival rates were 100%, 67.1%, 67.1% and 33.6% respectively. Patients in early-stages (I/II) had similar disease-free and overall survival as those in advanced-stages (III/IV). Patients with monotherapy had significant shorter disease-free and overall survival than the patients with combination-therapy. Conclusions: PHNEC has a unique specificity during its occurrence and development. The staging criteria of PHC might not be suitable for the PHENT. More convenient and effective features need to be found in imaging and laboratory detection. Surgical resection, TACE, chemotherapy and radiofrequency ablation should be performed in combination and actively for patients with PHNEC or recurrence to get the best effectiveness; they might extend the disease-free and overall survival.

Numerical Calculation for Input Impedance of a Conductor Located in the Loss Media (손실 매질에 위치한 도체의 입력임피던스 수치계산)

  • Ahn, Chang-Hwan
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.3
    • /
    • pp.230-236
    • /
    • 2013
  • This paper presents the numerical calculation for input impedance of a conductor located in the loss media by using the program with MATLAB. The input impedances of the conductor were numerically calculated with the moment of method. To increase an accuracy of results, the Galerkin's method which both the basic function and the weight function are the triangle function was applied. And by applying the modified image method, image sources of the conductor located in air were considered. According to the comparison between the current distributions at the conductor which were calculated with the MATLAB program and the NEC program, the reliability of the self-made program with MATLAB was obtained. In case of the conductor located in soil, which length are 1 m and 2 m, the input impedance were simulated as a function of both a conductivity and a frequency. Finally, input impedances and phases of the conductor located in soil were measured, and those results were compared with simulated results which calculated under the same conditions.

Numerical Calculation for Impedance of Horizontal Ground Electrode for Information and Communication Facilities with Considering Characteristics of Permittivity in Soil (토양의 유전율 특성을 고려한 정보통신설비용 수평접지전극의 임피던스 계산)

  • Ahn, Chang-Hwan
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.10
    • /
    • pp.245-251
    • /
    • 2013
  • An impedance of ground electrode for information and communication facilities has a significant relationship with the electrical characteristics of soil where the ground electrode is buried. Especially, the impedance of ground electrode is directly affected by the characteristics of permittivity and conductivity in soil as a function of a frequency of an applied electric field. The program based on the electromagnetic field model was developed in MATLAB. Because both permittivity and conductivity can not be modified in commercial programs. The permittivity of soil was applied with the Debye equation which is a model of dielectric relaxation. And the empirical equation of the conductivity in soil was quoted in other paper. In order to confirm the reliability of proposed program, the impedance measurement of ground electrode was carried out, which were compared with the results of simulation in commercial program. In result, it was confirmed that the impedance and phase different simulated by appling the characteristics of permittivity and conductivity in soil are in good agreement with the measured values than results of NEC.

Application of Commercial PIN Photodiodes to develope Gamma-Ray Dosimeters (감마선 선량계를 개발하기 위한 상용 PIN 포토 다이오드의 응용)

  • Jeong, Dong-Hwa;Kim, Sung-Duck
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.4
    • /
    • pp.274-280
    • /
    • 2000
  • This paper deals with an experimental study to apply commercial semiconductors to measure radiation dose rate for gamma ray. Since the low cost, small size, high efficiency and ruggedness of silicon photodiodes make them attractive photodetectors, they coulde be effectively used in measuring any radiation such as gamma ray. Most PN photodiodes show that the reverse current increases when the light is increased. Therefore the depletion region of them have influence on the reverse current, so we choose silicon PIN photodiodes with large depletion region. In order to detect radiation dose rate and then, to apply in developing any gamma ray dosimeter, some examinations and experiments were performed to PIN photodiodes in this work. Two kinds of PIN photodiodes, such as NEC's PH302 and SIEMENS's BPW34, were tested in a Co-60 gamma irradiation facility with a semiconductor parameter analyzer. As a result, we found that such PIN photodiodes present good linearity in diode current characteristics with dose rate. Therefore silicon PIN photodiodes could be suitably used in designing gamma ray dosimeters.

  • PDF

Lactobacillus reuteri DSM 17938 Improves Feeding Intolerance in Preterm Infants

  • Kaban, Risma K.;Wardhana, Wardhana;Hegar, Badriul;Rohsiswatmo, Rinawati;Handryastuti, Setyo;Amelia, Novie;Muktiarti, Dina;Indrio, Flavia;Vandenplas, Yvan
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.22 no.6
    • /
    • pp.545-553
    • /
    • 2019
  • Purpose: Feeding tolerance is extremely important in preterm infants. This study aimed to evaluate whether preterm infants receiving Lactobacillus reuteri DSM 17938 would develop fewer symptoms of feeding intolerance. Secondary outcomes were duration of parenteral nutrition, time to reach full feeding, length of hospital stay, sepsis, necrotizing enterocolitis (NEC), diarrhea, and mortality. Methods: This double-blind randomized controlled trial of L. reuteri DSM 17938 versus placebo included 94 neonates with a gestational age of 28-34 weeks and birth weight of 1,000-1,800 g. Results: Feeding intolerance (vomiting and/or distension) was less common in the probiotic group than in the placebo group (8.5% vs. 25.5%; relative risk, 0.33; 95% confidence interval, 0.12-0.96; p=0.03). No significant intergroup differences were found in proven sepsis, time to reach full feeding, length of hospital stay, or diarrhea. The prevalence of NEC (stages 2 and 3) was 6.4% in the placebo group vs. 0% in the probiotic group (relative risk, 1.07; 95% confidence interval, 0.99-1.15; p=0.24). Mortality rates were 2.1% in the probiotic group and 8.5% in the placebo group, p=0.36). Conclusion: The administration of L. reuteri DSM 17938 to preterm infants was safe and significantly reduced feeding intolerance. No significant differences were found in any other secondary outcomes.