• 제목/요약/키워드: NDZ

검색결과 24건 처리시간 0.029초

주기적 위상 변동 기법을 이용한 새로운 단독운전 검출 기법 (Novel Anti-islanding method using phase shift with a periodic function)

  • 정영석;최재호;소정훈;유병규;유권종
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.1153-1154
    • /
    • 2006
  • This paper proposes the optimal design method based on NDZ analysis to secure the islanding defection ability and to maintain the stability and power quality when the grid is connected. A PSiM-based model and analysis of the system is presented, specialty aimed at improving the effectiveness of phase shift anti-islanding method with frequency feedback, which causes the inverter current to be generated slightly lower or higher in frequency than the frequency of the terminal voltage. The proposed method can cause frequency jump with leading and lagging phase of output current in two line cycles. As a result, the proposed algorithm is more sensitive and reliable than the conventional phase shift method. Experimental results, on a 3 kW inverter connected to 220 V, 60 Hz utility, are discussed.

  • PDF

계통연계형 태양광발전 인버터에 사용된 AFD기법의 다양한 부하에 따른 단독운전 불검출영역에 대한 고찰 (A Study of Non-Detection Zone using AFD Method applied to Grid-Connected Photovoltaic Inverter for a variety of Loads)

  • 고문주;최익;최주엽
    • 한국태양에너지학회 논문집
    • /
    • 제26권1호
    • /
    • pp.91-98
    • /
    • 2006
  • Islanding phenomenon of utility-connected photovoltaic power conditioning systems(PV PCS) can cause a variety of problems and must be prevented. If the real and reactive power supplied by PV PCS are closely matched to those of load, islanding detection by passive methods becomes difficult. The active frequency drift(AFD) method, called the frequency bias method, enables islanding detection by forcing the frequency of the voltage in the islanding to drift up or down. In this paper, non-detection zone(NDZ) of AFD is analyzed for the islanding detection method of utility-connected PV PCS by the simulation software tool PSIM.

슬립모드 방식을 이용한 단독운전 검출기법의 모델링과 평가 (Modeling and Evaluation of Slip-Mode Frequency Shift Method for Anti-islanding Method)

  • 유병규;정영석;소정훈;유권종
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.520-522
    • /
    • 2005
  • Islanding phenomenon is undesirable because it lead to a safety hazard to utility service personnel and may cause damage to power generation and power supply facilities as a result of unsynchronized reclosure. In order to prevent this phenomenon, various anti-islanding methods have been studied. Even though the slip mode frequency shift (SMS) method has been regarded as a highly effective anti-islanding method, the analytical design method of that was not cleared. This paper proposes a modeling of the SMS method using non-detection zone (NDZ) and evaluation of the method according to the test conditions of IEEE Std. 929-2000. The SMS method is derived analytically through the modeling and verified visually by simulation and experiment.

  • PDF

PMSG 기반 풍력발전 시스템 계통연계 인버터의 새로운 단독운전방지 기법 (A Novel Anti-islanding Method of a Grid-connected Inverter for a PMSG-based Wind Power Generation System)

  • 강성욱;김경화
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 전력전자학술대회 논문집
    • /
    • pp.427-428
    • /
    • 2013
  • 풍력발전과 같은 분산전원이 계통에 연계되어 운전될 경우, 계통연계 규정에 따라 운전해야 한다. 특히 계통사고에 의해 계통과 분리되었음에도 불구하고, 지속적으로 운전하는 것을 단독운전 이라 한다. 이러한 단독운전은 전기설비의 손상을 일으킬 수 있으므로 계통연계 규정에 따라 이를 빠르고 정확하게 검출하여야 한다. 본 논문에서는 이러한 단독운전을 검출하기 위해서 NDZ(Non-Detecton Zone)를 갖지 않는 고조파 주입 기법의 새로운 고조파 계산 및 검출 알고리즘 제안한다.

  • PDF

무효전력 제어를 통한 새로운 독립운전 검출법 (A Novel Method for Anti-Islanding Using Reactive Power Control)

  • 정진범;최봉주;안강순;김희준
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권4호
    • /
    • pp.208-216
    • /
    • 2005
  • Recently, the study of islanding phenomenon, maintains its operation even when the utility grid is removed has lead to the trend of utility interactive inverters in photovoltaic generation systems. In this paper, a novel Anti-islanding method is presented. the proposed method can keep the real average power component constant by MPPT control and cause the load current frequency with only change of reactive power component under the islanding condition. its periodical change of Reactive power component can decrease the NDZ(Non-Detective zone) so that the detection of various loads will be possible. the insufficient effect if additional reactive power component to the grid is proved theoretically and the islanding detection is also confirmed from a experimental result with a inverter for 3kW photovoltaic generation system applied the proposed Anti-islanding method.

슬립모드 주파수변이 방식의 단독운전 검출법의 분석과 모델링 (Analysis and Modeling of Slip Mode Frequency Shift Method for Anti-islanding)

  • 유병규;정영석;소정훈;유권종
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1699-1701
    • /
    • 2005
  • Islanding phenomenon is undesirable because it lead to a safety hazard to utility service personnel and may cause damage to power generation and rower supply facilities as a result of unsynchronized reclosure. In order to prevent this phenomenon, various anti-islanding methods have been studied. Even though the slip mode frequency shift(SMS) method has been regarded as a highly effective anti-islanding method, the analytical design method of that was not cleared. This paper proposes a modeling of the SMS method using non-detection tone(NDZ) and evaluation of the method according to the test conditions of IEEE Std. 929-2000. The SMS method is derived analytically through modeling and verified visually by simulation and experiment.

  • PDF

Rapid Screening Method for the Solid-Phase Extraction and GC/MS analysis of Diazepam.

  • Choi, Hwa-Kyung;Lee, Ju-Seon;Choi, Hye-Young;Woo, Sang-Hee;Park, Yoo-Sin;Chung, Hee-Sun
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2003년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.2-2
    • /
    • pp.118.3-119
    • /
    • 2003
  • Diazepam (DZ) is one of the most frequently prescribed drugs as an antianxiety agent, muscle relaxant, and anticovulsant and sometimes causes intoxication due to accidental overdose, misuse or abuse. Screening or confirmation methods for DZ and NDZ in plasma are very important for clinical and toxicological studies and in forensic cases. GC/MS assay with SPE was developed for the determination of diazepam and its metabolite, nordiazepam in human plasma. Diazepam in plasma was extracted by a rapid and sensitive procedure based on C18 bonded-phase extraction. (omitted)

  • PDF

계통연계형 태양광 인버터 병렬운전 상황에서의 단독운전 검출 (Islanding Detection for Grid-connected PV Inverter under Parallel Operation)

  • 조영민;김동균;송승호;최익;이영권;조상윤;최주엽
    • 전력전자학회논문지
    • /
    • 제21권4호
    • /
    • pp.283-289
    • /
    • 2016
  • Islanding protection of a grid-connected photovoltaic (PV) inverter is a key function for standards compliance. Unintentional islanding results in safety hazards, reliability, and many other issues. Therefore, many anti-islanding schemes have been examined. However, existing anti-islanding schemes have poor power quality and non-detection zone issues. Moreover, most schemes have problems that deteriorate the performance of islanding detection under parallel operation. Therefore, this paper proposes a novel anti-islanding scheme that has negligible power quality degradation and has no non-detection zone and islanding detection under a parallel operation. Both simulation and experimental results validate the proposed scheme.

중요부하를 갖는 계통연계형 인버터의 고조파주입에 의한 단독운전방지 기법 (Anti-islanding Method by Harmonic Injection for Utility Interactive Inverter with Critical Load)

  • 오형민;최세완;김태희;이기풍;이태원
    • 전력전자학회논문지
    • /
    • 제17권4호
    • /
    • pp.315-321
    • /
    • 2012
  • The utility-interactive inverter with critical loads should supply continuous and stable voltage to critical loads even during the grid fault. The conventional control method which performs current control for grid-connected mode and voltage control for stand-alone mode undergoes the critical load voltage variation during grid fault. The critical load voltage may have large transient when the inverter performs mode transfer after the islanding detection. Recently, the indirect current control method which does not have the transient state during not only islanding detection but also the mode transfer has been proposed. However, since the voltage control is maintained even during the grid-connected mode it is difficult to detect the islanding. This paper proposes an active anti-islanding method suitable for the indirect current control method which does not have NDZ(Non-Detection Zone).

계통연계형 태양광 인버터의 단독운전 방지를 위한 새로운 알고리즘 개발 (Development of Novel Algorithm for Anti-Islanding of Grid-Connected PV Inverter)

  • 최정식;고재섭;정동화
    • 조명전기설비학회논문지
    • /
    • 제25권10호
    • /
    • pp.76-86
    • /
    • 2011
  • This paper proposes novel algorithm for anti-islanding of grid-connected photovoltaic(PV) inverter. The islanding of PV systems can cause a variety of problems such as deterioration in power quality and electric shock. To prevent islanding, many anti-islanding methods are researched. Typical methods of anti-islanding are active frequency drift(AFD) and active frequency drift positive feedback(AFDPF). However, the AFD has problem that widely exists non diction zone(NDZ). The AFDPF is a method that improves the AFD method and is detected islanding by changing the chopping fraction(cf). However, The AFDPF does not detect when cf is very small and does not satisfy the IEEE Std. 929-2000 when cf is very big. Therefore, this paper proposes novel anti-islanding method that is simple to implement using virtual resister. The anti-islanding method proposed in this paper is compared with conventional method. The validity of this paper is proved using this result.