• Title/Summary/Keyword: NCC

Search Result 154, Processing Time 0.028 seconds

Derivation of Transfer Function for the Cross-Coupled Filter Systems Using Chain Matrices

  • Um, Kee-Hong
    • International journal of advanced smart convergence
    • /
    • v.7 no.1
    • /
    • pp.7-14
    • /
    • 2018
  • In this paper, we derive a transfer function of cross-coupled microwave filter systems by using a characteristics of chain matrices. Depending on the lumped element of capacitor or inductor, the cross-coupled system is negatively- or positively system. We used a ladder network as a starting system composed of several subsystems connected in chain. Each subsystem is descrived by Laplace impedance. By solving the transmission zero characteristic equation derived from the cascaded subsystems, we can find the zeros of filter system with externally cross-coupled lumped elements. With the cross-coupled elements of capacitors, the numerator polynomial of system transfer function is used to locate the quadruplet zeros in complex plane. We show the polynomoials of numerator and denominator of cascaded transfer function, obtaining the zeros of the cross-coupled system.

The Structure Of The New EMS in KEPCO (한국전력공사의 차세대 EMS 구상)

  • Yu, Sung-Chul;Kim, Chung-Kil;Kim, Jae-Ki;Lee, In-Kyu;Kim, Sung-Hak
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.893-895
    • /
    • 1996
  • This paper presents the concept of the structure and major functions for the new EMS in KEPCO. This system will be in operation in the beginning of the 21 century in compliance with power system expansion and system architecture consists of distributed and open computer technology. The transmission operation control center as a back-up control center of NCC will control under 345kV transmission system and regional control centers.

  • PDF

Robust and Reversible Image Watermarking Scheme Using Combined DCT-DWT-SVD Transforms

  • Bekkouch, Souad;Faraoun, Kamel Mohamed
    • Journal of Information Processing Systems
    • /
    • v.11 no.3
    • /
    • pp.406-420
    • /
    • 2015
  • We present a secure and robust image watermarking scheme that uses combined reversible DWT-DCT-SVD transformations to increase integrity, authentication, and confidentiality. The proposed scheme uses two different kinds of watermarking images: a reversible watermark, $W_1$, which is used for verification (ensuring integrity and authentication aspects); and a second one, $W_2$, which is defined by a logo image that provides confidentiality. Our proposed scheme is shown to be robust, while its performances are evaluated with respect to the peak signal-to-noise ratio (PSNR), signal-to-noise ratio (SNR), normalized cross-correlation (NCC), and running time. The robustness of the scheme is also evaluated against different attacks, including a compression attack and Salt & Pepper attack.

"Pansori" Joint Assumption using Neural Network (인공신경망을 이용한 판소리 마디추정)

  • Park, Keunho;Seo, Kyoung-suk;Lee, Joonwhoan
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2014.11a
    • /
    • pp.975-977
    • /
    • 2014
  • 본 논문에서는 판소리 자동채보에 중요한 요소인 '합'과 '궁'의 위치 즉 마디를 인공신경망과 히스토그램을 이용하여 추정한다. 기존의 합과 궁을 추정하는 방법으로는 NCC(Normalized Cross Correlation)를 이용한 대표치 추정 윈도우와 칼만 필터를 이용하였다. 하지만 대표치 추정 윈도우를 구성하는 과정에서 단순히 15개의 특징벡터 각각의 평균을 이용하기 때문에 분별력이 떨어지고, 마디위치를 보정하는 과정에서 칼만 필터를 사용하면 전체음원이 길이가 짧을 경우 오차가 발생할 가능성이 크다. 본 논문에서 제안한 마디 추정 알고리즘은 장단별로 최대 90%이상의 정확도로 마디를 추정할 수 있다.

An Iterated Optical Flow Estimation Method for Automatically Tracking and Positioning Homologous Points in Video Image Sequences

  • Tsay, Jaan-Rong;Lee, I-Chien
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.372-374
    • /
    • 2003
  • The optical flow theory can be utilized for automatically tracking and positioning homologous points in digital video (DV) image sequences. In this paper, the Lucas-Kanade optical flow estimation (LKOFE) method and the normalized cross-correlation (NCC) method are compared and analyzed using the DV image sequences acquired by our SONY DCRPC115 DV camera. Thus, an improved optical flow estimation procedure, called 'Iterated Optical Flow Estimation (IOFE)', is presented. Our test results show that the trackable range of 3${\sim}$4 pixels in the LKOFE procedure can be apparently enlarged to 30 pixels in the IOFE.

  • PDF

Fiducial mark alignment using distance transform (거리변환을 이용한 fiducial 마크 정렬 알고리즘)

  • Cui, Xue-Nan;Park, Eun-Soo;Choi, Hyo-Hoon;Kim, Hak-Il
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2010.06c
    • /
    • pp.442-446
    • /
    • 2010
  • 본 논문에서는 거리변환 기반의 정밀한 fiducial 마크 정렬 알고리즘을 제안한다. 거리변환은 물체의 중심에 가중치를 가지는 특성이 있는데 이는 AOI 공정에서 에칭, 이동과 같은 다양한 요소들로부터 획득되는 타겟영상에 대하여 강인하게 물체의 중심으로 매칭할 수 있도록 한다. 제안한 방법은 우선 입력 타겟영상에 대하여 이진화를 진행하고, 다음 모델과 타겟영상에 대하여 거리변환을 이용하여 거리특징을 추출하고, 추출된 모델과 타겟영상에 대한 거리특징을 NCC(Normalized Cross Correlation)를 이용하여 매칭한 후, 매칭 스코어에 대하여 Sub-pixel 분석을 진행하여 sub-pixel 레벨의 정확도를 가지도록 한다. 실험결과로부터 제안한 거리특징을 이용한 매칭 알고리즘이 기존의 픽셀 밝기 값을 이용한 매칭보다 강인하고 정확하게 매칭됨을 확인할 수 있었다.

  • PDF

Sensitivity of quantitative symmetry measurement algorithms for convergent beam electron diffraction technique

  • Hyeongsub So;Ro Woon Lee;Sung Taek Hong;Kyou-Hyun Kim
    • Applied Microscopy
    • /
    • v.51
    • /
    • pp.10.1-10.9
    • /
    • 2021
  • We investigate the sensitivity of symmetry quantification algorithms based on the profile R-factor (Rp) and the normalized cross-correlation (NCC) coefficient (γ). A DM (Digital Micrograph©) script embedded in the Gatan digital microscopy software is used to develop the symmetry quantification program. Using the Bloch method, a variety of CBED patterns are simulated and used to investigate the sensitivity of symmetry quantification algorithms. The quantification results show that two symmetry quantification coefficients are significantly sensitive to structural changes even for small strain values of < 1%.

KpqC 공모전에 제출된 Fiat-Shamir with aborts 구조의 격자 기반 서명 기법 분석

  • 홍가희;우주;박종환
    • Review of KIISC
    • /
    • v.33 no.3
    • /
    • pp.27-37
    • /
    • 2023
  • 양자 컴퓨팅의 발전으로 기존의 전자서명 기법에 사용되던 소인수분해 문제와 이산로그 문제가 다항 시간 내에 풀린다. 그에 따라 국내외에서는 양자 컴퓨팅 환경에서도 안전한 암호 기법에 대한 연구가 활발히 진행되고 있다. 미국 국립 표준 기술 연구소에서 양자 내성 암호 기법의 표준을 설립하고자 Post-Quantum Cryptography Standardization Process를 진행하였으며 전자서명 기법으로는 CRYSTALS-Dilithium, FALCON, SPHINCS+가 표준으로 선택되었다. 국내에서도 양자 내성 암호 표준 수립을 위하여 KpqC 공모전이 개최되었다. 본 논문에서는 KpqC 공모전 Round 1에 제안된 격자 기반 전자서명 기법 중 Dilithium과 같이 Fiat-Shamir with aborts paradigm 구조로 설계된 3개의 기법, HAETAE, GCKSign, NCC-Sign을 분석하고 Dilithium과 함께 비교하였다.

Shade Comparative Analysis of Natural tooth Measured by Visual and Two Colorimeters(ShadeEye®,Shadepilot®) (2종 측색기와 시각을 이용한 자연치아의 색조 비교 분석)

  • An, Jin-Hee;Choi, Mee-Ra;Shim, Hye-Won
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.1
    • /
    • pp.81-93
    • /
    • 2013
  • The objectives were to evaluate the accuracy of shade selection by human visual system(VS) and 2 different colorimeters ($ShadeEye^{(R)}$(SE) and Shadepilot (SP)). Maxillary anterior teeth of 30 volunteers which had no caries or restorations were included in the study. Firstly, the accordance in shade selection by 3 dentists and 2 colorimeters was investigated. Secondly, the color of the teeth were measured by 1 observer's naked eye and 2 colorimeters under different illumination conditions (Sunny versus cloudy day). Additionally testing of inter-observer variability selected colors by 2 novice and 2 experienced dentists were compared. For comparing visual and 2 different colorimeters, SP(60%) showed significantly highest rate of accordance than the visual (23.3%) or SE (16.7%) and lowest mean ${\Delta}E$ ($2.62{\pm}0.74$ versus $3.83{\pm}1.38$;SE or $4.04{\pm}1.61$;VS)(p<0.001). If accuracy of shade selection were measured using VS, the mean ${\Delta}E$ value of cloudy day was higher than that of sunny day ($4.35{\pm}1.70$ versus $3.53{\pm}1.31$; p<0.001). There were no significant difference of the mean ${\Delta}E$ value between sunny and cloudy day in both SE and SP. Inter- observer repeatability was higher in 2 experienced group (73.3%) than novice group (36.7%). The mean ${\Delta}E$ of experienced group was lower than that of novice group ($3.60{\pm}1.47$ versus $4.70{\pm}1.67$; p<0.001). Colorimeters (SE or SP) is more accurate and more reproducible compared with human shade assessment. Using visual system may be limited by cloudy and inexperience of tester, then more experience and using colorimeters may be helpful of raising the accurate repeatability of shade selection.

A STUDY ON THE COLORS OF THE ANTERIOR PRIMARY RESIN TEETH (유치레진치의 전치부 색조연구)

  • Hyun, Hong-Keun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.4
    • /
    • pp.639-645
    • /
    • 2007
  • Removable or fixed space maintainer could be needed if one or some anterior primary teeth were missing, where resin pontics well-matched to natural primary teeth should be demanded to get an esthetic satisfaction. Resin Natural $Teeth^{TM}$(Nissin dental, Japan) is available currently in Korea, which consists of two shades of colors; type A1 and A2. The purpose of this study is to elucidate the colors of the anterior primary resin teeth and to establish the data to compare those with the natural anterior primary teeth. CIE $L^*a^*b^*s$ were measured each three times labially from 17 sets of maxillary four anterior teeth for type A1 and A2 Resin Natural $Teeth^{TM}$ using ShadeEye $NCC^{TM}$(Shofu, Japan) which is one of spectrophotometers. The data were analysed statistically using Kruskall-Wallis Test and Mann-Whitney U Test. The results were as follows : 1. There were smaller teeth color differences in group A1 than in group A2 when it comes to distributions of ${\Delta}E$, $L^*$ and $b^*$. There were no statistically significant differences of $a^*$ between teeth in the same group(P>0.05). 2. ${\Delta}E$ in group A1 and A2 (maximum ${\Delta}E{\le}1.23$) were very small, which could not be discerned by eyesight. ${\Delta}E$ between mean CIE $L^*a^*b^*s$ of group A1 and A2 was 3.97, which could be discernible by eyesight. 3. Mean measurements of group A1 were $L^*=73.8$, $a^*=-1.8$, $b^*=-4.7$, and those of group A2 were $L^*=75.8$, $a^*=-2.7$, $b^*=-1.4$. It would be recommended that resin teeth compatible to the colors of the natural primary ones needed to be developed by investigating in vivo study.

  • PDF