• 제목/요약/키워드: N.D.C method

검색결과 794건 처리시간 0.05초

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

현장시험 및 수치해석을 통한 확공지압형 앵커의 거동특성 (Behavior Characteristics of Underreamed Ground Anchor through Field Test and Numerical Analysis)

  • 김계웅;안광국;민경남;정찬묵
    • 한국지반환경공학회 논문집
    • /
    • 제14권8호
    • /
    • pp.37-44
    • /
    • 2013
  • 지압형 앵커는 일본, 유럽 등에서 1950년대부터 안정성 및 경제성의 우수함이 인식되어 왔다. 하지만 국내에서 적용하고 있는 지압형 앵커는 쐐기체의 확장에 의한 지반의 마찰력만으로 설계 인장력을 발휘하는 구조적인 문제점을 지니고 있으며 공벽에 밀착시키는 방법이 마땅치 않아 지압력을 확인하기가 어려운 실정이다. 본 연구에서는 지압력을 최대한 발휘할 수 있도록 확공지압형 앵커시스템을 개발하였다. 또한, 확공지압형 앵커의 인발특성을 평가하고 지압력에 의한 정착장 감소효과를 검증하기 위하여 현장시험을 수행하였다. 확공지압형 앵커에 대한 현장시험은 그라우팅 이전 가인장 상태와 그라우팅 후 본인장 상태에 대한 인발시험을 각각 수행하여 인발저항력을 확인하였으며 이를 마찰형 앵커의 인발시험 결과와 비교 분석하였고, 범용 유한요소해석 프로그램인 PLAXIS-2D를 이용한 정착부 상세 모델링을 통하여 가인장 시 정착부에서의 지압효과에 대한 검증을 수행하였다.

체외순환 시 뇌대사에 대한 정상 탄산분압과 고 탄산분압의 임상적 영향에 관한 비교연구 (The Clinical Effects of Normocapnia and Hypercapnia on Cerebral Oxygen Metabolism in Cardiopulmonary Bypass)

  • 김성룡;최석철;최국렬;박상섭;최강주;윤영철;전희재;이양행;황윤호
    • Journal of Chest Surgery
    • /
    • 제35권10호
    • /
    • pp.712-723
    • /
    • 2002
  • 체외순환은 뇌 혈류의 변화를 유도하며 이러한 변화가 수술 후 직 간접적인 뇌 손상의 원인이 될 수도 있다. 최근 체외순환 중 뇌 혈류 변화는 동맥혈액의 이산화탄소 분압과 밀접한 관련이 있는 것으로 보고되고 있다. 본 연구는 체외순환을 이용한 심장수술시 뇌 대사에 대한 정상 탄산분압과 고 탄산분압의 임상적 영향을 비교 조사하기 위해 전향적으로 계획되었다. 대상 및 방법: 심장수술이 계획된 36명의 성인 환자들을 연구목적에 따라 무작위적으로 정상탄산분압군(Pa$CO_2$35~40 mmHg, n=18) 혹은 고탄산분압군(Pa$CO_2$45~55 mmHg, n=18)으로 나눈 뒤 중등도 저체온(비인두 온도 29~3$0^{\circ}C$)의 비박동성 체외순환을 실시하였다. 수술 중, 각 환자들의 중대뇌동맥 혈류속도(뇌혈류 속도), 뇌동정맥 산소함량 차, 뇌산소 추출률, 뇌산소 대사율, 뇌산소 운반율, 뇌산소운반/뇌산소대사 비율, 뇌정맥 산소 불포화도(내경 정맥구 혈액 산소 포화도$\leq$50%), 동맥혈액 및 내경정맥 혈액 가스분석 등을 평가하였고, 수술 후 신경학적 합병증(섬망증세) 발생 정도 역시 관찰하여 양 그룹간에 비교하였다. 결과 : 체외순환 동안 고탄산분압군이 정상탄산분압군에 비해 뇌혈류 속도(169.13 $\pm$ 8.32 vs 153.11 $\pm$8.98%), 뇌산소 운반율(1,911.17$\pm$250.14 vs 1,757.40$\pm$249.56), 뇌산소운반/뇌산소대사 비율(287.38$\pm$28.051 vs 246.77$\pm$25.84), 내경 정맥구 산소분압(41.66$\pm$9.19 vs 31.50$\pm$6.09 mmHg), 그리고 내경 정맥구 산소포화도(68.97$\pm$10.96 vs 58.12$\pm$12.11%) 등이 유의하게 더 높았으나 (p=0.03), 뇌동정맥 산소함량차(3.9$\pm$0.3 vs 4.9$\pm$0.3 mL/dL), 뇌산소 추출률(0.3$\pm$0.03 vs 0.4$\pm$0.03), 뇌산소 대사율(5.8 $\pm$0.5 vs 6.8$\pm$0.6), 동맥혈 pH는 고탄산분압군이 더 낮았다(7.36$\pm$0.09 vs 7.46$\pm$0.07, p=0.04). 체외순환 동안 뇌정맥혈 불포화를 보인 환자 수는 고탄산분압군이 정상탄산분압군 보다 유의하게 더 적었다(3명 vs 9명, p=0.03). 수술 후 신경학적 합병증(섬망)의 지속시간 역시 고탄산분압군이 정상탄산분압군 보다 더팔았다(36시간 vs 60시간, p=0.009). 결론: 이상의 연구결과들은 심장수술 동안 고탄산분압 체외순환이 뇌대사 및 수술 후 신경학적 결과에 보다 유익한 효과를 제공해 줄 수 있음을 시사하고 있다.

Test of Insecticidal Efficacy of Some Commercial Natural Products against Trialeurodes vaporariorum(Homoptera : Aleyrodidae), Bemisia tabaci(Homoptera : Aleyrodidae), and Spodoptera litura(Lepidoptera : Noctuidae)

  • Jeong, Hyung-Uk;Kim, Man-Il;Chang, Sung-Kwon;Oh, Hyung-Keun;Kim, Ik-Soo
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • 제18권2호
    • /
    • pp.105-112
    • /
    • 2009
  • The greenhouse whitefly, Trialeurodes vaporariorum (Westwood) and the sweet potato whitefly, Bemisia tabaci (Gennadius) are serious insect pests that have a wide host range including cucumber, tomato, and pepper. In this study, we tested larvicidal efficacy of several on-the-market environment-friendly agricultural materials (EFAM) to select the effective products after the target pests were stabilized in indoor rearing condition. The developmental periods of two whiteflies are as follows: in the case of T. vaporariorum, egg duration is 9.6 days and nymph is 18.9 days, and in the case of B. tabaci, egg duration is 7.4 days and nymph is 15.2 days under $25^{\circ}C$ with relative humidity (RH) of $60{\pm}5%$ and a photoperiod of 16 L:8D. The total period of T. vaporariorum was 5 days longer than B. tabaci. Among 22 EFAMs six products showed more than 60% of insecticide efficacy against T. vaporariorum BTV B, BTV D, BTV G, BTV L, BTV M, and BTV S. On the other hand, seven EFAM products showed over 60% of insecticide efficacy against B. tabaci BTV D, BTV G, BTV K, BTV L, BTV M, BTV N, and BTV U. In the case of Spodptera litura previously, 16 EFAMs were tested against $2^{nd}$ instar S. litura, and six EFAMs were found to have more than 90% efficacy. Test of these six EFAMs against entire larval stages were performed in this study. Although some of these products showed still more than 90% of insecticidal efficacy against up to $3^{rd}$ instar larvae, the efficacy of these EFAMs sharply decreased as ages increase, resulting in less than 60% of efficacy of the products at most. This result indicates the difficulty to control S. litura with the on-the-market EFAMs alone under economic injury level. Collectively, it is required to find more EFAMs, and find alternative method, and combined way of controlling to control those insect pests tested in this study.

부위 및 조리방법에 따른 가지의 Glycoalkaloid와 Ascorbic Acid 함량 변화 (The Changes on Ascorbic Acid and Glycoalkaloid Contents of Eggplant by Parts and Cooking Methods)

  • 소궤신행;한재숙;최수근;변광인;서봉순;최석현;박미란
    • 한국조리학회지
    • /
    • 제12권4호
    • /
    • pp.247-258
    • /
    • 2006
  • 최근 건강에 대한 관심이 고조되고 있는 시점에서, 항암작용 등의 기능성을 지닌 가지의 부위별, 조리 방법에 따른 glycoalkaloid와 ascorbic acid의 함량을 측정한 결과는 다음과 같다. 1. 가지의 부위별 glycoalkaloid의 함량은 solamargine의 함량은 꼭지부분인 (A)가 $35{\mu}g$으로 가장 많았고, Solasonine의 함량 또한 (A)가 $31.1{\mu}g$으로 가장 많은 것으로 나타났다. 2. 조리 방법에 따른 가지의 solamargine, solasonine의 함량 변화는 조리전의 가지, 즉 대조군의 solamargine 함량은 $11.4{\mu}g$이었으며, solasonine은 $4.88{\mu}g$으로 solasonine에 비하여 solamargine의 함량이 현저히 많은 것으로 나타났다. 또한 조리 후 가지의 solamargine의 함량은 boiling이 $7.0{\mu}g$으로 가장 많았고 microwave 처리는 $2.0{\mu}g$로 가장 적었다. Solasonine의 함량은 steaming이 $3.4{\mu}g$으로 가장 많은 것으로 나타났다. 3. 시판 가지의 부위별 ascorbic acid 함량은 꼭지부분인 (A)가 가장 많은 $2.31{\mu}g$이었고, 다음은 중간부분인 (B), 끝부분인 (C)순이었다. 즉, 꼭지에서 아래로 내려갈수록 ascorbic acid의 함량은 감소하였다. 4. 조리 방법별 가지의 ascorbic acid의 함량은 다른 채소류와 마찬가지로 조리조작에 의하여 크게 감소하였는데, 잔존량은 control(before cooking) > sauteing > microwave > boiling > steaming의 순이었다.

  • PDF

OMC Nano-emulsion을 포집하고 있는 Nano-TiO$_2$-Paste의 합성과 화장품의 응용 (Inorganic-organic nano-hybrid; Preparation of Nano-sized TiO$_2$ Paste Trapped OMC Nano-emulsion and it's Application for Cosmetics)

  • Byung Gyu, Park;Jong Heon, Kim;Jin Hee, Im;Kyoung Chul, Lee
    • 대한화장품학회지
    • /
    • 제30권2호
    • /
    • pp.181-187
    • /
    • 2004
  • 화장품에서 유기 화합물인 OMC(octyl methoxy cinnamate)와 무기 소재인 TiO$_2$가 자외선 차단제로 가장 보편적으로 사용되고 있다. 그러나 OMC는 skin trouble이 있고, TiO$_2$는 첨가량에 비해서 자외선 차단 효율이 OMC보다 낮고 입자의 크기효과에 의해 백탁 현상이 나타나는 단점이 있다. 본 연구에서는 이러한 두 성분이 갖는 단점을 보완하는 방법으로 OMC를 나노에멀젼시키고, 이 나노에멀젼-OMC를 나노-TiO$_2$ 미립자로 포접하여 자외선 차단효과를 극대화 하면서, 피부에 OMC가 직접적으로 적용하지 못하도록 하는 방법을 연구하였다. 특히 계면활성제를 boundary로 하는 유기/무기 hybrid nano-material에서 TiO$_2$ 미립자와 OMC-에멀젼이 나노 크기가 되면 백탁 현상이 나타나지 않는 투명한 화장품을 제조할 수 있을 뿐만 아니라 나노-에멀젼 OMC를 TiO$_2$로 포집하는 과정에서 hydrophilic character를 갖는 레시친으로 TiO$_2$를 안정화하여 보습성을 더욱 향상시켰다. 합성한 inorganic-organic hybrid nano-material는 TEM을 이용하여 나노 미립자의 morphologies를 규명하였고, UV-Visible spectrometer를 이용하여 자외선 흡수를 측정하였다. 또한 X-ray diffractometer를 이용하여 나노-에멀젼 OMC를 포집하고 있는 TiO$_2$ 미립자가 갖는 특성인 pore의 크기와 구조를 측정하였다. 화장품적인 응용으로서 SPF analyzer 측정결과 기존의 powder-OMC에 비하여 우수한 자외선 차단 효과를 나타내었으며, OMC의 피부 침투도 훨씬 줄일 수 있어 OMC의 피부 부작용을 크게 줄일 수 있을 것이다.>$\pm$0.06 $\mu$g/g 범위였다. 4. 날결명자 분말첨가군 각 조직에 축적된 카드뮴 함량이 제일 낮았던 C4를 Cl과 비교한 결과 뇌, 심장, 비장, 간, 폐, 고환, 신장, 대퇴부근육, 다리뼈에 각각 49.03, 22.56, 36.02, 35.75, 41.75, 36.20, 37.00, 22.77, 56.67 %의 감소를 보였으며, 각 장기의 함량은 뇌<다리뼈<대퇴부 근육<고환<폐<심장<비장<신장<간 순 이었다. 5. 카드뮴 총 섭취량으로 장기 및 조직의 카드뮴 평균함량에 대한 축적율은 카드뮴만 섭취한 군(Cl) 의 경우 7.14%이었으며, 결명자 분말 첨가군인 C2, C3, C4군의 경우 각각 4.91, 4.81, 4.50 %이었다. 6. 체모의 카드뮴 함량은 Cl군이 가장 높았고, 결명자 첨가군들의 카드뮴 함량은 6주째까지 모든 시험군에서 증가하는 경향을 보였으며, 6주 이후에는 감소되는 경향을 보였다. 7. 분변 중 카드뮴 함량은 C4군이 가장 높았고, 결명자 첨가군들의 카드뮴 함량은 C3군과 C4군을 제외한 나머지 군들에서 완만하게 증가하는 경향을 보였으며, 6주째에 카드뮴 함량이 감소되는 경향을 보였다가 6주 이후에 다시 카드뮴 함량이 증가하는 경향이었다.erefore the guidelines for iron supplementation and nutritional education to improve their iron status should be provided.한 질소제거를 N-balance로부터 구해보면, R3 반응조의 경우가 가장 높은 제거율(40.9%)을 보였다. 이상의 결과들을 볼 때, Bncillus 균주는 호기적 탈질을 일으킬 수 있는 가능성이 있고, Bncillus 균주를 이용한 B3 공정은 탈질에 이용되는 탄소량이 거의 없고, 적은 alkalinity 소모에 의한 경제적 이익 등 장점을 가진 공정으로 보여 진다.수록 푹신한 감이 있는

열간 자유단조 공정시 내부 기공 압착 거동에 관한 해석 (FE-Analysis on void closure behavior during hot open die forging process)

  • 권용철;이정환;이승욱;정용수;김남수;이영선
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2007년도 춘계학술대회 논문집
    • /
    • pp.160-164
    • /
    • 2007
  • In the steel industry, there is a need to produce large forged parts for the automobile industries, the flight and shipping industries ad military industries. In the steel-industry application, a cogging technique for cast ingots is required, because the major parts are needed as one large body in order to obtain higher quality. Therefore, cogging process is the primary step in manufacturing of practically large open-die forging. In the cogging process, internal voids have to be eliminated as defects, The present work is concerned with the elimination of the internal voids in large ingots so as obtain sound products. In this study, hot compression tests were carried out to obtain the flow stress of cast microstructure at different temperature and strain rates. The FEM analysis are performed to investigate the overlap defect of cast ingots during cogging stage. The measure flow stress data were used to simulate the cogging process of cast ingot using the practical material properties. Also the analysis of void closure are performed by using the $DEFORM^{TM}$-3D. The calculated results of void closure behavior are compared with the measured results before and after cogging, which are scanned by the X-ray scanner. From this result, the criteria for deformation amounts effect on the void closure can be investigated by the comparison of practical experiment and numerical analysis.

  • PDF

Retrofit strategy issues for structures under earthquake loading using sensitivity-optimization procedures

  • Manolis, G.D.;Panagiotopoulos, C.G.;Paraskevopoulos, E.A.;Karaoulanis, F.E.;Vadaloukas, G.N.;Papachristidis, A.G.
    • Earthquakes and Structures
    • /
    • 제1권1호
    • /
    • pp.109-127
    • /
    • 2010
  • This work aims at introducing structural sensitivity analysis capabilities into existing commercial finite element software codes for the purpose of mapping retrofit strategies for a broad group of structures including heritage-type buildings. More specifically, the first stage sensitivity analysis is implemented for the standard deterministic environment, followed by stochastic structural sensitivity analysis defined for the probabilistic environment in a subsequent, second phase. It is believed that this new generation of software that will be released by the industrial partner will address the needs of a rapidly developing specialty within the engineering design profession, namely commercial retrofit and rehabilitation activities. In congested urban areas, these activities are carried out in reference to a certain percentage of the contemporary building stock that can no longer be demolished to give room for new construction because of economical, historical or cultural reasons. Furthermore, such analysis tools are becoming essential in reference to a new generation of national codes that spell out in detail how retrofit strategies ought to be implemented. More specifically, our work focuses on identifying the minimum-cost intervention on a given structure undergoing retrofit. Finally, an additional factor that arises in earthquake-prone regions across the world is the random nature of seismic activity that further complicates the task of determining the dynamic overstress that is being induced in the building stock and the additional demands placed on the supporting structural system.

Panax ginseng-derived fraction BIOGF1K reduces atopic dermatitis responses via suppression of mitogen-activated protein kinase signaling pathway

  • Lorz, Laura Rojas;Kim, Donghyun;Kim, Mi-Yeon;Cho, Jae Youl
    • Journal of Ginseng Research
    • /
    • 제44권3호
    • /
    • pp.453-460
    • /
    • 2020
  • Background: BIOGF1K, a fraction of Panax ginseng, has desirable antimelanogenic, anti-inflammatory, and antiphotoaging properties that could be useful for treating skin conditions. Because its potential positive effects on allergic reactions in skin have not yet been described in detail, this study's main objective was to determine its efficacy in the treatment of atopic dermatitis (AD). Methods: High-performance liquid chromatography was used to verify the compounds in BIOGF1K, and we used the (3-4-5-dimethylthiazol-2-yl)-2-5-diphenyltetrazolium bromide method to determine its cytotoxicity in RBL-2H3 and HMC-1 cell lines. RBL-2H3 cells were induced using both anti-DNP-IgE/DNP-BSA and calcium ionophore (A2187) treatments, whereas HMC-1 cells were induced using A2187 alone. To measure mast cell degranulation, we performed histamine (enzyme-linked immunosorbent assay) and β-hexosaminidase assays. To quantify interleukin (IL)-4, IL-5, and IL-13 levels in RBL-2H3 cells, we performed quantitative polymerase chain reaction (PCR); to quantify expression levels of IL-4 and IL-13 in HMC-1 cells, we used semiquantitative reverse transcription polymerase chain reaction (RT-PCR). Finally, we detected the total and phosphorylated forms of extracellular signal-regulated kinase, p-38, and c-Jun N-terminal kinase proteins by immunoblotting. Results: BIOGF1K decreased the AD response by reducing both histamine and β-hexosaminidase release as well as reducing the secretion levels of IL-4, IL-5, and IL-13 in RBL-2H3 cells and IL-4 and IL-13 in HMC-1 cells. In addition, BIOGF1K decreased MAPK pathway activation in RBL-2H3 and HMC-1 cells. Conclusions: BIOGF1K attenuated the AD response, hence supporting its use as a promising and natural approach for treating AD.

선미관 밀봉장치 개발에 관한 연구 (I) - 맆 시일을 중심으로- (A Study on the Development of Ship's Stern Tube Sealing System(I) -Based on Lip Seals-)

  • 김영식;전효중;왕지석;정재현
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제15권4호
    • /
    • pp.29-45
    • /
    • 1991
  • Lip type stern tube sealing systems have used in almost all the middle or large ships which are being constructed in these days. It seems that the pressure fluctuation of the seal ring interspace, the cross-section profile and the materials quality of the seal rings have great effects on the sealing fuction of this sealing system. In this paper, the mechanical movement of lip seal ring which plays the most important role in stern tube sealing system and the possibility of leakage caused by pressure fluctuation are studied by theory and experiment. Using the finite element method for the axi-symetric object which receives the torsional load, the displacement and stress analysis of the seal rings, and also the possibility of crack occurance is checked by theoretical analysis. If the force which seal ring lip periphery receives is too small, there will be the possibility of leakage caused by the pressure fluctuation of the seal ring interspace, and if this force is too large, the frictional force between the seal ring and the liner will become problematical. The possibility of leakage caused by hardening of seal ring materials and creep phenomena of tested seal rings are also examined. The trial seal rings were designed and manufactured using the program of displacement and stress analysis developed in this study and the experimental apparatus to test the trial seal rings was also designed and manufactured. This trial seal rings were fitted in the experimental apparatus which was made in the same form as an actual stern tube. The one side of this apparatus was filled with sea water and the other side of it was filled with the lubricating oil. The leakage of oil and sea water was checked and the temperature was measured, rotating the propeller shaft at the constant velocity by D.C. motor. It was proved that the trial seal rings made in Viton rubber functioned excellenty but the trial seal rings made in N.B.R. rubber had problem in its durability.

  • PDF