Abstract
The superiority of bearing ground anchor system has been recognized for the stability and economical efficiency since 1950s in Japan, Europe and etc. The ground anchor introduced in Korea, however, has the structural problem that the tensile strength comes only from the ground frictional force caused by the expansion of the wedge body and it is impossible to evaluate the bearing resistance because the adhering method of the anchor body to hollow wall is not appropriate. In this study, the underreamed ground anchor system was developed so that the bearing pressure of ground anchor can exert as much as possible. And the in-situ tests were performed to evaluate the pullout behavior characteristics and to verify the decreasing effect of the bonded length. The pullout tests were performed with the non-grouted tension condition and grouted tension condition in order to identify the pull-out resistance of each conditions. In addition, it was compared with the results of friction anchor. Finally, the numerical analysis was fulfilled to verify the bearing effect at the bonded part through the detailed modeling by PLAXIS-2D, which is general finite element method analysis program.
Keywords
Underreamed; Bearing ground anchor; Pullout test; Numerical analysis;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Kim, N. K., Kim, S. K., Joo, Y. S., Seo, H. K. and Kim, S. J.(2009), Expansion ratio and ultimate load of pulse-discharge bulbed anchors, Journal of the Korean Geotechnical Society, Vol. 25, No. 7, pp. 5-10 (in Korean).
2 Kim, T. S., Sim, B. K., Lee, K. S. and Lee, I. M.(2010), The effect of pressurized grouting on pullout resistance and the group effect of compression ground anchor, Journal of the Korean Geotechnical Society, Vol. 26, No. 6, pp. 5-19 (in Korean).
3 Lee, B. J., Kim, J. S. and Lee, J. K.(2012), Pullout characteristics of MC anchor in shale layer, Journal of the Korean Geo-Environmental Society, Vol. 13, No. 1, pp. 53-61 (in Korean).
4 Min, K. N., Ahn, K. K., Lee, J. B., Park, H. J., Lee, J. W. and Lee, J. K.(2010), The applicability evaluation on the ground type anchor with field test, The Korean Society of Engineering Geology 2010 Autumn Conference, pp. 59-63 (in Korean).
5 Ostermayer. H.(1975), Construction, carrying behavior and creep characteristics of ground anchors, Diaphragm walls & anchorages, ICE, London, pp. 141-151.
6 Shin, Y. S.(1998), Up-to-date topics in landslide engineering, Won Gi Sul, pp. 528 (in Korean).