• Title/Summary/Keyword: N-fixation

검색결과 312건 처리시간 0.035초

Biomechanical analysis of pullout strength of the pedicle screws in relation to change bone mineral density (반복 하중 후 골밀도 감소에 따른 척추경 나사못의 고정력(Pullout Strength)감소 형태 분석)

  • Jung, D.Y.;Lee, S.J.;Kim, D.S.;Shin, J.W.;Kim, W.J.;Suk, S.I.
    • Proceedings of the KOSOMBE Conference
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.155-156
    • /
    • 1998
  • Screw loosening and subsequent pullout can be attributed to the reduction in bone mineral density in the vertebrae manifested by osteoporosis in which the decrease in fixation strength between the cancellous bone and screw threads are accelerated by repeated loads exerted by patients own weight and activities following the surgery. In this study, the change in pullout strength of the pedicle screws was investigated before and after repeated loads were imparted. For this purpose. Diapason pedicle screws $(6.7\times40mm)$ were inserted onto fresh porcine spine specimens (T1-L5) after bone mineral density was measured using a DEXA. With an MTS, an axial load was applied at a loading rate of 0.33mm/sec until failure to measure the maximum pullout strength. Flexion moment of 7.5N-m was then imparted at 0.5Hz for 2000 cycles. It was found that the maximum pullout strength was exponentially related to BMD regardless of load types ($107.71\;\times\;\exp^{(1.43{\times}BMD)}r^2=0.93$, P<0.0001 without repeated load; ($107.71\;\times\;\exp^{(2.19{\times}BMD)}r^2=0.78$, P<0.0001 with repeated load). The results suggest that the reduction in pullout strength for pedicle screws is far more prominent in osteoporotic spine than in normal spine especially as number of repeated load was increased. More importantly, it was demonstrated that the level of bone mineral density and the activity level of the patient should be evaluated in more detail for successful implementation of pedicle screw systems in spinal surgery.

  • PDF

The Hypernodulating nts Mutation Induces Jasmonate Synthetic Pathway in Soybean Leaves

  • Seo, Hak Soo;Li, Jinjie;Lee, Sun-Young;Yu, Jae-Woong;Kim, Kil-Hyun;Lee, Suk-Ha;Lee, In-Jung;Paek, Nam-Chon
    • Molecules and Cells
    • /
    • 제24권2호
    • /
    • pp.185-193
    • /
    • 2007
  • Symbiotic nitrogen fixation with nitrogen-fixing bacteria in the root nodules is a distinctly beneficial metabolic process in legume plants. Legumes control the nodule number and nodulation zone through a systemic negative regulatory system between shoot and root. Mutation in the soybean NTS gene encoding GmNARK, a CLAVATA1-like serine/threonine receptor-like kinase, causes excessive nodule development called hypernodulation. To examine the effect of nts mutation on the gene expression profile in the leaves, suppression subtractive hybridization was performed with the trifoliate leaves of nts mutant 'SS2-2' and the wild-type (WT) parent 'Sinpaldalkong2', and 75 EST clones that were highly expressed in the leaves of the SS2-2 mutant were identified. Interestingly, the expression of jasmonate (JA)-responsive genes such as vspA, vspB, and Lox2 were upregulated, whereas that of a salicylate-responsive gene PR1a was suppressed in the SS2-2 mutant. In addition, the level of JA was about two-fold higher in the leaves of the SS2-2 mutant than in those of the WT under natural growth conditions. Moreover, the JA-responsive gene expression persists in the leaves of SS2-2 mutant without rhizobia infection in the roots. Taken together, our results suggest that the nts mutation increases JA synthesis in mature leaves and consequently leads to constitutive expression of JA-responsive genes which is irrelevant to hypernodulation in the root.

Growth and Cyanide Degradation of Azotobacter vinelandii in Cyanide-Containing Wastewater System

  • Koksunan, Sarawut;Vichitphan, Sukanda;Laopaiboon, Lakkana;Vichitphan, Kanit;Han, Jaehong
    • Journal of Microbiology and Biotechnology
    • /
    • 제23권4호
    • /
    • pp.572-578
    • /
    • 2013
  • Azotobacter vinelandii, a strict aerobic nitrogen-fixing bacterium, has been extensively studied with regard to the ability of $N_2$-fixation due to its high expression of nitrogenase and fast growth. Because nitrogenase can also reduce cyanide to ammonia and methane, cyanide degradation by A. vinelandii has been studied for the application in the bioremediation of cyanide-contaminated wastewater. Cyanide degradation by A. vinelandii in NFS (nitrogen-free sucrose) medium was examined in terms of cell growth and cyanide reduction, and the results were applied for cyanide-contaminated cassava mill wastewater. From the NFS medium study in the 300 ml flask, it was found that A. vinelandii in the early stationary growth phase could reduce cyanide more rapidly than the cells in the exponential growth phase, and 84.4% of cyanide was degraded in 66 h incubation upon addition of 3.0 mM of NaCN. The resting cells of A. vinelandii could also reduce cyanide concentration by 90.4% with 3.0 mM of NaCN in the large-scale (3 L) fermentation with the same incubation time. Finally, the optimized conditions were applied to the cassava mill wastewater bioremediation, and A. vinelandii was able to reduce the cyanide concentration by 69.7% after 66 h in the cassava mill wastewater containing 4.0 mM of NaCN in the 3 L fermenter. Related to cyanide degradation in the cassava mill wastewater, nitrogenase was the responsible enzyme, which was confirmed by methane production. These findings would be helpful to design a practical bioremediation system for the treatment of cyanide-contaminated wastewater.

Surface Tribology of Total Ankle Joint Replacement (인공발목관절의 표면 마모 특성)

  • Jeong, Yong-Hoon;Jung, Tae-Gon;Yang, Jae-Woong;Park, Kwang-Min;Lee, Su-Won
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 한국표면공학회 2016년도 추계학술대회 논문집
    • /
    • pp.117-117
    • /
    • 2016
  • Total ankle replacement (TAR) is a visible option in the surgical treatment of degenerative or inflammatory diseases of ankle joint. it is attributed to the current TAR which has improvements in surgical technique, uncemented implant fixation and minimally constrained articulation. In the clinical result, they can show promised surgical result when compared to earlier attempts in TAR. However, TAR is still not as successful as total knee replacement (TKR) or total hip replacement (THR), it needs to be note that there are limitations in concerning of long term performance of TAR, the high failure rate still associated with wear of the PE (polyethylene) component that has related with their material property and surface roughness. The aim of this study was to introduce the tribology characteristics of total ankle joint prosthesis with one of TDR model which was fabricated to try multi-axis wear test as a region of motion in ankle joint. The wear specimen of TDR was prepared with Ti-6Al-4V alloy and UHMWPE (ultra-high molecular weight polyethylene) for tibia-talus and bearing component, respectively. A wear test was carried out using a Force 5 (AMTI, Massachusetts, US) wear simulator which can be allowed to move in three axis to flexion-extension ($+3^{\circ}{\sim}-6^{\circ}$), internal-external axial rotation (${\pm}5^{\circ}$), as well as sinusoidal compressive load (1.6 kN, R=10). All tests were performed following standard ISO 14243, wear rate was calculated with weight loss of UHMWPE bearing while the specimen has tested at certain cycles. As based on the preliminary results, wear rate of UHMWPE bearing was $7.9{\times}10^{-6}mg/cycles$ ($R^2=0.86$), calculated loss weight until $10^7cycles$ was 79 mg, respectively.

  • PDF

In-vitro development of a temporal abutment screw to protect osseointegration in immediate loaded implants

  • Garcia-Roncero, Herminio;Caballe-Serrano, Jordi;Cano-Batalla, Jordi;Cabratosa-Termes, Josep;Figueras-Alvarez, Oscar
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권2호
    • /
    • pp.160-165
    • /
    • 2015
  • PURPOSE. In this study, a temporal abutment fixation screw, designed to fracture in a controlled way upon application of an occlusal force sufficient to produce critical micromotion was developed. The purpose of the screw was to protect the osseointegration of immediate loaded single implants. MATERIALS AND METHODS. Seven different screw prototypes were examined by fixing titanium abutments to 112 Mozo-Grau external hexagon implants (MG Osseous$^{(R)}$; Mozo-Grau, S.A., Valladolid, Spain). Fracture strength was tested at $30^{\circ}$ in two subgroups per screw: one under dynamic loading and the other without prior dynamic loading. Dynamic loading was performed in a single-axis chewing simulator using 150,000 load cycles at 50 N. After normal distribution of obtained data was verified by Kolmogorov-Smirnov test, fracture resistance between samples submitted and not submitted to dynamic loading was compared by the use of Student's t-test. Comparison of fracture resistance among different screw designs was performed by the use of one-way analysis of variance. Confidence interval was set at 95%. RESULTS. Fractures occurred in all screws, allowing easy retrieval. Screw Prototypes 2, 5 and 6 failed during dynamic loading and exhibited statistically significant differences from the other prototypes. CONCLUSION. Prototypes 2, 5 and 6 may offer a useful protective mechanism during occlusal overload in immediate loaded implants.

Study on the meaning of Architectural Growth in Carlos Jim$\acute{e}$nez's "House and Studio" (카를로스 히메네즈의 'House and Studio'에 보이는 생장성(生長性)의 지역적 의미에 관한 연구)

  • Ahn, Joon-Suk
    • Journal of the Korean Institute of Rural Architecture
    • /
    • 제14권2호
    • /
    • pp.11-18
    • /
    • 2012
  • Carlos Jimenez's 'House and Studio' was self-designed to fully function as both a home and workplace. Since its establishment in 1983, the installation has been continuously updated for almost 30 years solely under the guidance of the owner's life occurrences and routine needs. The additions and alterations succeeding the building's erection were executed to incorporate small yet symbolic fragments of the resident's memories and life episodes. The particularity of the 'House and Studio' can be compared with other residential remodeling and expansion projects in regards to certain key aspects. These means of comparison include, but are not limited to, building strictly under the direction of a master plan of development vs. allowing natural adaptations that comply with the resident's needs, rapid development vs. gradual advancement, the ornamenting by exposing showy features vs. the enhancing by addition of modest natural components, sustainability vs. sustenance, systematic room divisions vs. ambiguous spatial organization, possession as a materialized asset vs. preservation as a recollection of memories, and finally the recognition as one example of signature architecture vs. the witnessing of a maturing animated shelter. The given propositions can be further explained with the comprehension of Erich Fromm's theory of the 'Having' mode and 'Being' mode, two mechanisms that categorize the essence of human life. The 'Having' mode is described by the human greed for wealth, power, and influence, whereas the 'Being' mode is comprised of compassion, joy, and productivity. Fromm's thesis applies to the general sense of human life, but the ideas can be narrowed to accommodate the architectural standpoint. In architecture, the 'Having' mode can be translated to be the conspicuous form-oriented and self-contained object. The 'Being' mode, on the other hand, is transposed as the more natural form, incorporating the needs of the owner before commercialization. The growth of Jimenez's 'House and Studio' can be perceived as an architectural suggestion to the overcoming of human indifference caused by fixation on the 'Having' mode.

Analysis of Biomechanical Responses for the Anterior Cervical Plate Fixation in relation to Bone Mineral Density (골밀도에 따른 전방 내고정 장치 시술 후 경추부의 생체역학적 거동에 대한 분석)

  • Shin, T. J.;Lee, S. J.;Shin, J. W.;Chang, H.
    • Journal of Biomedical Engineering Research
    • /
    • 제22권1호
    • /
    • pp.69-80
    • /
    • 2001
  • 본 연구에서는 환자의 골다공증 유무에 따른 내고정 장치 시술 직후 및 융합 후의 안정성을 평가하기 위해 다양한 하중 모드에서 C5-C6 운동분절의 생체역학적 거동을 분석하였다. 이러한 목적으로 먼저, C5-C6 경추부의 유한요소 모델을 구현하여 검증하였다. 모델의 결과는 기존 실험치와 유사하여 신뢰성이 부여되었다. 검증된 모델은 Smith-Robinson 방식으로 골이식물을 삽입한 후 전방 내고정 장치를 적용한 시술 상황을 재현하기 위해 수정되었다. 수정된 모델은 두 종류로 구현되었다. (1) 첫 번째 모델에서는, 시술 직후의 상황을 재현하기 위해 골이식물과 종판의 경계면에 접촉요소를 사용하였다. (2)두 번째 모델에서는 완전히 융합된 상황을 나타내기 위해 골이식물을 종판에 고정하였다. 골다공증의 효과를 예측하기 위하여 두 모델의 해면골에 대한 탄성계수를 변화시켰다(정상: 100MPa, 골다공증: 40MPa). 각 모델의 C5 주체의 상위면에 73.6N의 압축 하중을 가한 후에 108Nm의 굴곡/신전, 굽힘, 비틀림 하중을 가하였으며, C6 추체의 하단면은 모든 방향에 대하여 구속하였다. 전체적인 결과에 있어서 상대적 회전운동, 미끄럼운동, 골이식물 내에서의 von Mises 응력의 경우 정상 모델에 비해 골다공증 모델에서 증가함을 보였으며, 특히 시술 직후의 모델에서 비틀림 하중이 가해진 경우, 상대적 회전운동 및 미끄럼 운동이 가장 높게 예측되었다. 이는 골다공증환자에게 전방 내고정 장치를 시술한 경우 골이식물의 파단 및 유합의 실패가 비틀림 하중에서 발생할 수 있음을 나타낸다. 해면골의 von Mises 응력은 시술 직후에 골다공증 모델의 모든 하중 모드에서, 유합 후에는 굽힘 하중 외의 모든 하중에서 ultimate strength를 초과하는 것으로 나타나 골다공증 환자에게 screw의 해리가 발생할 가능성이 높은 것으로 예측되었다. 따라서 골다공증 환자에게 과도한 운동이 발생하지 않도록 하기 위해서 시술 후 세심한 주의와 halo 같은 견고한 정형술이 필요할 것으로 사료된다.

  • PDF

Comparison between Posterior and Transforaminal Approaches for Lumbar Interbody Fusion

  • Park, Jae-Sung;Kim, Young-Baeg;Hong, Hyun-Jong;Hwang, Sung-Nam
    • Journal of Korean Neurosurgical Society
    • /
    • 제37권5호
    • /
    • pp.340-344
    • /
    • 2005
  • Objective: Posterior lumbar interbody fusion(PLIF), the current leading method of pedicle screw fixation combined with interbody fusion via posterior route, sometimes requires too much destruction of the facet joint than expected especially for the patient with a narrow spine. On the other hand, tranforaminal lumbar interbody fusion(TLIF) technique provides potential advantages over PLIF and can be chosen as a better surgical alternative to more traditional fusion methods in certain surgical conditions. Methods: From October 1999, 99 PLIF and 29 TLIF procedures were done for the patients with spinal stenosis and instability. Radiological data including the interpedicular distance and the size of the pedicles as well as the clinical parameters were collected retrospectively. The degree of resection of the inferior articular process was compared with the interpedicular distance in each patient who received PLIF. Results: No significant differences were found between PLIF and TLIF regarding the operation time, blood loss, duration of hospital stay, or short term postoperative clinical result. There were no complication with TLIF, but PLIF resulted in 9(9.1%) complications. During PLIF procedure, all patients(n=24) except one with the interpedicular distance shorter than 27mm required near complete or complete resection of the inferior articular processes, whereas only 6(31.5%) of 19 patients with the interpedicular distances longer than 30mm required the similar extent of resection. Conclusion: TLIF is better than PLIF in terms of the complication rate. The patient who had narrow interpedicular distance(<27mm) might be better candidate for TLIF.

A Biomechanical Comparison of Intralaminar C7 Screw Constructs with and without Offset Connector Used for C6-7 Cervical Spine Immobilization : A Finite Element Study

  • Qasim, Muhammad;Hong, Jae Taek;Natarajan, Raghu N.;An, Howard S.
    • Journal of Korean Neurosurgical Society
    • /
    • 제53권6호
    • /
    • pp.331-336
    • /
    • 2013
  • Objective : The offset connector can allow medial and lateral variability and facilitate intralaminar screw incorporation into the construct. The aim of this study was to compare the biomechanical characteristics of C7 intralaminar screw constructs with and without offset connector using a three dimensional finite element model of a C6-7 cervical spine segment. Methods : Finite element models representing C7 intralaminar screw constructs with and without the offset connector were developed. Range of motion (ROM) and maximum von Mises stresses in the vertebra for the two techniques were compared under pure moments in flexion, extension, lateral bending and axial rotation. Results : ROM for intralaminar screw construct with offset connector was less than the construct without the offset connector in the three principal directions. The maximum von Misses stress was observed in the C7 vertebra around the pedicle in both constructs. Maximum von Mises stress in the construct without offset connector was found to be 12-30% higher than the corresponding stresses in the construct with offset connector in the three principal directions. Conclusion : This study demonstrated that the intralaminar screw fixation with offset connector is better than the construct without offset connector in terms of biomechanical stability. Construct with the offset connector reduces the ROM of C6-7 segment more significantly compared to the construct without the offset connector and causes lower stresses around the C7 pedicle-vertebral body complex.

Comparative effects of systemic administration of levofloxacin and cephalexin on fracture healing in rats

  • Golestani, Shayan;Golestaneh, Arash;Gohari, Atousa Aminzadeh
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제48권2호
    • /
    • pp.94-100
    • /
    • 2022
  • Objectives: This study aimed to compare the effects of systemic administration of levofloxacin or cephalexin on fracture healing in rats. Materials and Methods: In this animal study, tibial fractures not requiring fixation were artificially induced in 30 male Wistar albino rats using a 1.1 mm surgical bur. The rats were randomly divided into 6 groups (n=5). Groups 1 and 2 received daily subcutaneous saline injections. Groups 3 and 4 received subcutaneous injections of 25 mg/kg levofloxacin twice daily. Groups 5 and 6 received daily subcutaneous injections of 20 mg/kg cephalexin. The rats in Groups 1, 3, and 5 were sacrificed after 1 week, while the rats in Groups 2, 4, and 6 were sacrificed after 4 weeks. The score of fracture healing was determined through histological assessment of sections from the fracture site according to Perry and colleagues. Data were analyzed by Kruskal-Wallis and Mann-Whitney tests. Results: The mean score of fracture healing at 4 weeks was significantly higher than that at 1 week in the saline, levofloxacin, and cephalexin groups (P<0.001). At 1 week, no significant difference was noted among the three groups of saline, levofloxacin, and cephalexin in the mean score of fracture healing (P=0.360). However, this difference was significant at 4 weeks (P=0.018), and the mean score in the saline group was significantly higher compared to that in the levofloxacin group (P=0.015). Conclusion: It is recommended not to prescribe levofloxacin for more than 1 week after surgical management of bone fractures due to its possible adverse effects on fracture healing.