• 제목/요약/키워드: N and P Removal

검색결과 998건 처리시간 0.027초

철전기분해장치(FNR)에서 단위공정에 따른 질소와 인의 제거 (A Study on Phosphorus and Nitrogen Removal with Unit Operation in the Ferrous Nutrient Removal Process)

  • 김수복;김영규
    • 한국환경보건학회지
    • /
    • 제39권1호
    • /
    • pp.83-89
    • /
    • 2013
  • Objectives: The purpose of this experiment was to illuminate the relationship between the phosphorus removal rate of unit operation and the phosphorus removal rate of phosphorus volume loading in the Ferrous Nutrient Removal process, which consists of an anoxic basin, oxic basin, and iron precipitation apparatus. Methods: This study was conducted in order to improve the effect of nitrogen and phosphorus removal in domestic wastewater using the FNR (Ferrous Nutrient Removal) process which features an iron precipitation reactor in anoxic and oxic basins. The average concentration of TN and TP was analyzed in a pilot plant ($50m^3/day$). Results: The removal rate of T-N and T-P were 66.5% and 92.8%, respectively. The $NH_3-N$ concentration of effluent was 2.62 mg/l with nitrification in the oxic basin even though the influent was 17.7 mg/l. The $NO_3$-N concentration of effluent was 5.83 mg/l through nitrification in oxic basin even though the influent and anoxic basin were 0.82 mg/l and 1.00 mg/l, respectively. The specific nitrification of the oxic basin ($mg.NH_3$-Nremoved/gMLVSSd) was 16.5 and specific de-nitrification ($mg.NO_3$-Nremoved/gMLVSSd) was 90.8. The T-P removal rate was higher in the oxic basin as T-P of influent was consumed at a rate of 56.3% in the anoxic basin but at 90.3% in the oxic basin. The TP removal rate (mg.TP/g.MLSS.d) ranged from 2.01 to 4.67 (3.06) as the volume loading of T-P was increased, Conclusions: The test results showed that the electrolysis of iron is an effective method of phosphorus removal. Regardless of the temperature and organic matter content of the influent, the quality of phosphorus in the treated water was both relatively stable and high due to the high removal efficiency. Nitrogen removal efficiency was 66.5% because organic matter from the influent serves as a carbon source in the anoxic basin.

Isolation, identification and immobilized-cell characteristics of a bacterium that produces $N_2$ from $NH{_4}{^+}$ under an aerobic condition

  • Park, Kyoung-Joo;Cho, Kyoung-Sook;Kim, Jeong-Bo;Lee, Min-Gyu;Lee, Byung-Hun;Hong, Young-Ki;Kim, Joong-Kyun
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2005년도 생물공학의 동향(XVII)
    • /
    • pp.450-455
    • /
    • 2005
  • To treat wastewater efficiently by a one-step process of nitrogen removal, a new strain of $N_2-producing$ bacteria from $NH{_4}{^+}$ under an aerobic condition was isolated and identified. By 16S-rDNA analysis, the isolate was identified as Enterobacter asburiae with 96% similarity. The isolate shows that the capacity of $N_2$ production under an oxic condition was approximately three times higher than that under an anoxic condition. The optimal conditions (pH, temperature and C/N ratio) of the immobilized isolate for $N_2$ production were found to be 7.0, $30^{\circ}C$ and 5, respectively. Under all the optimum reaction conditions, the removal efficiency of $COD_{Cr}$ and TN reached 56.1 and 60.9%, respectively. The removal rates of $COD_{Cr}$ and TN were highest for the first 2.5 hrs (with the removal $COD_{Cr}$ ratios of 32.1), and afterwards the rates decreased as reaction proceeded. For application of the immobilized isolate to a practical process of ammonium removal, a continuous bioreactor system exhibited a satisfactory performance at HRT of 12.1 hr, in which the effluent concentrations of $NH{_4}{^+}-N$ was measured to be 15.4 mg/L with its removal efficiency of 56.0%. The maximum removal rate of $NH{_4}{^+}-N$ reached 1.6 mg $NH{_4}{^+}-N/L/hr$ at HRT of 12.1 hr (with N loading rate of 0.08 $Kg-N/m^3-carrier/d)$. As a result, the application of the immobilized isolate appears a viable alternative to the nitrification-denitrification processes.

  • PDF

Scenedesmus sp.를 이용한 하수의 영양물질 제거에 관한 연구 (A Study on the Nutrient Removal of Wastewater Using Scenedemus sp.)

  • 이희자
    • 한국환경과학회지
    • /
    • 제8권4호
    • /
    • pp.443-449
    • /
    • 1999
  • This paper describe the working of algal culture system under batch and continuous feeding effluents in biological treatment process. The main objective of this study was the determination of fundamental opeating parameters such as dilution rates, light intensity, biomass concentration, nutrients contents, which engender an effective nutrient and organic waste removal process. The results of this research indicate that the algae system will remove effectively nutrient and organic waste. In batch cultures, 91.8% dissolved orthophosphate and 83.3% ammonia nitrogen were removed from the sewage in ten days. In continuous flow systems, a detention time of 2.5 days was found adequate to remove 91% T-P, 87% T-N and 95% $NH_3-N$. At 22-28$^{\circ}C$, 60 rpm, with an intensity of 3500 Lux, the specific growth rate, k was 0.59/day in batch experiments. The optimal growth temperature and nutrients rate (N/P) were respectively $25^{\circ}C$ and 3~5. With an abundant supply of untrients, it was possible to sustain substantial population densities in the temperature range of 22~28$^{\circ}C$.

  • PDF

휘발성 지방산의 주입을 통한 생물학적 영양염류 제거공정의 효율증진에 관한 연구 (Enbancement of Treatement Efficiency in a Biological Nutrient Removal Process by addition of Volatile Fatty Acids)

  • 정연규;고광백;김수진;임성균
    • 상하수도학회지
    • /
    • 제10권3호
    • /
    • pp.73-82
    • /
    • 1996
  • The removal efficiencies of organic substrates, nitrogen and phosphorus in the anaerobic-aerobic biological phosphorus removal process were investigated by addition of acetic acid, propionic acid and butyric acid which are normal volatile fatty acids contained in anaerobic digester supernatants. Substrate utilization coefficients for the phosphorus release and uptake were also estimated. The effect of a VFA, which showed higher phosphorus removal efficiency than the other VFAs did, was also studied in an anaerobic-aerobic-anoxic biological nutrient removal process. For the anaerobic-aerobic process added by VFA, the phosphorus removal efficiencies were up to about 68%, 55% and 61% for the reactors of acetic acid, propionic acid and butyric acid added, respectively, which indicates the efficiencies were increased by about 8-21%, comparing to that of 47% for the reactor with no VFA added. There were no significant difference in removal efficiencies for organic substrate and $NH_3-N$ without regard to addition of VFA. However, the removal efficiency of total nitrogen was increased in the case of VFA added, since $NO_3-N$ was less produced. For the anaerobic-aerobic-anoxic process added VFA, the removal efficiencies for $NH_3-N$ and $PO{_4}^{3-}-P$ were increased by 5% and 13%, respectively, comparing with them in the reactors not added VFA.

  • PDF

생물학적 질소.인 동시제거 시스템에서 탈질미생물의 인 제거 가능성 (Possibility of Anoxic Phosphorus Removal by Denitrifier in Denitrifying EBPR System)

  • 이한샘;윤주환
    • 한국물환경학회지
    • /
    • 제29권6호
    • /
    • pp.782-789
    • /
    • 2013
  • Enhanced biological phosphorus removal (EBPR) behavior and microbial characteristics in the anaerobic-aerobic SBR (PAO SBR) and the anaerobic-anoxic SBR (DPAO SBR) were examined in this research. For 392 days of operation, both SBRs have exhibited a good EBPR (or denitrifying EBPR) performance. $P_{release}/P_{influent}$ ratio was highest in both reactors after the stabilization, while the efficiency of phosphorus removal was decreased since the sludge granulation has been visually observed within the reactor. The comparative analysis of Pyrosequencing-based microbial population between PAO and DPAO sludges showed indirectly that Dechloromonas spp. could utilize $O_2$ and $NO_3{^-}-N$ as an electron acceptor and Accumulibacter phosphatis use only $O_2$ in EBPR system. Also, we concluded that Thauera spp. as a denitrifier contribute significantly to the anoxic phosphorus removal in the DPAO system.

저수지 수질개선을 위한 식생정화시스템 (A Vegetation Purification System for Water Quality Improvement in Irrigation Reservoirs)

  • 박병흔
    • 한국농공학회지
    • /
    • 제42권4호
    • /
    • pp.87-95
    • /
    • 2000
  • A vegetation purification system was applied to improve water quality of Masan Reservoir in Korea, which was composed of constructed wetlands in series. Five different kinds of macrophytes were planted in each wetland. The system was operated with the condition of low concentrations and high hydraulic loadings. Removal efficiencies(%) of chemical oxygen demand(COD) , total nitrogen(T-N) and total phosphorus(T-P) in this system were 9.0, 12.8, 20.1% , respectively. and removal rates(g/$m^2$/d) were 1.9(COD), 0.34(T-N) and 0.05(T-P) . Comparing this system with other wetlands operated at low hydraulic loadings, average removal efficiencies were low but removal rates were relatively high. Accordingly, this system could be applied to imporve reservoir water quality, because removal rates are more important than removal efficiencies in case of reservoir water quality improvement . However, the removal efficiencies and rates of this system are less than those of the hydroponic biofilter method which is a kind of a constructed wetland and utilize root zones of emergent macrophytes for trapping pollutants. Therefore, it is recommended that this system should be modified to utilize root zones of emergent macrophytes enough to improve reservoir water quality more efficiently.

  • PDF

재순환에 의한 한국형 Biofilter System 의 질소.인 제거 (Removal of treatment efficiency for nutrients by recirculation in Korean Type Biofilter System)

  • 전기설;권순국
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2003년도 학술발표논문집
    • /
    • pp.611-614
    • /
    • 2003
  • A Korean Type Biofilter system combined with a conventional anoxic tank(septic tank) process was investigated in regard to its feasibility for removing organic as well as nutrients from the rural wastewater in Korea. At recirculation, the removal rate in BOD and SS increased slightly as much as 93 and 95% compared with non-recirculation system. On the other hand, removal rates of the total nitrogen(T-N) and total phosphorous(T-P) in recirculation system increased significantly as much as 62 and 57%, respectively compared with non-recirculation system. The recirculation system provides sufficient treatment to improve the removal rate in T-N and T-P.

  • PDF

SBR에서 아세트산을 이용한 양돈폐수의 질소·인 제거 특성 (Removal Characteristics of Nitrogen and Phosphorus in swine wastewater by Using Acetic acid on the SBR Process)

  • 허목;강진영
    • 유기물자원화
    • /
    • 제12권1호
    • /
    • pp.84-93
    • /
    • 2004
  • 본 연구는 생물학적 처리공정의 하나인 SBR을 이용하여, 양돈폐수중의 유기물과 질소, 인의 동시 제거를 목적으로 적정의 수리학적 체류시간(HRT)과 반응기간 중 교반/폭기 시간비(M/A) 및 적정의 교반/폭기 시간비에서의 외부탄소원의 주입기간(Injection Time)에 따른 변화에 따른 실험 결과로부터 다음과 같은 결론을 얻었다. (1) $NH_4{^+}-N$의 제거효율은 M/A가 0.0/22.0일 때(Run 1) 가장 효율이 좋았으며, 외부탄 소원을 주입했을 경우 탈질균의 증식으로 인해서 질산화가 잘 이루어지지 않기 때문에 주입시간이 길어질수록 증가하였다. T-N의 제거효율은 M/A가 증가할수록, 외부탄소원 주입시간이 길어질수록 증가하였다. (2) T-P의 제거효율은 운전조건에 따라 큰 차이를 보이고 있으며, M/A가 증가할수록 제거효율은 증가하였으며, 외부탄소원의 주입기간을 두고 보았을때, 주입기간을 짧게 할 경우 탈질균의 증식으로 인해서 탈질이 더 효율적으로 이루어지기 때문에 그 제거효율은 증가하였다. (3) 총 반응시간 22시간 중 M/A 16.5/5.5, 무산소 기간의 16.5시간 중 15시간동안 외부탄소원을 주입했을 경우(Run 4-1)의 운전조건에서 유기물 및 질소 제거에 가장 효율적이었다. 각각의 효율을 살펴보면, $COD_{Cr}$, $COD_{Mn}$ 그리고 $BOD_5$인 경우, 각각 90.6%, 87.7% 그리고 96.1%이고, T-N의 경우 86.6%, T-P인 경우는 84.5%로 나타났다.

  • PDF

RESEARCH PAPERS : REMOVAL EFFICIENCY OF THE POLLUTANTS BY MULTILAYERED METAL TREATED CARBON FILTER

  • Oh, Won-Chun;Lee, Ho-Jin;Bae, Jang-Soon
    • Environmental Engineering Research
    • /
    • 제9권5호
    • /
    • pp.193-200
    • /
    • 2004
  • A study of the treatment of piggery wastes using a multilayered metal-activated carbon system followed by carbon bed filtration was carried out at bench scale. From the physicochemical properties obtained from samples treated with aqueous solutions containing metallic ions such as Ag$^+$, Cu$^{2+}$, Na$^{-}$, K$^+$ and Mn$^{2+}$, main inspections are subjected to isothem shape, pore distribution with micropore, SEM and EDX. Multilayered metal-activated carbons were contacted to waste water to inwestigate the simultaneous catalytic effect for the COD, BOD, T-N and T-P removal. From these removal performance was achieved. The high efficiency of the multilayered metal-activated carbon bed, satisfactory removal performance was achieved. The high efficiency of the multilayered metal-activated carbon bed was derermined by the properties of this material for trapping, catalytic effect and adsorption of organic solid particles.

Ankistrodesmus bibraianus의 최적 배양조건 설정을 통한 수질오염물질 제거 및 축산 폐수 처리 적용 (Removal of water pollutants and its application to swine wastewater treatment through the establishment of best optimal growth conditions of Ankistrodesmus bibraianus)

  • 황인성;박영민;이예은;김덕원;박지수;오은지;유진;정근욱
    • 환경생물
    • /
    • 제38권1호
    • /
    • pp.82-92
    • /
    • 2020
  • 축산 폐수는 고농도의 영양염류와 중금속을 함유하고 있어, 배출될 때 수질을 악화시킨다. 기존 처리 기술과 비교하여 bioremediation은 축산 폐수 처리에 유능하다. 특히, 미세조류는 오염물질 제거에 잠재력을 가지고 있다. 본 연구에서는 Ankistrodesmus bibraianus를 이용하여 축산 폐수 내 영양염류(질소(N), 인(P))와 중금속(구리(Cu), 아연(Zn))의 제거 가능성을 평가하고, A. bibraianus의 최적 배양조건을 확립하였다. 연구결과, 최적 배양조건은 28℃, pH 7, 광주기는 14:10 h로 설정되었다. N과 P의 단일 처리구(500, 1,000, 5,000, 10,000mg L-1)에서 제거효율은 각각 22.9~80.6%와 11.9~50.0%였다. 또한, N과 P의 복합 처리구에서 제거효율은 각각 16.4~58.3%와 7.80~49.8%였다. Cu와 Zn의 단일 처리구(10, 30, 50mg L-1)에서 제거효율은 각각 15.5~81.5%와 6.28~34.3%였다. 유사하게, Cu와 Zn의 복합 처리구에서 제거효율은 각각 16.7~74.5%와 5.58~27.5%였다. 또한 영양염류(N 및 P)와 중금속(Cu 및 Zn)의 성장 및 제거효율을 축산 폐수에 적용할 수 있음을 나타냈다. 본 연구의 결과에 따르면 A. bibraianus는 축산 폐수 내 영양염류와 중금속 제거에 이용할 수 있을 것으로 사료된다.