• Title/Summary/Keyword: Mutual Distance

Search Result 167, Processing Time 0.03 seconds

Novel Mutual Inductance Formula for the Magnetic Resonance Wireless Power Transmission System Using Helical Coils (헬리컬 코일을 이용하는 자기 공진형 무선 전력 전송 시스템에서 새로운 상호 인덕턴스의 계산식 제안)

  • Jang, Ju-Yeop;Hur, Jung;Kim, Yong-Nam
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.6
    • /
    • pp.669-681
    • /
    • 2012
  • In this paper, analytical calculations using a novel mutual inductance formula for a resonant wireless power transmission system using helical coils. The look-up table of critical variables during the mutual inductance calculation process was formulated. The calculation results for resonant frequency and insertion loss were compared with experimental results when the distance between the two helical coils in a structure where the transmission and reception is symmetrical was varied with 10 mm increments from 53 mm to 500 mm. On average, the resonant frequency showed a difference of 5.63 % between the experimental results and the calculation results. The insertion loss had an average difference 2.25 dB where the smallest difference of 0.33 dB occurred with 290 mm. It was found that the experimental results without using a balun were in greater agreement with the calculation results.

The Types of Family System and Psychological Distance in Family Perceived by Adolescent Child (청소년기 자녀가 지각한 가족체계유형과 가족내 심리적 거리)

  • 최윤실
    • Journal of Families and Better Life
    • /
    • v.11 no.1
    • /
    • pp.159-175
    • /
    • 1993
  • The purpose of this study was to find out the psychological distance through semantic app-roach perceived by adolescent child in the subtypes of 'Extrem Family' dysfunctional families by classification of Olson and his associates ' Circrumplex Model. The subjects of this research were 1072 abolescents living in Seoul. Korea The survey methods were questionnaires including FACES II and The Psychological Distance Scale. Data were analyzed by means of the statistics of frequency percentage arithematic mean standard devia-tion crosstabs and one way-anova. The major findings are as follows: 1) The levels of family cohesion family adaptibility and the psychologival distances with father mother and siblings perceived by adolescent were high. 2) The most of subject's families belonged to 'Balanced Family' in the types of family system ' Extreme Family' type showed the lowest frequency and the main subtypes of it that had the highest frequency were 'Enmeshed Chaotic Family' ' Disengaged Rigid Family' 3) While adolescents of 'Enmeshed Chaotic Family' perceived most closely with other family members. those of 'Disengated Rigid Family' most distantly totally and in evaluation potency and activity three subfactors in psychological distance. 4) There were differences of unit points in subfactors of psychological distances with other family members perceived by adolescents according to the types of family system. While the points of 'Enmeshed Chaotic Family' were the highest those of 'Disengaged Rigid Family' were the lowest. 5) While 'Enmeshed Chaotic Family' were located most closely 'Disengaged Rigid Family' were located most distantly in the mutual distances and direct distances among family concepts on semantic space.

  • PDF

A Study on the Magnetic Field Intensity and BER from Wayside Device to On-board Device about the Train Speed in ATP System (ATP 시스템에서 열차속도에 따른 지상자에서 차상자까지의 자계의 세기 및 비트오류율에 관한 연구)

  • Kim, Min-Seok;Lee, Sang-Hyeok;Lee, Jong-Woo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.10
    • /
    • pp.1803-1808
    • /
    • 2010
  • Electric railway system consists of rolling stock, track, signal and catenary system. ATP system in railway signaling system is the important one grasping the position and velocity of a train. The wayside device of ATP system is installed between rails. Recently, the research about increasing train speed has been developed in total departments of the railroad systems. The study on the information transmission between on-board device and wayside device is required for increasing the train speed in the ATP system. When the train speed is increased as to same transmission distance, the problem on information transmission occurs because the transmission time is decreased. In case that the transmission distance is extended, the transmission time is decreased with respect to the train speed. Therefore, we have to define the standard magnetic field intensity as to the train speed in order to transmit correctly telegram. In this paper, the transmission distance for the telegram is suggested on the basis of the train speed. Also, the standard magnetic field intensity from the wayside device to on-board device is proposed by using transmission distance regarding the train speed in the ERTMS/ETCS system by using Matlab program. Also, BER according to the train speed is presented by calculating electric field intensity from the magnetic field intensity.

A Study on the Decision-making of Industrial Location in view of Substituting Production factors (생산요소(生産要素) 대체(代替)를 고려(考慮)한 공업입지(工業立地)의 의사결정(意思決定)에 관한 연구(硏究))

  • Jeon, Man-Sul;Kim, Man-Sik
    • Journal of Korean Society for Quality Management
    • /
    • v.13 no.1
    • /
    • pp.41-50
    • /
    • 1985
  • The purpose of this study is to consider the criteria for decision-making of industrial location in view of substituting production factors through maximizing profit instead of minimizing transportation cost. This paper makes use of mutual relationship between spatial economy in Euclidean distance and substituting production factors in production theory. Therefore, this paper will develop weak points in classical theory of industrial location by introducing production theory which has conception of substituting production factors.

  • PDF

Fingerprint Images Registration Method by Recursive Ridge Mapping (점진적 융선 정합을 통한 지문 영상 정렬 방법)

  • Choi, Kyoung-Taek;Choi, Hee-Seung;Kim, Jai-Hie
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.1007-1010
    • /
    • 2005
  • This paper presents a fingerprint image registration method. In the fingerprint system, the insufficiency of mutual information between a template and a query fingerprint is one of major factors to deteriorate recognition performance. To overcome this problem, we need to register multiple impressions and integrate their information. Our method matches the ridges from multiple impressions recursively and then registers the impressions to minimize the registration error calculated from the Distance map. Our method use regularized TPS model as the transformation model to compensate for the plastic deformation. We compare our method with 3 prior arts (ICP, Distance Map, Ross's method). Our registration error and its' variance is the smallest and also the average registration error is below 3 pixels.

  • PDF

Recognition and positioning of occuluded objects using polygon segments (다각형 세그먼트를 이용한 겹쳐진 물체의 인식 및 위치 추정)

  • 정종면;문영식
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.5
    • /
    • pp.73-82
    • /
    • 1996
  • In this paper, an efficient algorithm for recognizing and positioning occuluded objects in a two-dimensional plane is presented. Model objects and unknown input image are approximated by polygonal boundaries, which are compactly represented by shape functions of the polygons. The input image is partitioned into measningful segments whose end points are at the locations of possible occlusion - i.e. at concave vertices. Each segment is matched against known model objects by calculating a matching measure, which is defined as the minimum euclidean distance between the shape functions. An O(mm(n+m) algorithm for computing the measure is presentd, where n and m are the number of veritces for a model and an unknown object, respectively. Match results from aprtial segments are combined based on mutual compatibility, then are verified using distance transformation and translation vector to produce the final recognition. The proposed algorithm is invariant under translation and rotation of objects, which has been shown by experimental results.

  • PDF

Weight Vector Analysis to Portfolio Performance with Diversification Constraints (비중 상한 제약조건에 따른 포트폴리오 성과에 대한 투자 비중 분석)

  • Park, Kyungchan;Kim, Hongseon;Kim, Seongmoon
    • Korean Management Science Review
    • /
    • v.33 no.4
    • /
    • pp.51-64
    • /
    • 2016
  • The maximum weight of single stock in mutual fund is limited by regulations to enforce diversification. Under incomplete information with added constraints on portfolio weights, enhanced performance had been reported in previous researches. We analyze a weight vector to examine the effects of additional constraints on the portfolio's performance by computing the Euclidean distance from the in-sample tangency portfolio, as opposed to previous researches which analyzed ex-post return only. Empirical experiment was performed on Mean-variance and Minimum-variance model with Fama French's 30 industry portfolio and 10 industry portfolio for the last 1,000 months from August 1932 to November 2015. We find that diversification-constrained portfolios have 7% to 26% smaller Euclidean distances with the benchmark portfolio compared to those of unconstrained portfolios and 3% to 11% greater Sharpe Ratio.

Design for Triple Band Patch Array Antenna with High Detection Ability

  • Kim, In-Hwan;Min, Kyeong-Sik
    • Journal of electromagnetic engineering and science
    • /
    • v.13 no.4
    • /
    • pp.214-223
    • /
    • 2013
  • This paper proposes a theoretical analysis of hidden device detection and a design of multiband circular polarization patch array antenna for non-linear junction detector system application. A good axial ratio of circular polarization patch antenna is realized by a new approach that employs inclined slots, two rectangular grooves and a truncated ground for the conventional antenna. A good axial ratio of the 1.5 dB lower is measured by having an asymmetric gap distance between the ground planes of the coplanar waveguide feeding structure. The common ground plane of the linear array has an optimum trapezoidal slot array to reduce the mutual coupling without increasing the distance between the radiators. The higher gain of about 1 dBi is realized by using the novel common ground structure. The measured return loss, gain, and axial ratio of the proposed single radiator, as well as the proposed array antennas, showed a good agreement with the simulated results.

Current Distribution Factor Based Fault Location Algorithms for Double-circuit Transmission Lines (전류분배계수를 사용하는 병행 2회선 송전선로 고장점 표정 알고리즘)

  • Ahn, Yong-Jin;Kang, Sang-Hee;Choi, Myeon-Song;Lee, Seung-Jae
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.3
    • /
    • pp.146-152
    • /
    • 2001
  • This paper describes an accurate fault location algorithm based on sequence current distribution factors for a double-circuit transmission system. The proposed method uses the voltage and current collected at only the local end of a single-circuit. This method is virtually independent of the fault resistance and the mutual coupling effect caused by the zero-sequence current of the adjacent parallel circuit and insensitive to the variation of source impedance. The fault distance is determined by solving the forth-order KVL(Kirchhoff's Voltage Law) based distance equation. The zero-sequence current of adjacent circuit is estimated by using a zero-sequence current distribution factor and the zero-sequence current of the self-circuit. Thousands of fault simulation by EMTP have proved the accuracy and effectiveness of the proposed algorithm.

  • PDF

Measurement of Magnetic and Electric Field from Kwachun Power Transmission Lines (과천 송전선로 전자계 측정)

  • Kim, D.W.;Ryu, C.Y.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.353-356
    • /
    • 1996
  • Early this year the construction of new high voltage power lines have been forced to stop due to the demonstration of residents in Kwa-chun. According to mutual agreement between the residents and Korea Electric Power Corporation, electromagnetic field(EMF) from present power lines was measured and EMF after completion of new power lines was estimated. The results show that EMF near power lines Is relatively low, and EMFnear electric substation is quite high due to the short distance between the power lines and ground. For 4 conduction 345kV line, magnetic field decreases to 3mG at the distance of 50m from the power line.

  • PDF