• Title/Summary/Keyword: Muscle Wire

Search Result 34, Processing Time 0.023 seconds

Comparison of ROM and Muscle Activities According to the Skills of Surya Namaskara in Vinyasa Yoga (요가 수르야 나마스카 동작의 숙련도 차이에 따른 ROM과 근활성도 비교)

  • Hong, So-Yoen;Park, Jin;Hah, Chong-Ku
    • Korean Journal of Applied Biomechanics
    • /
    • v.19 no.1
    • /
    • pp.127-138
    • /
    • 2009
  • The purpose of this study was to investigate range of motion (ROM) and muscle activities according to the skills of Surya Namaskara in Vinyasa Yoga. Six females (skilled 2, unskilled 4) of university students participated in this experiment. The research factors were ROM and muscle activities for static poses on Surya Namaskara in Vinyasa Yoga. The six infrared cameras (Oqus 300, Qualisys Inc, Sweden) and Zero Wire EMG (Aurion, Italy) were used to acquire raw data, and the Qualisys Track Manager and Noraxon (MyoResearch XP Master Edition, USA) were used to process data. The %MVIC and ROM were analyzed with Visual 3D (C-Motion Inc, USA) and Noraxon. In conclusion, ROM and %MVIC between two groups were remarkable different according to the static poses of Yoga, therefore instructors have to provide step-by-step information that was suitable to themselves (ROM and EMG of poses).

Difficult airway management in a patient with a parapharyngeal tumor

  • Ji, Sung-Mi
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.15 no.3
    • /
    • pp.153-156
    • /
    • 2015
  • A 47-year-old man was referred to the operating room to treat a dentigenous cyst of the mandibular bone. Initial assessment of the airway was considered normal. However, after the induction of anesthesia, we could not intubate the patient due to severe distortion of the glottis. Fiberoptic bronchoscopy and video laryngoscopy were not effective. Intubation using a retrograde wire technique was successful. After the conclusion of surgery, the patient recovered without any complications. Subsequent magnetic resonance imaging of the patient's neck showed a $6{\times}4{\times}8.6cm$ heterogeneous T2 hyperintense, T1 isointense well-enhancing mass in the prestyloid parapharyngeal space. The patient was scheduled for excision of the mass. We planned awake intubation with fiberoptic bronchoscopy. The procedure was successful and the patient recovered without complications. Anesthetic induction can decrease the muscle tone of the airway and increase airway distortion. Therefore, careful airway assessment is necessary.

A technique for treating exposed cardiac Pacemaker (피부괴사로 노출된 심장 Pacemaker에 대한 처치 : 증례 보고)

  • Sin, Geuk-Seon;Yu, Jae-Deok;Hong, Seung-Rok
    • Journal of Chest Surgery
    • /
    • v.17 no.1
    • /
    • pp.125-128
    • /
    • 1984
  • The management of the exposed cardiac pacemaker or its lead is a new challenge to the plastic surgeon. This complication is not rare. Coburn et al. [1972] reported less than 5 percent, but Sowton et al. [1974] showed that over a period of 19 years, in a series of 372 patients, the pacing system had to be removed because of local wound breakdown or infection in 10 percent of the cases. The methods used to treat exposure may vary from removal and re-introduction at anterior site to the rotation of local flaps to cover the exposed pacemaker. Recently we have experienced 6 times of migration and recurrent skin ulcerations without pyogenic infection overlying the pacemaker in one patient. We developed a new technique, anchoring the pacemaker to the clavicle by a wire through the hole of clavicle and by creating a pocket under the pectoralis major muscle. Then we would like to emphasize this operating method could be choice of treatment to prevent the migration of pacemaker and the ulceration of skin when complication of implantation of pacemaker is occurred.

  • PDF

A Study on Design of Underactuated Robot Hand driven by Shape Memory Alloy (형상기억합금 Underactuated 로봇 핸드의 설계에 관한 연구)

  • Kim, Gwang-Ho;Shin, Sang-Ho;Jeong, Sang-Hwa
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.5
    • /
    • pp.51-57
    • /
    • 2011
  • The lightweight and compact actuator with high power is required to perform motion with multiple degrees of freedom. To reduce the size and inertia of a robot manipulator, the mechanical transmission system is used. The shape memory alloy(SMA) is similar to the muscle-tendon-bone network of a human hand. However, there are some drawback and nonlinearity, such as the hysteresis and the stress dependence. In this paper, the design of the underactuated robot hand is studied. The 3-finger dexterous hand is driven by the SMA actuator using segmental mechanism. This digital approach enables to overcome the nonlinearity of SMA wire. The translational displacement of SMA actuator required to bend a phalanx of the underactuated robot hand is estimated and the bending angle of the underactuated robot hand according to input displacement of SMA actuator is predicted by the multi-body dynamic analysis.

Sport impact on the strength of the nanoscale protein tissues under the thermal condition

  • Xin, Fang;Mengqian, Hou
    • Advances in nano research
    • /
    • v.13 no.6
    • /
    • pp.561-574
    • /
    • 2022
  • The stability of protein tissues and protein fibers in the human muscle is investigated in the presented paper. The protein fibers are modeled via tube structures embedded in others proteins fibers like the elastic substrate. Physical sport and physical exercise play an important role in the stability of synthesis and strength of the protein tissues. In physical exercise, the temperature of the body increases, and this temperature change impacts the stability of the protein tissues, which is the aim of the current study. The mathematical simulation of the protein tissues is done based on the mechanical sciences, and the protein fibers are modeled via wire structures according to the high-order theory beams. The thermal stress due to the conditions of the sport is applied to the nanoscale protein fibers, then the stability regarding the frequency analysis is investigated. Finally, the impact of temperature change, physical exercise, and small-scale parameters on the stability of the protein tissues are examined in detail.

Development of a Robotic Hand using Shape Memory Alloy Actuators (형상기억합금 구동기를 이용한 로봇 손 개발)

  • Jeon, Chang Gook;Yoo, Dong Sang
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.26 no.2
    • /
    • pp.147-152
    • /
    • 2016
  • Shape Memory Alloys (SMAs) undergo changes in shape and hardness when heated or cooled, and do so with great force. Since wire-type SMAs contract in length when heated and pull with a surprisingly large force and move silently, they can be used as actuactors which replace motors. These SMA actuators can be heated directly with electricity and can be used to create a wide range of motions. This paper presents the mechanical design and control for a three fingered, six degree-of-freedom robotic hand actuated by SMA actuators. Each finger has two joints and each joint is actuated with two tendons in the antagonistic manner. In order to create the sufficient force to make the smooth motion, the tendon is composed of two SMA actuators in parallel. For controlling the current to heat the SMA actuators, PWM drivers are used. In experiments, the antagonistic interaction of fingers are evaluated.

A STUDY ON THE EFFECT OF ELECTRO-ACUPUNCTURE ON ORAL PAIN (전기침이 구강동통에 미치는 영향에 관한 연구)

  • Choi, Yong-Sung;Lee, Chang-Seop;Song, Hyeong-Geun;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.23 no.3
    • /
    • pp.717-728
    • /
    • 1996
  • The effects of electro-acupuncture on the pain threshold and the amplitude of dEMG(di-gastric EMG) evoked by the noxious electric stimulation on teeth and gingiva in dogs were studied. Experiments were carried out with 10 dogs weighing 5-8kg. Each animal was anestheticed with Entobar given intraperitoneally in an initial dose of 30mg/kg. Maintenance dose of 5mg/kg/hr was given through a cannula, in the femoral vein, as required to keep up light anesthesia. Bipolar stimulating wire electrodes, 0.1mm in diameter, insulated except for tips, were inserted into the upper canine and palatal gingiva. Rectangular aluminium plate electrodes (15$\times$5mm) were placed on acupuncture points, called Yin-Hsiang, located at both sides of the upper jaw. Rectangular biphasic current pulses of 2Hz, with a $250{\mu}sec$ duration, were delivered for 15 minutes. The dEMG activities were recorded from the anterior belly of the digastric muscle(one of the jaw opening muscles) using bipolar wire electrodes. The magnitude of the jaw opening reflex at different intensties of electro-acupuncture(1volt 4volt and 10volt) was estimated by averaging the 30 superimposed dEMGs recorded on an oscilloscope and audiomonitor. Data were analysed statistically with ANOV A and paired t-test. The obtained results were as follows: 1. Pain thresholds were increased 7.7 %, 15.4 %, 17.3 % in the teeth and 11.1 %, 19.0 %, 25.4 % in the gingiva as the intensities of electro-acupuncture increased incrementally. 2. Amplitudes of dEMG were decreaed 8.3%, 22.4%, 27.4% in the teeth and 9.8%, 36.5%, 42.2 % in the gingiva as the intensities of electro-acupuncture increased incrementally. 3. Inhibition of pain responses by the electroacupuncture was more effective in the gingiva than in the teeth.

  • PDF

Electrical Stimulation Causes Endothelium-Dependent Relaxation in Isolated Aortic Vessels of the Rabbit (토끼 흉부 대동맥 절편의 전기자극에 대한 수축 및 이완반응)

  • Lee, Seok-Gi;Choe, Hyeong-Ho;Lee, Jong-Un
    • Journal of Chest Surgery
    • /
    • v.28 no.8
    • /
    • pp.742-746
    • /
    • 1995
  • The present study was aimed at investigating possible transmitter mechanisms in the endothelial cell layer in regulating the tone of the vascular smooth muscle. The thoracic aorta was isolated from the anesthetized male white rabbits and its helical strips were prepared. Electrical field stimulation was delivered to platinum wire electrodes positioned parallel to the vessel segment preconstricted with phenylephrine [3.5x10-6 mol/L at a distance of 1.5-2.0 mm. The electrical stimulation [70 V, 5 msec, 0.5-200 Hz caused either relaxation only [34% or a biphasic response [prolonged relaxation following a weak and transient contraction, 66% . The relaxation response was frequency- dependent, and at 200 Hz a complete relaxation was noted. Mechanical rubbing of the endothelial layer abolished or greatly attenuated the relaxation. The relaxation was also markedly attenuated in the presence of NG-nitro- L-arginine methyl ester [10-3mol/L or procaine hydrochloride [3.5x10-4mol/L . Tetrodotoxin,guanethidine, atropine or indomethacin failed to block or enhance the relaxation response to electrical field stimulation. It is concluded that the vascular endothelium in the aorta contains diffusible substances that regulates the function of the smooth muscle layer, in which relaxation is more prominent than contraction. Their release by the electrical stimualtion in vitro may not involve classic neuronal transmitter release mechanisms or metabolism of arachidonic acids by cyclooxygenase. The release of the relaxing agents may require an increase in cytosolic calcium level. The chemical nature of the relaxant may be, to a large extent, nitric oxide.

  • PDF

Differential expression of the enzymes regulating myosin light chain phosphorylation are responsible for the slower relaxation of pulmonary artery than mesenteric artery in rats

  • Seung Beom Oh;Suhan Cho;Hyun Jong Kim;Sung Joon Kim
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.28 no.1
    • /
    • pp.49-57
    • /
    • 2024
  • While arterial tone is generally determined by the phosphorylation of Ser19 in myosin light chain (p-MLC2), Thr18/Ser19 diphosphorylation of MLC2 (pp-MLC2) has been suggested to hinder the relaxation of smooth muscle. In a dual-wire myography of rodent pulmonary artery (PA) and mesenteric artery (MA), we noticed significantly slower relaxation in PA than in MA after 80 mM KCl-induced condition (80K-contraction). Thus, we investigated the MLC2 phosphorylation and the expression levels of its regulatory enzymes; soluble guanylate cyclase (sGC), Rho-A dependent kinase (ROCK) and myosin light chain phosphatase target regulatory subunit (MYPT1). Immunoblotting showed higher sGC-α and ROCK2 in PA than MA, while sGC-β and MYPT1 levels were higher in MA than in PA. Interestingly, the level of pp-MLC2 was higher in PA than in MA without stimulation. In the 80K-contraction state, the levels of p-MLC2 and pp-MLC2 were commonly increased. Treatment with the ROCK inhibitor (Y27632, 10 µM) reversed the higher pp-MLC2 in PA. In the myography study, pharmacological inhibition of sGC (ODQ, 10 µM) slowed relaxation during washout, which was more pronounced in PA than in MA. The simultaneous treatment of Y27632 and ODQ reversed the impaired relaxation in PA and MA. Although treatment of PA with Y27632 alone could increase the rate of relaxation, it was still slower than that of MA without Y27632 treatment. Taken together, we suggest that the higher ROCK and lower MYPT in PA would have induced the higher level of MLC2 phosphorylation, which is responsible for the characteristic slow relaxation in PA.

Measuring Range of Motion and Muscle Activation of Flower Arrangement Tasks and Application for Improving Upper Limb Function (꽃꽂이 작업의 관절가동범위와 근육활성도 측정 및 상지기능 향상을 위한 적용사례)

  • Lee, Son-Sun;Park, Sin-Ae;Kwon, Oh-Yun;Song, Jong-Eun;Son, Ki-Cheol
    • Horticultural Science & Technology
    • /
    • v.30 no.4
    • /
    • pp.449-462
    • /
    • 2012
  • The objectives of this study were to measure the range of motion for joints and muscle activation of upper limb for flower arrangement tasks for physical rehabilitation and to test horticultural therapy programs using flower arrangement tasks for improving upper limb function of the patients with stroke. Major flower arrangement tasks were classified with eight tasks (cutting 1, thick stem; cutting 2, thin stem; fixing 1, long stem; fixing 2, short stem; rolling a leaf; bending 1, thick stem; bending 2, thin stem; and winding, using a wire) based on the occupational analysis. When eight male university students (mean age $24.1{\pm}2.5$ years) conducted the eight flower arrangement tasks, range of motion for joints and muscle activation of upper limb were measured by a 3D motion analyzer and electromyography, respectively. Based on the results of the range of motion and muscle activation of upper limb, horticultural therapy programs using flower arrangement tasks (total 33 sessions) for improving upper limb function of the patients with stroke was conducted at a rehabilitation hospital, Seoul, South Korea and then the range of motion, grip strength, and upper limb function of the patients were tested. Among the eight flower arrangement tasks, cutting 1, winding, and bending 1 induced the highest value for the range of motion in joints of shoulder, elbow, and wrist, respectively (P < 0.001). In terms of muscle activation, eight flower arrangement tasks performed in this study showed various patterns of muscle activation and several muscles were simultaneously used for each task (P < 0.001). In addition, thickness and length of the materials used in a task had a prominent effect on the range of motion for joints and muscle activation of upper limb (P < 0.001). The stroke patients had positive effects for their range of motion of upper limb (shoulder, forearm, and elbow), grip strength, and overall upper limb function through the horticultural therapy program. Thus, this study suggested that flower arrangement tasks would be a potential horticultural activity for physical rehabilitation program. It would be interesting to apply a customized horticultural therapy program using flower arrangement tasks according to the symptoms of patient for physical rehabilitation.