• 제목/요약/키워드: Mura

검색결과 54건 처리시간 0.036초

FPD용 컬러 필터의 수지 얼룩 결함 형상화에 관한 연구 (A Study on the Visualization of Suzi Mora Defect of FPD Color Filter)

  • 권오민;이정섭;박덕천;주효남;김준식
    • 제어로봇시스템학회논문지
    • /
    • 제15권8호
    • /
    • pp.761-771
    • /
    • 2009
  • Detecting defects on FPD (Flat Panel Display) color filter before the full panel is made is important to reduce the manufacturing cost. Among many types of defects, the low contrast blemish such as Suzi Mura is difficult to detect using standard CCD cameras. Even skilled inspectors in the inspection line can hardly identify such defects using bare eyes. To overcome this difficulty, point spectrometer has been used to analyze the spectrum to differentiate such defects from normal color filters. However, scanning ever increasing-size color filters by a point spectrometer takes too long time to be used in real production line. We propose a system using a spectral camera which can be viewed as a line scan camera composed of an array of point spectrometers. Three types of lighting system that exhibit different illumination spectrums are devised together with a calibration method of the proposed spectral camera system. To visualize the defect areas, various processing algorithms to identify and to enhance the small differences in spectrum between defective and normal areas are developed. Experiments shows 85% successful visualization. of real samples using the proposed system.

소규모 정수처리장에서 모니터링 자료를 이용한 원수의 망간농도 예측에 관한 연구 (Estimation for Raw Water Quality of Manganese Concentrations from Archived Data in Small-scale Water Systems)

  • 민병대;야마자키 키미코;코이즈미 아키라;구자영
    • 상하수도학회지
    • /
    • 제25권4호
    • /
    • pp.547-554
    • /
    • 2011
  • In small-scale water systems, the measurement of quality of raw water in running water is generally implemented when the quality of water is stable and frequency of measurement is low. However, units such as water temperature and pH, which are easily monitored, are frequently measured. In establishing an improvement plan for a water treatment system, the range of concentration of the target material present in the raw water of the running water provides relevant information. If the concentration of target material can be specified by the quality of water of data items that are measured daily, inverse estimation of the range of concentration is possible as well. In this paper, we took note of manganese in the raw water from Ogasawara-mura, Tokyo, and estimated the manganese concentration in the raw water of the running water for the past five years. Based on the results obtained, we have proposed a manganese removal system, considering the current situation and geographical conditions of Ogasawara-mura.

Impact of aperture-thickness on the real-time imaging characteristics of coded-aperture gamma cameras

  • Park, Seoryeong;Boo, Jiwhan;Hammig, Mark;Jeong, Manhee
    • Nuclear Engineering and Technology
    • /
    • 제53권4호
    • /
    • pp.1266-1276
    • /
    • 2021
  • The mask parameters of a coded aperture are critical design features when optimizing the performance of a gamma-ray camera. In this paper, experiments and Monte Carlo simulations were performed to derive the minimum detectable activity (MDA) when one seeks a real-time imaging capability. First, the impact of the thickness of the modified uniformly redundant array (MURA) mask on the image quality is quantified, and the imaging of point, line, and surface radiation sources is demonstrated using both cross-correlation (CC) and maximum likelihood expectation maximization (MLEM) methods. Second, the minimum detectable activity is also derived for real-time imaging by altering the factors used in the image quality assessment, consisting of the peak-to-noise ratio (PSNR), the normalized mean square error (NMSE), the spatial resolution (full width at half maximum; FWHM), and the structural similarity (SSIM), all evaluated as a function of energy and mask thickness. Sufficiently sharp images were reconstructed when the mask thickness was approximately 2 cm for a source energy between 30 keV and 1.5 MeV and the minimum detectable activity for real-time imaging was 23.7 MBq at 1 m distance for a 1 s collection time.

Rubbing Cloth Evaluation Method for LCD Panels

  • Nakasu, Nobuaki;Honoki, Hideyuki
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2004년도 Asia Display / IMID 04
    • /
    • pp.328-330
    • /
    • 2004
  • In order to stabilize the rubbing process for liquid crystal panels, the authors developed "the sparkling dot area ratio evaluation method". This method quantifies the fiber length dispersion of rubbing cloths, which is a major cause of mura defects. The newly developed method enables quantitative evaluation of rubbing cloths and contributes to the improvement of rubbing process uniformity.

  • PDF

Novel high speed and sensitivity array test system for LTPS LCD and OLED

  • Chikamatsu, Kiyoshi;Miyake, Yasuhiro;Tajima, Kayoko;Goto, Masaharu;Mizoguchi, Junichi
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2006년도 6th International Meeting on Information Display
    • /
    • pp.1447-1450
    • /
    • 2006
  • The high speed and sensitivity array test system has been developed and utilized for massproduction of advanced LTPS displays including SOG and OLED. It realizes fast enough TACT enabling 100% inspection with better than 1fF sensitivity. The result of actual measurement shows its superior TACT and sensitivity, and also shows MURA detection of OLED panel.

  • PDF

Recent advances in excimer-laser-based crystallization for active-matrix displays

  • Turk, Brandon A.;Herbst, Ludolf;Simon, Frank;Paetzel, Rainer
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권1호
    • /
    • pp.12-15
    • /
    • 2007
  • Excimer-laser-based crystallization is ideallysuited for forming crystalline Si films on glass substrates for use in active-matrix displays. In this paper, we will report on recent and significant technical advances in light sources and beam delivery systems targeted at enabling ultra-uniform mura-free low-temperature polycrystalline silicon active-matrix backplanes while simultaneously lowering production costs and increasing throughput.

  • PDF

Research of the TFT-LCD Photosensitive Resist Thickness

  • Zhang, Mi;Xue, Jian She;Wang, Wei;Park, Chun-Bae;Koh, Jai-Wan;Zhang, Zhi-Min
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.1269-1271
    • /
    • 2008
  • We find some array mura are caused by S/D bridge or channel open in 4 mask process. The gray tone PR thickness non-uniformity is the main reason of these defects. By the adjustment of exposure and dry etch parameters, S/D bridge and channel open ratio drops by 10.87%.

  • PDF

Lowest-Cost Highest-Yield Superior Performance MVA LCDs by Amplified Intrinsic Fringe Field

  • Ong, Hiap L.;Liang, Justin;Guo, Jia Haw;Chen, I Hao;Wu, Chang Lin;Lan, Wei-Chou;Lin, Tung-Liang
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.1645-1648
    • /
    • 2008
  • We successfully fabricated lowest-cost superior perform ance MVA LCDs with highest-yield, high transmission, high contrast-ratio, and wide viewing angle. Using the amplified intrinsic fringe field (AIFF) controlled MVA invented by Ong, we eliminated all protrusions and ITO slit geometries. We further achieved: (1) faster gray-gray response times without the over-drive technology, (2) faster tough mura, and (3) lower flicker and cross-talk in the row inversion driving schemes.

  • PDF

APPLICATION OF WHOLE BODY COUNTER TO NEUTRON DOSE ASSESSMENT IN CRITICALITY ACCIDENTS

  • Kurihara, O.;Tsujimura, N.;Takasaki, K.;Momose, T.;Maruo, Y.
    • Journal of Radiation Protection and Research
    • /
    • 제26권3호
    • /
    • pp.249-253
    • /
    • 2001
  • Neutron dose assessment in criticality accidents using Whole Body Counter (WBC) was proved to be an effective method as rapid neutron dose estimation at the JCO criticality accident in Tokai-mura. The 1.36MeV gamma-ray of $^{24}Na$ in a body can be detected easily by a germanium detector. The Minimum Detectable Activity (MDA) of $^{24}Na$ is approximately 50Bq for 10miniute measurement by the germanium-type whole body counter at JNC Tokai Works. Neutron energy spectra at the typical shielding conditions in criticality accidents were calculated and the conversion factor, whole body activity-to-organ mass weighted neutron absorbed dose, corresponding to each condition were determined. The conversion factor for uncollied fission spectrum is 7.7 $[(Bq^{24}Na/g^{23}Na)/mGy]$.

  • PDF

Development of complete Culture System for Quail Embryos and Its Application for Embryo Manipulation

  • Ono, T.
    • 한국가금학회지
    • /
    • 제28권2호
    • /
    • pp.155-163
    • /
    • 2001
  • Gene and cell transfer technique will serve as a powerful tool for the genetic improvement of the poultry and to yield useful products. For avian transgenesis, Japanese quail may serve as an excellent animal model because of its small body size and fast growth rate. Recent progress was described on the manipulation of quail embryos such as the introduction of foreign genes and cells, and the subsequent culturing of the manipulated embryos yielding hatchlings. Intraspecific donor-derived offspring have been available in quail, however, further investigation will be required to obtain interspecific offspring with the aim of rescuing endangered species. Trans genesis will also be useful for improving the profitability and quality of poultry stocks and for developing stocks with novel uses. Considerable progress should soon be made toward the production of transgenic poultry. The key feature of the procedure described here is that embryos are initially taken out from the shell for ease of manipulation and then placed back in culture in addition to various operations midway during culture.

  • PDF