• Title/Summary/Keyword: Municipal wastewater treatment plant

Search Result 98, Processing Time 0.023 seconds

A Study on Initial and Near-Field Dilution at the Ocean Outfall of Masan-Changwon Municipal Wastewater Treatment Plant (마산ㆍ창원 하수종말 처리장의 해양방류 처리수에 대한 초기ㆍ근역 희석연구(I))

  • Kang See-Whan;You Sung-Hyup;Oh Byung-Cheol
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.2 no.2
    • /
    • pp.60-69
    • /
    • 1999
  • In this paper, we have obtained the initial and near-field dilution rates of wastewaters discharged from the ocean outfall of Masan-Changwon municipal wastewater treatment plant from both of field measurements and CORMIX model simulations. In the summer of 1998, water temperature and salinity profiles was measured at 16 stations in the vicinity of the Masan outfall and the dilution rates were analyzed by salinity deficit method. The transport of the wastefields and their initial dilution rates were calculated by CORMIX model using field data as model input. Both of observed and predicted results are shown In very low dilutions with the range of 32~48 from the field data analysis and 29~43 from the model prediction, respectively. This indicates that the water quality in the Masan outfall area can be worsening due to the low dilution rates of diswastewaters, especially, when the ambient currents are very weak in a neap tide and ambient water density is highly stratified in summer.

  • PDF

A Study on Advanced Municipal Wastewater Treatement by Daewoo Nutrients Removal (DNR) System (DNR 시스템에 의한 하수(下水)의 고도처리(高度處理)에 관한 연구(硏究))

  • Park, Myung-Gyun;Chang, Yun-Seok;Park, Chul-Hwi;Park, Chil-Lim
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.9 no.4
    • /
    • pp.115-123
    • /
    • 1995
  • The purpose of this study is to investigate the characteristics and performance of nitrogen and phosphorus removal system, Daewoo Nutrients Removal(DNR) system, and to find out the operating parameter for the system. During the study, $10m^3$ pilot plant was operated for the demonstration experiment and the primary effluent was taken from K domestic sewage treatment plant. The TN in the influent had been removed to approximately 70% through the nitrfication in the oxic tank and the denitrfication in the anoxic tank and the $PO_4-P$ and TP in the influent had been removed to 85% and 83% through anaerobic reaction and oxic reaction. The BOD and SS removal rate were 85 to 95% through the system. As the results, the values of effluent BOD, SS and slouble phosphorus were lower than A/O and $A^2/O$ processes. The SPRR (specific phosphorus release rate) at the anaerobic state of DNR system was ranged from 2.2 to 2.6mg SP/g VSS/h. The nutrient removal efficieny of the DNR system in view of the characteristics of the domestic sewage was higher than the pre-established A/O and $A^2/O$ processes. Finally, we believe that the DNR system was superior to the processes deveolped recently.

  • PDF

Sources and Distributions of Organic Wastewater Compounds on the Mokpo Coast of Korea

  • Choi, Min-Kyu;Choi, Hee-Gu;Moon, Hyo-Bang;Yu, Jun;Kang, Sung-Kyung;Choi, Su-Kyung
    • Fisheries and Aquatic Sciences
    • /
    • v.10 no.4
    • /
    • pp.205-214
    • /
    • 2007
  • Surface water and sediment samples collected from the Mokpo coast of Korea were analyzed for molecular markers of organic municipal wastewaters, i.e., 11 fecal sterols including coprostanol (Cop) and nonylphenolic compounds (NPs), to characterize the main routes of these wastewaters to the coast and to assess contamination levels. Concentrations of Cop ranged from 94 to 7,568 ng/L in surface water and from 43 to 38,108 ng/g dry weight in sediments. Concentrations of NPs [nonylphenol (NP) and nonylphenol mono- and di-ethoxylates ($NP_{1-2}EOs$)] ranged from 123 to 4,729 ng/L in surface water and from 4 to 2,119 ng/ng dry weight in sediments. The levels of these compounds were much higher at stations near the rivers that pass through the urban center of Mokpo and the outfall of the wastewater treatment plant (WWTP). The spatial distribution of Cop levels was statistically similar to that of NPs (r=0.809 and 0.982 in surface water and sediments, respectively), indicating that these compounds may have similar discharge points, transport, mixing, and deposition in the study area. These results suggest that considerable amounts of organic wastewater compounds are discharged through rivers and WWTP effluent to the Mokpo coast.

The Effect of Enzyme/Microbial Additive on Anaerobic Digestion of Primary Sludge

  • Kim, Hyung-Jin;Song, Chang-Soo;Kim, Dong-Wook;Pagilla, Kishna-R.
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.10 no.S_1
    • /
    • pp.35-40
    • /
    • 2001
  • Effect of the addition of an enzyme/microbial additive(EMA) to enhance anaerobic digestion of the primary sludge was investigated. Two laboratory scale anaerobic digester were operated with primary sludge taken from a municipal wastewater treatment plant. The digester receiving EMA with the sludge feed performed better than the control digester, when both were operated at 10-days and 15-days Solid Retention Time(SRT). Addition of EMA to the experimental digester provided 7%(10-days SRT) and 16%(15-days SRT) higher gas production compared to the control digester when both were fed with the same amount of volatile solids. The reduction in volatile solids was 24% better in the experimental digester compared to the control ar 10-days SRT, and the improvement 10% at 15-day SRT. Improvement in COD reduction, and fecal coliform density reduction were also seen in the experimental digester due to EMA addition compared to the control both ar 10-days SRT and 15-day SRT operation. Preliminary cost benefit analysis for a wastewater treatment plant showed that approximately $115/day in gas production improvements can be realized upon addition of EMA to primary sludge anaerobic digesters operating at 10-day SRT. The value of increased gas production was $172/day if the same digesters are operated with EMA addition at 15-day SRT.

  • PDF

New nirS-Harboring Denitrifying Bacteria Isolated from Activated Sludge and Their Denitrifying Functions in Various Cultures

  • LEE, SOO-YOUN;LEE, SANG-HYON;PARK, YONG-KEUN
    • Journal of Microbiology and Biotechnology
    • /
    • v.15 no.1
    • /
    • pp.14-21
    • /
    • 2005
  • By using PCR with nirS gene primers, three nirSharboring denitrifying bacteria (strain N6, strain N23, and strain R13) were newly isolated from activated sludge of a weak municipal wastewater treatment plant. Small-subunit rRNA gene-based analysis indicated that strain N6, strain N23, and strain R13 were closely related to Arthrobacter sp.,Staphylococcus sp., and Bacillus sp., respectively. In an attempt to identify their roles in biological nitrate and nitrite removal from sewage, we investigated their specific denitrification rates (SDNRs) for $NO_-^3$ - and $NO_-^2$ - in various cultures. All purecultures of each isolated nirS-harboring bacterial strain could remove $NO_-^3$ - and $NO_-^2$ - simultaneously in high efficiency, and the carbon requirements for $NO_-^3$ - removal of strain N6 and strain R13 were effectively low at 3.1 and 4.1 g COD/g $NO_3N$, respectively. In the case of mix-cultures of the strains (N6+N23, N6+R13, N23+R13, and N6+N23+R13), their SDNRs for $NO_-^3$ - were also effective, and their carbon requirements for $NO_-^3$ - removal were also effective at 3.0- 3.8 g COD/g NO3N. However, all tested mix-cultures accumulated $NO_-^2$ - in their culture media. On the other hand, the continuous culture of activated sludge mixed with strain N6 showed no significant increase of $NO_-^3$ - removal in comparison with strain N6's pure culture. These results suggest that nitrate and nitrite removal in biological wastewater treatment might be dependent on complicated bacterial interactions, including several effective denitrifying bacteria isolated in this study, rather than the specific bacterial types present and the number of bacterial types in activated sludge.

Changes of Treatment Efficiency According to Seasonal Variation in Rural Area (계절에 따른 농촌 지역 하수종말처리장의 처리 효율 변화)

  • Im, Jiyeol;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.17 no.3
    • /
    • pp.311-319
    • /
    • 2015
  • The Korean government has made progress in its project for sewage distribution in rural areas to ensure the balanced development of the country and its water conservation system. The project for sewage distribution in rural areas was analyzed with the yearly operational results of municipal wastewater treatment plant (MWTP). The sewage characteristics of the MWTP in a rural area changed according to seasonal variations, and the lowest pollution concentrations were obtained in the summer. The treatment efficiency of nutrients in the biological treatment process changed slightly more than the treatment efficiency of organic compounds, and the lowest treatment efficiency was obtained in winter. In addition, the relationship between treatment efficiency and retention time and F/M ratio showed similar results despite seasonal variations. It was considered that sewage characteristics and treatment efficiency changed according to seasonal variations when the treatment process was selected in MWTPs in rural areas. Especially, Maintenance of MWPT is need for the stable treatment efficiency of nutrients in the winter.

Study on Co-incineration of Municipal Solid Waste and Organic Sludges (도시쓰레기와 유기성 하수 슬러지 혼합소각에 관한 연구)

  • Jurng, Jong-Soo;Chin, Sung-Min
    • 한국연소학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.238-244
    • /
    • 2005
  • This study performs the pilot-plant experiments to evaluate the effect of the oxygen enrichment on the co-incineration of municipal solid waste and organic sludge from a wastewater treatment facility. The design capacity of the stoker-type incinerator pilot-plant is 150 kg/h. Combustion chamber temperatures were measured as well as the stack gas concentrations, i.e., NOx, CO, and the residual oxygen. The maximum ratio of organic sludge waste to the total waste input is 30%. Also the oxygen-enriched air with 23% of oxygen in supplied air is used for stable combustion. As the co-incineration ratio of the sludge increased up to 30% of the total waste input, the primary and the secondary combustion chamber temperature was decreased $to900^{\circ}C$ (primary combustion chamber), $750^{\circ}C$(secondary combustion chamber), respectively, approximately $200^{\circ}C$ below the incineration temperature of the domestic waste only (primary: $1,100^{\circ}C$, secondary: $950^{\circ}C$). However, if the supplied air was enriched to 22% oxygen content in air, the incinerator temperature was high enough to burn the waste mixture with 30% sludge, which has the heating value of 1,600 kcal/kg.

  • PDF

The Changes of Bacillus spp. in Municipal Wastewater Treatment Plant with B3 process. (B3 공법을 사용하는 하수종말처리장에서 Bacillus 속 세균의 변화)

  • 안태석;홍선희;김옥선;유재준;전선옥;최승익
    • Korean Journal of Microbiology
    • /
    • v.37 no.3
    • /
    • pp.209-213
    • /
    • 2001
  • By FISH and spore staining methods, the changes of Bacillus spp. numbers were investigated at municipal waste water treatment system, which operated with B3 process. Total bacterial numbers, which is the sum ofDAPI bound cells and numbers of spore, were ranged TEX>$3.2{\times}10^8 ~ 4.4{\times}10^8 $ cells/ml. The Bacilli numbers whichis the sum of probe S-G-Bacill-0597-a-A-22 bound cells and numbers of spore were from $0.3{\times}10^7 ~ 8.4{\times}10^7 $ cells/ml. The ratios of Bacillus sp. to total bacteria were ranged from 8 to 60%. Among 4 aeration tanks, thefirst tank had shown the highest proportions of Bacillus sp. And third and fourth tanks, the numbers of sporewere increasing.

  • PDF

Suggestions for Cost Improvement of High concentration Linked Treatment in Municipal Wastewater Treatment Plant (하수처리장에서의 연계처리수 요금 개선에 따른 경제성 분석)

  • Lee, Jiwon;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.22 no.2
    • /
    • pp.139-144
    • /
    • 2020
  • Recently, high-concentration linked wastewater has been introduced into a nearby municipal wastewater treatment plants(MWTPs), but it is difficult to MWTP in local governments due to an unreasonable linked treatment charge system, and there is insufficient evidence or data to prove this. However, the MWTP, which is a national essential infrastructure, is generally exempt from the preliminary feasibility study, so there have been no cases where economic evaluation was conducted. Therefore, we proposed an improvement plan that can compensate for the disadvantages of the existing linked processing charges through previous studies. In this study, a comparative evaluation of how much economic feasibility can be improved compared to the existing ones when applying the improvement plan by conducting an economic analysis. For this, reference was made to the preliminary feasibility assessment data of the existing environmental facilities and the cost factors and benefit factors established during the modernization of the old sewage treatment facilities. As a result of the study, the B/C(Benefit/cost) value was quite low in the past, but when the improvement proposal proposed by the researchers was applied, it was confirmed that the B/C value increased close to 1. Therefore, it is considered to be very reasonable to calculate the linkage processing charge according to the linked wastewater load proposed by the researchers.

Prediction of Near-Field Dilution Changes Due to Treatment Capacity Expansion of Masan-Changwon Municipal Wastewater Treatment Plant (마산.창원 하수종말처리장 증설에 따른 근역희석률변화 예측)

  • 유승협
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.12 no.2
    • /
    • pp.53-69
    • /
    • 2000
  • For the case of the capacity increase of Masan-Changwon wastewater treatment plant, the changes of near-field dilution rates due to the increased discharges into Masan Bay from the submerged multipart-diffuser were predicted by using CORMIX model. As the increase of wastewater discharges from currently 280,000 m3f day to 720,000 m3fday by 2011, the dilution rates become much lower than the present rates. To enhance the reduced dilution rates, the engineering design changes of diffuser length and alignment were considered as an optimal engineering option. According to the results of the model simulations for these changes, the dilution rates were increased in the strong ambient current of spring tide, but they were not affected by these changes in the weak current of neap tide in Masan Bay. From the analysis of oceanographic survey data, new outfalls sites have been searched. A promising outfalls site is selected and proposed on the basis of maximum obtainable dilution rates predicted by the model simulations.

  • PDF