• Title/Summary/Keyword: Municipal wastewater

Search Result 297, Processing Time 0.019 seconds

A Study of the Simultaneous Nitrification and Denitrification in a Single Bioreactor (단일 반응기를 이용한 동시 질산.탈질에 관한 연구)

  • Park, Jong-Il;Lee, Tae-Jin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.2
    • /
    • pp.220-228
    • /
    • 2007
  • In this study, effective simultaneous nitrification and denitrification reaction was accomplished in a completely mixed single bioreactor. As the important factors on the reaction, optimal DO concentration and effective range of influent C/N ratio was investigated with the synthetic wastewater. Experimental results show that stable nitrogen removals were accomplished with 0.5 mg/L DO concentration and over 7 C/N ratio. Nitrogen removal efficiency of the real municipal wastewater was low with 0.5 mg/L DO concentration because of its low C/N ratio. The increment of the C/N ratio at the inflow of the municipal wastewater with addition of external carbon source (glucose) over 7(up to 14) shows over 70% nitrogen removal in the single bioreactor.

New nirS-Harboring Denitrifying Bacteria Isolated from Activated Sludge and Their Denitrifying Functions in Various Cultures

  • LEE, SOO-YOUN;LEE, SANG-HYON;PARK, YONG-KEUN
    • Journal of Microbiology and Biotechnology
    • /
    • v.15 no.1
    • /
    • pp.14-21
    • /
    • 2005
  • By using PCR with nirS gene primers, three nirSharboring denitrifying bacteria (strain N6, strain N23, and strain R13) were newly isolated from activated sludge of a weak municipal wastewater treatment plant. Small-subunit rRNA gene-based analysis indicated that strain N6, strain N23, and strain R13 were closely related to Arthrobacter sp.,Staphylococcus sp., and Bacillus sp., respectively. In an attempt to identify their roles in biological nitrate and nitrite removal from sewage, we investigated their specific denitrification rates (SDNRs) for $NO_-^3$ - and $NO_-^2$ - in various cultures. All purecultures of each isolated nirS-harboring bacterial strain could remove $NO_-^3$ - and $NO_-^2$ - simultaneously in high efficiency, and the carbon requirements for $NO_-^3$ - removal of strain N6 and strain R13 were effectively low at 3.1 and 4.1 g COD/g $NO_3N$, respectively. In the case of mix-cultures of the strains (N6+N23, N6+R13, N23+R13, and N6+N23+R13), their SDNRs for $NO_-^3$ - were also effective, and their carbon requirements for $NO_-^3$ - removal were also effective at 3.0- 3.8 g COD/g NO3N. However, all tested mix-cultures accumulated $NO_-^2$ - in their culture media. On the other hand, the continuous culture of activated sludge mixed with strain N6 showed no significant increase of $NO_-^3$ - removal in comparison with strain N6's pure culture. These results suggest that nitrate and nitrite removal in biological wastewater treatment might be dependent on complicated bacterial interactions, including several effective denitrifying bacteria isolated in this study, rather than the specific bacterial types present and the number of bacterial types in activated sludge.

Performance Evaluation of Advanced Municipal Wastewater Treatment by Advanced Phase Isolation Ditch (APID) Process (Advanced Phase Isolation Ditch 공정에 의한 하수 고도처리 성능평가)

  • An, Sang-Woo;Kwak, Sung-Keun;Yoon, Yung-Han;Chung, Mu-Keun;Park, Jae-Roh;Park, Jae-Woo
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.5
    • /
    • pp.618-625
    • /
    • 2008
  • Advanced Phase Isolation Ditch (APID) process was studied to develop economic retrofitting technology, for the plants where retrofitting of common activated sludge process is required. In this study, to evaluate the effluent BOD, SS, T-N, and T-P concentrations as process capable and stable parameters for treating municipal wastewater, a demonstration plant was installed and operated in the existing sewage treatment plant of P city. During this study, the average effluent BOD, SS, T-N, and T-P concentrations were 4.56, 5.20, 9.30, and 1.75 mg/L at the conventional mode and 3.95, 3.17, 7.65, and 1.18 mg/L at the modified mode. The modified mode (BOD: 3.69, SS: 3.19, T-N: 1.27, and T-P: 0.69) increased the process capability more than the conventional mode (BOD: 1.80, SS: 1.05, T-N: 2.17, and T-P: 0.15) in this study. If process capability over 1.0, this process is capable and stable to treat wastewater. Therefore, newly developed APID process with modified intermittent aeration mode can be one of the useful processes for stable organic matter and nutrients removal.

Characteristics and Biological Kinetics of Nitrogen Removal in Wastewater using Anoxic-RBC Process (무산소-RBC 공정을 이용한 질소제거 특성 및 동력학적 인자 도출)

  • 최명섭;손인식
    • Journal of Environmental Science International
    • /
    • v.12 no.10
    • /
    • pp.1085-1093
    • /
    • 2003
  • This study was conducted to investigate anoxic-RBC (rotating biological contactor) and its application in advanced municipal wastewater treatment process to remove biologically organics and ammonia nitrogen. Effluent COD and nitrogen concentration increased as the increase of volumetric loading rate. But, the concentration changes of NO$_2$$\^$-/ -N and NO$_3$$\^$-/ -N were little, as compared to COD and NH$_4$$\^$+/ -N. When the volumetric loading rate increased, COD removal efficiency and nitrification appeared very high as 96.7∼98.8% and 92.5∼98.8%, respectively. However, denitrification rate decreased to 76.2∼88.0%. These results showed that the change of volumetric loading rate affected to the denitrification rate more than COD removal efficiency or nitrification rate. The surface loading rates applied to RBC were 0.13~6.0lg COD/㎡-day and 0.312∼1.677g NH$_4$$\^$+/-N㎡-day and they were increased as the increase of volumetric loading rate. However, the nitrification rate showed higher than 90%. The thickness of the biofilm in RBC was 0.130 ∼0.141mm and the density of biofilm was 79.62∼83.78mg/㎤. They were increased as surface loading rate increased. From batch kinetic tests, the k$\_$maxH/ and k$\_$maxN/ were obtained as 1.586 g C/g VSS-day, and 0.276 g N/g VSS-day, respectively. Kinetic constants of denitrifer in anoxic reactor, Y, k$\_$e/, K$\_$s/, and k were 0.678 mg VSS/mg N, 0.0032 day$\^$-1/, 29.0 mg N/l , and 0.108 day$\^$-l/, respectively. P and K$\_$s/, values of nitrification and organics removal in RBC were 0.556 g N/㎡-day and 18.71 g COD/㎡-day, respectively.

Increased Microbial Resistance to Toxic Wastewater by Sludge Granulation In Upflow Anaerobic Sludge Blanket Reactor

  • Bae, Jin-Woo;Rhee, Sung-Keun;Kim, In S.;Hyun, Seung-Hoon;Lee, Sung-Taik
    • Journal of Microbiology and Biotechnology
    • /
    • v.12 no.6
    • /
    • pp.901-908
    • /
    • 2002
  • The relationship between the layered structure of granules in UASB reactors and microbial resistance to toxicity was investigated using disintegrated granules. When no toxic materials were added to the media, the intact and disintegrated granules exhibited almost the same ability to decrease COD and to produce methane. However, when metal ions and organic toxic chemicals were added to a synthetic wastewater, he intact granules were found to be more resistant to toxicity than the disintegrated granules, as determined by the methane production. The difference in resistance between the intact and disintegrated granules was maximal, with toxicant concentrations ranging from 0.5 mM to 2 mM for trichloroethylene with toluene and 5 mM to 20 mM for metal ions (copper, nickel, zinc. chromium, and cadmium ions). The augmented COD removal rate by granulation compared to disintegrated granules was also measured in the treatment of synthetic and real wastewaters; synthetic wastewater, $-2.6\%$; municipal wastewater, $2.8\%$; swine wastewater, $6.4\%$; food wastewater, $25.0\%$; dye works wastewater, $42.9\%$; and landfill leachate, $61.8\%$. Continuous reactor operation also demonstrated that the granules in the UASB reactor were helpful in treating toxic wastewater, such as landfill leachate.

Chemical Treatment of Municipal Wastewater Using Alum Sludge

  • Shin, Dae-Yewn;Moon, Ok-Ran;Yoon, Mi-Ran;Ro, Chang-Wha;Kang, Gong-Unn;Moon, Deok-Hyn;Dermatas, Dimitris
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2005.12a
    • /
    • pp.51-53
    • /
    • 2005
  • Disposal of waterwork sludge is important problem in WTP(water treatment plant). Purpose of this study is treated municipal waste water chemically using sludge that is produced in waterwork plant by link to reutilize waterwork sludge. Municipal waste water that use in an experiment used is produced at C university, and is SS 220 mg/L, BOD 145 mg/L, COD 160 mg/L, T-N 52 mg/L and T-P 2.6 mg/L. Used Alum, polymer coagulant and coagulant aid (diatomite, powered activated carbon) as CaO, coagulant as alkaline aid by chemical treatment medicine. In case of does slow speed agitation and stations after pours waterwork sludge in sewage and alkaline aid and coagulant at rapidly mixing the colloidal creation speed is fast and fine colloids concentration was high but settling time is shortened a little and removal rate of pollutant improved by $60{\sim}99%$.

  • PDF

Analysis of Ocean Discharges of Municipal Water and its Near-Field Mixing Characteristics (도시 하수의 해양방류 및 근역혼합특성 분석)

  • 김강민;김지연;이중우
    • Journal of Korean Port Research
    • /
    • v.14 no.2
    • /
    • pp.241-249
    • /
    • 2000
  • The amount of municipal water has been increased rapidly up to now and it is necessary to treat and dispose the wastewater effectively. The recent trend of the effluent disposal system, after treatment, show a nearshore discharge which has an outfall with length somewhere between the shoreline discharge and an extended deepwater outfall. There is no universal solution to municipal water treatment and disposal and each case must be examined on its merits and on economic, technical and environmental bases. In this study we focused mostly on the scientific and engineering aspects of ocean disposal through the outfall. For this purpose, we made an investigation to the near-field characteristics of discharged water and made some comparison with the existing experimental results. We also applied it to the Pusan Jungang Effluent Outfall System, which is planned to build in the Gamchun harbour and will be completed in 2011. The model output showed the trajectoral variation of dilution and mixing behavior for three cases of outfall system. Dilution differences have been simulated and found the highest dilution condition under the different displacement of outfall system. On the basis of these outputs it will be proposed the optimum outfall system type and location.

  • PDF

A Study on the Removal of Nitrogen and Phosphorus of Municipal Wastewater with Biological Coated Media (미생물 코팅 담체를 이용한 하수의 질소$\cdot$인 제거에 관한 연구)

  • Kim Young-Gyu;Cho Il-Hyoung
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.1 s.88
    • /
    • pp.27-35
    • /
    • 2006
  • This study was carried out to investigate the removal of nitrogen and phosphorus in municipal sewage depending on existence of biological coated media in BCM reactor. The reactor with biological coated media is the process combining $A_2/O$ process. The removal efficiencies for $COD_{Mn},\; BOD_5,\;SS$, T-N and T-P were $78\%,\;90.5\%,\;92.3\%,\;61.9\%,\;60.2\%$, respectively. The specific nitrification rate$(mgNO_3-N/gMLSS{\cdot}d)$ of Contact aeration basin was 52.2 and the specific denitrification rate$(mgNO_3N/gMLSS{\cdot}d)$ in anoxic basin was 95.1. Also, phosphorus release$(mgPO_4-P/gMLSS{\cdot}d)$ in Anaerobic basin was 71.8 and Phosphorus uptake$(mgPO_4-P/gMLSS{\cdot}d)$ in contact aeration was 27.1.

Utilization of aerobic granulation to mitigate membrane fouling in MBRs

  • Iorhemen, Oliver T.;Hamza, Rania A.;Tay, Joo Hwa
    • Membrane and Water Treatment
    • /
    • v.8 no.5
    • /
    • pp.395-409
    • /
    • 2017
  • Membrane bioreactor (MBR) is a compact and efficient wastewater treatment and reclamation technology; but, it is limited by membrane fouling. The control of membrane fouling significantly increases operational and maintenance costs. Bacteria and their byproducts - extracellular polymeric substances (EPS) - are major contributors to membrane fouling in MBRs. A recent attempt at fouling mitigation is the development of aerobic granular sludge membrane bioreactor (AGMBR) through the integration of a novel biotechnology - aerobic granulation - and MBR. This paper provides an overview on the development of AGMBR to mitigate membrane fouling caused by bacteria and EPS. In AGMBR, EPS are used up in granule formation; and, the rigid structure of granules provides a surface for bacteria to attach to rather than the membrane surface. Preliminary research on AGMBR using synthetic wastewater show remarkable membrane fouling reduction compared to conventional MBR, thus improved membrane filtration. Enhanced performance in AGMBR using actual municipal wastewater at pilot-scale has also been reported. Therefore, further research is needed to determine AGMBR optimal operational conditions to enhance granule stability in long-term operations and in full-scale applications.

The Investigation of COD Treatment and Energy Consumption of Urban Wastewater by a Continuous Electrocoagulation System

  • DEDE SAGSOZ, Yesim;YILMAZ, Alper Erdem;EKMEKYAPAR TORUN, Fatma;KOCADAGISTAN, Beyhan;KUL, Sinan
    • Journal of Electrochemical Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.261-268
    • /
    • 2022
  • In this study, electrochemical treatment of urban wastewater with electrical conductivity of 1000 μS cm-1 and chemical oxygen demand of 250 mg L-1 was investigated using the variables of initial pH value, current density and flow rate. Electrocoagulation was used, in which aluminum and stainless steel were selected, as the electrochemical treatment process. The electrocoagulation process was operated in continuous mode. The data obtained in experimental studies show that the best COD removal efficiency occurred in experiments where the initial pH value was 6. The increase in current density from 5 A to 15 A decreased the removal efficiency from 79 to 67%. The increase in flow rate under constant current density also reduced the efficiency of removal as expected. In experiments in which current density and flow rate were examined together, the increase in flow rate allowed the application of higher current densities. This situation led to considerable reductions in energy consumption values, even if the COD removal efficiency did not significantly increase. The high COD removal obtained with the use of high flow rate and high current density indicates that the electrocoagulation process can be used for high flow rate municipal wastewater treatment.