• Title/Summary/Keyword: Municipal waste incinerator

Search Result 96, Processing Time 0.026 seconds

Determination of PCDD/F in Working Clothes of a Municipal Waste Incineration (생활폐기물 소각장 작업복 샘플의 다이옥신 분석)

  • 박순자;신정화;신정숙;정명희;안윤경
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.28 no.2
    • /
    • pp.354-363
    • /
    • 2004
  • PCDD/F (Polychlorinated dibenzo-p-dioxins and dibenzofurans) in both of treated fabric and untreated fabric for working clothes of a municipal waste incineration were determinated. The treated fabric for working clothes was developed for less exposure of PCDD/F in municipal waste incinerations. The total concentrations of PCDD/F in some parts such as surface, middle layer, inside for treated and untreated fabric were investigated. The I-TEQ value of surface was 0.23370ng TEQ/g for treated fabric, 0.15355ng $.$ TEQ/g for non-treated fabric. On the other hand, the value of middle layer was 0.00077ng $.$ TEQ/g, 0.00177ng $.$ TEQ/g, respectively. The surface of the treated fabric containing high levels PCDD/F was caused by absorption of them. Therefore, PCDD/F of the treated fabric in middle layer was less I-TEQ value than that of the untreated fabric. The treated fabric makes effect on preventing PCDD/F from permeating into human body.

DIOXIN LEVELS IN BLOOD OF RESIDENTS AND INCINERATOR WORKERS IN URBAN AREA OF KOREA

  • Yang, Jiyeon;Lim, Youngook;Jang, Yoonseok;Shin, Dongchun
    • Proceedings of the Korea Society of Environmental Toocicology Conference
    • /
    • 2003.10a
    • /
    • pp.153-153
    • /
    • 2003
  • In Korea, the number of municipal and hazardous waste incinerators have been increasing since the 1980s. In addition, municipal waste incinerators (MWI) are almost always located in residential areas. Therefore, the human health risk caused by dioxin has become a growing public concern in Korea. In this report, we describe the results of study in which serum levels of PCDDs/PCDFs in a group of workers at the MWI were compared to those in a comparison group of community residents who had never worked at the MWI.

  • PDF

Demonstration of a Modular Electrostatic Precipitator to Control Particulate Emissions from a Small Municipal Waste Incinerator

  • Intra, Panich;Yawootti, Artit;Tippayawong, Nakorn
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.239-246
    • /
    • 2014
  • Incineration is conceptually sound as a waste treatment technology. There is, however, concern over its emissions when it is improperly designed and operated. An electrostatic precipitator is one of the most commonly used devices to control particulate emissions from boilers, incinerators and some other industrial processes. In this work, a modular electrostatic precipitator with sizing of $1m{\times}1m{\times}1m$ was developed for removal of particulate matter from the exhaust gases of a small waste incinerator. Its design was based on a simple wire-and-plate concept. The corona discharge wires were connected to a positive high-voltage pulse generator, while the collection plates were grounded. The high-voltage pulse generator was used to produce the corona discharge field between the individual discharge wire and the collection plate. The particulate-laden exhaust gas flow was directed across the corona discharge field. The charged particles were deflected outward and collected on the plate. The collection efficiency was evaluated as a mass loading ratio between the difference at the inlet and the outlet to the particulate loading at the inlet of the precipitator. The collection efficiency of this modular electrostatic precipitator design was approximately 80 %.

Characteristics and Sampling of Dioxins/Furans from Emission Gas and Fly Ash Produced in Municipal Waste Incinerator (도시 소각로 쓰레기 소각후 생성된 폐가스 및 비산재중에 포함된 다이옥신류의 측정 및 특성고찰)

  • Lim, Chae-Hyun;Kim, Hee-Taik;Sohn, Jung-Hyun;Chang, Yoon-Seok
    • Applied Chemistry for Engineering
    • /
    • v.8 no.5
    • /
    • pp.790-795
    • /
    • 1997
  • Polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofuransfurans are the archetype of toxic chemicals. So it has absorbed public attention. The majors primary sources of PCDDS and PCDFs are chemical, thermal and photochemical reactions. Municipal solid waste incinerator facilities has been reported as the major contributors of dioxins to the environment. In this paper, Dioxins and furans were examined emission gas and fly ash produced during combustion in municipal solid waste incinerator. More effective method for sampling, extraction was described. The sample was extracted using a soxhlet method and purified using silicagel, alumina and carbon fibre HPLC to remove interfering compound. The extract was then analyzed by HRGC/HRMS. The result of this study showed recovery standard was good and the data resembled those of thermal processes. Total dioxins and furans were $1076.20pg/Nm^3$ and $1452.34pg/Nm^3$ respectively. The amount of highly chlorinated compound was more than that of lowly chlorinated compound. The 2,3,7,8-substituted TCDD was Just 0.34% of the total dioxins/furans amount.

  • PDF

A Study about Recycling from Municipal Solid Waste Incineration Bottom Ash (생활폐기물(生活廢棄物) 소각(燒却)바닥재의 재활용(再活用)을 위한 연구(硏究))

  • Ahn, Ji-Whan;Oh, Myung-Hwan;Han, Choon
    • Resources Recycling
    • /
    • v.17 no.1
    • /
    • pp.3-11
    • /
    • 2008
  • The treatment of domestic municipal solid waste has inclined to incineration process instead of disposal in landfills. So, the amount of ash generated by incineration of municipal solid waste is gradually increased. The incineration ash divides into bottom ash and fly ash. The bottom ash which accounts for about 90% of the incineration ash consists of ceramics, glasses and metals. And it can be used as the recycling product by the stabilization process. For example, the bottom ash is used as secondary building material or for other similar purposes such as road sub-bases and noise barrier in USA, Europe and Japan. But, the stabilization-treatment technique of bottom ash sti11leaves much to be desired in Korea. Thus, the domestic study of recycling about bottom ash must be improved through investigation about the chemical property and technique of stabilization.

Properties of Chemically Activated MSWI(Municipal Solid Waste Incinerator) Mortar (도시 폐기물 소각재를 이용한 화학적 활성화 모르타르의 특성)

  • Jo, Byung-Wan;Kim, Kwang-Il;Park, Jong-Chil;Park, Seung-Kook
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.5 s.95
    • /
    • pp.589-594
    • /
    • 2006
  • The recycling of industrial wastes in the concrete manufacturing is of increasing interest worldwide, due to the high environmental impact of the cement and concrete industries and to the rising demand of infrastructures, both in industrialized and developing countries. The production of municipal wastes in the South Korea is estimated at about 49,902 ton per day and only 14.5% of these are incinerated and principally disposed of in landfill. These quantities will increase considerably with the growth of municipal waste production, the progressive closing of landfill, so the disposal of municipal solid waste incinerator(MSWI) ashes has become a continuous and significant issue facing society, both environmentally and economically. MSWI ash is the residue from waste combustion processes at temperature between $850^{\circ}C\;and\;1,000^{\circ}C$. And the main components of MSWI ash are $SiO_2,\;CaO\;and\;Al_2O_3$. The aim of this study is to find a way to useful application of MSWI ash(after treatment) as a structural material and to investigates the hydraulic activity, compressive strength development composition variation of such alkali-activated MSWI ashes concrete. And it was found that early cement hydration, followed by the breakdown and dissolving of the MSWI-ashes, enhanced the formation of calcium silicate hydrates(C-S-H). The XRD and SEM-EDS results indicate that, both the hydration degree and strength development are closely connected with a curing condition and a alkali-activator. Compressive strengths with values in the 40.5 MPa were obtained after curing the activated MSWI ashes with NaOH+water glass at $90^{\circ}C$.

A Numerical Study for Effective Operation of MSW Incinerator for Waste of High Heating Value by the Addition of Moisture Air (함습공기를 이용한 고발열량 도시폐기물 소각로의 효율적 운전을 위한 수치 해석적 연구)

  • Shin, Mi-Soo;Shin, Na-Ra;Jang, Dong-Soon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.2
    • /
    • pp.115-123
    • /
    • 2013
  • Stoker type incinerator is one of the most popular one used as municipal solid waste (MSW) incineration because, in general, it is quite suitable for large capacity and need no preprocessing facility. Nowadays, however, since the combustible portion of incoming MSW increases together with the decrease of the moisture content due to prohibition of directly burying food waste in landfill, the heating value of waste is remarkably increasing in comparison with the early stage of incinerator installation. Consequently, the increased heating value in incinerator operation causes a number of serious problems such as reduction of waste amount to be burned due to the boiler heat capacity together with the significant NO generation in high temperature environment. Therefore, in this study, a series of numerical simulation have been made as parameters of waste amount and the fraction of moisture in air stream in order to investigate optimal operating condition for the resolution of the problems associated with the high heating value of waste mentioned above. In specific, a detailed turbulent reaction flow field calculation with NO model was made for the full scale incinerator of D city. To this end, the injection method of moisturized air as oxidizer was intensively reviewed by the addition of moisture water amount from 10% and 20%. The calculation result, in general, showed that the reduction of maximum flame temperature appears consistently due to the combined effects of the increased specific heat of combustion air and vaporization heat by the addition of water moisture. As a consequence, the generation of NOx concentration was substantially reduced. Further, for the case of 20% moisture amount stream, the afterburner region is quite appropriate in temperature range for the operation of SNCR. This suggests the SNCR facility can be considered for reoperation. which is not in service at all due to the increased heating value of MSW.

Leaching of Heavy Metal Ions in Mortar Using Municipal Waste Incinerator (소각재 사용 모르타르중의 중금속 이온 용출에 대한 연구)

  • Moon, Dae-Joong;Lim, Nam-Woong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.564-567
    • /
    • 2004
  • FAs and BAs indicated different chemical compositions and physical properties. Leaching of Pb in FAl and Cu in FA2 were 33.2mg/L and 5.92mg/L, these were high concentration above 30 and 2 times respectively in compared to permit level. Leaching of Hg and Cr were about 1/2 of permit level. When diatom was complexly mixed with portland cement, the 28 days compressive strength of mortar with FA2 was similar with that of control mortar. Furtherfore, leaching of heavy metal ions like as Pb, Cu, Hg, Cr was highly reduced.

  • PDF

도시고형폐기물 소각비산재의 Electrokinetic 정화

  • 조용실;한상재;김수삼
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2001.09a
    • /
    • pp.224-227
    • /
    • 2001
  • In general, municipal solid waste incinerator fly ash (MSWIF) has a potential hazardous leaching of heavy metal with subsurface environment variation. Therefore, to remove the heavy metal from MSWIF electrokinetic technology were used. With constant current density condition heavy metals in MSWIF removed by ion migration. During 7 days operation 40~80% of Cr, Cd and As were removed and longer operation, 14 days treatment, showed 35~100% removal efficiency.

  • PDF

Combustion characteristics for low emission of municipal waste incinerator with thermal flow simulation (열유동 해석을 통한 도시폐기물 소각로 저공해 연소 특성)

  • 전영남;송형운
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2001.11a
    • /
    • pp.97-98
    • /
    • 2001
  • 폐기물 소각로는 주입 폐기물의 성상이 균일하지 못하므로 폐기물의 불완전 연소에 의한 유해중간 생성물들이 생성되므로 논란이 되어왔다. 이를 제어하기 위해서는 공기량, 공기 주입방법, 공기 예열온도등에 운전조건들의 선정이 매우 중요하다. 이를 위해 진행되어온 연구는 크게 실험적 방법과 수치 해석적 방법의 두 범주로 나뉘어진다. 이에 본 연구에서는 수치해석적 방법으로 광주 상무신도심에 설치 가동중인 200톤/일 용량의 소각로내의 열유동 현상을 해석하기 위하여 고체 폐기물이 매우 빠르게 탈휘(devolatilization)되는 것으로 가정, 메탄가스로 단순화(Chen et al, 1999)하였다. (중략)

  • PDF