• Title/Summary/Keyword: Municipal facility

Search Result 74, Processing Time 0.034 seconds

A Study on the new MBT management system with variations of MSW's seasonal emission characteristics (생활폐기물의 계절별 성상변화에 따른 MBT 시스템 관리에 관한 연구)

  • Min, Byong-Hoon;Chung, Chan-Kyo;Kim, Jong-Moon;Min, Dul-le;Lim, Seung-Bin;Lee, Chae-Young;Kim, Hyung-Jin
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.18 no.4
    • /
    • pp.54-63
    • /
    • 2010
  • When MBT(Mechanical Biological Treatment) facility is designed, the management system adequate for domestic circumstance in Korea has been insufficient and power plant's load on seasonal variation has not been resolved yet. Thus, this study introduced MBT facility and MSW(Municipal Solid Waste)'s seasonal emission characteristics were investigated in order to establish new MBT management system. and additional thermal buffer-materials's calorific values were also considered to reduce the power plant's load. The results showed that the screening efficiency of MBT facility and the physical characteristics of each waste can be identified, and the calorific value by seasonal variation for MBT facility can be kept constant all the year round by using an additional thermal buffer-materials.

Characterization of Odorous Elements from Emission Sources in Chungju (충주시 악취발생원으로부터 배출되는 악취원인물질 특성 분석)

  • Cho, Byung-Yeol;Jo, Young-Min
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.4
    • /
    • pp.415-422
    • /
    • 2008
  • The emission characteristics of odorous compounds discharged from the major environmental treatment facilities in Chungju were closely investigated by an ammonia passive sampler and by analyzing a questionnaire of the public complains. Amongst the four major emission sources, the manure treatment facility showed the highest concentration. The major components were sulfur compounds including H$_2$S, tri-methyl amine, and aldehydes. The foodwaste treatment processes releases sulfur compounds and aldehydes. Municipal waste water treatment facility emits a high concentration of acetaldehyde. It was found that the perceived odor level depends on the meteorological condition, and the odor intensity was higher at midnight than daytime.

A Study by Proposal of Efficiency Increase for a Full-scale Wastewater Reclamation Facility using a Biofilter Packed with Granular Sulfur (하수처리수 재이용을 위한 실규모 입상황 생물막여과 시설의 효율증대 방안에 관한 연구)

  • Moon, Jin-Young;Hwang, Yong-Woo;Baek, Seung-Ryun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.1
    • /
    • pp.73-83
    • /
    • 2010
  • This study was performed to increase the removal efficiency of the biofilter packed with granular sulfur in municipal wastewater reclamation facility. Constituent units were influent water tank, denitrification tank, BOD reduction tank and outlet. And, the major operation factor is a biofilter packed with submerged granular sulfur. Actual wastewater and synthetic wastewater were used as influent wastewater. Experimental condition was divided into two phases according to the amount of a phosphorus coagulant. Total phosphorus removal efficiency was insignificant at mode I that phosphorus coagulant was not injected. The average influent and effluent total phosphorus concentrations at mode II were 0.5 ~ 1.0 mg/L and 0.27 mg/L, respectively. As for COD and BOD effluent concentrations, COD was 3.0 mg/L and BOD was 1.0 mg/L. Additionally, nitrogen removal rates were high at low influent DO concentration. In conclusion, a new process, biofilter packed with granular sulfur is expected to treat high-rate nitrogen wastewater and expected to be utilized as an alternative of technological innovation for the nitrogen treatment.

Issuing Municipal Bonds to Pay Compensation for Lands and Selecting Compensation Priority Areas for Urban Parks and Greenbelts unexecuted in the Long-Term - With a Focus on Seoul City - (장기미집행 도시공원 및 녹지 보상재원 마련을 위한 지방채 발행과 보상우선지역 선정 - 서울특별시를 대상으로 -)

  • Kim, Yu-Ri
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.45 no.3
    • /
    • pp.92-106
    • /
    • 2017
  • This paper examines the validity of issuing municipal bonds for land compensation of long-term unexecuted urban parks and greenbelts. Then it suggests that municipal bonds should be issued for compensation priority areas with high rising prices. By conducting correlation analysis and PLS(Partial Least Squares) regression for 32 long-term unexecuted urban parks and greenbelts, the factors were identified that affected 'rising prices of IAPLP(Individually Announced Public Land Price) after seven years'. According to the analysis results, Variable Importance in the Projection in PLS regression was higher in 'IAPLP of base year(1.919)' and 'Accumulated rising Rates of average IAPLP in the borough(1.176).' The implications of this study are as follows. In Seoul, the accumulated rising rates of average IAPLP over the past 12 years is higher than the accumulated interest rates for seven years of urban planning facility bonds, which means that IAPLP have risen more than the interest payments due to the issuance of municipal bonds. In addition, since the actual compensation is three times that of IAPLP, it is judged that the land price is actually much higher than the interest payments. This shows that issuing municipal bonds and preferentially compensating for areas like high rising land prices can increase the economic efficiency of the budget execution. Also, for economic efficiency of budget execution, it is necessary to propose an 'area with high IAPLP' or 'a part in the borough with high rising rate of average IAPLP,' which is expected to have a high rising land price as criteria for compensation priority areas. In the future, when issuing municipal bonds to compensate long-term unexecuted urban parks and greenbelts, variousresearch on financing for municipal bonds repayment should be conducted.

Evaluation on Resource Recovery Potential by Landfill Gas Production (매립가스 발생량에 따른 자원화 가능성 평가)

  • Lee, Hae-Seung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.10
    • /
    • pp.4679-4688
    • /
    • 2011
  • This study was performed to the municipal waste generation amounts and characteristics for B city in Gangwon province, predicted the methane gas generation rate emitted from landfill, and analyzed the possibility of energy recovery to RDF(Refuse Derived Fuel) using combustible waste. The study results showed that the average bulk density of municipal waste for B city was 144.0 kg/$m^3$, and the average ratios of combustible waste were 36.0 % of paper, 21.6 % of vinyl, and 19.7 % of food waste. respectively. In the experiment for heating value, high and low heating value(moisture) was measured to 3,471 $kca{\ell}$/kg and 2,941 $kca{\ell}$/kg, respectively. After the prohibition of burying of food waste in landfill, the heating value of municipal waste was dramatically increased due to increase of the ratio of paper, vinyl, and plastic waste. The prediction results of methane gas generation rate emitted from landfill showed that the gas generation rate is increasing to 2,505.7 CH4 ton/year in 2021. After then, the rate is decreasing gradually. When the RDF facility is installed, the rate is decreasing after peaking at 1,956.9 CH4 ton/year in 2013. The generation rate of LFG emitted from waste landfill of B city was analyzed to 9.92 $m^3$/min, similar to 10.11 $m^3$/min for other city.

A Clinical Observation on Childhood Shigellosis Occurred in Mass Outbreak (소아에서 집단 발병한 세균성 이질의 임상적 고찰)

  • Lee, Soo-Jin;Yu, Young;Kim, Sin-Na
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.5 no.1
    • /
    • pp.33-38
    • /
    • 2002
  • Purpose: The incidence of shigellosis had been decreased due to the use of antibiotics and the improvement of environmental sanitation but recently increases again. Shigellosis occurrs in mass outbreak through unsanitized meal preperation refered from welfare facility and school. We observed epidemic aspect and clinical coarse of childhood shigellosis. Methods: from December 2001 to January 2002, 22 inpatients with shigellosis in Dongbu Municipal Hospital were observed epidemiologically, clinically and microbiologically. Results: 1. The sexual ratio was 1:1 and mean age was $5.5{\pm}1.4$ years (14 months to 11 years). 2. The clinical manifestations were following: diarrhea (95.5%), high feve (10%) and asymptomatic (4.5%). The mean duration was $3.9{\pm}2.1$ days (1 to 12 days). All patients had no complication and normal serologic test. 3. S. sonnei was cultured in rectal swab, and was resistant to TMP/SMX and ampicillin, but susceptible to ampicillin/sulbactam and the 3rd generation cephalosporins. 4. The patients were treated by antibiotics with conservative treatment including electrolytes and fluid therapy for 5 days, resulting in improvement confirmed by negative reaction on stool culture. 5. These cases were all occurred in mass outbreak in day care center and were suspected to be secondary infection by members of family. Conclusion: This shigellosis occurred in day care center was secondary infection due to S. sonnei and had mild clinical coarse and improvement after antibiotic treatment.

  • PDF

A Case Study on the Establishment of Assessment Standards for the Site Selection of Waste Treatment Facility (폐기물 처리시설 입지선정 평가기준 설정에 관한 사례연구)

  • Jung, Jong-Gwan;Jang, Won
    • Journal of Environmental Impact Assessment
    • /
    • v.6 no.2
    • /
    • pp.137-152
    • /
    • 1997
  • The siting process of municipal solid waste treatment facility consists of a structured set of policies that guide the implementation of waste management goals. The main problems of siting process are the social and political context or the community opposition. During the past, the traditional siting process has been obsolete in most pans of the country, so public officials and researchers have tried to experiment with new policies and procedures. A number of controversial issues offer insight into the factors that are related to the local residents opposition to new waste treatment facilities. The purpose of this case study focused on the establishment of criteria in the site selection of waste treatment facilities which can carry out resources recovery. incineration and landfill simultaneously. That is to say. the main points are to make concrete the quantification standards of assignment and take an objective allotment scale according to the assessment factors. The summarized results are as follows; 1. To promote the site selection based on the guideline such as rational. objective and due process of law, it is desirable to inform the local residents the methods of assessment in advance. 2. Totally 20 factors for the site selection are divided into 3 categories such as living environment characteristics, technological location characteristics and socio-economic factors. And the supposed magnitude of weight in all items are equally applied. 3. In regard to 20 assessment factors, the allotment of point is distributed by the specific location characteristics. Namely to make the assessment easily, each factors are set the scale from 1 to 5 points en masse along the data which are acquired in the region.

  • PDF

Assessment for geothermal energy utilization in the riverbank filtration facility (강변여과수 시설에서의 지열에너지 활용 가능성 평가)

  • Shin, Ji-Youn;Kim, Kyung-Ho;Bae, Gwang-Ok;Lee, Kang-Kun;Jung, Woo-Sung;Suk, Hee-Jun;Kim, Hyeong-Su
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.485-488
    • /
    • 2007
  • Riverbank filtration is a kind of artificial aquifer recharge for the fresh water supply. By construction of several production wells penetrating the riverbank, surface water withdrawn from the river would pass riverbed. This extracted water is well known to be cooler than surface water in summer and warmer than surface water in winter, showing more constant water temperature. This characteristic of extracted water is applied to geothermal energy utilization. Prediction of the annual temperature variation of filtrated water is the major concern in this study. In Daesan-myeon, Changwon-si, Gyeongsangnam-do, South Korea, riverbank filtration facility has been on its operation for municipal water supply and thermal energy utilization since 2006. Appropriate hydraulic and thermal properties were estimated for flow and heat transfer modeling with given pumping rate and location. With the calibrated material properties and boundary conditions, we numerically reproduced measured head and temperature variation with acceptable error range. In the numerical simulation, the change of saturation ratio and river stage caused by rainfall was calculated and the resulting variation of thermal capacity and thermal conductivity was considered. Simulated temperature profiles can be used to assess the possible efficiency of geothermal energy utilization using riverbank filtration facility. Influence of pumping rate, pumping location on the extracted water temperature will be studied.

  • PDF

A study on the management-maintenance system in urban park (도시공원의 관리체계에 관한 연구)

  • 김동필;이기철
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.23 no.4
    • /
    • pp.1-11
    • /
    • 1996
  • The purpose of this study was to suggest the more efficient system for management in urban park through the investigation of the managemental condition. Research sites for managemental condition were 9 municipal park managemental offices in Seoul, Pusan and Taegu. The degree of the managemental state in these parks was generally passive and low. So, each of them had to consider the ways how to buy private-owned sites, to standardize facility maintenance, to characterize the managemental objects, to enlarge managemental personnels and systems, to apply entrusting management, to plan user-service strategies and to shorten expenditures. Particularly the positive managemental improvement in user control was demanded to cope with the changing social needs. In long term, they had to develop basic elements for the reasonable park management, clear park maps, area of facilities, the event, citizen participation, budgets and etc., and had to prepare the middle-long term management plan and the precise analysis to the managemental criteria.

  • PDF

Development of Eco Burner Ash Melting Furnace System

  • Sekiguchi, Yoshitoshi;Hamabe, Kohei;Momoda, Shigeru
    • Proceedings of the Korean Institute of Resources Recycling Conference
    • /
    • 2001.05b
    • /
    • pp.19-22
    • /
    • 2001
  • In recent years, the creation of waste recycling society has been required to cope with the traditional ways of waste treatments. In accordance with the package recycling law in force, calls for the developments of new waste treatment techniques suitable for 21st century are growing higher. A new ash melting furnace system named Eco Burner Ash Melting Furnace System has been developed. It is a burner type ash melting system in which the fluffs made of the plastics segregated from municipal solid wastes are directly fired at high temperature in the furnace. This system provides an economical ash melting system because plastic wastes or paper scraps that have heretofore been considered hard to recycle are used in compensation for fossil fuel. In this paper, we describe the ash melting test results obtained from a substantiative facility.

  • PDF