• Title/Summary/Keyword: Municipal Wastewater Treatment Plant

검색결과 98건 처리시간 0.027초

고형(固形) 폐기물(廢棄物)내의 생물학적(生物學的)으로 분해불능(分解不能)한 유기물질(有機物質)의 함량(含量)의 결정(決定)에 관한 연구(研究) (Methods of Determination of Nonbiodegradable Organic Contents in Solid Wastes)

  • 최의소
    • 대한토목학회논문집
    • /
    • 제8권3호
    • /
    • pp.113-118
    • /
    • 1988
  • 도시하수(都市下水) 처리시설(處理施設)로부터 생산(生産)되는 1차(次)와 2차(次) 슬러지의 생물학적(生物學的) 분해불능정도(分解不能程度)를 실험실(實驗室) 호기성(好氣性)과 혐기성(嫌氣性) 소화조(消化槽)를 운전(運轉)시켜 비교(比較)하였다. 1차(次) 슬러지의 분해불능(分解不能) 함량(含量)은 45~47%, 2차(次) 슬러지는 58~68%로 나타났으며 최대(最大) $CH_4$ 가스 생산량(生産量)은 kgVS제거(除去)당 1차(次)의 경우(境遇)에는 $0.76m^3$, 2차(次)의 경우(境遇)는 $0.54m^3$ 이었다. 1차(次)와 2차(次)슬러지의 소화(消化)가스 내(內)의 $CH_4$ 함량(含量)은 63%와 65%였다.

  • PDF

하수처리장 혐기성 소화조 상징액의 아질산화 반응 연구 (Nitritation of Anaerobic Digester Supernatant from Sludge Processing in MWTP)

  • 길경익
    • 한국물환경학회지
    • /
    • 제22권3호
    • /
    • pp.540-545
    • /
    • 2006
  • The anaerobic digester supernatant (ADS) with high $NH_4-N$ concentration often results in a $NH_4-N$ overloading to the mainstream process of municipal wastewater treatment plant (MWTP). The nitrogen removal from the ADS is therefore important in order to achieve a stable mainstream process performance as well as to prevent $NH_4-N$ overloading due to ADS. Recently because of several advantages compared to the full nitrification, many works have shown interests in controlling the build-up of $NO_2-N$ in nitritation processes. The application of nitritation could save the aeration power compared to the full nitrification processes. In addition, the denitrification of $NO_2-N$ could reduce organic carbon requirements compared to the $NO_3-N$ denitrification. The purpose of this research was to find out the characteristics of the ADS nitritation and $NO_2-N$ accumulating factors from the laboratory reactor study. As a result based on the long-term laboratory experiment, it can be concluded that the degree of nitritation was closely related with the availability of alkalinity, free ammonia (FA), solid retention time (SRT) and solid concentration in the nitritation reactor.

대체관개 용수에 의한 배추생육 및 토양 염류도에 미치는 영향 (Influences of Chinese Cabbage Growth and Soil Salinity to Alternative Irrigation Waters)

  • 신중두;박상원;김원일;이종식;윤순강;엄기철
    • 한국토양비료학회지
    • /
    • 제40권1호
    • /
    • pp.25-30
    • /
    • 2007
  • 갈수기에 관개한 대체용수가 배추 생육 및 토양 염류도에 미치는 영향을 구명하기 위해 대체관개용수로 산업공장 폐수처리장 방류수, 하수종말처리장 방류수와 대조구로서 지하수를 관개하여 본 실험을 수행하였다. 관개한 대체용수에 대한 화학구성 성분은 산업공장 폐수처리장 방류수의 $Ni^+$ 농도와 SAR 값은 관개수로서 다른 국가의 재활용 기준치를 상회하였다. 또한 하수종말처리장 방류수의 CODcr 농도는 농업관개용수 재활용 기준을 초과하는 것으로 나타났다. ECi 값은 산업공장 폐수처리장 및 하수종말처리장 방류수가 0.7에서 $2.0dS\;m^{-1}$로서 약한 염류도에 속하였다. 산업공장 폐수처리장 및 하수종말처리장 방류수 관개구의 평균 수확지수는 관개기간에 관계없이 대조구 0.61에 비교하여, 각각 0.64과 0.63으로 나타났다. 토양중의 SAR값은 결구기에 관개기간이 지연됨에 따라 증가하였지만, 산업공장 폐수처리장 방류수 관개구에 대해서는 수확기에 30일간 관개한 것을 제외하고는 큰 차이를 보이지 않았다. 그러나, 하수종말처리장 방류수를 관개한 경우 대조구와 비교하여 전생육기간을 통해 관개기간에 따른 큰 차이는 없었다. 수확기에 산업공장 폐수처리장 및 하수종말처리장 방류수 관개구의 평균 ECe는 대조구 $0.013dS\;m^{-1}$에 비교하여 각각 $0.017dS\;m^{-1}$$0.036dS\;m^{-1}$이었다. 대체용수를 관개한 후 수확기의 토양 중 $NH_4-N$ 농도는 관개기간에 따른 대체용수원 별로는 큰 차이가 없는 것으로 관측되었다. 또한, 토양 중의 $NO_3-N$ 농도는 관개 후 20일까지는 증가하였지만, 결구기에 하수종말처리장 방류수 관개 후 30일에는 감소하였다. 하수종말 처리장 방류수를 관개한 표토층(0 15 cm)의 $Ni^+$ 함량은 결구기에 관개기간이 지연됨에 따라 증가하였지만, 수확기에 급격히 감소하여 모든 처리구에서 일정 수준을 유지하였다. 그러므로, 배추경작 시 갈수기에 배추정식 후 20일간 하수종말 처리장 방류수를 20일간 관개하여도 안전한 것으로 사료된다.

하수처리시설에서 배양 가능한 공기중 미생물의 분포 및 특성 (Distribution and Characteristics of Culturable Airborne Bacteria and Fungi in Municipal Wastewater Treatment Plants)

  • 박교남;고지윤;정춘수;김종설
    • 미생물학회지
    • /
    • 제47권1호
    • /
    • pp.38-49
    • /
    • 2011
  • 하수처리시설에서 발생하는 공기중 미생물은 작업자 및 주민에게 건강상 위해의 요인이 될 수 있다. 이들 시설에서 공기중 세균과 진균의 농도 수준을 파악하기 위해 울산시에 위치한 위생처리장 1곳(YC-STP)과 하수처리장 3곳(YY-, OS-, HY-STP)의 포기조와 포기조 근처 지점에서 계절별로 공기중 미생물을 포집하였다. YC-STP의 공기중 세균 농도는 포기조에서 $1.3({\pm}0.2){\times}10^3-2.6({\pm}1.1){\times}10^4$ MPN/$m^3$, 포기조 근처에서 $1.7 ({\pm}1.0){\times}10^2-7.2({\pm}2.2){\times}10^3$ MPN/$m^3$로 매우 높았으며, 대장균군도 검출되었다. YY-, OS-, HY-STP의 공기중 세균 농도는 포기조에서 $1.9({\pm}1.2){\times}10^1-1.8({\pm}1.2){\times}10^4$ MPN/$m^3$, 포기조 근처에서 $5.0({\pm}2.8){\times}10^0-6.6({\pm}2.0){\times}10^3$ MPN/$m^3$의 범위였다. YC-, OS-, YY-STP에서의 공기중 세균 농도는 대조군 지점에 비해 평균값 기준으로 포기조에서는 16-1,200배, 포기조 근처에서는 9-280배 정도 더 높은 수치였으며, 포기조 근처(10 m)보다 포기조(0 m)에서 1.7-4.4배 정도 더 높았다. 공기중 세균을 분리하여 동정한 결과 하수처리시설에서는 Pseudomonas luteola, 대조군 지점에서는 Micrococcus sp.가 우점하였다. 공기중 진균의 농도는 포기조 보다 포기조 근처에서 더 높았으며 포기조 외에 다른 주요 발생원이 존재함을 시사한다. Cladosporium, Alternaria, Penicillium의 3속이 주로 검출되었다.

마산ㆍ창원 하수종말 처리장의 해양방류 처리수에 대한 초기ㆍ근역 희석연구(II) (Initial and Near-field Dilution at the Ocean Outfall of Masan-Changwon Municipal Wastewater Treatment Plant(II))

  • 강시환;유승협;오병철;박광순
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제3권1호
    • /
    • pp.35-44
    • /
    • 2000
  • 1999년 2월에 관측한 수온 및 염분도 분포로부터 마산ㆍ창원 하수종말처리장의 해양 수중방류수에 대한 동계의 근역희석률을 산정하였다. 소조기의 약한 주변유속과 수온약층에 의해 하수플륨이 포착되어 희석률이 30~40정도로 저조했던 하계의 경우와는 달리 동계 소조기의 경우에는 주변해수의 수직적 등밀도혼합이 전 층에서 형성되어 하수플륨이 수표면까지 상승하며 희석률도 90~130정도로 훨씬 큰 것으로 나타났다. CORMIX2 모형의 모의결과에서도 소조기의 약한 유속(Ua=6.0cm/s)의 경우 동계 희석률이 하계 희석률보다 약 3배 정도 증가하였으며 대조기의 강한 유속(Ua=15.5cm/s)의 경우에는 두 계절의 희석률 차이가 30%정도로 미미하였다. 이는 수중방류 하수의 근역희석 및 혼합과정이 주변해수의 밀도성층 효과보다는 유동성분에 더 큰 영향을 받기 때문인 것으로 사료된다.

  • PDF

ASBR(Anaerobic Sequencing Batch Reactor) 공정의 F/R비가 암모니아가 탈기된 축산폐수의 유기물 제거에 미치는 영향 (Effect of F/R ratio of ASBR (Anaerobic Sequencing Batch Reactor) Process on Removal of the Organic Matters in Ammonia Stripped Swine Wastewater)

  • 황규대;조영무
    • 한국물환경학회지
    • /
    • 제21권6호
    • /
    • pp.687-694
    • /
    • 2005
  • Lab-scale experiments have been carried out to investigate the effect of F/R ratio of ASBR (Anaerobic Sequencing Batch Reactor) process on the removal of the organic matters in ammonia stripped swine wastewater. Three ASBR inoculated with sludge mixed with granular sludge of UASB (Upflow Anaerobic Sludge Blanket) and anaerobic digested sludge of municipal wastewater treatment plant were operated. Ammonia stripped swine wastewater was used as influent. Prior to conducting the experiments with varied conditions, the effect of increasing organic loading rate from 2.34 to $5.79gTCOD_{Cr}/L$-day at a fixed F/R ratio of 0.1 on the organic removal efficiency has been studied during start-up period. As the result of the experiment, under the condition of varied organic loadings, less than $4.14gTCOD_{Cr}/L$-day, the removed efficiency $TCOD_{Cr}$ of the ASBR process is 83% resulted from the mean value of effluent $TCOD_{Cr}$, 9,125 mg/L during the start-up period. Then ASBRs were operated with F/R ratio of 0.024, 0.303 and 0.91 respectively. Organic loading rate was increased from 4.56 to $15.43gTCOD_{Cr}/L$-day to investigate the effects of F/R ratio and organic loading rate on the organic removal efficiency. As the result of the experiment, less than $6.23gTCOD_{Cr}/L$/L-day, F/R ratio haven't an effect on the organic removal efficiency and the mean removal efficiency of TSS, $TCOD_{Cr}$ and $SCOD_{Cr}$ was about 80%, 86% and 78% at the all of F/R ratio. But as organic loading rate was increased from 8.54 to $12.04gTCOD_{Cr}/L$-day at the F/R ratio of 0.024, the removal efficiency of $SCOD_{Cr}$ decreased from 71% to 63%. The range of decreased removal efficiency of $SCOD_{Cr}$ at the F/R ratio of 0.024 was much more higher than at the F/R ratio of 0.303, 0.91. Thus, as organic loading rate was increased, ASBRs were operated with high F/R ratio to obtain high removal efficiency.

전처리 방법에 따른 하수처리장 유입수에서의 미세플라스틱 성상분석 평가 (Evaluation of microplastic in the inflow of municipal wastewater treatment plant according to pretreatment methods)

  • 김성렬;길경익
    • 한국습지학회지
    • /
    • 제24권2호
    • /
    • pp.83-92
    • /
    • 2022
  • 전세계적으로 플라스틱에 대한 수요가 늘어감에 따라 플라스틱 폐기물의 양이 증가하고 있다. 수계 내에서의 미세플라스틱의 위해성에 대한 평가 기준에 대해서는 아직 많은 연구가 필요하지만 대체적으로 미세플라스틱을 성질 개선을 위해 첨가하는 화학물이 유독하다는 사실은 여러 문헌을 통해 증명되어있다. 하수처리장(MWTP)은 오수를 처리하는 시설로서 가정에서 발생하는 미세플라스틱이 모이는 미세플라스틱이 모이는 장소이다. 따라서 MWTP 에서의 미세플라스틱 분석이 필요한 상황이지만 이를 진행하기 위해 표준화된 방법이 아직은 없다. 따라서 본 연구에서는 MWTP에서 미세플라스틱 검출을 위한 하수 시료에 적용할 수 있는 최적의 방법론을 조사해보고자 한다. 본 연구에서는 J 하수 처리장에서 수집한 유입수 샘플로부터 미세플라스틱을 분석하는 다양한 전처리 방법 중에서 하수처리장 샘플에 가장 널리 사용되는 펜톤산화와 H2O2 산화법을 선정하였다. 각 전처리 방법별로 측정에 오차를 발생시킬 요소들이 있었으며, 이를 극복하기 위해 펜톤산화 전처리의 경우 밀도분리법 대신 여과를 진행하여 분석을 진행하는 것이 추천되며, H2O2 산화법의 경우 반응 이후 증류수로 세척하는 과정이 필요해 보인다. 분석 결과 미세플라스틱의 농도는 H2O2 산화법을 이용한 샘플의 경우 2.75 ea/L, 펜톤산화법을 이용한 샘플의 경우 3.2 ea/L 로 측정되었으며 대부분 섬유형태로 존재하였다. 또한 정량분석을 현미경을 이용해 육안으로 진행하기 때문에 측정 결과에 대한 신뢰성을 보장하기가 어렵다고 판단해 검정곡선을 만들었다. 총 3개의 검정곡선이 그려졌으며 해당 검정곡선들을 분석한 결과 R2 값이 전부 0.9 이상이였으며 이는 정량분석에 대해 높은 신뢰성을 보장한다. 정성분석으로 MWTP에 유입되는 미세플라스틱의 계열에 대해선 판단할 수 있었지만 각 미세플라스틱의 화학적인 조성에 대해선 확인할 수 없었다. 향후 MWTP에 유입되는 미세플라스틱의 화학적 조성에 대해서 확인하기 위해서 이번 연구를 활용할 수 있을 것이다.

APID공정 내 공정진단을 위한 dynamic $\bar{x}$-R 관리도의 적용 (Application of Dynamic $\bar{x}$-R Control Chart for Advanced Phase Isolation Ditch (APID) Process)

  • 안상우;곽성근;정영욱;정무근;박재우
    • 한국물환경학회지
    • /
    • 제25권5호
    • /
    • pp.704-712
    • /
    • 2009
  • Advanced Phase Isolation Ditch (APID) process was studied to develop economic retrofitting technology, for the plants where retrofitting of common activated sludge process is required. In this study, to evaluate and monitor the effluent water quality ($BOD_5$, SS, T-N, and T-P) and operating conditions (Influent, SVI, SRT, and HRT) as process capable and stable parameters for treating municipal wastewater, a demonstration plant was installed and operated in the existing sewage treatment plant of P city. During this study, the average effluent $BOD_5$, SS, T-N, and T-P concentrations were 7.7, 5.6, 10.8, and 1.6 mg/L. Trend analysis of influent $BOD_5$, SS, T-N, and T-P in APID process were illustrated that APID process need for more strong APID process management on the winter session, such as developing new intermediated aeration mode, operating methods, and managements strategy. At the application of control chart, the signal of uncommon effects at APID process was determined much higher existing control chart tntr conventional control chart in this study. These results indicate that conventional control chart has been collected and determined cleary signal at only stable situation. Therefore, newly developed APID process of dynamic control chart can be one of the useful tool for monitoring and management process.

상온 조건에서 혐기 소화 상징액을 이용한 아질산화 반응과 운전 인자의 상관성 분석 (Correlation between operation factors and nitritation using anaerobic digester supernatant at ordinary temperature)

  • 임지열;길경익
    • 한국습지학회지
    • /
    • 제18권3호
    • /
    • pp.244-249
    • /
    • 2016
  • 혐기 소화 상징액은 고농도 질소를 함유하고 있으며 수처리 계통으로 반송되어 하수처리장 유입 부하를 증가시킨다. 혐기 소화 상징액 내 고농도 질소를 아질산화 반응을 통해 처리하게 된다면, 경제적인 하수처리장 개조 효과를 기대할 수 있다. 본 연구에서는 혐기 소화 상징액을 이용한 장기간 실험실 규모 반응조 운전을 실시하였다. 운전 결과 암모니아성 질소 제거율 90% 이상과 아질산화율 70% 이상 효율을 보이는 운전 조건을 도출할 수 있었다. 또한 이를 바탕으로 운전 인자와 암모니아성 질소 제거 효율 및 아질산화율의 상관성을 분석하였다. 운전 결과 암모니아성 질소 제거 효율과 아질산화율은 미생물 체류시간 (SRT), 암모니아성 질소 부하 및 단위 미생물 농도 (MLSS) 당 암모니아성 질소부하와 관계가 큰 것을 확인할 수 있었다. 본 연구 결과는 향후 혐기 소화 상징액의 아질산화 반응 유도에 중요 자료로 활용될 수 있으며, 아질산화 반응의 활용성을 증가시킬 것을 기대한다.

다양한 온도 조건에서 아질산화 반응 유도 - 혐기 소화 상징액을 대상으로 (Nitritation at Various Temperature Conditions - Using Anaerobic Digester Supernatant)

  • 길경익;임지열
    • 한국방재학회 논문집
    • /
    • 제11권3호
    • /
    • pp.237-243
    • /
    • 2011
  • 강화되는 방류수 수질기준에 맞추어 하수처리장 개조 방안의 하나로 고농도의 암모니아성 질소를 함유한 반류수를 처리하는 방안이 주장되고 있다. $35^{\circ}C$, $20^{\circ}C$$10^{\circ}C$ 조건의 실험실 규모 반응조 운전을 통하여 경제적인 질소 제거 방법인 아질산화 반응 유도하였다. $20^{\circ}C$ 이상의 온도에서는 안정적인 아질산화 반응을 유도 할 수 있었으나, $10^{\circ}C$ 저온 조건에서는 완전 질산화 반응이 유도 되었다. 이는 온도의 영향을 받아 SRT가 길어져 완전 질산화 반응이 유도된 것으로 사료된다. 온도에 따라 아질산화 반응에 요구되는 SRT가 변화하는 것으로 볼 때, 온도와 SRT는 아질산화 반응에 중요한 인자로 판단된다. 또한 $20^{\circ}C$ 이상의 조건에서 암모니아성 질소 제거 반응과 아질산화 반응을 유도하는 것이 유리 한 것으로 나타났다. 본 논문에서 제시한 결과는 아질산화 반응을하수처리장에 적용할 때 중요한 기초 자료로 사용될 수 있을 것이다.