• Title/Summary/Keyword: Multiplex House

Search Result 12, Processing Time 0.029 seconds

Green Building Design Strategies for Multiplex Housing

  • Park, Won Ho;Ahn, Yong Han;Choi, Young-Oh
    • KIEAE Journal
    • /
    • v.16 no.4
    • /
    • pp.21-30
    • /
    • 2016
  • Purpose: Energy saving in the built facilities is getting important due to energy crisis. The Korea government has been implemented several energy and green building policies and practices. The both of government and industry also developed green building strategies ant technologies to reduce energy consumption and carbon emission. The purpose of this research is to identify applicable green building strategies and technologies for that can be cost effective and applicable to a multiplex house. Method: This research identified appropriate green building strategies from analysing green building strategies from G-SEED certified apartment projects and popular green building strategies. This study also adopted a survey research method to find out the applicable green building strategies for a multiplex housing. In addition, this research also conduct cost estimating to identify initial cost premium of green building strategies. Results: The research outcomes in this study guide a building owner to know about initial cost premiums of green building strategies and technologies and an architect and contractor to identify appropriate and cost effective green building strategies that can be applicable to a multiplex house.

Supportive House Plan for Home-based Business;focused on businessman of online shopping mall (주거공간의 재택근무 지원 계획;온라인 쇼핑몰 사업가를 중심으로)

  • Yoon, Nam-Kyung;Kwon, Oh-Jung
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2006.11a
    • /
    • pp.396-400
    • /
    • 2006
  • Because of rapid growth of economy and development of the communication technology of modem society, office space's shape and business contents are highly diversified. And these changes made a new working style, homeworkers who work in their house. For increasing homeworker's working efficiency, it needs a space plan which can coexist home's original functions and business functions. The purpose of this study was designed a multiplex house used a co-operative house's concept which based on the data which collected by man to man case research about operators of online shopping malls.

  • PDF

Development of In-House Multiplex Real Time PCR for Human Papillomavirus Genotyping in Iranian Women with Cervical Cancer and Cervical Intraepithelial Neoplasia

  • Sohrabi, Amir;Mirab-Samiee, Siamak;Modarressi, Mohammad Hossein;Izadimood, Narge;Azadmanesh, Kayhan;Rahnamaye-Farzami, Marjan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.15
    • /
    • pp.6257-6261
    • /
    • 2014
  • Background: HPV related cervical cancer as one of the most common women cancers in developing countries. Regarding accessibility of commercial vaccines, any long or short term modality for integrating preventive immunization against HPV in a national program needs comprehensive information about HPV prevalence and its genotypes. The important role of selecting most accurate diagnostic technologies for obtaining relevant data is underlined by different assays proposed in the literature. The main objective of the present study was to introduce an in-house HPV typing assay using multiplex real time PCR with reliable results and affordable cost for molecular epidemiology surveys and diagnosis. MATERIALS AND METHODS: 112 samples of formalin fixed paraffin embedded tissues and liquid based cytology specimens from patients with known different grades of cervical dysplasia and invasive cancer, were examined by this method and the result were verified by WHO HPV LabNet proficiency program in 2013. RESULTS: HPV was detected in 105 (93.7%) out of 112 samples. The dominant types were HPV 18 (61.6%) and HPV 16 (42.9%). Among the mixed genotypes, HPV 16 and 18 in combination were seen in 12.4% of specimens. CONCLUSIONS: According to acceptable performance, easy access to primers, probes and other consumables, affordable cost per test, this method can be used as a diagnostic assay in molecular laboratories and for further planning of cervical carcinoma prevention programs.

Compact battery-less guest guidance system at the EXPO 2005, Aichi Japan

  • Itoh, Hideo;Lin, Xin;Kaji, Ryosaku;Niwa, Tatsuya;Nakamura, Yoshiyuki;Nishimura, Takuichi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2207-2210
    • /
    • 2005
  • Guest guidance system based on the compact battery-less information terminal, Aimulet, which has been developed by the authors of the National Institute of Advanced Industrial Science and Technology (AIST), Japan. Conventional Aimulet, which is Aimulet ver.1 or CoBIT, has features of location and direction sensitive information service device without batteries. On the other hand, the Aimulet has two subjects, one is multiplex and demultiplex of some contents, and the other is operation under sunshine. Former subject is of solved by the wavelength multiplex technique using LED emitter with different wavelength and dielectric optical filters. Latter subject is solved by new micro spherical solar cells with a visible-light-eliminating optical filter and a new design of light irradiation. These techniques are applied to the EXPO 2005, Aichi Japan and introduced in public. Aimulet GH is Former technique is applied on Aimulet GH, which is used in Orange Hall of the Global House, scientific museum with a fossil of a frozen mammoth.

  • PDF

A Multiplex Housing Energy Conservation Strategy through Combining Insulation Standard Based Green Roof Systems and Passive Design Elements

  • Son, Hyeongmin;Park, Dong Yoon;Chang, Seongju
    • KIEAE Journal
    • /
    • v.14 no.1
    • /
    • pp.31-38
    • /
    • 2014
  • Recently, the coverage of urban forests has been rapidly decreasing as the cities are created and expanding. Consequently, there arise urban problems such as heat island effect, urban flooding, urban desertification and so on. In this context, green roof systems is considered to be an efficient alternative to deal with these problems. However, it is difficult to apply green roof to new buildings since the majority of the buildings in cities are already constructed and the demand for new building constructions is not high enough. Therefore, it should be considered to apply green roof system to existing buildings for resolving various problems. This study evaluates heating and cooling energy consumption based on the combination of passive design factors such as wall, roof, window insulation in addition to a green roof system applied to an existing house by using an energy simulation program. Total 8 potential improvement cases are developed. Each case is applied to the same house with different insulation standard for simulations. Through the analysis of the simulated cases with the chosen test house, it is confirmed that heating energy consumption decreases as improvement cases are applied, but cooling energy consumption is relatively not much affected by each improvement case. In addition, when each improvement case is applied to already highly insulated house, the effect of thermal energy improvement decreases while the same improvement that is applied to the case with low insulated house tends to yield higher improvement rate.

Evaluating Spatiality of Green-House Gas Emission in Building Site ("대" 지목에 의거한 온실가스 분포의 공간성 평가)

  • Kim, Jun-Hyun;Um, Jung-Sup
    • Proceedings of the Korean Association of Geographic Inforamtion Studies Conference
    • /
    • 2010.06a
    • /
    • pp.94-102
    • /
    • 2010
  • These days the land category is the most specific basis of legal for land use or land use form that is determined by the main use of land. Even if same land building site, it is used very various like a detached house, a row house, a multiplex house, a villa, an apartment, a mixed-use Apartments, commercial building, fallow land etc. There is a need of variety analysis in order to apply greenhouse gas emission or statistics assessment for standard of classification. Therefore, This study measured carbon dioxide by for different government agencies of maps by land use time, season, elevation, space, area of floating population. As a result, The emission characteristic was high l.78 times, on average of l.35 times in winter compared with summer, when the temperatures increased 11C, the carbon dioxide is 22ppm high in the afternoon, A commercial building is high 4.04 times compare with detached house.

  • PDF

The Relationship between Indoor Air Pollutants and Pulmonary Function in Asthmatic Children with Mold Sensitization (곰팡이에 감작된 소아 천식 환자 가정내 환경유해물질 농도와 폐기능의 상관관계)

  • Yoon, Wonsuck;Lim, Jaehoon;Park, Sang Hyun;Lee, Mingyu;Yoo, Young
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.6
    • /
    • pp.685-693
    • /
    • 2020
  • Objectives: Recent data indicate that sensitization to mold contributes to the severity and persistence of asthma. The aim of this study was to investigate relationships between indoor mold concentrations and pulmonary function parameters in asthmatic children with mold sensitization. Methods: Asthmatic subjects who had a positive result in skin-prick testing to more than one mold allergen, such as Alternaria, Aspergillus, or Penicillium, were enrolled. Their pulmonary function and methacholine challenge test results were collected. Measurements of blood eosinophil, serum IgE, and fractional exhaled nitric oxide (FeNO) were taken. Indoor levels of VOC, CO2, PM10 and PM2.5 in each subject's house were measured. We counted mold and bacteria colonies from the subjects' house air samples. Results: The mean levels of FEV1, FVC, FEV1/FVC, and FEF25-75 were 82.8±19.7, 87.3±17.9, 85.8±8.3, and 82.3±28.9%, respectively. The mean FeNO level was 19.8±11.2 ppb and the geometric mean (range of one SD) of methacholine PC20 was 3.99 mg/mL (0.67-23.74 mg/mL). The average indoor air pollutant levels were below the recommended levels set by the Ministry of Environment for multiplex buildings. Indoor mold levels showed a significant inverse correlation with methacholine PC20, but not with the baseline pulmonary function parameters. Conclusion: Indoor mold concentrations are a risk factor for increased bronchial hyperresponsiveness among asthmatic children with mold sensitization. Targeted environmental intervention should be considered for selected asthmatic children with mold sensitization for avoiding severe airway hyperresponsiveness.

A Study on Improvement Direction for Construction Environment of Small Houses -Focused on Expert Group- (소형주택의 건설 프로세스 개선방향에 관한 연구 -전문가 집단을 중심으로-)

  • Ha, Jun-Geun;Yoo, Seok-Hyung
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.7
    • /
    • pp.388-400
    • /
    • 2018
  • Small houses are continuously supplied after the alleviated housing act enacted in 2009. This study aimed to conduct a survey among an expert group associated with small house construction, propose problems by discovering difficulties and vulnerable points small and medium-sized construction companies experience while launching construction works as well as factors that impede the safety and housing environment of small houses. Furthermore, it ultimately intends to propose improvements. First, low-priced order is a major cause of unreasonable contract. Most companies were found to have low-priced orders in order to manage order performance. Low bidding and low-priced order are implemented to maintain construction businesses, ultimately threatening the safety environment of buildings. In addition, it is assumed that moderate bid periods and construction periods should be guaranteed. Second, work standardization for small and medium-sized companies is needed due to numerous cases that failed to meet order process. Additionally, regular instruction is required as many employees are not fully aware of relevant contents. Third, the most urgent policy direction turned out avoidance of low-priced bidding and removing insolvent enterprises from the market. Small and medium-sized construction companies that primarily build small houses undergo poor work condition. Therefore, the safety environment of small houses should be enhanced through work standardization and avoiding low-priced order.

C13orf18 and C1orf166 (MULAN) DNA Genes Methylation are Not Associated with Cervical Cancer and Precancerous Lesions of Human Papillomavirus Genotypes in Iranian Women

  • Sohrabi, Amir;Mirab-Samiee, Siamak;Rahnamaye-Farzami, Marjan;Rafizadeh, Mitra;Akhavan, Setareh;Hashemi-Bahremani, Mohammad;Modarressi, Mohammad Hossein
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.16
    • /
    • pp.6745-6748
    • /
    • 2014
  • Background: Nowadays, molecular biomarkers have critical roles for cancer diagnosis and prognosis in clinical laboratories. Human papillomaviruses are the main agents for etiology of cervical carcinoma. The present survey was conducted to evaluate the genes methylation in cervical cancer and precancerous lesions involvement with HPV genotypes. Materials and Methods: C13orf18 and C10rf166 (MULl or Mulan) DNA methylation as potential biomarkers and risk factors was investigated in 112 liquid based cytology and Formalin-Fixed Paraffin-Embedded tissue specimens in Iranian females with cervical intraepithelial neoplasia and dysplasia. Results: In this survey, HPV18 (61.6%) and HPV16 (42.9%) proved to be the most common HPV genotypes identified by In-House Multiplex Real Time PCR. There were no significant relationship between HPV positivity and the methylated DNA genes mentioned above (p>0.05). Conclusions: Our MethyLight data demonstrated that these genes could not be considered as specific, sensitive and suitable prognostic biomarkers in cervical dysplasia related HPV. It is suggested that further studies with more patients should be done on candidate methylated markers in different countries in order to plan for cervical cancer prevention.