• Title/Summary/Keyword: Multiple scattering analysis

Search Result 50, Processing Time 0.027 seconds

Electron Firehose Instabilities in High-β Intracluster Medium

  • Kim, Sunjung;Ha, Ji-Hoon;Ryu, Dongsu;Kang, Hyesung
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.2
    • /
    • pp.55.2-55.2
    • /
    • 2019
  • The firehose instability is driven by a pressure anisotropy in a magnetized plasma when the temperature along the magnetic field is higher than the perpendicular temperature. Such condition occurs commonly in astrophysical and space environments, for instance, when there are beams aligned with the background magnetic field. Recently, it was argued that, in weak quasi-perpendicular shocks in the high-β intracluster medium (ICM), shock-reflected electrons propagating upstream cause the temperature anisotropy. This electron temperature anisotropy can trigger the electron firehose instability (EFI), which excites oblique waves in the shock foot. Scattering of electrons by these waves enables multiple cycles of shock drift acceleration (SDA) in the preshock region, leading to the electron injection to diffusive shock acceleration (DSA). In the study, the kinetic properties of the EFI are examined by the linear stability analysis based on the kinetic Vlasov-Maxwell theory and then further investigated by 2D Particle-in-Cell (PIC) simulations, especially focusing on those in high-β (β~100) plasmas. We then discuss the basic properties of the firehose instability, and the implication of our work on electron acceleration in ICM shock.

  • PDF

Improvement of KOMPSAT-5 Image Resolution for Target Analysis (객체 분석을 위한 KOMPSAT-5 영상의 해상도 향상 성능 분석)

  • Lee, Seung-Jae;Chae, Tae-Byeong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.30 no.4
    • /
    • pp.275-281
    • /
    • 2019
  • A synthetic aperture radar(SAR) satellite is more effective than an optical satellite for target analysis because an SAR satellite can provide two-dimensional electromagnetic scattering distribution of a target during all-weather and day-and-night operations. To conduct target analysis while considering the earth observation interval of an SAR satellite, observing a specific area as wide as possible would be advantageous. However, wider the observation area, worse is the resolution of the associated SAR satellite image. Although conventional methods for improving the resolution of radar images can be employed for addressing this issue, few studies have been conducted for improving the resolution of SAR satellite images and analyzing the performance. Hence, in this study, the applicability of conventional methods to SAR satellite images is investigated. SAR target detection was first applied to Korea Multipurpose Satellite-5(KOMPSAT-5) SAR images provided by Korea Aerospace Research Institute for extracting target responses. Extrapolation, RELAX, and MUSIC algorithms were subsequently applied to the target responses for improving the resolution, and the corresponding performance was thereby analyzed.

Studies on Estimation of Fish Abundance Using an Echo Sounder ( 1 ) - Experimental Verification of the Theory for Estimating Fish Density- (어군탐지기에 의한 어군량 추정에 관한 기초적 연구 ( 1 ) - 어군량추정이론의 검증실험 -)

  • 이대재
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.27 no.1
    • /
    • pp.1-12
    • /
    • 1991
  • An experiment has been carefully designed and performed to verify the theory for the echointergration technique of estimating the density of fish school by the use of steel spheres in a laboratory tank. The spheres used to simulate a fish school were randomly distributed throughout the insonified volume to produce the acoustic echoes similar to those scattered from real fish schools. The backscattered echoes were measured as a function of target density at tow frequencies of 50kHz and 200kHz. Data acquisition, processing and analysis were performed by means of the microcomputer-based sonar-echo processor including a FFT analyzer. Acoustic scattering characteristics of a 36cm mackerel was investigated by measuring fish echoes with frequencies ranging from 47.8kHz to 52.0kHz. The fluctuation of bottom echoes caused by the effects of fish-school attenuation and multiple scattering which occurred in dense aggregations of fishes was also examined by analyzing the echograms of sardine schools obtained by a 50kHz telesounder in the set-net's bagnet, and the echograms obtained by a scientific echo sounder of 50kHz in the East China Sea, respectively. The results obtained can be summarized as follows: 1. The measured and the calculated echo shapes on the steel sphere used to simulate a fish school were in close agreement. 2. The waveform and amplitude of echo signals by a mackerel without swimbladder fluctuated irregularly with the measuring frequency. 3. When a collection of 30 targets/m super(3) lied the shadow region behind another collection of 5 targets/m super(3), the mean losses in echo energy for the 30 targets/m super(3) were about -0.4dB at 50kHz and about -0.2dB at 200kHz, respectively. 4. In the echograms obtained in the East China Sea, the bottom echoes fluctuated remarkably when the dense aggregations of fish appeared between transducer and seabed. Especially, in the case of the echograms of sardine school obtained in a set-net's bagnet, the disappearance of bottom echoes and the lengthening of the echo trace by fish aggregations were observed. Then the mean density of the sardine school was estimated as 36 fish/m super(3). It suggests that when the distribution density of fishes in oceans is greater than this density, the effects of fish-school attenuation and multiple scattering must be taken into account as a possible source of error in fish abundance estimates. 5. The relationship between mean backscattering strength (, dB) and target density ($\rho$, No./m super(3)) were expressed by the equations: =-46.2+13.7 Log($\rho$) at 50kHz and =-43.9+13.4 Log($\rho$) at 200kHz. 6. The difference between the experimentally derived number and the actual number of targets gradually decreased with an increase in the target density and was within 20% when the density was 30 targets/m super(3). From these results, we concluded that when the number of targets in the insonified volume is large, the validity of the echo-integration technique of estimating the density of fish schools could be expected.

  • PDF

Investigation of O4 Air Mass Factor Sensitivity to Aerosol Peak Height Using UV-VIS Hyperspectral Synthetic Radiance in Various Measurement Conditions (UV-VIS 초분광 위성센서 모의복사휘도를 활용한 다양한 관측환경에서의 에어로솔 유효고도에 대한 O4 대기질량인자 민감도 조사)

  • Choi, Wonei;Lee, Hanlim;Choi, Chuluong;Lee, Yangwon;Noh, Youngmin
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.2_1
    • /
    • pp.155-165
    • /
    • 2020
  • In this present study, the sensitivity of O4 Air Mass Factor (AMF) to Aerosol Peak Height (APH) has been investigated using radiative transfer model according to various parameters(wavelength (340 nm and 477 nm), aerosol type (smoke, dust, sulfate), aerosol optical depth (AOD), surface reflectance, solar zenith angle, and viewing zenith angle). In general, it was found that O4 AMF at 477 nm is more sensitive to APH than that at 340 nm and is stably retrieved with low spectral fitting error in Differential Optical Absorption Spectroscopy (DOAS) analysis. In high AOD condition, sensitivity of O4 AMF on APH tends to increase. O4 AMF at 340 nm decreased with increasing solar zenith angle. This dependency isthought to be induced by the decrease in length of the light path where O4 absorption occurs due to the shielding effect caused by Rayleigh and Mie scattering at high solar zenith angles above 40°. At 477 nm, as the solar zenith angle increased, multiple scattering caused by Rayleigh and Mie scattering partly leads to the increase of O4 AMF in nonlinear function. Based on synthetic radiance, APHs have been retrieved using O4 AMF. Additionally, the effect of AOD uncertainty on APH retrieval error has been investigated. Among three aerosol types, APH retrieval for sulfate type is found to have the largest APH retrieval error due to uncertainty of AOD. In the case of dust aerosol, it was found that the influence of AOD uncertainty is negligible. It indicates that aerosol types affect APH retrieval error since absorption scattering characteristics of each aerosol type are various.

Multi-layered Gap Measurement on In-Vessel Cerium Retention Using Ultrasonic Wave Reflective Pattern Analysis and Frequency Diversity Signal Processing (초음파 반사 패턴과 주파수 대역 분할 신호처리를 이용한 다층구조인 노내 간극 측정)

  • Koo, Kil-Mo;Sim, Cheul-Mu;Kim, Jong-Hwan;Kim, Sang-Baik;Kim, Hee-Dong;Park, Chi-Seung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.4
    • /
    • pp.314-321
    • /
    • 2000
  • A gap between a $Al_2O_3/Fe$ thermite and lower head vessel is formed in the lower-plenum arrested vessel attack(LAVA) experiment which is the 1st phase study of simulation of naturally arrested vessel attack in vessel(SONATA-IV). The gap measurement using a conventional ultrasonic method would be lack of a reliability due to the structure complexity and the metallurgical grain size change of the lower head HAZ occurred by a thermite $Al_2O_3/Fe$ melt or a $Al_2O_3$ melt at $2300^{\circ}C$. The grain echoes having false signals and lower S/N ratio signals are detected due to a multiple scattering, a mode conversion and an attenuation of a ultrasonic resulted from at the interface of increased grain size zone. In this test, the signals pattern was classified to understand the behavior of the ultrasonic in a multi-layer specimen of solid-liquid-solid of assuming that the thermite and the lower head vessel is immersed. The polarity threshold algorithm of frequency diversity gives us the enhancement about 6dB of the ratio S/N.

  • PDF

Non-invasive hematocrit measurement (혈액중 non-invasive hematocrit 분석)

  • Yoon, Gil-Won;Jeon, Kye-Jin;Park, Kun-Kook;Lee, Jong-Youn;Hwang, Hyun-Tae;Yeo, Hyung-Seok;Kim, Hong-Sig
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2002.11a
    • /
    • pp.59-62
    • /
    • 2002
  • Wavelength selection and prediction algorithm for determining hematocrit are investigated. A model based on the difference in optical density induced by the pulsation of heart beat is developed by taking approximation of Twersky's theory on the assumption that the variation of blood vessel size is small during arterial pulsing[1]. A device is constructed with a five-wavelength LED array as light source. The selected wavelengths are two isobestic points and three in compensation for tissue scattering. Data are collected from 549 out-patients who are randomly grouped as calibration and prediction sets. The range of percent hematocrit was 19.3∼51.8. The ratio of the variations of optical density between systole and diastole at two different wavelengths is used as a variable. We selected several such variables that show high reproducibility among all variables. Multiple linear regression analysis is made. The relative percent error is 8% and the standard deviation is 3.67 for the calibration set. The relative % error and standard deviation of the prediction set are 8.2% and 3.69 respectively. We successfully demonstrate the possibility of non-invasive hematocrit measurement, particularly, using the wavelengths below 1000nm.

  • PDF

Performance Analysis of DCMP and ZF based on Spatial Channel Response Estimation by ESPRIT (ESPRIT에 의한 공간 채널응답 추정치에 기초를 둔 방향구속 전력 최소화법과 제로포싱 알고리즘의 성능평가)

  • Jeong, Jung-Sik;Yim, Jeong-Bin;Ahn, Young-Sup
    • Journal of Navigation and Port Research
    • /
    • v.26 no.5
    • /
    • pp.543-548
    • /
    • 2002
  • It has been known that the DCMP(Directionally Constrained Minimization of Power) and the ZF(Zero Forcing) can improve the SINR performance of an array antenna system by using spatial signature of wireless channel. This paper analyzes the performance of DCMP and ZF in multiple scattering environments. To obtain the spatial signature of wireless channel. both DOA(Directional of Arrival) and AS(Angular spread) of the received signals were estimated by using ESPRIT. The performance of the DCMP and the ZF was analyzed theoretically. By computer simulation of SINR performance was evaluated.

Non-invasive Blood Glucose Detection Sensor System Based on Near-Infrared Spectroscopy (근적외선 분광법 기반 비침습식 혈당 검출 센서 시스템)

  • Kang, Young-Man;Han, Soon-Hee
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.5
    • /
    • pp.991-1000
    • /
    • 2021
  • Among non-invasive blood glucose detection technologies, the optical technique is a method that uses light reflection, absorption, and scattering characteristics when passing through a biological medium. It reduces pain or discomfort in measurement and has no risk of infection. So it is becoming a major flow of blood glucose detection research. Among them, near-infrared spectroscopy has a disadvantage in that the complexity increases when analyzing signals detected due to interferences between proteins and acids that share a similar absorption function with blood glucose molecules. In this study, a non-invasive sensor system with multiple near-infrared bands was designed and manufactured to alleviate the deterioration of blood glucose detection function that may occur due to skin absorption of near-infrared rays. A blood survey was conducted to verify the system, and the degree of blood glucose response in the blood was collected as spectral data, and the results of this study were quantitatively verified in terms of correlation between the data and blood glucose.

Simulation of Time-Domain Acoustic Wave Signals Backscattered from Underwater Targets (수중표적의 시간영역 음파 후방산란 신호 모의)

  • Kim, Kook-Hyun;Cho, Dae-Seung;Seong, Woo-Jae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.27 no.3
    • /
    • pp.140-148
    • /
    • 2008
  • In this study, a numerical method for a time-domain acoustic wave backscattering analysis is established based on a physical optics and a Fourier transform. The frequency responses of underwater targets are calculated based on physical optics derived from the Kirchhoff-Helmholtz integral equation by applying Kirchhoff approximation and the time-domain signals are simulated taking inverse fast Fourier transform to the obtained frequency responses. Particularly, the adaptive triangular beam method is introduced to calculate the areas impinged directly by acoustic incident wave and the virtual surface concept is adopted to consider the multiple reflection effect. The numerical analysis result for an acoustic plane wave field incident normally upon a square flat plate is coincident with the result by the analytic time-domain physical optics derived theoretically from a conventional physical optics. The numerical simulation result for a hemi-spherical end-capped cylinder model is compared with the measurement result, so that it is recognized that the presented method is valid when the specular reflection effect is predominant, but, for small targets, gives errors due to higher order scattering components. The numerical analysis of an idealized submarine shows that the established method is effectively applicable to large and complex-shaped underwater targets.

The Effects of Size Reduction and pH on Dispersion Characteristics of ATO (Antimony-Doped Tin Oxide) (입자 저감 및 pH가 ATO (안티몬도핑 산화주석)의 분산 특성에 미치는 영향)

  • Kim, Jin-Hoon;Jeong, Eui-Gyung;Lee, Sang-Hun;Han, Won-Hee;Lee, Young-Seak
    • Applied Chemistry for Engineering
    • /
    • v.21 no.3
    • /
    • pp.311-316
    • /
    • 2010
  • This study aimed to prepare antimony-doped tin oxide (ATO) dispersion with high stability. The methods to achieve this goal were sought by investigating the changes of ATO particle size, size distribution, dispersion property as wet ball milling treatment time increased. And the changes of wet ball milled ATO dispersion property were also investigated, as pH increased. The changes of ATO particle size and size distribution, according to wet ball milling treatment time were evaluated with laser diffraction particle size analyzer and scanning electron microscope (SEM). The changes of ATO dispersion property, as wet ball milling treatment time and pH increased, were evaluated with zeta potential analysis and Turbiscan. By 60 min wet ball milling treatment time, ATO particle size decreased and size distribution became narrower, as the treatment time increased. After 60 min milling, the ATO particle size decreased to less than 30% of the initial size and the size distribution was narrowed to $0.1{\sim}5{\mu}m$ from $1{\sim}35{\mu}m$. However, more than 60 min milling, ATO particles aggregated and the particle size increased. ATO dispersion stability also increased as the treatment time and pH increased because the reduced particle size increased particle surface energy and repulsion between particles and the increased pH enhanced particle surface ionization. Hence, after proper length of wet ball milling treatment, highly stable ATO dispersion can be prepared, as increasing pH of the dispersion.