• Title/Summary/Keyword: Multiple power sources

Search Result 139, Processing Time 0.023 seconds

A Flyback-Assisted Single-Sourced Photovoltaic Power Conditioning System Using an Asymmetric Cascaded Multilevel Inverter

  • Manoharan, Mohana Sundar;Ahmed, Ashraf;Park, Joung-Hu
    • Journal of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.2272-2283
    • /
    • 2016
  • This paper proposes a power conditioning system (PCS) for distributed photovoltaic (PV) applications using an asymmetric cascaded multilevel inverter with a single PV source. One of the main disadvantages of the cascaded multilevel inverters in PV systems is the requirement of multiple isolated DC sources. Using multiple PV strings leads to a compromise in either the voltage balance of individual H-bridge cells or the maximum power point tracking (MPPT) operation due to localized variations in atmospheric conditions. The proposed PCS uses a single PV source with a flyback DC-DC converter to facilitate a reduction of the required DC sources and to maintain the voltage balance during MPPT operation. The flyback converter is used to provide input for low-voltage H-bridge cells which processes only 20% of the total power. This helps to minimize the losses occurring in the proposed PCS. Furthermore, transient analyses and controller design for the proposed PCS in both the stand-alone mode and the grid-connection mode are presented. The feasibility of the proposed PCS and its control scheme have been tested using a 1kW hardware prototype and the obtained results are presented.

Locating of Partial Discharge (부분 방전의 위치 추정)

  • Lee, Seung-Hwan;Yu, Chi-Hyung;Chung, Chan-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1997.07b
    • /
    • pp.468-470
    • /
    • 1997
  • This paper presents an estimation method of the number of partial discharge(PD) sources and their locations in power transformer. To identify multiple PD sources and their locations, the directions-of-arrival estimation algorithm is employed. The results of simulations shows that the proposed method could be accurately detect the number of PD sources and their locations in power transformer.

  • PDF

The Effect of Power Sources of Department Store and Fashion Company, and Salesperson's Job Consciousness on Job Satisfaction in the Middle Management System of Department Store (백화점 중간관리 형태에서 백화점 및 패션업체의 권력원천과 판매원의 직업의식이 직무만족에 미치는 영향)

  • Lee, Hyun-Jin;Choo, Tae-Gue
    • Fashion & Textile Research Journal
    • /
    • v.14 no.2
    • /
    • pp.230-241
    • /
    • 2012
  • The purpose of this study was to examine the effect of power sources of department store and fashion company, and salesperson's job consciousness on job satisfaction in the middle management system of department store. Questionnaire data from 193 salespeople in the middle management of department store were analyzed by reliability analysis, factor analysis, correlation analysis, multiple regression analysis, hierarchical regression analysis. The results of this study were as follows: First, coercive power, informational and expert power, and referent power of department store had significant effects on job satisfaction. The coercive power of department store had a negative influence on job satisfaction, while informational and expert power, and referent power of department store had a positive influence on job satisfaction. Second, referent power, expert power, reward power, coercive power of fashion company had a positive influence on job satisfaction. Third, referent power of department store had a greater influence on job satisfaction than other power sources. Fourth, job commitment and pride, prospect awareness had a positive influence on job satisfaction, while professional self-awareness had no effect on job satisfaction.

Modeling and Regulator Design for Three-Input Power Systems with Decoupling Control

  • Li, Yan;Zheng, Trillion Q.;Zhao, Chuang;Chen, Jiayao
    • Journal of Power Electronics
    • /
    • v.12 no.6
    • /
    • pp.912-924
    • /
    • 2012
  • In hybrid renewable power systems, the use of a multiple-input dc/dc converter (MIC) leads to simpler circuit and lower cost, when compared to the conventional use of several single-input converters. This paper proposed a novel three-input buck/boost/buck-boost converter, which can be used in applications with various values of input voltage. The energy sources in this converter can deliver power to the load either simultaneously or individually in one switching period. The steady relationship, the power management strategy and the small-signal circuit model of this converter have been derived. With decoupling technology, modeling and regulator design can be obtained under multi-loop control modes. Finally, three generating methods of a multiple-input buck/boost/buck-boost converter is given, and this method can be extended to the other multiple-input dc/dc converters.

The Analysis of The Three Phase Rectifier (다중 3상 PWM 정류기의 해석)

  • Shin, D.H.;Youn, K.S.;Cho, J.G.;Kwon, W.H.
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.242-245
    • /
    • 1995
  • In this paper the multiple three rectifiers for the power factor correction are proposed, analyzed and designed. The multiple three phase rectifiers draw sinusoidal ac currents from the ac voltage sources with nearly unity input power factor and operate with PWM making the control circuit simple and system cost low. Outstandingly it reduces the rated power capacity of devices and the input filter size by reducing input current ripples. Moreover design rules can be obtained from input and output current equations. With the proposed rules, input power factor and output power capacity are determined approximately. Finally these design rules are verified with computer simulations.

  • PDF

An Experimental Study on Multiple ICP & Helicon Source for Oxidation in Semiconductor Process

  • Lee, Jin-Won;Na, Byoung-Keun;An, Sang-Hyuk;Chang, Hong-Young
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.271-271
    • /
    • 2012
  • Many studies have been investigated on high density plasma source (Electron Cyclotron Resonance, Inductively Coupled Plasma, Helicon plasma) for large area source after It is announced that productivity of plasma process depends on plasma density. In this presentation, we will propose the new concept of the multiple source, which consists of a parallel connection of ICP sources and helicon plasma sources. For plasma uniformity, equivalent power (especially, equivalent current in ICP & Helicon) should distribute on each source. We design power feeding line as coaxial transmission line with same length of ground line in each source for equivalent power distribution. And we confirm the equivalent power distribution with simulation and experimental result. Based on basic study, we develop the plasma source for oxidation in semiconductor process. we will discuss the relationship between the processing parameters (With or WithOut magnet, operating pressure, input power ). In ICP, plasma density uniformity is uniform. In ICP with magnet (or Helicon) plasma density is not uniform. As a result, new design (magnet arrangement and gas distributor and etc..) are needed for uniform plasma density in ICP with magnet and Helicon.

  • PDF

A Study on the Modeling and Analysis of the Micro-Grid (마이크로그리드의 모델링 및 해석에 관한 기초 연구)

  • Son, Kwang-M.;Lee, Kye-B.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.533-534
    • /
    • 2006
  • Micro-source units having power ratings in thousands of watts can provide power quality with higher reliability and efficiency than the conventional large scale units. This paper develops switching level model of micro-source and studies the characteristics of the micro-grid consisting of multiple micro-sources and interfaced with electric power system. The developed model adopts the space vector PWM to fully utilize the capacity of inverter. The interaction of the grid connected micro-sources and the characteristics of the control system parameters are investigated. Micro-sources and micro-grid are implemented using PSCAD/EMTDC. Simulation results show that the proposed model is efficient for studying micro-grid system.

  • PDF

Power System and Drive-Train for Omni-Directional Autonomous Mobile Robots with Multiple Energy Storage Units

  • Ghaderi, Ahmad;Nassiraei, Amir A.F;Sanada, Atsushi;Ishii, Kazuo;Godler, Ivan
    • Journal of Power Electronics
    • /
    • v.8 no.4
    • /
    • pp.291-300
    • /
    • 2008
  • In this paper power system and drive-train for omni-directional autonomous mobile robots with multiple energy storage units are presented. Because in proposed system, which is implemented in soccer robots, the ability of power flow control from of multiple separated energy storage units and speed control for each motor are combined, these robots can be derived by more than one power source. This capability, allow robot to diversify its energy source by employing hybrid power sources. In this research Lithium ion polymer batteries have been used for main and auxiliary energy storage units because of their high power and energy densities. And to protect them against deep discharge, over current and short circuit, a protection circuit was designed. The other parts of our robot power system are DC-DC converters and kicker circuit. The simulation and experimental results show proposed scheme and extracted equations are valid and energy management and speed control can be achieved properly using this method. The filed experiments show robot mobility functions to perform the requested motion is enough and it has a high maneuverability in the field.

The long-term mm/radio activity of active galactic nuclei

  • Trippe, Sascha
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.59.1-59.1
    • /
    • 2011
  • I present an analysis of the long-term evolution of the fluxes of six active galactic nuclei (AGN) - 0923+392, 3C 111, 3C 273, 3C 345, 3C 454.3, and 3C 84 - in the frequency range 80 - 267 GHz using archival calibration data of the IRAM Plateau de Bure Interferometer. Our dataset spans a long timeline of ~14 years with 974 - 3027 flux measurements per source. We find strong (factors ~2-8) flux variability on timescales of years for all sources. The flux density distributions of five out of six sources show clear signatures of bi- or even multimodality. Our sources show mostly steep (alpha~0.5-1), variable spectral indices that indicate outflow dominated emission; the variability is most probably due to optical depth variations. The power spectra globally correspond to red-noise spectra with five sources being located between the cases of white and flicker noise and one source (3C 111) being closer to the case of random walk noise. For three sources the low-frequency ends of their power spectra appear to be upscaled in spectral power by factors ~2-3 with respect to the overall powerlaws. We conclude that the source emission cannot be described by uniform stochastic emission processes; instead, a distinction of "quiescent" and (maybe multiple) "flare" states of the source emission appears to be necessary.

  • PDF

Critical Current Estimation of HTS Magnets by using Field Dependent E-J Relation (전계를 이용한 팬케이크 권선으로 제작되는 마그넷의 임계전류 산정)

  • Kang, Myung-Hun;Koo, Myung-Hwan;Lee, Hee-Joon;Cha, Guee-Soo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.3
    • /
    • pp.502-508
    • /
    • 2009
  • The method to determine the operating current of HTS magnets needs to be different from that of LTS magnets. This paper presented estimation of the critical current of pancake windings. The pancake windings can be excited by a single power source or by multiple power sources. Critical currents were determined by using field dependent E-J relation. For the better estimation of the critical current, a new method to define the magnetic field of the HTS wire has been proposed. Calculated critical currents of pancake windings were compared with measured ones of the HTS BSCCO magnet consisting of 10 pancake windings. According to the test results, the estimated critical currents of pancake windings agreed well with that of measured ones. Effects of the single and multiple power source excitation on the critical currents have been also examined.