• Title/Summary/Keyword: Multiple electrodes

검색결과 97건 처리시간 0.029초

Brain Wave Characteristic Analysis by Multi-stimuli with EEG Channel Grouping based on Binary Harmony Search (Binary Harmony Search 기반의 EEG 채널 그룹화를 이용한 다중 자극에 반응하는 뇌파 신호의 특성 연구)

  • Lee, Tae-Ju;Park, Seung-Min;Sim, Kwee-Bo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • 제19권8호
    • /
    • pp.725-730
    • /
    • 2013
  • This paper proposed a novel method for an analysis feature of an Electroencephalogram (EEG) at all channels simultaneously. In a BCI (Brain-Computer Interface) system, EEGs are used to control a machine or computer. The EEG signals were weak to noise and had low spatial resolution because they were acquired by a non-invasive method involving, attaching electrodes along with scalp. This made it difficult to analyze the whole channel of EEG signals. And the previous method could not analyze multiple stimuli, the result being that the BCI system could not react to multiple orders. The method proposed in this paper made it possible analyze multiple-stimuli by grouping the channels. We searched the groups making the largest correlation coefficient summation of every member of the group with a BHS (Binary Harmony Search) algorithm. Then we assumed the EEG signal could be written in linear summation of groups using concentration parameters. In order to verify this assumption, we performed a simulation of three subjects, 60 times per person. From the simulation, we could obtain the groups of EEG signals. We also established the types of stimulus from the concentration coefficient. Consequently, we concluded that the signal could be divided into several groups. Furthermore, we could analyze the EEG in a new way with concentration coefficients from the EEG channel grouping.

Determination of Mercury at Electrodes Modified with Poly-$[Ru(v-bpy)_3]^{2+}$ Incorporating Amino Acids (몇 가지 아미노산으로 변성한 $[Ru(v-bpy)_3]^{2+}$ 고분자 피막 전극을 이용한 수은의 정량)

  • Cha, Seong Keuk
    • Journal of the Korean Chemical Society
    • /
    • 제40권8호
    • /
    • pp.542-548
    • /
    • 1996
  • Electrodes modified with threonine, methionine and serine as ligands, which are incorporated by ion exchange into a polycationic film of electropolymerized $[Ru(v-bpy)_3]^{2+}$, have been employed in the determination of mercury in solution. The redox response of the surface-immobilized mercury/ligand complex was used as the analytical signal. When the polymeric film was electropolymerized, the supporting electrolytes were TBAP and $KPF_6$ to compare the morphology and anodic stripping of resulted polymer electrodes. At the case of the latter, the film had high porosity to give an easy incorporation of dopant anions into polymeric film matrix and a high sensitivity in determination of mercury ion. Especially, this polymer modified electrode exhibited possibility of multiple use in mercury determination over ten times. In all cases, calibration curves which were plotted by log of the surface coverage-normalized redox response vs. log[Hg] exhibited an excellent correlation (r=0.99) for mercury concentrations ranging from 1.0{\times}10^{-8}{\sim}1.0{\times}10^{-2}M$. At these curves relative standard deviation was 5∼8% and saturation response was not observed at high concentration region. Serine of the employed ligands had the best sensitivity in analytical application, which had greater stability constant in forming a complex with mercury than others as $pK_{Hg}=8.54$. The formation constants of threonine and methionine were respectively 7.04 and 7.80.

  • PDF

Sensing NO3-N and K Ions in Hydroponic Solution Using Ion-Selective Membranes (이온선택성 멤브레인을 이용한 양액 내 질산태 질소 및 칼륨 측정)

  • Kim, Won-Kyung;Park, Tu-San;Kim, Young-Joo;Roh, Mi-Young;Cho, Seong-In;Kim, Hak-Jin
    • Journal of Biosystems Engineering
    • /
    • 제35권5호
    • /
    • pp.343-349
    • /
    • 2010
  • Rapid on-site sensing of nitrate-nitrogen and potassium ions in hydroponic solution would increase the efficiency of nutrient use for greenhouse crops cultivated in closed hydroponic systems while reducing the potential for environmental pollution in water and soil. Ion-selective electrodes (ISEs) are a promising approach because of their small size, rapid response, and the ability to directly measure the analyte. The capabilities of the ISEs for sensing nitrate and potassium in hydroponic solution can be affected by the presence of other ions such as calcium, magnesium, sulfate, sodium, and chloride in the solution itself. This study was conducted to investigate the applicability of two ISEs consisting of TDDA-NPOE and valinomycin-DOS PVC membranes for quantitative determinations of $NO_3$-N and K in hydroponic solution. Nine hydroponic solutions were prepared by diluting highly concentrated paprika hydroponic solution to provide a concentration range of 3 to 400 mg/L for $NO_3$-N and K. Two of the calibration curves relating membrane response and nutrient concentration provided coefficients of determination ($R^2$) > 0.98 and standard errors of calibration (SEC) of < 3.79 mV. The use of the direct potentiometry method, in conjunction with an one-point EMF compensation technique, was feasible for measuring $NO_3$-N and K in paprika hydroponic solution due to almost 1:1 relationships and high coefficients of determination ($R^2$ > 0.97) between the levels of $NO_3$-N and K obtained with the ion-selective electrodes and standard instruments. However, even though there were strong linear relationships ($R^2$ > 0.94) between the $NO_3$-N and K concentrations determined by the Gran's plot-based multiple standard addition method and by standard instruments, hydroponic $NO_3$-N concentrations measured with the ISEs, on average, were about 10% higher than those obtained with the automated analyzer whereas the K ISE predicted about 59% lower K than did the ICP spectrometer, probably due to no compensation for a difference between actual and expected concentrations of standard solutions directly prepared.

Improved Photovoltaic Performance of Inverted Polymer Solar Cells using Multi-functional Quantum-dots Monolayer

  • Moon, Byung Joon;Lee, Kyu Seung;Kim, Sang Jin;Shin, Dong Heon;Oh, Yelin;Lee, Sanghyun;Kim, Tae-Wook;Park, Min;Son, Dong Ick;Bae, Sukang
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.400.1-400.1
    • /
    • 2016
  • Interfacial engineering approaches as an efficient strategy for improving the power conversion efficiencies (PCEs) of inverted polymer solar cells (iPSCs) has attracted considerable attention. Recently, polymer surface modifiers, such as poly(ethyleneimine) (PEI) and polyethylenimine ethoxylated (PEIE), were introduced to produce low WF electrodes and were reported to have good electron selectivity for inverted polymer solar cells (iPSCs) without an n-type metal oxide layer. To obtain more efficient solar cells, quantum dots (QDs) are used as effective sensitizers across a broad spectral range from visible to near IR. Additionally, they have the ability to efficiently generate multiple excitons from a single photon via a process called carrier multiplication (CM) or multiple exciton generation (MEG). However, in general, it is very difficult to prepare a bilayer structure with an organic layer and a QD interlayer through a solution process, because most solvents can dissolve and destroy the organic layer and QD interlayer. To present a more effective strategy for surpassing the limitations of traditional methods, we studied and fabricated the highly efficient iPSCs with mono-layered QDs as an effective multi-functional layer, to enhance the quantum yield caused by various effects of QDs monolayer. The mono-layered QDs play the multi-functional role as surface modifier, sub-photosensitizer and electron transport layer. Using this effective approach, we achieve the highest conversion efficiency of ~10.3% resulting from improved interfacial properties and efficient charge transfer, which is verified by various analysis tools.

  • PDF

Analysis of the Effect on the Performance of Ceramic Metal Halide Lamp by the Loss of Elements that have been Filled in Arc Tube (아크튜브내의 구성물 손실이 세라믹 메탈 핼라이드 램프의 특성에 미치는 영향분석)

  • Jang, Hyeok-Jin;Yang, Jong-Kyung;Park, Dae-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • 제58권12호
    • /
    • pp.2446-2452
    • /
    • 2009
  • A Ceramic Metal-halide lamp is achieved by adding multiple metals to a basic mercury discharge. Because the vapor pressure of most metals is very much lower than mercury itself, metal-halide salts of the desired metals, having higher vapor pressures, are used to introduce the material into the basic discharge. The metal compounds are usually polyatomic iodides, which vaporize and subsequently dissociate as they diffuse into the bulk plasma. Metals with multiple visible transitions are necessary to achieve high photometric efficiency and good color. Compounds of Sc, Dy, Ho, Tm, Ce, Pr, Yb and Nd are commonly used. The maximum visible efficacy of a Ceramic Metal Halide lamp, under the constant of a white light source, is predicted to be about 450lm/W. This is controlled principally by the chemical fill chosen for a particular lamp. Current these lamps achieve 130lm/W and these life time are the maximum 16,000[hr]. So factors of performance lower are necessary to improve lamp performance. In this paper, we analyzed factors of performance lower by accelerated deterioration test. The lamp was operated with short duration turn-on/turn-off procedure to enhance the effect due to electrode sputtering during lamp ignition. The tested lamp that was operated with a longer turn-on/off(20/20 minutes) showed blackening, changed distance between electrodes and lowered color rendering & color temperature by losses of Dy at 421.18nm, I at 511nm, T1 at 535nm and Na at 588nm compared with the new lamp.

A Study on the Simulator for the fabrication of bandpass filter for the Wide-band Codeless Division Multiple Access (광 대역 통과 필터 제작을 위한 모의 실험기)

  • 유일현
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • 제8권3호
    • /
    • pp.686-693
    • /
    • 2004
  • We have studied a method to fabricated a Surface Acoustic Waves (SAW) filter for Wide band Codeless Division Multiple Access(WCDMA) was formed on the Langasite substrate and was evaporated by Aluminum-Copper alloy and then we developed a simulator using the mathematica package. And, we can design and fabricate the Slanted finger Inter-digital Transducer (SFIT) for the purpose to decreased the ultimate rejections on side of the electrodes, and performed computer-simulation by simulator. Also, we have employed that the block weighted type Inter-digital Transduce(IDT) as input transduce of the filter and the withdrawal weighted type IDT as an output transducer of the filter in order to minimize effect of diffractions. We have employed that the number of pairs of the input and output IDT are 50 pairs and the thickness and the width of reflector are $5000\AA$, and $1\lambda/4(\cong3.6{\mu}m)$, respectively. Also the width of IDT' finger and the space between IDT' finger and reflector are $1\lambda$/16 and 1\lambda$/8, respectively. Frequency response of the fabricated SAW bandpass filter has the property that center frequency is about 190MHz, bandwidth at the 3dB is probably 4MHz and out-band attenuation is -60dB approximately.

Acquisition and Classification of ECG Parameters with Multiple Deep Neural Networks (다중 심층신경망을 이용한 심전도 파라미터의 획득 및 분류)

  • Ji Woon, Kim;Sung Min, Park;Seong Wook, Choi
    • Journal of Biomedical Engineering Research
    • /
    • 제43권6호
    • /
    • pp.424-433
    • /
    • 2022
  • As the proportion of non-contact telemedicine increases and the number of electrocardiogram (ECG) data measured using portable ECG monitors increases, the demand for automatic algorithms that can precisely analyze vast amounts of ECG is increasing. Since the P, QRS, and T waves of the ECG have different shapes depending on the location of electrodes or individual characteristics and often have similar frequency components or amplitudes, it is difficult to distinguish P, QRS and T waves and measure each parameter. In order to measure the widths, intervals and areas of P, QRS, and T waves, a new algorithm that recognizes the start and end points of each wave and automatically measures the time differences and amplitudes between each point is required. In this study, the start and end points of the P, QRS, and T waves were measured using six Deep Neural Networks (DNN) that recognize the start and end points of each wave. Then, by synthesizing the results of all DNNs, 12 parameters for ECG characteristics for each heartbeat were obtained. In the ECG waveform of 10 subjects provided by Physionet, 12 parameters were measured for each of 660 heartbeats, and the 12 parameters measured for each heartbeat well represented the characteristics of the ECG, so it was possible to distinguish them from other subjects' parameters. When the ECG data of 10 subjects were combined into one file and analyzed with the suggested algorithm, 10 types of ECG waveform were observed, and two types of ECG waveform were simultaneously observed in 5 subjects, however, it was not observed that one person had more than two types.

Nano-scale pattern delineation by fabrication of electron-optical lens for micro E-beam system (마이크로 전자빔 시스템을 위한 전자광학렌즈의 제작에 의한 나노 패턴 형성)

  • Lee, Yong-Jae;Park, Jung-Yeong;Chun, Kuk-Jin;Kuk, Young
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • 제35D권9호
    • /
    • pp.42-47
    • /
    • 1998
  • We have fabricated electron-optical lens for micro E-beam system that can overcome the limitation of current E-beam lithography. Our electron-optical lens consists of multiple silicon electrodes which were fabricated by micromachining technology and assembled by anodic bonding. The assembled system was installed in UHV chamber to observe the emission characteristics of focused electrons by the electro-optical lens. We used STM(Scanning Tunneling Microscope) tip for electron source. By performing lithography with the focused electrons with PMMA(poly-methylmethacrylate) as E-beam resist. We could draw 0.13${\mu}{\textrm}{m}$ nano-scale lines.

  • PDF

Optimization of Measuring Cardiac Output by Both Hands Electrode Impedance Method (양손 전극의 임피던스법을 이용한 심박출량 측정의 최적화)

  • Jung, Sang-O;Sim, Myeong-Heon;Jung, Woon-Mo;Kim, Min-Yong;Yoon, Chan-Sol;Yoon, Hyung-Ro
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • 제60권9호
    • /
    • pp.1770-1776
    • /
    • 2011
  • In this study, a new method that can estimate ICG data from a subject's both hands to measure Cardiac Output under convenient sensor environment. With this aim, a grip-type electrode was implemented to measure ICG. To improve the accuracy of measurement, the regression equation was extracted using multiple bio-parameters and our result was compared with the thoracic ICG equipment(Physio Flow$^{(R)}$, PF104D, Manatec Biomedical, France), which is being used in clinics. The subjects consist of 26 men and 4 women(age in $22.0{\pm}3.32$). They are no cardiac disease. Parameters available for regression model were used gender, BMI, MBP, LVET, dZ/dt(max), distance between the measured electrodes, body impedance, and PTT. As a result of analyzing the ICG measurement value on thorax and both hands, the correlation with stroke volume, heart rate, and cardiac output was $R^2$=0.853, $R^2$=0.958 and $R^2$=0.899, respectively.

Study on High Efficiency EEFL Backlight inverter for 32-inch LCD TV

  • Oh, Won-Sik;Cho, Kyu-Min;Moon, Gun-Woon;Min, Sook-Kyu;Kim, Hyun-Jin;Jeon, Hyoung-Jun;Kim, Jong-Sun;Mim, Byoung-Woon
    • Proceedings of the KIPE Conference
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.405-407
    • /
    • 2005
  • As the screen size of LCD increases, EEFL(External Electrode Fluorescent Lamp) has been suggested to be applicable as backlight source for LCD . Since the electrodes of EEFL are outside of the tube, EEFL enhances the lifetime compared with CCFL(Cold Cathode Fluorescent Lamp), and a single inverter can drive multiple EEFL tubes of which luminance is uniform Therefore, a compact design can be realized and the cost of EEFL application would be much lower than that of CCFL. Moreover, EEFL inverter has higher efficiency per unit power than CCFL inverter. In this paper, a complementary full-bridge PWM(Pulse Width Modulation) inverter was designed for 32-inch LCD TV backlight which has 20 EEFL tubes and adapted two different driving methods to the EEFL inverter. The validity of this study is confirmed from the experimental results.

  • PDF