• Title/Summary/Keyword: Multiple electrodes

Search Result 97, Processing Time 0.029 seconds

Development of Exercise Analysis System Using Bioelectric Abdominal Signal (복부생체전기신호를 이용한 운동 분석 시스템 개발)

  • Gang, Gyeong Woo;Min, Chul Hong;Kim, Tae Seon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.11
    • /
    • pp.183-190
    • /
    • 2012
  • Conventional physical activity monitoring systems, which use accelerometers, global positioning system (GPS), heartbeats, or body temperature information, showed limited performances due to their own restrictions on measurement environment and measurable activity types. To overcome these limitations, we developed a portable exercise analysis system that can analyze aerobic exercises as well as isotonic exercises. For bioelectric signal acquisition during exercise, waist belt with two body contact electrodes was used. For exercise analysis, the measured signals were firstly divided into two signal groups with different frequency ranges which can represent respiration related signal and muscular motion related signal, respectively. After then, power values, differential of power values, and median frequency values were selected for feature values. Selected features were used as inputs of support vector machine (SVM) to classify the exercise types. For verification of statistical significance, ANOVA and multiple comparison test were performed. The experimental results showed 100% accuracy for classification of aerobic exercise and isotonic resistance exercise. Also, classification of aerobic exercise, isotonic resistance exercise, and hybrid types of exercise revealed 92.7% of accuracy.

Real-Time Monitoring of Mitochondrial ATP Synthesis and Hydrolysis by Surface Infrared Spectroscopy

  • Yamaguchi, Ryo-Taro;Hirano-Iwata, Ayumi;Aonuma, Yuki;Yoshimura, Yuya;Shinohara, Yasuo;Kimura, Yasuo;Niwano, Michio
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.108-109
    • /
    • 2013
  • Mitochondria play key roles in the production of cell's energy. Their dominant function is the synthesis of adenosine 5'-triphosphate (ATP) from adenosine diphosphate (ADP) and phosphate (Pi) through the oxidative phosphorylation. Evaluation of drug-induced mitochondrial toxicity has become increasingly important since mitochondrial dysfunction has recently been implicated in numerous diseases including cancer and diabetes mellitus. Mitochondrial functions have been monitored via oxygen consumption, mitochondrial membrane potential, and more importantly via ATP synthesis since ATP synthesis is the most essential function of mitochondria. Various analytical methods have been employed to investigate ATP synthesis in mitochondria, including high performance liquid chromatography (HPLC), bioluminescence technique, and pH measurement. However, most of these methods are based on destructive analysis or indirect monitoring through the enzymatic reaction. Infrared absorption spectroscopy (IRAS) is one of the useful techniques for real-time, label-free, and direct monitoring of biological reactions [1,2]. However, the strong water absorption requires very short path length in the order of several micrometers. Transmission measurements with thin path length are not suitable for mitochondrial assays because solution handlings necessary for evaluating mitochondrial toxicity, such as rapid mixing of drugs and oxygen supply, are difficult in such a narrow space. On the other hand, IRAS in the multiple internal reflection (MIR) geometry provides an ideal optical configuration to combine solution handling and aqueous-phase measurement. We have recently reportedon a real-time monitoring of drug-induced necrotic and apoptotic cell death using MIR-IRAS [3,4]. Clear discrimination between viable and damaged cells has been demonstrated, showing a promise as a label-free and real-time detection for cell-based assays. In the present study, we have applied our MIR-IRAS system to mitochondria-based assays by monitoring ATP synthesis in isolated mitochondria from rat livers. Mitochondrial ATP synthesis and hydrolysis were in situ monitored with MIR-IRAS, while dissolved oxygen level and solution pH were simultaneously monitored with O2 and pH electrodes, respectively. It is demonstrated that ATP synthesis and hydrolysis can be monitored by the IR spectral changes in phosphate groups in adenine nucleotides and MIR-IRAS is useful for evaluating time-dependent drug effects of mitochondrial toxicants.

  • PDF

Effects of Gradient Switching Noise on ECD Source Localization with the EEG Data Simultaneously Recorded with MRI (MRI와 동시에 측정한 뇌전도 신호로 전류원 국지화를 할 때 경사자계 유발 잡음의 영향 분석)

  • Lee H. R.;Han J. Y.;Cho M. H.;Im C. H.;Jung H. K.;Lee S. Y.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.7 no.2
    • /
    • pp.108-115
    • /
    • 2003
  • Purpose : To evaluate the effect of the gradient switching noise on the ECD source localization with the EEG data recorded during the MRI scan. Materials and Methods : We have fabricated a spherical EEG phantom that emulates a human head on which multiple electrodes are attached. Inside the phantom, electric current dipole(ECD) sources are located to evaluate the source localization error. The EEG phantom was placed in the center of the whole-body 3.0 Tesla MRI magnet, and a sinusoidal current was fed to the ECD sources. With an MRI-compatible EEG measurement system, we recorded the multi channel electric potential signals during gradient echo single-shot EPI scans. To evaluate the effect of the gradient switching noise on the ECD source localization, we controlled the gradient noise level by changing the FOV of the EPI scan. With the measured potential signals, we have performed the ECD source localization. Results : The source localization error depends on the gradient switching noise level and the ECD source position. The gradient switching noise has much bigger negative effects on the source localization than the Gaussian noise. We have found that the ECD source localization works reasonably when the gradient switching noise power is smaller than $10\%$ of the EEG signal power. Conclusion : We think that the results of the present study can be used as a guideline to determine the degree of gradient switching noise suppression in EEG when the EEG data are to be used to enhance the performance of fMRI.

  • PDF

Assessment of Regulatory Effect of Electro-acupuncture at Jogsamni($ST_{36}$), on Electrogastrography in Diabetic Patients with Gastric Dysrhythmia;A Case Series Study (위장 비율동성 당뇨환자에서 족삼리(足三里)($ST_{36}$) 전침처치의 위전도 조절 영향 사례군 연구)

  • Oh, Dal-Seok;Choi, Jun-Yong;Jung, So-Young;Shin, Mi-Suk;Kim, Ae-Ran;Kang, Kyung-Won;Kim, Jong-In;Choi, Sun-Mi
    • Journal of Acupuncture Research
    • /
    • v.25 no.4
    • /
    • pp.95-103
    • /
    • 2008
  • Objectives : This study was to investigate the regulatory effect of electro-acupuncture on Jogsamni ($ST_{36}$) in bradygastric condition or gastroparesis which is a neuropathic complication of type 2 diabetes mellitus(T2DM), assessed using 4-channel electrogastrography (EGG). Methods : It was a case series study. Each patient was given electro-acupuncture(EA) one point, Jogsamni($ST_{36}$) or Gyeonu($LI_{15}$) bilaterally for thirty minutes with 2Hz bipolar square wave frequency and moderate intensity of stimulation. With attaching electrodes around stomach region throughout pre-acupuncture, acupuncture, and post-acupuncture session, these parameters were produced; percent rate of bradygastria power compared to sum of power in all kind of gastric rhythm(% bradygastria), dominant frequency(DF) and dominant power(DP). Parameter was analysed per each channel's variable change from pre-acupuncture session by paired t-test. Results : There was statistically significant decrease in % bradygastria parameters on one of the $ST_{36}$ treated patients from pre-acupuncture session and to post-acupuncture session(P=0.015, P=0.008 respectively). A marginal significant decrease of DP was shown in the other $ST_{36}$ treated patient from pre-acupuncture session through post-acupuncture session(P=0.049). Combined data of two $ST_{36}$ Treated patients showed that there was significant decrease of %bradygastria from pre-acupuncture session to acupuncture session(P=0.020), and was decrease of DP from pre-acupuncture session to post- acupuncture session(P=0.020). Conclusions : EA at $ST_{36}$ resulted in statistically significant decrease in %bradygastria and DP for dysrhythmic condition in T2DM gastroparesis patients. Considering this limited results, further study will be needed to elucidate the effect of multiple-acupuncture on gastric myoelectrical activities.

  • PDF

Study on the Scan Field of Modified Octupole and Quadrupole Deflector in a Microcolumn (마이크로칼럼에서 변형된 4중극 디플렉터와 8중극 디플렉터의 스캔 영역 비교)

  • Kim, Young Chul;Kim, Ho-Seob;Ahn, Seong Joon;Oh, Tae-Sik;Kim, Dae-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.11
    • /
    • pp.1-7
    • /
    • 2018
  • In a microcolumn, a miniaturized electrostatic deflector is often adopted to scan an electron beam. Usually, a double octupole deflector is used because it can avoid excessive spherical aberrations by controlling the electron beam path close to the optical axis of the objective lens and has a wide scan field. Studies on microcolumns have been performed to improve the low throughput of an electron column through multiple column applications. On the other hand, as the number of microcolumns increases, the number of wires connected to the components of the microcolumn increases. This will result in practical problems during the process of connecting the wires to electronic controllers outside of the vacuum chamber. To reduce this problem, modified quadrupole and octupole deflectors were examined through simulation analysis by selecting an ultraminiaturized microcolumn with the Einzel lens eliminated. The modified deflectors were designed changing the size of each electrode of the conventional Si octupole deflector. The variations of the scan field and electric field strength were studied by changing the size of active electrodes to which the deflection voltage was to be applied. The scan field increased linearly with increasing deflection voltage. The scan field of the quadrupole deflector and the electric field strength at the center were calculated to be approximately 1.3 ~ 2.0 times larger than those of the octupole deflector depending on the electrode size.

Enhancement of Electrochemical Performance of Cathode by Optimizing Laccase-Carbon Nanotubes Layers for Enzymatic Fuel Cells (Laccase-탄소나노튜브 적층을 통한 효소 연료전지의 cathode 성능 향상)

  • Wang, Xue;Kim, Chang-Joon
    • Korean Chemical Engineering Research
    • /
    • v.60 no.4
    • /
    • pp.550-556
    • /
    • 2022
  • The performance of enzymatic fuel cells that convert chemical energy contained in various organic molecules such as sugar, alcohol, organic acids, and amino acids into electrical energy is greatly affected by the cathode as well as the anode. This study aimed to develop a laccase-based cathode with high performance. An enzyme composite composed of an laccase, redox mediator, and carbon nanotubes was immobilized on the surface of electrode in multiple layers, and the effect of the number of layers and the presence or absence of carbon nanotubes on electrode performance was investigated. As the number of layers of the enzyme-mediator (Lac-(PVI-Os-dCl)) on the electrode surface increased, the amount of reduction current generated at the electrode increased. The enzyme-carbon nanotube-mediator composite electrode (Lac-SWCNTs-(PVI-Os-dCl)) generated a current 1.7 times greater than that of the Lac-(PVI-Os-dCl). It was found that the largest amount of current (10.1±0.1 µA) was generated in the electrode composed of two layers of Lac-(PVI-Os-dCl) and two layers of Lac-SWCNTs-(PVI-Os-dCl) in the evaluation of electrodes with different ratio of Lac-SWCNTs-(PVI-Os-dCl) and Lac-(PVI-Os-dCl). The maximum power density of the cell using the cathode composed of a single layer of Lac-(PVI-Os-dCl) and the cell using the optimized cathode were 0.46±0.05 and 1.23±0.04 µW/cm2, respectively. In this study, it was demonstrated that the performance of cathode and the enzymatic fuel cell using the same can be improved by optimizing the layers of composites composed of laccase, redox mediator, and carbon nanotubes on the electrode surface.

Evaluation of Dynamic X-ray Imaging Sensor and Detector Composing of Multiple In-Ga-Zn-O Thin Film Transistors in a Pixel (픽셀내 다수의 산화물 박막트랜지스터로 구성된 동영상 엑스레이 영상센서와 디텍터에 대한 평가)

  • Seung Ik Jun;Bong Goo Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.359-365
    • /
    • 2023
  • In order to satisfy the requirements of dynamic X-ray imaging with high frame rate and low image lag, minimizing parasitic capacitance in photodiode and overlapped electrodes in pixels is critically required. This study presents duoPIXTM dynamic X-ray imaging sensor composing of readout thin film transistor, reset thin film transistor and photodiode in a pixel. Furthermore, dynamic X-ray detector using duoPIXTM imaging sensor was manufactured and evaluated its X-ray imaging performances such as frame rate, sensitivity, noise, MTF and image lag. duoPIXTM dynamic X-ray detector has 150 × 150 mm2 imaging area, 73 um pixel pitch, 2048 × 2048 matrix resolution(4.2M pixels) and maximum 50 frames per second. By means of comparison with conventional dynamic X-ray detector, duoPIXTM dynamic X-ray detector showed overall better performances than conventional dynamic X-ray detector as shown in the previous study.