• Title/Summary/Keyword: Multiple dose

Search Result 493, Processing Time 0.026 seconds

Characteristics of Tissue Dose of High Dose Rate Ir-192 Source Substitution for Co-60 Brachytherapy Source (코발트-60 선원 대체용 고선량률 Ir-192 선원의 조직선량특성)

  • 최태진;이호준;김옥배
    • Progress in Medical Physics
    • /
    • v.9 no.4
    • /
    • pp.259-266
    • /
    • 1998
  • To achieve the 2D dose distribution around the designed high dose rate Ir-192 source substitution for Co-60 brachytherapy source, we determined the exposure rate constant and tissue attenuation factors as a large depth as a 20 cm from source center. The exposure rate constant is used for apparent activity in designed source with self-absorption and encapsulation steel wall. The tissue dose delivered from the 4401 segments of 2.5 mm in a diameter and 2.5 mm height of disk-type source layer. In the experiments, the tissue attenuation factors include the tissue attenuation and multiple scattering in a medium surrounding the source. The fitted the polynomial regression with 4th order for the tissue attenuation factors are very closed to the experimental measurement data within ${\pm}$1% discrepancy. The Meisberger's constant showed the large uncertainty in large distance from source. The exposure rate constant 4.69 Rcm$^2$/mCi-hr was currently used for determination of apparent activity of source and air kerma strength was obtained 0.973 for tissue absorbed dose from the energy spectrum of Ir-192 source. In our experiments with designed high dose rate brachytherapy source, the apparent activity of Ir-192 source was delivered from the 54.6 % of actual physical source activity through the self-absorption and encapsulation wall attenuations. This paper provides the 2-dimensional dose tabulation from unit apparent activity in a water medium for dose planning includes the multiple scattering, source anisotropy effect and geometric factors.

  • PDF

Absorbed Dose Analysis in Water for Proton Beam using PTRAN Code System (PTRAN 코드를 이용한 양성자선에 대한 물 흡수선량의 해석)

  • Kim Jin Young;Jeong Dong Hyeok
    • Progress in Medical Physics
    • /
    • v.15 no.3
    • /
    • pp.140-148
    • /
    • 2004
  • The absorbed dose for proton beam in water was calculated using the PTRAN code system. The proton interactions with water and the description on absorbed dose calculations are discussed, and the file structure and an execution example of the PTRAN codes are described. For 60, 100, 150, 200, and 250 MeV proton beams it is demonstrated that the absorbed dose is determined from the sum of Coulomb interactions and nuclear reactions, and that the Bragg peak feature depends On the energy straggling and multiple scattering. The PTRAN code was useful for studying the fundamental mechanism of the absorbed dose to water for clinical proton beams.

  • PDF

Induction of SOS Genes by a Low Dose of Gamma Radiation, 10 Gy, in Salmonella enterica Serovar Typhimurium

  • Lim, Sangyong;Joe, Minho;Seo, Hoseong;Kim, Dongho
    • Journal of Radiation Industry
    • /
    • v.7 no.2_3
    • /
    • pp.109-113
    • /
    • 2013
  • In a previous study, a relatively high dose of gamma radiation (1 kGy) did not fully induce typical SOS genes such as sulA, recA, recN, and din in Salmonella Typhimurium (S. Typhimurium) (Lim et al. 2008, Gene expression profiles following high-dose exposure to gamma radiation in Salmonella enterica serovar Typhimuium. J. Radiat. Ind. 3:111-119). In this study, we examined changes in the transcriptional repertoire of S. Typhimurium after a dose of 10 Gy using DNA microarrays. It was found that more than half (~65%) of the 26 up-regulated genes belong to the SOS regulon: ten genes are typical SOS genes, and seven genes are Salmonella prophage genes, which are known to be activated by LexA cleavage. Among 29 down-regulated genes, the function of five genes with the most decreased expression is associated with carbohydrate transport and energy production. This suggests that upon exposure to gamma radiation cells may cease growing by reducing the metabolic activity, and repair DNA damage using a DNA repair system such as the SOS response system. The difference in expression of the SOS genes between a high (1 kGy) and low (10 Gy) dose of radiation shows the possibility that cells may opt for one of multiple regulatory circuits in response to the specific gamma radiation dose.

Efficacy of Multiple Low-dose Photodynamic TMPYP4 Therapy on Cervical Cancer Tumour Growth in Nude Mice

  • Liu, Ai-Hong;Sun, Xuan;Wei, Xiao-Qiang;Zhang, You-Zhong
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.9
    • /
    • pp.5371-5374
    • /
    • 2013
  • Objective: Photodynamic therapy (PDT) is an emerging therapeutic procedure suitable for the treatment of cervical cancer. However, the side effects of PDT are severe, including skin ulceration, so we designed an experiment to examine the effects of multiple low-dose photodynamic therapy of 5, 10, 15, 20-tetrakis(1-methylpyridinium-4-yl) porphyrin (Tmpyp4) on tumour growth by utilizing a model in nude mice implanted with Hela cervical cancer cells. Materials and Methods: Female BALB/c nude mice (aged 5-6 weeks, weighing 18-20 g) were used. Hela cervical cancer cells were injected subcutaneously ($1{\times}10^7cells/200{\mu}L$). Ten days after injection, the mice were divided into three groups (n=6), the A group of controls without any treatment, the B group receiving a single-treatment with Tmpyp4 (10 mg/kg, intratumor injection) and irradiation (blue laser, $108J/cm^2$), and the C group given three-treatments with Tmpyp4 (10 mg/kg, intratumor injection) and irradiation at intervals of two days. After starting treatment, tumours were measured every two days, to assess growth. At 2 weeks after the last treatment of C group, tumour tissue and organs were collected from each mouse to evaluate tumor histology and organ damage. Results: Tumour growth in C group was significantly inhibited compared with A and B groups (P<0.05), without any injury to the skin and internal organs. Conclusion: Our novel findings demonstrated that multiple low-dose photodynamic therapy of Tmpyp4 could inhibit cervical cancer growth significantly with no apparent side effects.

Comparison of Clinical Progress between Single- and Multiple-dose Surfactant Treatment in Neonatal Respiratory Distress Syndrome (신생아 호흡곤란증후군에서 폐 표면활성제 단일 투여군과 재투여군의 임상경과 비교)

  • Kil, Chang Hee;Jeon, Ho Sang;Bae, Chong Woo
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.10
    • /
    • pp.1090-1095
    • /
    • 2005
  • Purpose : In the case of serious respiratory distress syndrome(RDS) or relapse of clinical appearances after single treatment, we obtained more effective results with multiple-dose surfactant replacement therapy. We carried out this investigation for comparing and observing clinical progress between single-dose(group S) and multiple-dose(group M) pulmonary surfactant treatment group of neonatal RDS. Methods : We investigated 48 neonates who were diagnosed as RDS and treated with pulmonary surfactant(PS) replacement therapy in NICU of Kyunghee University hospital from January 2002 to March 2004, then we compared and verified clinical progress of 32 neonates in group S with that of 16 neonates in group M. Results : There were no significant statistical differences in average birth weights, average gestational periods, initial pH values of birth, whether operation of resuscitation at that time of birth was made or not, whether prenatal steroid prescription for mother, RDS classification standardized by Bomsel, and ventilation index(VI) before instillation of PS of two groups. However, there was significant statistical difference in a/A $PO_2$(P<0.05). We could observe changes of VI and a/A $PO_2$ within 72 hours have been continuously improved at group S rather than group M. In spite of relapses, group M changed for the better after second dose. There were also no significant differences between the two groups in duration of ventilator therapy, mortality within 28 days after birth, intraventricular hemorrhage by complication, retinopathy of premature, necrotizing enterocolitis, chronic lung diseases, sepsis, and DIC. Conclusion : In these relapse cases, as there were no significant differences in the mortality rate and the occurence of complication between group S and group M, the requirement of multiple-dose PS replacement therapy which brought improvement of prognosis was emphasized.

The Effects of Regular Injection of High Dose Vitamin C on Liver Damage in Paraquat Poisoned Rat Model - Prehospital Care Model - (백서의 paraquat 중독모델에서 고용량 Vitamin C의 주기적 투여가 간에 미치는 영향 병원전 처치 모델)

  • Cho, Keun-Ja
    • The Korean Journal of Emergency Medical Services
    • /
    • v.10 no.1
    • /
    • pp.51-60
    • /
    • 2006
  • Background: The toxicity of paraquat has been known to be caused by oxygen free radicals which leads to the lipid peroxidation and multiple organ failure. High dose vitamin C has been known to be a effective antioxidant activities against the paraquat intoxication. This study was designed to evaluate the effect of regular injection of high dose vitamin C on liver damage in paraquat poisoned rat model. Method: Fifty five rats of Sprague-Dawley strain were divided into three groups: control group, only intraperitoneally injected saline; paraquat group, single dose intraperitoneally injected paraquat(24.5%, 40 mg/kg) and every 8 hours injected saline; paraquat and vitamin C group, single dose intraperitoneally injected paraquat(24.5%, 40 mg/kg) and every 8 hours injected vitamin C(72 mg/kg). Rats were sacrificed on the 12 hours, 1st day, 2nd day, 4th day, 7th day after injection and liver tissue was obtained. H&E(Hematoxylin & Eosin) stain and Masson's trichrome stain for collagen fiber detection were undertaken. The results were observed using the microscope. Results: 1. There were no differences between control and experimental group at the 12hours after regular injection of high dose vitamin C. 2. There were significantly decreased liver damage in experimental group in the 1st day after regular injection of high dose vitamin C. 3. There were significantly increased recovery of liver damage with time in experimental group after regular injection of high dose vitamin C. Conclusion: These results suggest that regular injection of high dose vitamin C is effective in decreasing liver damage in paraquat intoxication.

  • PDF

Dose Attenuation in the Mid-Cranial Fossa with 6 MV Photon Beam Irradiations (6 MV X-선 조사시 중두개와에서의 선량감쇠)

  • Park, Jeong-Ho;Choi, Tae-Jin;Kim, Ok-Bae
    • Radiation Oncology Journal
    • /
    • v.8 no.1
    • /
    • pp.125-131
    • /
    • 1990
  • In X-ray irradiation, dose distribution depends on multiple parameters, one of them being tissue inhomogeneity to change the dose significantly. considerable dose attenuation through the mid-cranial fossa is expected because of various bony structures in it. Dose distribution around the mid-cranial fossa, following irradiation with 6 MV photon beam, was measured with LiF TLD micro-rod, and compared with the expected dose inthe same sites. In our calculation with $C_f$(correction factor), the expected dose attenuation revealed about $3.74\%$ per 1 cm thickness of bone tissue. And the differences between the expected dose with correction for bone tissue and the measured dose by TLD was small, agreeing within an average variation of $\pm0.21\%$.

  • PDF

PIXEL-BASED CORRECTION METHOD FOR GAFCHROMIC®EBT FILM DOSIMETRY

  • Jeong, Hae-Sun;Han, Young-Yih;Kum, O-Yeon;Kim, Chan-Hyeong;Ju, Sang-Gyu;Shin, Jung-Suk;Kim, Jin-Sung;Park, Joo-Hwan
    • Nuclear Engineering and Technology
    • /
    • v.42 no.6
    • /
    • pp.670-679
    • /
    • 2010
  • In this paper, a new approach using a pixel-based correction method was developed to fix the non-uniform responses of flat-bed type scanners used for radiochromic film dosimetry. In order to validate the method's performance, two cases were tested: the first consisted of simple dose distributions delivered by a single port; the second was a complicated dose distribution composed of multiple beams. In the case of the simple individual dose condition, ten different doses, from 8.3 cGy to 307.1 cGy, were measured, horizontal profiles were analyzed using the pixel-based correcton method and compared with results measured by an ionization chamber and results corrected using the existing correction method. A complicated inverse pyramid dose distribution was made by piling up four different field shapes, which were measured with GAFCHROMIC$^{(R)}$EBT film and compared with the Monte Carlo calculation; as well as the dose distribution corrected using a conventional method. The results showed that a pixel-based correction method reduced dose difference from the reference measurement down to 1% in the flat dose distribution region or 2 mm in a steep dose gradient region compared to the reference data, which were ionization chamber measurement data for simple cases and the MC computed data for the complicated case, with an exception for very low doses of less than about 10 cGy in the simple case. Therefore, the pixel-based scanner correction method is expected to enhance the accuracy of GAFCHROMIC$^{(R)}$EBT film dosimetry, which is a widely used tool for two-dimensional dosimetry.

Ambient dose equivalent measurement with a CsI(Tl) based electronic personal dosimeter

  • Park, Kyeongjin;Kim, Jinhwan;Lim, Kyung Taek;Kim, Junhyeok;Chang, Hojong;Kim, Hyunduk;Sharma, Manish;Cho, Gyuseong
    • Nuclear Engineering and Technology
    • /
    • v.51 no.8
    • /
    • pp.1991-1997
    • /
    • 2019
  • In this manuscript, we present a method for the direct calculation of an ambient dose equivalent (H* (10)) for the external gamma-ray exposure with an energy range of 40 keV to 2 MeV in an electronic personal dosimeter (EPD). The designed EPD consists of a 3 × 3 ㎟ PIN diode coupled to a 3 × 3 × 3 ㎣ CsI (Tl) scintillator block. The spectrum-to-dose conversion function (G(E)) for estimating H* (10) was calculated by applying the gradient-descent method based on the Monte-Carlo simulation. The optimal parameters for the G(E) were found and this conversion of the H* (10) from the gamma spectra was verified by using 241Am, 137Cs, 22Na, 54Mn, and 60Co radioisotopes. Furthermore, gamma spectra and H* (10) were obtained for an arbitrarily mixed multiple isotope case through Monte-Carlo simulation in order to expand the verification to more general cases. The H* (10) based on the G(E) function for the gamma spectra was then compared with H* (10) calculated by simulation. The relative difference of H* (10) from various single-source spectra was in the range of ±2.89%, and the relative difference of H* (10) for a multiple isotope case was in the range of ±5.56%.

Inhibitory Effect of Glycyrrhizin on the Lethality Induced by Lippolysaccharide and Galactosamine (리포폴리사카라이드와 갈락토사민의 투여로 인한 생쥐 치사율에 미치는 글리시리진의 억제효과)

  • Oh, Chang-Wook;Song, Kyung;Park, Eun-Jeon;Sohn, Dong-Hwan;Kim, Jae-Baek;Ko, Geon-Il
    • YAKHAK HOEJI
    • /
    • v.40 no.1
    • /
    • pp.84-89
    • /
    • 1996
  • This study was done to investigate the effect of glycyrrhizin on the lethality induced by galactosamine and lipopolysaccharide coadministration in mice. Glycyrrhizin was injecte d intravenously as a multiple dose at 20, 15, 10, 5, and O hr before galactosamine and lipopolysaccharide coadministration. Lethality and tumor necrosis factor (TNF${\alpha}$) level in serum were surveyed as markers of glycyrrhizin effect. Glycyrrhizin had no effect on the lethality induced by galactosamine and lipopolysaccharide when glycyrrhizin was administered as a single dose. Glycyrrhizin reduced the lethality induced by galactosamine and LPS in dose-dependent manner when glycyrrhizin was administered as a multiple dose at 20, 15, 10, 5 and O hr before galactosamine and lipopolysaccharide coadministration. Glycyrrhizin reduced the serum TNF${\alpha$ level.

  • PDF