• Title/Summary/Keyword: Multiple Pulses

Search Result 78, Processing Time 0.027 seconds

Successive Interactions of a Shock Wave with Serially Arranged Vortices

  • Chang, Se-Myong;Chang, Keun-Shik
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.664-670
    • /
    • 2004
  • Navier-Stokes computation based on a new simplified model is proposed to investigate the interactions of a moving shock wave with multiple vortices arranged in the serial manner. This model problem simulates shock-vortexlet interactions at the shear layer of a compressible vortex often observed in the experiment. Applying the Foppl's idea, we extended the Rankin's model generally used for the description of a single vortex to the multi-vortex version. The acoustic pulses accelerated and decelerated are successively generated and propagated from each shock-vortex interaction, which simply explains the genesis of eccentrically diverging acoustic waves appearing in the experimental photograph.

Performance Analysis of M-ary THMA-UWB System Using MHP as Basis Pulses (MHP를 기저펄스로 사용하는 M진 THMA-UWB 시스템의 성능 분석)

  • Hwang, Jun-Hyeok;Kim, Suk-Chan;Kim, Jin-Sic;Park, Ju-Sung;Choi, Won-Tae;Kang, Bong-Soon
    • Proceedings of the IEEK Conference
    • /
    • 2007.07a
    • /
    • pp.93-94
    • /
    • 2007
  • 이 논문은 시간도약 다중접속(time hopping multiple access: THMA) 초광대역(ultra wideband: UWB) 시스템에서 Modified Hermite Polynomial(MHP)을 기저펄스로 사용하는 M진 고속전송 기법을 제안하고, 시스템의 성능을 분석한다. MHP 펄스 차수들의 상호간 직교성을 이용하여 서로 다른 차수의 MHP 기저펄스 N개를 선형결합하여 M진으로 전송한다. MHP 기저펄스의 상호상관 함수를 구하여 제안하는 M진 시스템의 이론적인 성능을 분석하고, 모의실험을 통해서 기존의 M진 전송에 비해서 시스템의 비트오류확률(bit error rate: BER)이 개선됨을 보인다.

  • PDF

A Study on TDMG Pulse Performance and Structure for Performance Improvement of UWB system (UWB 시스템의 성능개선을 위한 TDMG 펄스 발생기의 성능과 구조에 관한 연구)

  • Ko, Young-Eun;Bang, Sung-Il
    • The KIPS Transactions:PartC
    • /
    • v.11C no.3
    • /
    • pp.395-400
    • /
    • 2004
  • Being aware of growing needs for wireless communication led to the development of UWB systems, this study proposed an impulse for single band UWB systems which does not count a carrier; analyzed the characteristics and the problems of pulses suggested by the existing poise of the Un system; finally, proposed TDMG(Time Delay Multiple Gaussian) pulse that generates signals of UWB without attenuation of pulse width. The hardware structure of the TDMC pulse for the single band UWB system was modelled after describing the pulse in a mathematical method in an attempt to compare with performances of the existing pulses through computer simulation. The outcome of the test unveiled the fact that each center frequency of the TDMG pulse rose approximately 1GHz, and also each l0dB fractional bandwidth of the TDMG pulse was widened over 1GHz. In the case of derivative, center frequencies of the TDMG pulse rose over 1GHz each. As a consequence, the TDMG pulse appeared to have better quality frequency, satisfying the characteristics of spectrum and the band of frequency recommended by the FCC and decreasing interference with other wireless communication systems.

Statistics on Radiation Field Waveforms Associated with Multiple Intracloud Lightning Discharges

  • Lee, Bok-Hee;Lee, Dong-Moon;Ahn, Chang-Hwan;Kim, Young-Bong
    • Journal of KIEE
    • /
    • v.11 no.1
    • /
    • pp.32-40
    • /
    • 2001
  • This paper presents the detailed statistics on radiation field signatures associated with multiple-intracloud lightning discharges. A transient signal recording system was used to measure the electric and magnetic fields produced by lightning flashes. The measurements were made in th summers of 1995 through 1999, and the location of the observation station was in Inchon on the coast of the Yellow Sea in Korea(37$^{\circ}$25'N, 126$^{\circ}$ 39'E). Most of lightning flashes typically contains between two and five strokes. The individual intracloud stork radiation fields were the bipolar pulse. On the average, the ratio of the peak of the second stroke to the first stroke peak was 75.1$\pm$40.1% for the negative, and a fraction of the subsequent stroke peaks were higher than the first stroke peak. The greater the number of the subsequent stroke order, less time separations between strokes were produced. The mean of the depth of the dip was 81.2$\pm$27.9% for the positive polarity and 75.9$\pm$24.4% for the negative. The depth of the dip increased for the positive bipolar pulses and decreased for the negative as the number of the stroke order increased.

  • PDF

Characteristics of the Electric Fields Produced by Multiple Lightning Return Strokes (다중 낙뢰에 의해서 발생한 전장 파형의 특성)

  • 이복희;정동철;이동문
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.6
    • /
    • pp.330-336
    • /
    • 2004
  • In this work, in order to obtain the detailed information about lightning electromagnetic pulses, the electric fields radiated from multiple lightning return strokes were measured and analyzed statistically. The electric field measuring system consists of a hemisphere antenna of 30cm in diameter, integrator and data acquisition device, and its frequency bandwidth ranges from 200Hz to 1.56MHz, and the sensitivity is 0.96㎷/V/m. The electric field signals are digitized every 200ns with the transient signal analyzer having the resolution of 12-bit and the recording length of 5 kilowords and are registered at personal computer. As a result, the electric fields produced by the first return stroke begin with a slow initial part or front, which starts just after or during the last stepped leader. On the average the rise times of the electric fields for the positive first, second and third strokes are 4.21${\mu}\textrm{s}$, 3.94${\mu}\textrm{s}$ and 2.75${\mu}\textrm{s}$, respectively, and those for the negative first, second and third strokes are 3.46${\mu}\textrm{s}$, 3.15${\mu}\textrm{s}$ and 2.79${\mu}\textrm{s}$, respectively. The zero-crossing times of the electric fields for first return strokes range from about 10 to 80${\mu}\textrm{s}$. The mean zero-crossing times for subsequent return strokes are shorter than those for first lightning return strokes.

A Novel Unambiguous Correlation Function for Cosine-Phased BOC Signal Tracking (코사인 위상 이진 옵셋 반송파 신호 추적에 알맞은 새로운 비모호 상관함수)

  • Kim, Hongdeuk;Lee, Youngseok;Yoon, Seokho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38A no.5
    • /
    • pp.409-415
    • /
    • 2013
  • In this paper, we propose a correlation function using newly designed local signals for cosine-phased binary offset carrier (BOC) signal tracking. First, we divide a sub-carrier pulse over one pseudo random noise code period into multiple rectangular pulses, and subsequently, design novel local signals. Then, we obtain a correlation function with no side-peak based on a combination of correlations between the newly generated local signals and received cosine-phased BOC signal. From numerical results, it is confirmed that the proposed correlation function provides a tracking performance improvement over the conventional correlation functions in terms of the tracking error standard deviation.

Mutual Interference-resilient Vehicular Spread Spectrum Radar Using ZCZ Code (ZCZ 부호를 이용한 상호간섭에 강인한 차량용 확산대역 레이더 방식)

  • Kim, Bong-seok;Lee, Jonghun
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.11 no.1
    • /
    • pp.29-37
    • /
    • 2016
  • We propose vehicular spread spectrum (SS) radar robust to mutual interference using zero correlation zone (ZCZ) code. SS radar schemes have been employed for vehicular radar systems due to their outstanding correlation property. However, this superiority is based on a premise that timing among codes is completely synchronized. In the practical driving environment, timing mismatch among radar signals is inevitable because the radar signals of several vehicles are independently transmitted at each different location and each timing and thus each radar signal is received at different timing. This timing offset is the main cause of orthogonality destruction among codes and thus radar signals from other vehicles become mutual interference. In order to solve this problem, we find out the new property of ZCZ code which maintains the complete orthogonality except to timing offset corresponding to chips (pulses) of multiple of 4 and employ ZCZ code to SS radar systems. Simulation results show the proposed scheme achieve better performance compared with the conventional SS radar scheme using pseudo code or gold code.

Accuracy Improvement Scheme for Location Awareness based on UWB system (UWB 기반 위치인식 정확도 향상 기법)

  • Choi, Young-Hoon;Bae, Jung-Nam;Kim, Jin-Young
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.11 no.2
    • /
    • pp.231-236
    • /
    • 2011
  • In recent years, LBS(Location Based Service) is applied in many different fields. Therefore, various location-aware schemes have been studied. In the location awareness system using time dependent algorithm, TOA(Time of Arrival) or TDOA(Time Difference of Arrival) algorithm, distortion of a signal by AWGN(Additive White Gaussian Noise) and multi-path effects cause the degradation of location awareness performance. In this paper, the unexpected noise is eliminated by averaging multiple pulses in order to overcome the degradation of performance. Also, we research the technique for improving the performance of the location awareness by detecting direct-path signal with adjusting threshold.

Effects of Inoculum Level and Pressure Pulse on the Inactivation of Clostridium sporogenes Spores by Pressure-Assisted Thermal Processing

  • Ahn, Ju-Hee;Balasubramaniam, V.M.
    • Journal of Microbiology and Biotechnology
    • /
    • v.17 no.4
    • /
    • pp.616-623
    • /
    • 2007
  • The effects of initial concentration and pulsed pressurization on the inactivation of Clostridium sporogenes spores suspended in deionized water were determined during thermal processing $(TP;\;105^{\circ}C,\;0.1MPa)$ and pressure-assisted thermal processing $(PATP;\;105^{\circ}C\;and\;700MPa)$ treatments for 40 min and 5min holding times, respectively. Different inoculum levels $(10^4,\;10^6\;and\;10^8CFU/ml)$ of C. sporogenes spores suspended in deionized water were treated at $105^{\circ}C$ under 700MPa with single, double, and triple pulses. Thermally treated samples served as control. No statistical significances (p>0.05) were observed among all different inoculum levels during the thermal treatment, whereas the inactivation rates $(k_1\;and\;k_2)$ were decreased with increasing the initial concentrations of C. sporogenes spores during the PATP treatments. Double- and triple-pulsed pressurization reduced more effectively the number of C. sporogenes spores than single-pulse pressurization. The study shows that the spore clumps formed during the PATP may lead to an increase in pressure-thermal resistance, and multiple-pulsed pressurization can be more effective in inactivating bacterial spores. The results provide an interesting insight on the spore inactivation mechanisms with regard to inoculum level and pulsed pressurization.

Establishing Best Power Transmission Path using Receiver Based on the Received Signal Strength

  • Eom, Jeongsook;Son, Heedong;Park, Yongwan
    • Journal of Internet Computing and Services
    • /
    • v.18 no.6
    • /
    • pp.15-23
    • /
    • 2017
  • Wireless power transmission (WPT) for wireless charging is currently attracting much attention as a promising approach to miniaturize batteries and increase the maximum total range of an electric vehicle. The main advantage of the laser power beam (LPB) approach is its high power transmission efficiency (PTE) over long distance. In this paper, we present the design of a laser power beam based WPT system, which has a best WPT channel selection technique at the receiver end when multiple power transmitters and single power receiver are operated simultaneously. The transmitters send their transmission channel information via optically modulated laser pulses. The receiver uses the received signal strength indicator and digitized data to choose an optimum power transmission path. We modeled a vertical multi-junction photovoltaic cell array, and conducted an experiment and simulation to test the feasibility of this system. From the experimental result, the standard deviation between the mathematical model and the measured values of normalized energy distribution is 0.0052. The error between the mathematical model and measured values are acceptable, thus the validity of the model is verified.