• Title/Summary/Keyword: Multiple Mode Control

Search Result 253, Processing Time 0.026 seconds

Receiver Design for OFDM based Wireless LAN and Its Performance Evaluation in Mobile Environment (이동 환경에서 OFDM 기반 무선랜의 수신을 위한 수신기 설계 및 성능 평가)

  • Seo, Kang-Woon;Yoon, Seok-Hyun;Kim, Baek-Hyun;Kim, Yong-Kyu
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.48 no.11
    • /
    • pp.1-8
    • /
    • 2011
  • In this paper, we study receiver design issue to apply the OFDM based WLAN specification, such as 802.11p, to the communications in high speed mobile environment, e.g., for the ICT based railroad control on a train having its speed up to 300 km/hr. To successfully apply the existing WLAN specifications without modifying its transmission format, the performance at the receiver will solely depends on the channel estimation performance if we ignore the affect of frequency offset With a speed of multiple hundred km/hr, the channel estimation using only the preamble will not provide enough precision since the channel changes so fast. Therefore, in this paper, taking the high mobility into account, we focus on the design of decision directed channel estimation and equalization techniques and perform simulations to evaluate and compare their performances and to finally confirm the applicability of the existing WLAN specification to the systems with very high mobility.

Docosahexaenoic acid reduces adenosine triphosphate-induced calcium influx via inhibition of store-operated calcium channels and enhances baseline endothelial nitric oxide synthase phosphorylation in human endothelial cells

  • Vu, Thom Thi;Dieterich, Peter;Vu, Thu Thi;Deussen, Andreas
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.23 no.5
    • /
    • pp.345-356
    • /
    • 2019
  • Docosahexaenoic acid (DHA), an omega-3-fatty acid, modulates multiple cellular functions. In this study, we addressed the effects of DHA on human umbilical vein endothelial cell calcium transient and endothelial nitric oxide synthase (eNOS) phosphorylation under control and adenosine triphosphate (ATP, $100{\mu}M$) stimulated conditions. Cells were treated for 48 h with DHA concentrations from 3 to $50{\mu}M$. Calcium transient was measured using the fluorescent dye Fura-2-AM and eNOS phosphorylation was addressed by western blot. DHA dose-dependently reduced the ATP stimulated $Ca^{2+}$-transient. This effect was preserved in the presence of BAPTA (10 and $20{\mu}M$) which chelated the intracellular calcium, but eliminated after withdrawal of extracellular calcium, application of 2-aminoethoxy-diphenylborane ($75{\mu}M$) to inhibit store-operated calcium channel or thapsigargin ($2{\mu}M$) to delete calcium store. In addition, DHA ($12{\mu}M$) increased ser1177/thr495 phosphorylation of eNOS under baseline conditions but had no significant effect on this ratio under conditions of ATP stimulation. In conclusion, DHA dose-dependently inhibited the ATP-induced calcium transient, probably via store-operated calcium channels. Furthermore, DHA changed eNOS phosphorylation suggesting activation of the enzyme. Hence, DHA may shift the regulation of eNOS away from a $Ca^{2+}$ activated mode to a preferentially controlled phosphorylation mode.

Development and Validation of an LC-MS/MS Method for Determination of Damaurone D in Rat Plasma and its Application to Pharmacokinetic Study in Rats

  • Lee, Wonpyo;Song, Im-Sook;Han, Young Taek;Choi, Min-Koo
    • Mass Spectrometry Letters
    • /
    • v.10 no.1
    • /
    • pp.38-42
    • /
    • 2019
  • Damaurone D belongs to the genus Rosa and is a traditional medicinal product used for the treatment of depression, inflammation, and infectious diseases. The purpose of this study was to develop a simple liquid chromatography-tandem mass spectrometry method for the detection of damaurone D in rat plasma and to demonstrate its application in pharmacokinetic studies. Damaurone D and berberine (internal standard) were extracted with acetonitrile using a protein precipitation method. Mass transition was monitored in multiple reaction monitoring mode at m/z $323.2{\rightarrow}267.0$ for damaurone D and m/z $336.1{\rightarrow}320.0$ for berberine in positive ion mode. Analytical validation was conducted by evaluating the specificity, linearity, accuracy, precision, matrix effect, extraction recovery, and stability. The calibration curves were linear over 2-1000 ng/mL. The intra- and inter-day precision and accuracy of quality control samples were 4.79-13.33% and 86.23-102.75%, respectively. The matrix effect and extraction recovery were 96.11-98.47% and 96.11-102.25%, respectively. In the pharmacokinetic study after intravenous administration of damaurone D at a dose of 3 mg/kg in rats, the area under the curve and clearance of damaurone D in rat plasma were $16750.26{\pm}2676.10min{\cdot}ng/mL$ and $182.44{\pm}31.36mL/min/kg$, respectively.

Comparison of semi-active and passive tuned mass damper systems for vibration control of a wind turbine

  • Lalonde, Eric R.;Dai, Kaoshan;Bitsuamlak, Girma;Lu, Wensheng;Zhao, Zhi
    • Wind and Structures
    • /
    • v.30 no.6
    • /
    • pp.663-678
    • /
    • 2020
  • Robust semi-active vibration control of wind turbines using tuned mass dampers (TMDs) is a promising technique. This study investigates a 1.5 megawatt wind turbine controlled by eight different types of tuned mass damper systems of equal mass: a passive TMD, a semi-active varying-spring TMD, a semi-active varying-damper TMD, a semi-active varying-damper-and-spring TMD, as well as these four damper systems paired with an additional smaller passive TMD near the mid-point of the tower. The mechanism and controllers for each of these TMD systems are explained, such as employing magnetorheological dampers for the varying-damper TMD cases. The turbine is modelled as a lumped-mass 3D finite element model. The uncontrolled and controlled turbines are subjected to loading and operational cases including service wind loads on operational turbines, seismic loading with service wind on operational turbines, and high-intensity storm wind loads on parked turbines. The displacement and acceleration responses of the tower at the first and second mode shape maxima were used as the performance indicators. Ultimately, it was found that while all the semi-active TMD systems outperformed the passive systems, it was the semi-active varying-damper-and-spring system that was found to be the most effective overall - capable of controlling vibrations about as effectively with only half the mass as a passive TMD. It was also shown that by reducing the mass of the TMD and adding a second smaller TMD below, the vibrations near the mid-point could be greatly reduced at the cost of slightly increased vibrations at the tower top.

A Ka-band 10 W Power Amplifier Module utilizing Pulse Timing Control (펄스 타이밍 제어를 활용한 Ka-대역 10 W 전력증폭기 모듈)

  • Jang, Seok-Hyun;Kim, Kyeong-Hak;Kwon, Tae-Min;Kim, Dong-Wook
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.46 no.12
    • /
    • pp.14-21
    • /
    • 2009
  • In this paper, a Ka-band 10 W power amplifier module with seven power MMIC bare dies is designed and fabricated using MIC technology which combines multiple MMIC chips on a thin film substrate. Modified Wilkinson power dividers/combiners and CBFGCPW-Microstrip transitions for suppressing resonance and reducing connection loss are utilized for high-gain and high-power millimeter wave modules. A new TTL pulse timing control scheme is proposed to improve output power degradation due to large bypass capacitors in the gate bias circuit. Pulse-mode operation time is extended more than 200 nsec and output power increase of 0.62 W is achieved by applying the proposed scheme to the Ka-band 10 W power amplifier module operating in the pulsed condition of 10 kHz and $5\;{\mu}sec$. The implemented power amplifier module shows a power gain of 59.5 dB and an output power of 11.89 W.

Quantitation of L-carnitine in plasma by electrospray ionization tandem mass spectrometry (ESI/MS/MS를 이용한 혈장 중 카르니틴 정량분석)

  • Kang, Seung Woo;Kim, Ho Hyun;Lee, Kyung Ryul;Yoon, Hye-Ran
    • Analytical Science and Technology
    • /
    • v.18 no.2
    • /
    • pp.163-167
    • /
    • 2005
  • In this study, a novel analytical method has been developed for the rapid determination of L-carnitine in human plasma using electrospray ionization tandem mass spectrometry. Free carnitine (FC) was analyzed after extraction with 80% methanol and total carnitine (TC) was analyzed after hydrolysis and extraction. Acyl carnitine (AC) was subtracted FC from TC. Analytical methods used multiple reaction monitoring (MRM) scan modes. A correlation coefficient of linear regression ($r^2$) was 0.9995, recovery was 97%, reproducibility was less than 10%, and limit of detection (LOD) was $0.0016{\mu}mol/L$. This method reduced sample preparation time and showed high resolution and good reproducibility compared to that with liquid chromatographic methods. Normal control showed AC was lower than FC. Clinical management of patients with inborn error of metabolism showed FC was lower than AC. Thus, carnitine fraction level was very important to monitoring patients with metabolic disorder.

Real-Time Multiple Face Detection Using Active illumination (능동적 조명을 이용한 실시간 복합 얼굴 검출)

  • 한준희;심재창;설증보;나상동;배철수
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.05a
    • /
    • pp.155-160
    • /
    • 2003
  • This paper presents a multiple face detector based on a robust pupil detection technique. The pupil detector uses active illumination that exploits the retro-reflectivity property of eyes to facilitate detection. The detection range of this method is appropriate for interactive desktop and kiosk applications. Once the location of the pupil candidates are computed, the candidates are filtered and grouped into pairs that correspond to faces using heuristic rules. To demonstrate the robustness of the face detection technique, a dual mode face tracker was developed, which is initialized with the most salient detected face. Recursive estimators are used to guarantee the stability of the process and combine the measurements from the multi-face detector and a feature correlation tracker. The estimated position of the face is used to control a pan-tilt servo mechanism in real-time, that moves the camera to keep the tracked face always centered in the image.

  • PDF

Development of Tracking Equipment for Real­Time Multiple Face Detection (실시간 복합 얼굴 검출을 위한 추적 장치 개발)

  • 나상동;송선희;나하선;김천석;배철수
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.8
    • /
    • pp.1823-1830
    • /
    • 2003
  • This paper presents a multiple face detector based on a robust pupil detection technique. The pupil detector uses active illumination that exploits the retro­reflectivity property of eyes to facilitate detection. The detection range of this method is appropriate for interactive desktop and kiosk applications. Once the location of the pupil candidates are computed, the candidates are filtered and grouped into pairs that correspond to faces using heuristic rules. To demonstrate the robustness of the face detection technique, a dual mode face tracker was developed, which is initialized with the most salient detected face. Recursive estimators are used to guarantee the stability of the process and combine the measurements from the multi­face detector and a feature correlation tracker. The estimated position of the face is used to control a pan­tilt servo mechanism in real­time, that moves the camera to keep the tracked face always centered in the image.

Electronic Ballast of High Power Factor Using SEPIC Converter for Electrodeless Fluorescent Lamps (SEPIC 컨버터를 이용한 무전극형광램프용 고역률 전자식 안정기)

  • 장도현;주형종;권명일
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.3
    • /
    • pp.285-293
    • /
    • 2004
  • In this Paper the electronic ballast using the SEPIC(Single Ended Primary Inductor Converter) converter for the multiple electrodeless fluorescent lamps is proposed, which has the structure of the active PFC and self oscillating function. The SEPIC converter system has the characteristics of the power factor with low input current harmonic distortion. The proposed control method is based on the aveage-current-mode using the dedicated integrated circuit UC3854. The proposed electronic ballast has the reduction effect for the energy and manufacturing cost because it is designed for tripple electrodeless fluorescent lamps. The experimental results shows that the power factor is higher and the THD is lower.

Performance Analysis of Directional CSMA/CA for IEEE 802.15.3c under Saturation Environments

  • Kim, Mee-Joung;Kim, Yong-Sang;Lee, Woo-Yong
    • ETRI Journal
    • /
    • v.34 no.1
    • /
    • pp.24-34
    • /
    • 2012
  • In this paper, the directional carrier sense multiple access/collision avoidance (CSMA/CA) protocol in the immediate acknowledgement mode for IEEE 802.15.3c is analyzed under saturation environments. For the analysis, a sensing region and an exclusive region with a directional antenna are computed probabilistically and a Markov chain model in which the features of IEEE 802.15.3c and the effects of using directional antennas are incorporated is analyzed. An algorithm to find the maximal number of concurrently transmittable frames is proposed. The system throughput and the average transmission delay are obtained in closed forms. The numerical results show the impact of directional antennas on the CSMA/CA media access control (MAC) protocol. For instance, the throughput with a small beamwidth of antenna is more than ten times larger than that for an omnidirectional antenna. The overall analysis is verified by a simulation. The obtained results will be helpful in developing an MAC protocol for enhancing the performance of mmWave wireless personal area networks.