• Title/Summary/Keyword: Multi-view Camera System

Search Result 71, Processing Time 0.029 seconds

Development of a Reliable Real-time 3D Reconstruction System for Tiny Defects on Steel Surfaces (금속 표면 미세 결함에 대한 신뢰성 있는 실시간 3차원 형상 추출 시스템 개발)

  • Jang, Yu Jin;Lee, Joo Seob
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.12
    • /
    • pp.1061-1066
    • /
    • 2013
  • In the steel industry, the detection of tiny defects including its 3D characteristics on steel surfaces is very important from the point of view of quality control. A multi-spectral photometric stereo method is an attractive scheme because the shape of the defect can be obtained based on the images which are acquired at the same time by using a multi-channel camera. Moreover, the calculation time required for this scheme can be greatly reduced for real-time application with the aid of a GPU (Graphic Processing Unit). Although a more reliable shape reconstruction of defects can be possible when the numbers of available images are increased, it is not an easy task to construct a camera system which has more than 3 channels in the visible light range. In this paper, a new 6-channel camera system, which can distinguish the vertical/horizontal linearly polarized lights of RGB light sources, was developed by adopting two 3-CCD cameras and two polarized lenses based on the fact that the polarized light is preserved on the steel surface. The photometric stereo scheme with 6 images was accelerated by using a GPU, and the performance of the proposed system was validated through experiments.

Real-time Tracking and Identification for Multi-Camera Surveillance System

  • Hong, Yo-Hoon;Song, Seung June;Rho, Jungkyu
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.10 no.1
    • /
    • pp.16-22
    • /
    • 2018
  • This paper presents a solution for personal profiling system based on user-oriented tracking. Here, we introduce a new way to identify and track humans by using two types of cameras: dome and face camera. Dome camera has a wide view angle so that it is suitable for tracking human movement in large area. However, it is difficult to identify a person only by using dome camera because it only sees the target from above. Thus, face camera is employed to obtain facial information for identifying a person. In addition, we also propose a new mechanism to locate human on targeted location by using grid-cell system. These result in a system which has the capability of maintaining human identity and tracking human activity (movement) effectively.

Face Tracking for Multi-view Display System (다시점 영상 시스템을 위한 얼굴 추적)

  • Han, Chung-Shin;Jang, Se-Hoon;Bae, Jin-Woo;Yoo, Ji-Sang
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.2C
    • /
    • pp.16-24
    • /
    • 2005
  • In this paper, we proposed a face tracking algorithm for a viewpoint adaptive multi-view synthesis system. The original scene captured by a depth camera contains a texture image and 8 bit gray-scale depth map. From this original image, multi-view images can be synthesized which correspond to viewer's position by using geometrical transformation such as a rotation and a translation. The proposed face tracking technique gives a motion parallax cue by different viewpoints and view angles. In the proposed algorithm, tracking of viewer's dominant face initially established from camera by using statistical characteristics of face colors and deformable templates is done. As a result, we can provide motion parallax cue by detecting viewer's dominant face area and tracking it even under a heterogeneous background and can successfully display the synthesized sequences.

Enlargement of Field-of-View (FOV) of the CCD Camera by the Current Adjustment of the Projection Lens System in the KBSI-HVEM (KBSI-HVEM 투사렌즈 전류제어에 의한 CCD Camera의 Field of View(FOV) 확장)

  • Kim, Young-Min;Shim, Hyo-Sik;Kim, Youn-Joong
    • Applied Microscopy
    • /
    • v.35 no.4
    • /
    • pp.98-104
    • /
    • 2005
  • A FOV (field-of-view) of the HV-MSC (high voltage multi-scan CCD, $1024{\times}1024$ pixels) camera mounted in the post-column HV-GIF (high voltage gatan image filter) has been drastically enlarged by the projection lens current adjustment. An imaging area of the HV-MSC camera obtained at the lowest magnification (2,000x) is $112{\mu}m^2$ which corresponds to the recording area of the film at the magnification of 8,800x, while the achievable recording area is only $0.43{\mu}m^2$ at the same magnification without this technique. Ignoring the image distortion of less than 5%, we have designed an on-site reference graph to estimate projection lens currents for microscope magnifications above 8,800x, where the recording area on the HVMSC is same as that on the film.

VHOE-based Multi-view Stereoscopic 3D Display System (VHOE광학판을 이용한 다시점 스테레오 입체영상 디스플레이 시스템)

  • Cho, Byung-Chul;Koo, Jung-Sik;Kim, Seung-Cheol;Kim, Eun-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.04b
    • /
    • pp.42-44
    • /
    • 2002
  • The experimental model of the 8-view stereoscopic display system using the photopolymer-based VHOE is proposed. At first, the VHOE is implemented by angle-multiplexed recording of 8-view's diffraction gratings using the optimized exposure-time scheduling scheme in the photopolymer (HRF-150-100) and then. the VHOE-based 8-view stereoscopic display system is implemented by sequentially synchronizing the incident angles of the reference beam of the VHOE with the 8-view stereo images on the LCD pannel. Accordingly, from some experimental results using 8-view images generated by the toed-in stereo camera system, it is found that 8-view stereo images can be diffracted to eight different directions time-sequentially and there is some disparity between the stereo images.

  • PDF

Multi-tracer Imaging of a Compton Camera (다중 추적자 영상을 위한 컴프턴 카메라)

  • Kim, Soo Mee
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.18-27
    • /
    • 2015
  • Since a Compton camera has high detection sensitivity due to electronic collimation and a good energy resolution, it is a potential imaging system for nuclear medicine. In this study, we investigated the feasibility of a Compton camera for multi-tracer imaging and proposed a rotating Compton camera to satisfy Orlov's condition for 3D imaging. Two software phantoms of 140 and 511 keV radiation sources were used for Monte-Carlo simulation and then the simulation data were reconstructed by listmode ordered subset expectation maximization to evaluate the capability of multi-tracer imaging in a Compton camera. And the Compton camera rotating around the object was proposed and tested with different rotation angle steps for improving the limited coverage of the fixed conventional Compton camera over the field-of-view in terms of histogram of angles in spherical coordinates. The simulation data showed the separate 140 and 511 keV images from simultaneous multi-tracer detection in both 2D and 3D imaging and the number of valid projection lines on the conical surfaces was inversely proportional to the decrease of rotation angle. Considering computation load and proper number of projection lines on the conical surface, the rotation angle of 30 degree was sufficient for 3D imaging of the Compton camera in terms of 26 min of computation time and 5 million of detected event number and the increased detection time can be solved with multiple Compton camera system. The Compton camera proposed in this study can be effective system for multi-tracer imaging and is a potential system for development of various disease diagnosis and therapy approaches.

Head Fixed Type Multi-Focus Display System Using Galvano-Scanner and DMD(Digital Micro-Mirror Device) (갈바노 스캐너와 DMD(Digital Micro-mirror Device)를 이용한 두부 고정형 다초점 디스플레이 시스템)

  • Kim, Dong-Wook;Kwon, Yong-Moo;Kim, Sung-Kyu
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.10B
    • /
    • pp.1117-1123
    • /
    • 2009
  • Head fixed type multi-focus display system using Galvano-scanner and DMD(Digital Micro-mirror Device), which is able to perfectly accommodate, can solve eye fatigue due to conflict between convergence eye movement and accommodation action in stereoscopic display. This system is able to accommodate through making convergence point about each view point and offering it in front of observer's pupil by using laser scanning method. In this paper, we analyzed laser scanning method of this multi-focus display system. And multi-focus display system based on this analysis was made, which showed that focus adjustment was possible through video camera. As a result, formation principle of view point of multi-focus system by laser scanning method was verified.

Design and Implementation of PC-Mechanic Education Application System Using Image Processing (영상처리를 이용한 PC 내부구조 학습 어플리케이션 설계 및 구현)

  • Kim, Won-Jin;Kim, Hyung-Ook;Jo, Sung-Eun;Jang, Soo-Jeong;Moon, Il-Young
    • The Journal of Korean Institute for Practical Engineering Education
    • /
    • v.3 no.2
    • /
    • pp.93-99
    • /
    • 2011
  • We introduce the application what using the MultiTouch-Table of the PC-mechanic Certification. Thesedays, People does't use the Mouse and Keyboard and use people gesture. We introduce Graphic and Image by addition. Theseday, MultiTouch-Table is so famous. We use it the multitouch-table to on 3D Maxs and C#. We help them to get the certification using the component Scale and Drags through the camera view and then include the PC-Mechanic question of domestic.

  • PDF

Multi-Camera Vision System for Tele-Robotics

  • Park, Changhwn;Kohtaro Ohba;Park, Kyihwan;Sayaka Odano;Hisayaki Sasaki;Nakyoung Chong;Tetsuo Kotoku;Kazuo Tanie
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.25.6-25
    • /
    • 2001
  • A new monitoring system is proposed to give direct visual information of the remote site when working with a tele-operation system. In order to have a similar behavior of a human when he is inspecting an object, multiple cameras that have different view point are attached around the robot hand and are switched on and elf according to the operator´s motion such as joystick manipulation or operator´s head movement. The performance of the system is estimated by performing comparison experiments among single camera (SC) vision system, head mount display (HMD)system and proposed multiple camera (MC) vision system by applying a task to several examines. The reality, depth feeling and controllability are estimated for the examines ...

  • PDF

Non Uniformity Error of MSC (Multi Spectral Camera) System

  • Jang YoungJun;Yong SangSoon;Kang KeumSil;Kim JungAh;Kang SungDuk;Youn HeongSik
    • Proceedings of the KSRS Conference
    • /
    • 2004.10a
    • /
    • pp.432-435
    • /
    • 2004
  • MSC (Multi Spectral Camera) system is a remote sensing payload to obtain high resolution ground image. In this application, uniformity characteristic is important as well as GSD (Ground Resolved Distance) and SNR (Signal to Noise Ratio). MSC image chain is consisted of OM (Optical Module), CCD, Video processor, NUC and DCSU (Data Compression and Storage Unit). Each block makes and corrects MSC's nonuniformity response. This paper shows the cause of nonuniformity error and the correction scheme of MSC system from the electronic point of view.

  • PDF