• 제목/요약/키워드: Multi-temperature

검색결과 2,243건 처리시간 0.029초

저온 주사 레이저 및 홀소자 현미경을 이용한 YBCO 초전도 선재의 국소적 임계 온도 및 전류 밀도 분포 분석 (Distribution Analysis of the Local Critical Temperature and Current Density in YBCO Coated Conductors using Low-temperature Scanning Laser and Hall Probe Microscopy)

  • 박상국;조보람;박희연;이형철
    • Progress in Superconductivity
    • /
    • 제13권1호
    • /
    • pp.28-33
    • /
    • 2011
  • Distribution of the local critical temperature and current density in YBCO coated conductors were analyzed using Low-temperature Scanning Laser and Hall Probe Microscopy (LTSLHPM). We prepared YBCO coated conductors of various bridge types to study the spatial distribution of the critical temperature and the current density in single and multi bridges. LTSLHPM system was modified for detailed linescan or two-dimensional scan both scanning laser and scanning Hall probe method simultaneously. We analyzed the local critical temperature of single and multi bridges from series of several linescans of scanning laser microscopy. We also investigated local current density and hysteresis curve of single bridge from experimental results of scanning Hall probe microscopy.

Analysis of Heating Characteristics Using Aluminum Multi-Layer Curtain for Protected Horticulture Greenhouses

  • Park, Bum-Soon;Kang, Tae-Hwan;Han, Chung-Su
    • Journal of Biosystems Engineering
    • /
    • 제40권3호
    • /
    • pp.193-200
    • /
    • 2015
  • Purpose: The purpose of this study was to investigate the energy saving effects and characteristics of plant growth in a greenhouse with an aluminum multi-layer curtain compared to a greenhouse with non-woven fabric. Method: The dimensions of both greenhouses $43m{\times}3.6m{\times}8m(L{\times}H{\times}W)$, and both used hot air heater systems for maintaining a constant temperature $15^{\circ}C$. Heating characteristics such as solar intensity, inside and ambient temperatures, and fuel consumption were measured and analyzed. Results: The changes of average temperature of both greenhouses during a 15-days (December 06 - 20) showed approximately $26^{\circ}C$ at around 2 pm when the ambient temperature was highest. The greenhouses were set by the heater to keep a temperature of $15^{\circ}C$ from 4 pm to 8 am the following day. The average heat loss (for 15 days) from the greenhouse with an aluminum multi-layer curtain was $161.2-268.4kJ/m^2{\cdot}h$ during the daytime and $152.3-198.1kJ/m^2{\cdot}h$ during the nighttime. The average heat loss (for 15 days) from the greenhouse with non-woven fabric was $155.7-258.9kJ/m^2{\cdot}h$ during the daytime and $144.9-207.0kJ/m^2{\cdot}h$ during the nighttime. The total heat loss (for one day) from the non-woven fabric system was $7,960kJ/m^2$($2,876kJ/m^2$ during the daytime, $5,084kJ/m^2$ during the nighttime). The heat supply over 36 days for the non-woven fabric system was higher than the aluminum multi-layer curtain system by $616.3-65,079.4kJ/m^2$. Conclusions: These results suggest that a greenhouse with an aluminum multi-layer curtain could save energy usage by 35% over a greenhouse with non-woven fabric.

Leak Evaluation for Power Plant Valve Using Multi-Measuring Method

  • Lee, Sang-Guk;Park, Jong-Hyuck;Kim, Young-Bum
    • 비파괴검사학회지
    • /
    • 제28권6호
    • /
    • pp.469-476
    • /
    • 2008
  • Condition based maintenance(CBM) for the preventive diagnosis of important equipments related to safety or accident in power plant is essential by using the suitable methods based on actual power plant conditions. To improve the reliability and accuracy of the measured value at the minute leak situation, and also to monitor continuously internal leak condition of power plant valve, the development of a diagnosis and monitoring technique using multi-measuring method should be performed urgently. This study was conducted to estimate the feasibility of multi-measuring method using three different methods such as acoustic emission(AE) method, thermal image measurement and temperature difference$({\Delta}T)$ measurement that are applicable to internal leak diagnosis for the power plant valve. From the experimental results, it was suggested that the multi-measuring method could be an effective way to precisely diagnose and evaluate internal leak situation of valve.

다성분연료 분무에 있어서 증발과정의 해석모델 제안 (Propose an Analysis Model of Evaporation Process in Multi-Component Fuel Spray)

  • 염정국;전중지지
    • 대한기계학회논문집B
    • /
    • 제33권5호
    • /
    • pp.373-380
    • /
    • 2009
  • The evaporation process of multi-component fuel is different from one of a single component, because the properties of each component affects among the components. In actual engine, the spatial distribution of fuel vapor concentration dominates auto-ignition and initial combustion, and depends on the volatility and diffusivity of each component fuel contained in the multi-component fuel. Then, this study proposes a simplified numerical scheme for analysis of evaporation process of multi-component fuel sprays. Evaporation process is calculated by KIVA-II code based on the simple two-phases region that is approximated by modified saturated liquid-vapor line, which was obtained by connecting the 50% distillation temperature for each component under several pressure fields. Consequently, it can be quantitatively simulated that vapor of low boiling fuel component mostly exists around nozzle and spray tip region, the high boiling duel component, on the other hand, mostly appears near the spray tip.

다단 전류도입선 해석 (Study of Multi-Step Current Lead)

  • 문정수;설승윤
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.379-384
    • /
    • 2000
  • High-Tc superconducting current leads with multi-step and continually varied cross-sectional area are studied to reduce heat leak into cryostat and material use. Assuming conduction-cooled lead the cross-sectional area is reduced along the heat flow direction according to the increase of critical current density which increases with decreasing temperature. In this study, we also analyze the multi-step cross-sectional area High-Tc current leads. The multi-st데 current leads changes the cross-sectional area to have constant safety-factor at changed section. The heat leak into cryostat, total voume, safety-factor and the temperature profiles are compared to those of the constant safety-factor current leads. The developed methods are applied to the Bi-2223 superconductor sheathed with Ag-Au alloy.

  • PDF

열탄성 거동을 나타내는 다층 실린더의 최적설계 (Optimum Design of Thermoelastic Multi-Layer Cylindrical Tube)

  • 조희근;박영원
    • 한국군사과학기술학회지
    • /
    • 제3권2호
    • /
    • pp.179-188
    • /
    • 2000
  • Multi-disciplinary optimization design concept can provide a solution to many engineering problems. In the field of structural analysis, much development of size or topology optimization has been achieved in the application of research. This paper demonstrates an optimum design of a multi-layer cylindrical tube which behaves thermoelastically. A multi-layer cylindrical tube that has several different material properties at each layer is optimized within allowable stress and temperature range when mechanical and thermal loads are applied simultaneously. When thermal loads are applied to a multi-layer tube, stress phenomena become complicated due to each layer's thermal expansion and the layer thicknesses. Factors like temperature; stress; and material thermal thicknesses of each tube layer are very difficult undertaking. To analyze these problems using an efficient and precise method, the optimization theories are adopted to perform thermoelastic finite element analysis.

  • PDF

HVAC 시스템의 중복고장 검출을 위한 실험적 연구 (An Experimental Study on Multi-Fault Detection and Diagnosis Analysis of HVAC System)

  • 조성환;홍영주;양훈철;안병천
    • 설비공학논문집
    • /
    • 제16권10호
    • /
    • pp.932-941
    • /
    • 2004
  • The objective of this study is to detect the multi-fault of HVAC system using a new pattern classification technique. To classify the effect of single-fault in determining the pattern, supply air temperature, OA-damper, supply fan, and air flowrate were chosen as experimental parameters. The combination of supply temperature, flow rate, supply fan and OA-damper were chosen as multi-fault conditions. Three kinds of patterns were introduced in the analysis of multi-fault problem. To solve multi-fault problem, the new pattern classification technique using residual ratio analysis was introduced to detect the multi-fault as well as single-fault. The residual ratio could diagnose single-fault or multi-fault into several patterns.

손 끝 온도변화가 젊은 성인의 다중 손가락 동작에 미치는 효과 (Effect of Fingertip Temperature on Multi-finger Actions in Young Adults)

  • Shin, Narae;Xu, Dayuan;Song, Jun Kyung;Park, Jaebum
    • 한국운동역학회지
    • /
    • 제29권3호
    • /
    • pp.157-166
    • /
    • 2019
  • Objective: This study examined the effects of stimulating fingertip temperature on the patterns of force sharing and stability properties during multi-finger force production tasks. Method: 9 adult subjects (male: 3, female: 6, age: $26.11{\pm}4.01yrs$, height: $169.22{\pm}5.97cm$, weight: $61.44{\pm}11.27kg$) participated in this study. The experiment consisted of three blocks: 1) maximal voluntary contraction (MVC) task, 2) single-finger ramp task to quantify enslaving (i.e., unintended force production by non-task fingers), and 3) 12 trials of multi-finger steady-state force production task at 20% MVC. There were three temperature conditions including body-temperature (i.e., control condition), $40^{\circ}C$, and $43^{\circ}C$, and the stimulation was given to the index finger only for all experimental conditions. Results: There were no significant differences in the MVC forces, enslaving, and the accuracy of performance during the steady-state task between the conditions. However, the share of stimulated index finger force increased with the index fingertip temperature, while the share of middle finger force decreased. Also, the coefficient of variation of both index and middle finger forces over repetitive trials increased with the index fingertip temperature. Under the framework of the uncontrolled manifold (UCM) hypothesis used to quantify indices of multi-finger synergies (i.e., stability property) stabilizing total force during the steady-state task, the two variance components within the UCM analysis increased together with the fingertip temperature, while no changes in the synergy indices between the conditions. Conclusion: The current results showed that fingertip temperature stimulation only to index finger does not affect to muscle force production capability of multi-finger, independence of individual fingers, and force production accuracy by the involvement of all four fingers. The effect of fingertip temperature on the sharing pattern and force variation may be due to diffuse reflex effects of the induced afferent activity on alpha-motoneuronal pools. However, the unchanged stability properties may be the reflection of the active error compensation strategies by non-stimulated finger actions.

동적기계분석장치를 이용한 탄소섬유/에폭시 복합재의 장기 성능 예측 (Long-Term Performance Prediction of Carbon Fiber Reinforced Composites Using Dynamic Mechanical Analyzer)

  • 차재호;윤성호
    • Composites Research
    • /
    • 제32권1호
    • /
    • pp.78-84
    • /
    • 2019
  • 본 연구에서는 동적기계분석장치(dynamic mechanical analysis, DMA)와 시간-온도 중첩법(time-temperature superposition, TTS)을 이용하여 탄소섬유/에폭시 복합재의 장기 성능을 예측하고자 하였다. 이를 위해 단일 진동수 시험, 다중 진동수 시험, 크리프 TTS 시험을 수행하였다. 단일 진동수(single-frequency) 시험과 다중 진동수(multi-frequency) 시험에서는 $-30^{\circ}C$에서 $240^{\circ}C$까지 $2^{\circ}C/min$로 온도를 상승시키면서 $20{\mu}m$ 진폭의 사인(sine) 파형의 하중을 가하였으며 다중 진동수 시험에 적용된 진동수는 0.316, 1, 3.16, 10, 31.6 Hz이다. 크리프 TTS 시험에서는 $-30^{\circ}C$에서 $230^{\circ}C$까지 $10^{\circ}C$마다 15 MPa의 응력을 10분 동안 가하였다. 단일 진동수 시험을 통해 유리전이온도를 구하였으며 다중 진동수 시험을 통해 진동수 별 유리전이온도에서 활성화 에너지와 온도 별 저장탄성계수 선도를 구하였다. 또한 아레니우스 식(Arrhenius equation)을 통해 얻은 이동 인자를 적용하여 기준 온도에 대한 마스터 선도를 얻었다. 또한 크리프 TTS 시험을 통해서는 크리프 컴플라이언스 선도를 구하고 직접 이동 기법을 이용하여 구한 이동 인자를 적용하여 기준 온도에 대한 마스터 선도도 얻었다. 이와 같은 과정을 통해 얻은 마스터 선도를 이용하면 주어진 환경 조건에 대한 탄소섬유강화 복합재의 장기 성능을 예측할 수 있다.

다관형 잠열축열장치의 축열특성연구 -물을 매체로 한 축열 및 방열과정 분석- (Study on the Thermal Storage Characteristics of a Multi-capsule type LTES System -Analysis for Heat Charging and Discharging Process for Water Flow-)

  • 김영복
    • Journal of Biosystems Engineering
    • /
    • 제19권1호
    • /
    • pp.62-69
    • /
    • 1994
  • This study was designed to seek information on the heat charging and discharging characteristics of a multi-capsule type LTES(Latent Heat of Fusion Thermal Energy Storage) system, and especially prediction equation of outlet water temperature from the system. During heat charging process, the water temperature in the LTES tank increased very slowly in comparison with a predicted one and was kept near the melting point of the PCM for about 25 minutes. During heat discharging process, the latent heat discharging period of the outlet water temperature became longer as the inlet water temperature became higher and/or mass flow rate became lower. The dimensionless temperature of the outlet water was predicted by linking three equations of ${\theta}=1.1Exp(-{\tau}/0.82)$, ${\theta}=-0.06{\tau}+0.3$, ${\theta}=0.8Exp(-{\tau}/1.4)$ ($r^2{\leq}0.88$) depending on discharging period regardless of mass flow rates on the case of the inlet water temperature at $21.5^{\circ}C$.

  • PDF