DOI QR코드

DOI QR Code

Analysis of Heating Characteristics Using Aluminum Multi-Layer Curtain for Protected Horticulture Greenhouses

  • Park, Bum-Soon (Department of Biosystems Engineering, Chungbuk National University) ;
  • Kang, Tae-Hwan (Major in Bio-Industry Mechanical Engineering, Kongju National University) ;
  • Han, Chung-Su (Department of Biosystems Engineering, Chungbuk National University)
  • Received : 2015.08.20
  • Accepted : 2015.08.26
  • Published : 2015.09.01

Abstract

Purpose: The purpose of this study was to investigate the energy saving effects and characteristics of plant growth in a greenhouse with an aluminum multi-layer curtain compared to a greenhouse with non-woven fabric. Method: The dimensions of both greenhouses $43m{\times}3.6m{\times}8m(L{\times}H{\times}W)$, and both used hot air heater systems for maintaining a constant temperature $15^{\circ}C$. Heating characteristics such as solar intensity, inside and ambient temperatures, and fuel consumption were measured and analyzed. Results: The changes of average temperature of both greenhouses during a 15-days (December 06 - 20) showed approximately $26^{\circ}C$ at around 2 pm when the ambient temperature was highest. The greenhouses were set by the heater to keep a temperature of $15^{\circ}C$ from 4 pm to 8 am the following day. The average heat loss (for 15 days) from the greenhouse with an aluminum multi-layer curtain was $161.2-268.4kJ/m^2{\cdot}h$ during the daytime and $152.3-198.1kJ/m^2{\cdot}h$ during the nighttime. The average heat loss (for 15 days) from the greenhouse with non-woven fabric was $155.7-258.9kJ/m^2{\cdot}h$ during the daytime and $144.9-207.0kJ/m^2{\cdot}h$ during the nighttime. The total heat loss (for one day) from the non-woven fabric system was $7,960kJ/m^2$($2,876kJ/m^2$ during the daytime, $5,084kJ/m^2$ during the nighttime). The heat supply over 36 days for the non-woven fabric system was higher than the aluminum multi-layer curtain system by $616.3-65,079.4kJ/m^2$. Conclusions: These results suggest that a greenhouse with an aluminum multi-layer curtain could save energy usage by 35% over a greenhouse with non-woven fabric.

Keywords

References

  1. Chang, Y. S., K. Y. Oh, S. H. Kim, J. G. Jeun, K. C. Kang and D. H. Chyoung. 1996. Study on the physical property of thermal curtains for greenhouse. Journal of Bio-Environment control 5(1):34-42 (In Korean).
  2. Cho, Y. B., H. K. Koh, M. K. Kim and Y. H. Kim. 1989. Analysis of nocturnal thermal insulation effect of thermal curtain in plastic greenhouse. Journal of Korean Solar Energy Society 9(1):22-29 (In Korean).
  3. Choi, I. H., S. S. Nam, D. H. Chung and B. S. Kwon. 2001. Effect of shade culture on fresh yield of garlic at vinyl house in winter. Korean Journal of Plant Resources 14(1):59-62 (In Korean).
  4. Kim, H. H., S. Y. Lee, H. Chun and Y. S. Kwon. 1998. Improvement of heat conservation in single-span type vinyl-house. Proceedings of the Korean Society for 1998 Bio-Environment Control Conference 168-173 (In Korean).
  5. Kim, Y. B., J. C. Park, M. R. Huh, S. Y. Lee and S. W. Jeong. 2007. Effectiveness of the aluminum thermal screens depending on the allocation type. Journal of Bio-Environment Control 16(4):284-290 (In Korean).
  6. Ko, K. D. 2009. Insulation effectiveness depending on the greenhouse insulation methods. RDA. http://blog.naver.com/hyjjung?Redirect=Log&logNo=140066786847 (in Korea). assessed September 11, 2010 (In Korean).
  7. Kwon, J. K., J. H. Lee, N. J. Kang, K. H. Kang and Y. H. Choi. 2004. Effects of covering materials and methods on heat insulation of a plastic greenhouse and growth and yield of tomato. Journal of Bio-Environment Control 13(4):251-257 (In Korean).
  8. Lee, S. Y., H. J. Kim, H. Chun, S. H. Yum and H. J. Lee. 2007. Comparison of heat insulation characteristics of multilayer thermal screen and development of curtain system. Journal of Bio-Environment Control 16(2): 89-95 (In Korean).

Cited by

  1. Evaluation of Overall Heat Transfer Coefficient of Different Greenhouse Thermal Screens Using Building Energy Simulation vol.27, pp.4, 2018, https://doi.org/10.12791/KSBEC.2018.27.4.294