• Title/Summary/Keyword: Multi-stacked

Search Result 163, Processing Time 0.02 seconds

Prediction of Residual Stress Distribution in Multi-Stacked Thin Film by Curvature Measurement and Iterative FEA

  • Choi Hyeon Chang;Park Jun Hyub
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.1065-1071
    • /
    • 2005
  • In this study, residual stress distribution in multi-stacked film by MEMS (Micro-Electro Mechanical System) process is predicted using Finite Element method (FEM). We evelop a finite element program for residual stress analysis (RESA) in multi-stacked film. The RESA predicts the distribution of residual stress field in multi-stacked film. Curvatures of multi­stacked film and single layers which consist of the multi-stacked film are used as the input to the RESA. To measure those curvatures is easier than to measure a distribution of residual stress. To verify the RESA, mean stresses and stress gradients of single and multi layers are measured. The mean stresses are calculated from curvatures of deposited wafer by using Stoney's equation. The stress gradients are calculated from the vertical deflection at the end of cantilever beam. To measure the mean stress of each layer in multi-stacked film, we measure the curvature of wafer with the left film after etching layer by layer in multi-stacked film.

Comparison Magnetization Losses of the multi-stacked YBCO Coated conductor and the BSCCO tapes (YBCO CC와 BSCCO Tape의 적층에 따른 자화손실 특성비교)

  • Lim Hyoungwoo;Lee Heejoon;Cha Gueesoo;Lee Ji-Kwang
    • Progress in Superconductivity and Cryogenics
    • /
    • v.7 no.3
    • /
    • pp.13-16
    • /
    • 2005
  • Multi-stacked HTS tapes are needed to conduct large current in the power application. In this paper magnetization losses of the multi-stacked YBCO coated conductor and the BSCCO tape have been measured and compared. Magnetization losses of single tape, 2-stacked, 3-stacked and 4-stacked HTS tapes have been presented in this paper. Multi-stacked tapes have been fabricated using face-to-face type stacking method. Measurements of magnetization loss were performed under various stacked of external magnetic field to consider the anisotropic characteristics of HTS tapes. Test results show that loss density per unit volume decreased for both YBCO coated conductors and BSCCO tapes when the stacking number of tapes is increased. As the external magnetic field decreased, the ratio of decrement has risen because the full penetration magnetic field(Bp) of the multi-stacked tape is larger than that of the single tape.

The Magnetization Losses Characteristics of Multi-stacked and Variable Angle of External Magnet Field in YBCO CC and BSCCO tape (YBCO Coated Conducor와 BSCCO tape의 적층 및 외부자장의 각도에 따른 자화손실 특성)

  • Lim, Hyoung-Woo;Lee, Hee-Joon;Cha, Guee-Soo
    • Progress in Superconductivity and Cryogenics
    • /
    • v.7 no.3
    • /
    • pp.34-38
    • /
    • 2005
  • Multi-stacked HTS tapes are needed to conduct large current in the power application. In this paper, magnetization losses of the multi-stacked YBCO coated conductor and the BSCCO tape have been measured and compared. Magnetization losses of single tape, 2-stacked, 3-stacked and 4-stacked HTS tapes have been presented in this paper. Multi-stacked tapes have been fabricated using face-to-face type stacking method. Measurements of magnetization loss were performed under various angle of external magnetic field to consider the anisotropic characteristics of HTS tapes. Test results show that loss density per unit volume decreased for both YBCO coated conductors and BSCCO tapes when the stacking number of tapes is increased. The magnetization losses of YBCO CC are larger than those of BSCCO tapes when the external magnetic field is increased.

Characteristics of AC loss of Hybrid Multi-Stacking with HTS Wires in External Magnetic Field (고온초전도 혼합적층선재의 외부자장 변화에 따른 손실 특설)

  • Lim, Hyoung-Woo;Lee, Dong-Min;Yun, Ki-Hyun;Cha, Guee-Soo;Lee, Hee-Joon
    • Proceedings of the KIEE Conference
    • /
    • 2006.10d
    • /
    • pp.71-73
    • /
    • 2006
  • AC loss on variation of external magnetic field is a very important factor in development of power applications. In this paper, we measured and compared AC loss of hybrid-multi stacked wire made of the combination of 1G wires and 2G wires and uniform-multi-stacked wire made of one type of wires, 1G wires or 2G wires. Measurement was performed using by the linked-picked coil method. As results, as the number of wires increase, AC loss per unit volume of both stacked wires in low external magnetic field is reduced. Also AC loss of 2G slacked wire is higher than that of 1G wire. AC loss per unit length of 2G stacked wire is less than that of 1G stacked wire. And AC loss of hybrid-multi stacked wire made of the combination of 1G wires and 2G wires was between uniform-multi-stacked wire made of 1G wires and 2G wires.

  • PDF

Characteristics of the HTS Stacked Tapes and AC Losses of the Multi-Stacked Pancake Coil (고온초전도 적층선재의 특성과 적층선재로 제작한 팬케이크 권선 손실)

  • Lee Seungwook;Lim Hyoungwoo;Cha Gueesoo;Lee Jikwang
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.11
    • /
    • pp.658-663
    • /
    • 2004
  • According to the improvement of the HTS wires performance, several tapes of HTS superconducting machines are being developed. Stacked HTS tapes are used as conductor that can flow high current for the HTS power machines. To develop the HTS power machines, the critical current characteristics of a stacked HTS tapes in external filed and AC losses should be examined. In this paper, we present characteristic of the stacked HTS tapes and AC losses of HTS pancake windings with stacked tapes. AC loss of the pancake winding were measured and compared with the calculated loss by using AC loss data of the stacked samples and the magnetic flux density in the HTS winding under operating conditions. We can see that measured results generally agree well with the calculated results by using AC loss data of 4-stacked sample.

Critical current characteristic of various 2G HTS multi-stacked tapes depending on the low external magnetic field

  • Kim, J.;Lee, W.S.;Jin, H.;Ko, T.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.16 no.1
    • /
    • pp.27-31
    • /
    • 2014
  • 2G HTS tapes are widely used for various electric machines. In addition, stacked or parallel connected HTS tapes are essentially used to raise transport current level for large capacity electric machines. Therefore, critical current characteristic of stacked tapes need to be studied. Recently developed 2G HTS tapes are fabricated with various defects doping so that tapes possess pinning center to improve the critical current characteristic. During this process, the critical current is determined minimum value in not perpendicular magnetic field but a specific magnetic field angle according to the reported research. However, the effects of magnetic field angle to critical current of multi-stacked 2G HTS tapes have not been examined. In this paper, field coil which is a race-track coil wound by using an HTS tape with iron-core was fabricated to apply angle adjustable magnetic field to the 2G HTS tape samples. We measured critical current of single and multi-stacked two tapes that have different characteristic depending on various magnetic field angle and magnitude in liquid nitrogen environment. Furthermore, results of single and multi-stacked tapes were compared and analyzed.

Comparison of Magnetization loss of YBCO wires and BSCCO Wires

  • Lim Hyoung-Woo;Lee Hee-Joon;Cha Guee-Soo;Lee Ji-Kwang
    • Progress in Superconductivity and Cryogenics
    • /
    • v.8 no.2
    • /
    • pp.33-36
    • /
    • 2006
  • Multi-stacked HTS wires are needed to conduct large current in the power application. In this paper, magnetization losses of the multi-stacked YBCO wire and the BSCCO wire have been measured and compared. 4 types of YBCO wires and BSCCO wires, that is, single, 2-stacked, 3-stacked and 4-stacked, have been tested. HTS multi-stacked wires were fabricated using face-to-face type stacking method. Measurements of magnetization loss were performed under various angles of external magnetic field to consider the anisotropic characteristics of HTS wires. The ratios of the magnetization loss by multiple stacking of superconducting wires were presented. Measurements results show that loss reduction ratios have three distinct regions due to the magnitude of external magnetic field, the material of HTS wire and number of stacks.

Effects of the insulation thickness on the magnetization loss of the multi-stacked YBCO coated conductor (절연거리 변화에 따른 적층된 YBCO 도체의 자화손실 변화)

  • Lim, Hyoung-Woo;Lee, Hee-Joon;Cha, Guee-Soo;Lee, Ji-Kwang
    • Proceedings of the KIEE Conference
    • /
    • 2005.10c
    • /
    • pp.95-97
    • /
    • 2005
  • Loss in the multi-stacked HTS wires are affected by a number of factor, such as, number of wires used in the stack, direction of external magnetic field and insulation thickness between the wire. This paper examines the effects of the insulation thickness on the magnetization loss of the multi-stacked YBCO coated conductor. Measurements of magnetization loss were performed using 4 different typo of multi-stacked wires and under various angle of external magnetic field. Test results show that loss density per unit volume increased for YBCO coated conductors when thickness of insulation increased. Loss density per unit volume decreased for YBCO coaled conductors when stacking number of tapes increased.

  • PDF

Effects of the External Magnetic field on the Critical Current and AC Loss of HTS Stacked Tapes

  • Lee, Seungwook;Hyoungwoo Lim;Park, Myeongseob;Lee, Heejoon;Gueesoo Cha;Lee, Jikwang
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.1
    • /
    • pp.87-91
    • /
    • 2003
  • According to the improvement of the HTS wires performance, several types of HTS superconducting machines are being developed. Stacked HTS tapes are used to conduct the current of the HTS power machines. To develop the HTS power machines, the critical current characteristics of a stacked HTS tapes in external field need be examined. In this paper, we present effect of the external magnetic field on the critical current of HTS stacked tapes. The critical current of various Hinds of multi-stacked HTS tapes in external magnetic filed are compare with that of a single HTS tape. Test results show that critical current of single HTS tape is smaller than that of multi-stacked HTS tape in the external field.

A Study on the Convective Heat Transfer in Micro Heat Exchanger Embedded in Stacked Multi-Chip Modules (적층형 Multi-Chip Module(MCM) 내부에 삽입된 초소형 열교환기 내에서의 대류 열전달 현상에 대한 연구)

  • Shin, Joong-Han;Kang, Moon-Koo;Lee, Woo-Il
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.6
    • /
    • pp.774-782
    • /
    • 2004
  • This article presents a numerical and experimental investigation for the single-phase forced laminar convective heat transfer through arrays of micro-channels in micro heat exchangers to be used for cooling power-intensive semiconductor packages, especially the stacked multi-chip modules. In the numerical analysis, a parametric study was carried out for the parameters affecting the efficiency of heat transfer in the flow of coolants through parallel rectangular micro-channels. In the experimental study, the cooling performance of the micro heat exchanger was tested on prototypes of stacked multi-chip modules with difference channel dimensions. The simulation results and the experiment data were acceptably accordant within a wide range of design variations, suggesting the numerical procedure as a useful method for designing the cooling mechanism in stacked multi-chip packages and similar electronic applications.