• 제목/요약/키워드: Multi-source CT

검색결과 12건 처리시간 0.022초

Photon-Counting Detector CT: Key Points Radiologists Should Know

  • Andrea Esquivel;Andrea Ferrero;Achille Mileto;Francis Baffour;Kelly Horst;Prabhakar Shantha Rajiah;Akitoshi Inoue;Shuai Leng;Cynthia McCollough;Joel G. Fletcher
    • Korean Journal of Radiology
    • /
    • 제23권9호
    • /
    • pp.854-865
    • /
    • 2022
  • Photon-counting detector (PCD) CT is a new CT technology utilizing a direct conversion X-ray detector, where incident X-ray photon energies are directly recorded as electronical signals. The design of the photon-counting detector itself facilitates improvements in spatial resolution (via smaller detector pixel design) and iodine signal (via count weighting) while still permitting multi-energy imaging. PCD-CT can eliminate electronic noise and reduce artifacts due to the use of energy thresholds. Improved dose efficiency is important for low dose CT and pediatric imaging. The ultra-high spatial resolution of PCD-CT design permits lower dose scanning for all body regions and is particularly helpful in identifying important imaging findings in thoracic and musculoskeletal CT. Improved iodine signal may be helpful for low contrast tasks in abdominal imaging. Virtual monoenergetic images and material classification will assist with numerous diagnostic tasks in abdominal, musculoskeletal, and cardiovascular imaging. Dual-source PCD-CT permits multi-energy CT images of the heart and coronary arteries at high temporal resolution. In this special review article, we review the clinical benefits of this technology across a wide variety of radiological subspecialties.

PET/CT 검사 환자의 피폭선량 경감을 위한 연구 (Research on the Reduction of Exposure Dose of a Patient Having a PET/CT Exam)

  • 김봉수;표성재;조용귀;신채호;조진우;김창호
    • 핵의학기술
    • /
    • 제13권3호
    • /
    • pp.10-16
    • /
    • 2009
  • 목적 : 환자의 피폭선량 감소를 위해 PET/CT검사 시Pitch를 조절하여 환자의 피폭선량을 줄일 수 있는 방법에 대해 고려해 보고 Pitch 조정이 CT 영상과 PET의 SUV값에 영향을 주어 변화가 있는지를 살펴 보고자 한다. 방법 : Siemens사의 Biograph Positron Emission Tomography (PET) Scanner (CT 형식 : TRCT-240-130 (WCT-240-130)을 사용하였다. 환자의 피폭선량 평가로는 CT 조사선량 측정기인 PTW-DIADOS 11003/1383를 사용하여 선량을 측정하였고 Pitch 조정이 CT 영상에 미치는 영향을 알아보기 위해 AAPM Standard Phantom을 이용하여 pitch 변화에 따른 CT 영상의 공간 분해능을 측정하여 비교하였다. 그리고, PET source consists of a solid radioactive cylinder phantom을 사용하여 Pitch 변화에 따른 Fusion 영상의 SUV값을 산출하여 PET/CT 영상에서 SUV값이 변하였는지 확인하였다. 결과 : 2slice CT scanner에서는 Pitch가 0.7~1.3까지는 방사선량이 크게 떨어지나 1.5~1.9까지는 방사선량의 감소가 작아졌으며 Pitch값이 커질수록 환자의 피폭선량이 작아지는 것을 알 수 있었다. 그리고 Pitch값의 증가에 따른 SUV값의 변화는 거의 없었으며. Pitch값이 PET SUV값에 영향을 주지 않는다는 것을 알 수 있었다. Pitch의 변화가 CT 영상에도 크게 영향을 주지 않는 것을 알 수 있었다. 결론 : 위의 결과로 PET/CT를 사용하는 병원은 영상의 왜곡이 없고 PET SUV값에 영향을 주지 않는 범위 내에서 각 병원에 맞는 Pitch값을 찾아서 환자의 피폭 경감을 위해 노력해야 할 것이다. 그리고 Multi-detector를 가진 CT scanner인 경우에 모두 해당 될 것이라 생각되며 향후 다른 장비에서도 이와 같은 실험이 필요하다 하겠다.

  • PDF

에너지 변조 필터를 이용한 이중 에너지 콘빔 CT의 선량 평가 (Evaluation of Radiation Dose for Dual Energy CBCT Using Multi-Grid Device)

  • 주은빈;안소현;조삼주;금기창;이레나
    • 한국의학물리학회지:의학물리
    • /
    • 제27권1호
    • /
    • pp.31-36
    • /
    • 2016
  • 본 연구에서는 이중에너지 영상을 획득하는 방법으로, 구리판을 이용한 에너지 변조 필터를 사용하였을 때의 선량을 계산 및 측정하였고, 기존의 다른 방법들과 선량을 비교하였다. 몬테칼로 전산모사를 이용하여 에너지 변조 필터에 의한 선량 변화를 평가하기 위하여 MCNPX를 사용하였다. 두경부, 흉부, 복부 촬영에 주로 사용되는 관전압인 80, 120 kVp에 대한 스펙트럼을 SPEC78 프로그램으로 생성하여 선원을 모사하였고, 구리 물질로 이루어진 에너지 변조 필터(밀도: $8.96g/cm^3$)는 두께를 0.5 mm부터 2.0 mm까지 0.5 mm 간격으로 변화시켜가면서 선원으로부터 20.0 cm 거리에 X-선 창을 절반만 가리도록 모델링 하였다. 몬테칼로 전산모사 값과 실제 선량 값을 비교하기 위해서는 교정 상수가 필요하므로, Gafchromic EBT3 필름에 알고 있는 선량을 조사한 후 판독하여 선량 교정 곡선을 획득하였다. 실험과 동일한 조건으로 MCNPX의 f6 tally로 획득한 결과값과 측정값 간의 선량 환산 인자는 $7.2*10^4cGy/output$으로 구해졌으며, 관전압 80 kVp과 관전류 6 mA의 조건으로 콘빔 CT 촬영 시, 평균 10.1 cGy (표준편차 2.7 cGy) 조사됨을 알 수 있었다. 에너지 변조 필터에 기반한 이중 에너지 영상 획득 기술을 적용한 본 연구에서는 이중 에너지 콘빔 CT 시스템의 선량이 단일 에너지 CT 시스템의 선량보다 33~40% 감소함을 알 수 있다. 또한, 에너지 변조 필터에서 발생한 산란선에 의한 선량 증가 효과는 거의 없었다. 따라서, 인체 내 물질 분별력이 우수하여 임상에 널리 응용되었던 기존 이중 에너지 CT 시스템의 상대적으로 피폭선량이 높다는 단점을 효과적으로 개선할 수 있다.

영상유도 양성자치료를 위한 콘빔 CT 재구성 알고리즘: 기하학적 보정방법에 관한 연구 (Geometric Calibration of Cone-beam CT System for Image Guided Proton Therapy)

  • 김진성;조민국;조영빈;윤한빈;김호경;윤명근;신동호;이세병;이레나;박성용;조관호
    • 한국의학물리학회지:의학물리
    • /
    • 제19권4호
    • /
    • pp.209-218
    • /
    • 2008
  • IMRT, 양성자 치료와 같이 방사선 치료 기술이 발전할수록 치료 시 환자의 위치를 확인하고 그 정확성을 평가하는 기술의 중요성이 강조되고 있다. 현재 국립암센터 양성자치료센터에 설치되어 있는 양성자 치료기의 단순 X-선 영상시스템을 이용하여 콘빔 CT (cone-beam CT) 3차원 영상을 획득, 영상유도 방사선 치료의 가능성을 확인하고자 하였다. 양성자 치료기에 설치되어있는 X-선 영상시스템(SDD: 2,108 mm, SOD: 1,511 mm, Varian a277 x-ray tube & Varian Paxscan 4030: a-Si+DRZ screen)을 이용하여 양성자 갠트리를 $2^{\circ}$씩 회전시켜가면서 기하학적인 오차 측정을 위한 팬톰과 인체 팬톰 (Humanoid phantom, Rando, CA, USA)의 투사영상을 획득하였다. 현재 시스템적으로 연속적인 회전과 영상획득이 지원되지 않아서 영상획득 후 갠트리를 회전하는 방법으로 투사영상을 획득하였다. 기하학적 오차측정을 위한 팬텀과 두경부 팬텀에 대해서 $360^{\circ}$를 회전하며 180장의 투사영상($2,304{\times}3,200$, 14 bit with 127${\mu}m$ pixel pitch)을 관전압 85 kVp, 관전류 80 mA, 조사시간 0.5 s의 조건으로 촬영하였다. 콘빔 CT 영상재구성을 위해 Ram-Lak filter를 적용한 Feldkamp cone-beam 알고리즘을 사용하였으며, 획득한 180장의 투사영상을 사용하여 $0.4{\times}0.4{\times}0.4mm^3$의 voxel size를 가진 $512{\times}512{\times}512$ CT영상을 재구성하였다. 기하학적인 오차 측정방법을 통해 X-선 선원, 검출기와 갠트리의 기하학적 정보를 측정하였다. 측정된 결과에 의하면 검출기가 $0.25^{\circ}$ 회전된 오차를 보이는 것을 발견하였다. 기하학적 교정으로 재구성된 콘빔 CT 영상을 multi-planar view (axial, sagittal and coronal view) 및 3차원 영상으로 재구성하여 비교 평가 하였다. 현재 양성자치료기에 설치되어있는 단순 X-선 영상 시스템에서 기하학적 오차 측정을 위한 볼 팬텀을 이용하여 시스템의 오차를 측정하였다. 측정한 오차를 바탕으로 기하학적 교정을 통해서 두경부 및 복부 팬텀에 대한 3차원 영상인 콘빔 CT 영상들을 재구성하였다. 추후 연속적인 회전을 통한 영상획득이 가능하게 된다면, 보다 정확하고 신속한 영상재구성이 가능 하며 콘빔 CT가 영상유도 양성자 치료에 매우 유용할 것으로 사려된다.

  • PDF

Parallel Implementations of Digital Focus Indices Based on Minimax Search Using Multi-Core Processors

  • HyungTae, Kim;Duk-Yeon, Lee;Dongwoon, Choi;Jaehyeon, Kang;Dong-Wook, Lee
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제17권2호
    • /
    • pp.542-558
    • /
    • 2023
  • A digital focus index (DFI) is a value used to determine image focus in scientific apparatus and smart devices. Automatic focus (AF) is an iterative and time-consuming procedure; however, its processing time can be reduced using a general processing unit (GPU) and a multi-core processor (MCP). In this study, parallel architectures of a minimax search algorithm (MSA) are applied to two DFIs: range algorithm (RA) and image contrast (CT). The DFIs are based on a histogram; however, the parallel computation of the histogram is conventionally inefficient because of the bank conflict in shared memory. The parallel architectures of RA and CT are constructed using parallel reduction for MSA, which is performed through parallel relative rating of the image pixel pairs and halved the rating in every step. The array size is then decreased to one, and the minimax is determined at the final reduction. Kernels for the architectures are constructed using open source software to make it relatively platform independent. The kernels are tested in a hexa-core PC and an embedded device using Lenna images of various sizes based on the resolutions of industrial cameras. The performance of the kernels for the DFIs was investigated in terms of processing speed and computational acceleration; the maximum acceleration was 32.6× in the best case and the MCP exhibited a higher performance.

MDCT에서의 Convolution Kernel 종류에 따른 공간 영역 필터링의 영상 평가 (Evaluation to Obtain the Image According to the Spatial Domain Filtering of Various Convolution Kernels in the Multi-Detector Row Computed Tomography)

  • 이후민;유병규;권대철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제31권1호
    • /
    • pp.71-81
    • /
    • 2008
  • CT 영상은 커널의 종류와 재구성 방법에 따라 다양하게 나타나며, 관심 영역의 CT감약계수 및 노이즈는 정밀도에 영향을 준다. 커널의 종류에 따른 노이즈, 공간분해능 및 MTF를 측정하여 영상을 평가하였다. 다중채널CT 스캐너를 이용하여 팬텀 및 복부를 스캔 하였고, 커널은 B10(very smooth), B20(smooth), B30(medium smooth), B40(medium), B50(medium sharp), B60(sharp), B70(very sharp), B80(ultra sharp)으로 재구성하여 물, 공기, 간의 실질 조직, 근육, 지방 부위를 ROI 기능을 이용하여 평균의 CT감약계수와 표준편차인 노이즈를 정량적으로 측정하여 영상을 비교하였다. 그 결과CT 감약계수는 물($1.1{\sim}1.8\;HU$), 공기($-998{\sim}-1,000\;HU$)이고, 물에서의 노이즈($5.4{\sim}44.8\;HU$), 공기($3.6{\sim}31.4\;HU$)이다. 인체에서 간 실질 조직과 지방, 근육의 CT 감약계수와 노이즈를 커널에 따라 측정하였다. 지방의 CT 감약계수($-2.2{\sim}0.8\;HU$), 간의 실질 조직에서 CT감약계수($60.4{\sim}62.2\;HU$), 노이즈($7.6{\sim}63.8\;HU$), 근육의 CT감약계수($53.3{\sim}54.3\;HU$), 노이즈($10.4{\sim}70.7\;HU$) 사이에서 분포하였고, 커널이 높아질수록 노이즈도 증가하였다. 영상의 질을 높이기 위해서는 검사부위에 따라 노이즈를 감소하기 위해 적절한 커널을 선택하여 CT 검사를 하여야 한다.

  • PDF

Predictive model of fatigue crack detection in thick bridge steel structures with piezoelectric wafer active sensors

  • Gresil, M.;Yu, L.;Shen, Y.;Giurgiutiu, V.
    • Smart Structures and Systems
    • /
    • 제12권2호
    • /
    • pp.97-119
    • /
    • 2013
  • This paper presents numerical and experimental results on the use of guided waves for structural health monitoring (SHM) of crack growth during a fatigue test in a thick steel plate used for civil engineering application. Numerical simulation, analytical modeling, and experimental tests are used to prove that piezoelectric wafer active sensor (PWAS) can perform active SHM using guided wave pitch-catch method and passive SHM using acoustic emission (AE). AE simulation was performed with the multi-physic FEM (MP-FEM) approach. The MP-FEM approach permits that the output variables to be expressed directly in electric terms while the two-ways electromechanical conversion is done internally in the MP-FEM formulation. The AE event was simulated as a pulse of defined duration and amplitude. The electrical signal measured at a PWAS receiver was simulated. Experimental tests were performed with PWAS transducers acting as passive receivers of AE signals. An AE source was simulated using 0.5-mm pencil lead breaks. The PWAS transducers were able to pick up AE signal with good strength. Subsequently, PWAS transducers and traditional AE transducer were applied to a 12.7-mm CT specimen subjected to accelerated fatigue testing. Active sensing in pitch catch mode on the CT specimen was applied between the PWAS transducers pairs. Damage indexes were calculated and correlated with actual crack growth. The paper finishes with conclusions and suggestions for further work.

마이크로 프로세서에 의한 영구자석동기 전동기의 구동 (Microprocessor Based Permanent Magnet Synchronous Motor Drive)

  • Yoon, Byung-Do
    • 대한전기학회논문지
    • /
    • 제35권12호
    • /
    • pp.541-554
    • /
    • 1986
  • This paper presents the results of driving performance analysis of permanent magnet synchronous motor using a microprocessor based control system. The system consists of three phase power transistor inverters, three phase controlled rectifier, three central processing units, and sensors. The three CPUs are, respectively, used to generate PWM control signals for the inverter generating three phase sine wave, to generate the gate control signals for firing the converter, and to supervise other two CPUs. The supervisor is used to compute PI control algtorithm to three phase reference sine wave for the inverter. It is also used to maintain a constant voltage frequency ratio for the converter operating as a constant torque controller. The inverter CPU retrieves precomputed PWM patterns from look up tables because of computation speed limitations found in almost available microprocessors. The converter CPU also retrieves precomputed gate control patterns from another look-up tables. For protecting the control ststem from any damage by extraordinary over currents, the supervisor receives the data from current sensor, CT, and break down the CB to isolate the circuits from source. A resolver has a good performance characteristics of overall speed range, especially on low speed range. Therefor the speed control accuracy is impoved. The microprocessor based PM synchronous motor control system, thus, has many advantages such as constant torque characteristics, improvement of wave, limitation on extraordinary over currents, improvement of speed control accuracy, and fast response speed control using multi-CPU and look-up tables.

  • PDF

Geant4 전산모사 코드를 이용한 SBRT 환자의 선량분포 계산 (Calculation of Dose Distribution for SBRT Patient Using Geant4 Simulation Code)

  • 강정구;이정옥;이동준
    • 한국의학물리학회지:의학물리
    • /
    • 제26권1호
    • /
    • pp.36-41
    • /
    • 2015
  • 정위체부방사선수술(SBRT) 환자의 선량분포를 계산하기 위해 전산모사 방식을 이용한 응용프로그램을 개발 하였다. 본 소프트웨어는 최근 이용이 활발하게 증가하고 있는 Geant4를 기반으로 개발 하였다. 환자에 조사하기 위한 광자선 스펙트럼은 이전 연구에서 구한 선형가속기 스펙트럼 자료를 사용하였다. 치료계획시스템과 유사한 조사면을 구현하기 위하여 PrimaryGeneratorAction 클래스에서 MLC 조사면 형태를 반영하도록 하였다. 본 연구에서는 8개 조사면에 대한 계산을 수행하였으며 이 때 갠트리의 각도는 PrimaryGeneratorAction 클래스에서 회전 매트릭스를 사용하여 선원의 위치를 변경하는 방법을 사용하였다. 환자에 대한 물질 자료는 CT의 dicom 파일에서 픽셀 크기, 매트릭스 크기 등의 정보와 픽셀의 HU를 밀도로 변환한 파일을 생성한 다음 이 파일을 이용 환자의 모델링에 이용 하였다. 환자의 물질 구성과 기하학적 자료의 입력에 있어 EGSnrc 코드와의 비교를 통하여 계산의 효율성을 비교하였다.