Performance Characteristics of 3D GSO PET/CT Scanner (Philips GEMINI PET/DT) (3차원 GSO PET/CT 스캐너(Philips GEMINI PET/CT의 특성 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Byeong-Il;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.4
    • /
    • pp.318-324
    • /
    • 2004
  • Purpose: Philips GEMINI is a newly introduced whole-body GSO PET/CT scanner. In this study, performance of the scanner including spatial resolution, sensitivity, scatter fraction, noise equivalent count ratio (NECR) was measured utilizing NEMA NU2-2001 standard protocol and compared with performance of LSO, BGO crystal scanner. Methods: GEMINI is composed of the Philips ALLEGRO PET and MX8000 D multi-slice CT scanners. The PET scanner has 28 detector segments which have an array of 29 by 22 GSO crystals ($4{\times}6{\times}20$ mm), covering axial FOV of 18 cm. PET data to measure spatial resolution, sensitivity, scatter fraction, and NECR were acquired in 3D mode according to the NEMA NU2 protocols (coincidence window: 8 ns, energy window: $409[\sim}664$ keV). For the measurement of spatial resolution, images were reconstructed with FBP using ramp filter and an iterative reconstruction algorithm, 3D RAMLA. Data for sensitivity measurement were acquired using NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves after we confirmed that dead time loss did not exceed 1%. To measure NECR and scatter fraction, 1110 MBq of F-18 solution was injected into a NEMA scatter phantom with a length of 70 cm and dynamic scan with 20-min frame duration was acquired for 7 half-lives. Oblique sinograms were collapsed into transaxial slices using single slice rebinning method, and true to background (scatter+random) ratio for each slice and frame was estimated. Scatter fraction was determined by averaging the true to background ratio of last 3 frames in which the dead time loss was below 1%. Results: Transverse and axial resolutions at 1cm radius were (1) 5.3 and 6.5 mm (FBP), (2) 5.1 and 5.9 mm (3D RAMLA). Transverse radial, transverse tangential, and axial resolution at 10 cm were (1) 5.7, 5.7, and 7.0 mm (FBP), (2) 5.4, 5.4, and 6.4 mm (3D RAMLA). Attenuation free values of sensitivity were 3,620 counts/sec/MBq at the center of transaxial FOV and 4,324 counts/sec/MBq at 10 cm offset from the center. Scatter fraction was 40.6%, and peak true count rate and NECR were 88.9 kcps @ 12.9 kBq/mL and 34.3 kcps @ 8.84 kBq/mL. These characteristics are better than that of ECAT EXACT PET scanner with BGO crystal. Conclusion: The results of this field test demonstrate high resolution, sensitivity and count rate performance of the 3D PET/CT scanner with GSO crystal. The data provided here will be useful for the comparative study with other 3D PET/CT scanners using BGO or LSO crystals.

Fixed Time Synchronous IPC in Zephyr Kernel (Zephyr 커널에서 고정 시간 동기식 IPC 구현)

  • Jung, Jooyoung;Kim, Eunyoung;Shin, Dongha
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.12 no.4
    • /
    • pp.205-212
    • /
    • 2017
  • Linux Foundation has announced a real-time kernel, called Zephyr, for IoT applications recently. Zephyr kernel provides synchronous and asynchronous IPC for data communication between threads. Synchronous IPC is useful for programming multi-threads that need to be executed synchronously, since the sender thread is blocked until the data is delivered to the receiver thread and the completion of data transfer can be known to two threads. In general, 'IPC execution time' is defined as the time duration between the sender thread sends data and the receiver thread receives the data sent. Especially, it is important that 'IPC execution time' in the synchronous IPC should be fixed in real-time kernel like Zephyr. However, we have found that the execution time of the synchronous IPC in Zephyr kernel increases in proportion to the number of threads executing in the kernel. In this paper, we propose a method to implement a fixed time synchronous IPC in Zephyr kernel using Direct Thread Switching(DTS) technique. Using the technique, the receiver thread executes directly after the sender thread sends a data during the remaining time slice of the sender thread and we can archive a fixed IPC execution time even when the number of threads executing in the kernel increases. In this paper, we implemented synchronous IPC using DTS in the Zephyr kernel and found the IPC execution time of the IPC is always 389 cycle that is relatively small and fixed.

Total Arterial 011-Pump Coronary Revascularization with Multiple Y Arterial Composite Grafts (다중 복합 Y 동맥 이식편(Multiple Y Composite Craft)을 이용한 완저너 동맥 무인공 심폐바이패스 관상동맥우회술)

  • Kim Do-kyun;Lee Kyo Jgon;Joo Hyun Chul;Li Gyjong;Ahn Jiyoung;shim Yungee;Yoo Kyung Jong
    • Journal of Chest Surgery
    • /
    • v.38 no.8 s.253
    • /
    • pp.551-556
    • /
    • 2005
  • Background: Complete arterial off-pump coronary artery bypass grafting (OPCAB) by sequential anastomoses with one or two arterial grafts provides favorable outcomes. However, problems of insufficient graft length, hypopefusion, kinking of graft, and unfavorable course of graft may be encountered. To solve these problems, we have used different technique with multiple arterial Y composite graft to allow end-to-side rather than sequential anastomoses and evaluated the results of this method. Material and Method: Between February 2003 and October 2004, If patients underwent total arterial OPCAB using multiple arterial V composite grafts with left internal mammary artery (LIMA), radial artery (RA), and right internal mammary artery (RIMA). We divided RA into multiple segments by number of distal target site after measuring of individual proper length and constructed arterial composite graft. One of segments was sutured end-to-side to LIMA and other segment was sutured end-to-side to the previously constructed radial graft. Postoperative graft patency was evaluated in 6f patients by multi-slice computed tomegraphy. Result: An average of $2.5\pm0.6$ arteries and $3.7pm0.7$ distal anastomoses per patient were done. There was no perioperative myocardial infarction, clinical hypoperfusion syndromes, and operative mortality. Postoperative mean CK-MB level was $17.4pm29.7\;IU/L.$Overall graft patency was $99.1\%\;(214/216)(LIMA:\;100\%,\;RA:\;98.4\%,\;RIMA:\;100\%).$ Conclusion: This technique allows total arterial OPCAB without technical problems and provides excellent early clinical results and graft patency. We believe that this technique is more convenient in the obtuse marginal area compared to sequential technique, and helpful in patients who require complex arterial grafting.

The Clinical Outcomes of Off-Pump Coronary Artery Bypass Grafting in the Octogenarians (80세 이상 고령 환자에서 심폐바이패스 없이 시행한 관상동맥우회술의 중단기 성적)

  • Kim Do-Kyun;Lee Chang Young;Lee Kyo Joon;Joo Hyun Chul;Yoo Kyung-Jong
    • Journal of Chest Surgery
    • /
    • v.38 no.10 s.255
    • /
    • pp.680-684
    • /
    • 2005
  • Background: With the increasing age of the population, coronary artery bypass grafting in the elderly patients is becoming common. Off-pump coronary artery bypass grafting (OPCAB) has been proven to be less morbidity and to facilitate early recovery. The elderly patients may have benefits by avoiding the adverse effects of the cardiopulmonary bypass. The purpose of this study is to evaluate our results of OPCAB in elderly patients. Material and Method: A retrospective chart review was carried out for 12 patients aged over 80 years who underwent isolated OPCAB from January 2001 and March 2004. Data were collected risk factors for disease, extent of coronary disease, and in-hospital outcomes. Postoperative graft patiency was evaluated in 9 patients by multi-slice computed tomography. Result: Eleven patients had triple vessel disease or left main disease. Four patients were suffered from preoperative CVA, and 4 patients had chronic obstructive pulmonary disease. Two patients had myocardial infarction (MI), among them 1 patient was suffered from pulmonary edema after preoperative MI. There was no perioperative death, perioperative MI, and no ventricular arrhythmia. Also there was no perioperative stroke and renal failure. But there was one deep sternal infection who recovered by treating of muscle flap. Atrial fibrillation was newly developed in 1 patient, but was well controlled by medication. Mean intubation time was $15.9\pm4.4(8\~20hrs)$ hrs and mean ICU stay was $2.9\pm0.8(2\~4 days)$ days. Mean hospital day was $21.6\pm14.3(13\~56 days)$ days. Postoperative mean CK-MS was $11.3\pm14.1\;ng/mL$. Early postoperative graft patency rate was $100\%(24/24)$. Follow-up was completed in all patients. In this time, there was no patients with angina or death. Conclusion: The results of this study suggest that OPCAB reduces morbidity and favors hospital outcomes. Therefore, OPCAB is safe, reasonable and might be preferable operative strategy in elderly patients.

Comparison of Left Ventricular Volume and Function between 46 Channel Multi-detector Computed Tomography (MDCT) and Echocardiography (16 채널 Multi-detector 컴퓨터 단층촬영과 심초음파를 이용한 좌심실 용적과 기능의 비교)

  • Park, Chan-Beom;Cho, Min-Seob;Moon, Mi-Hyoung;Cho, Eun-Ju;Lee, Bae-Young;Kim, Chi-Kyung;Jin, Ung
    • Journal of Chest Surgery
    • /
    • v.40 no.1 s.270
    • /
    • pp.45-51
    • /
    • 2007
  • Background: Although echocardiography is usually used for quantitative assessment of left ventricular function, the recently developed 16-slice multidetector computed tomography (MDCT) is not only capable of evaluating the coronary arteries but also left ventricular function. Therefore, the objective of our study was to compare the values of left ventricular function quantified by MDCT to those by echocardiography for evaluation of its regards to clinical applications. Material and Method: From 49 patients who underwent MDCT in our hospital from November 1, 2003 to January 31, 2005, we enrolled 20 patients who underwent echocardiography during the same period for this study. Left ventricular end-diastolic volume index (LVEDVI), left ventricular end-systolic volume index (LVESVI), stroke volume index (SVI), left ventricular mass index (LVMI), and ejection fraction (EF) were analyzed. Result: Average LVEDVI ($80.86{\pm}34.69mL$ for MDCT vs $60.23{\pm}29.06mL$ for Echocardiography, p<0.01), average LVESVI ($37.96{\pm}24.52mL$ for MDCT vs $25.68{\pm}16.57mL$ for Echocardiography, p<0.01), average SVI ($42.90{\pm}15.86mL$ for MDCT vs $34.54{\pm}17.94mL$ for Echocardiography, p<0.01), average LVMI ($72.14{\pm}25.35mL$ for MDCT vs $130.35{\pm}53.10mL$ for Echocardiography, p<0.01), and average EF ($55.63{\pm}12.91mL$ for MOCT vs $59.95{\pm}12.75ml$ for Echocardiography, p<0.05) showed significant difference between both groups. Average LVEDVI, average LVESVI, and average SVI were higher in MDCT, and average LVMI and average EF were higher in echocardiogram. Comparing correlation for each parameters between both groups, LVEDVI $(r^2=0.74,\;p<0.0001)$, LVESVI $(r^2=0.69,\;p<0.0001)$ and SVI $(r^2=0.55,\;p<0.0001)$ showed high relevance, LVMI $(r^2=0.84,\;p<0.0001)$ showed very high relevance, and $EF (r^2=0.45,\;p=0.0002)$ showed relatively high relevance. Conclusion: Quantitative assessment of left ventricular volume and function using 16-slice MDCT showed high relevance compared with echocardiography, therefore may be a feasible assessment method. However, because the average of each parameters showed significant difference, the absolute values between both studies may not be appropriate for clinical applications. Furthermore, considering the future development of MDCT, we expect to be able to easily evaluate the assessment of coronary artery stenosis along with left ventricular function in coronary artery disease patients.

Higher Order Shimming for Ultra-fast Spiral-Scan Imaging at 3 Tesla MRI System (3 Tesla MRI 시스템에서 초고속 나선주사영상을 위한 고차 shimming)

  • Kim, P.K.;Lim, J.W.;Ahn, C.B.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.11 no.2
    • /
    • pp.95-102
    • /
    • 2007
  • Purpose: To acquire high-resolution spiral-scan images at higher magnetic field, high homogeneous magnetic field is needed. Field inhomogeneity mapping and in-vivo shimming are important for rapid imaging such as spiral-scan imaging. The rapid scanning sequences are very susceptible to inhomogeneity. In this paper, we proposed a higher-order shimming method to obtain homogeneous magnetic field. Materials and Methods: To reduce measurement time for field inhomogeneity mapping, simultaneous axial/ sagittal, and coronal acquisitions are done using multi-slice based Fast Spin echo sequence. Acquired field inhomogeneity map is analyzed using the spherical harmonic functions, and shim currents are obtained by the multiplication of the pseudo-inverse of the field pattern with the inhomogeneity map. Results: Since the field inhomogeneity is increasing in proportion to the magnetic field, higher order shimming to reduce the inhomogeneity becomes more important in high field imaging. The shimming technique in which axial, sagittal, and coronal section inhomogeneity maps are obtained in one scan is developed, and the shimming method based on the analysis of spherical harmonics of the imhomogenity map is applied. The proposed technique is applicable to a localized shimming as well. High resolution spiral-scan imaging was successfully obtained with the proposed higher order shimming. Conclusion: Proposed pulse sequence for rapid measurement of inhomogeneity map and higher order shimming based on the inhomogeneity map work very well at 3 Tesla MRI system. With the proposed higher order shimming and localized higher order shimming techniques, high resolution spiral-scan images are successfully obtained at 3 T MRI system.

  • PDF

Off Pump Total Arterial Myocardial Revascularization (동맥 도관만을 이용하여 체외심폐순환 없이 시행한 관상동맥우회술)

  • Youn Young Nam;Lee Kyo Joon;Lee Gy Jong;Joo Hyun Chul;Lim Sang Hyun;Kim Seung Ho;Kwak Young Lan;Yoo Kyung Jong
    • Journal of Chest Surgery
    • /
    • v.38 no.5 s.250
    • /
    • pp.349-356
    • /
    • 2005
  • Background: Arterial conduits using in coronary artery bypass grafting (CABG) have been known a great long term patency rates, and improved short and long term clinical outcomes. It has been reported that Off pump CABG has better clinical results than CABG using cardiopulmonary bypass. To evaluate the advantage of arterial conduits over venous conduits and to avoid the adverse effects of cardiopulmonary bypass, we performed total arterial Off pump CABG. Material and Method: From January 2001 to October 2004, Off pump CABG using only arterial conduits was performed on 325 patients with a mean age of $59.3\pm11.9$ years ($36\~83$). Mean ejection fraction was $55.4\pm14.0\%\;(15\~86).$ Angiography showed left main disease or triple-vessel disease in $81.9\%$ of the patients. Indications of using arterial conduits was stenosis $\ge50\%$ of left anterior descending artery, stenosis $\ge80\%$ of branches of left circumflex artery, and stenosis $\ge90\%$ of right coronary artery and its branches. Multi-slice computed tomography was performed on 194 patients to evaluate the short term patency rates. Result: A total of 928 distal anastomoses were performed and the average anastomoses per a patient were $2.86\pm0.78$. There was 1 operative mortality. Postoperative complications were mediastinitis in 6 patients ($1.8\%$), renal failure in 4 patients ($1.2\%$), perioperative myocardial infarction in 3 patients ($0.9\%$), reoperation for bleeding in 3 patients ($0.9\%$). There was no postoperative stroke. Patency rate of arterial conduits was $99.3\%$ (581/585). There were 4 stenoses or competitive flows in 2 radial arteries and 2 right internal mammary arteries. Conclusion: Total arterial Off pump CABG appears to be safe, showing a low surgical mortality and morbidity and excellent short term patency rates of arterial conduits.

Local Shape Analysis of the Hippocampus using Hierarchical Level-of-Detail Representations (계층적 Level-of-Detail 표현을 이용한 해마의 국부적인 형상 분석)

  • Kim Jeong-Sik;Choi Soo-Mi;Choi Yoo-Ju;Kim Myoung-Hee
    • The KIPS Transactions:PartA
    • /
    • v.11A no.7 s.91
    • /
    • pp.555-562
    • /
    • 2004
  • Both global volume reduction and local shape changes of hippocampus within the brain indicate their abnormal neurological states. Hippocampal shape analysis consists of two main steps. First, construct a hippocampal shape representation model ; second, compute a shape similarity from this representation. This paper proposes a novel method for the analysis of hippocampal shape using integrated Octree-based representation, containing meshes, voxels, and skeletons. First of all, we create multi-level meshes by applying the Marching Cube algorithm to the hippocampal region segmented from MR images. This model is converted to intermediate binary voxel representation. And we extract the 3D skeleton from these voxels using the slice-based skeletonization method. Then, in order to acquire multiresolutional shape representation, we store hierarchically the meshes, voxels, skeletons comprised in nodes of the Octree, and we extract the sample meshes using the ray-tracing based mesh sampling technique. Finally, as a similarity measure between the shapes, we compute $L_2$ Norm and Hausdorff distance for each sam-pled mesh pair by shooting the rays fired from the extracted skeleton. As we use a mouse picking interface for analyzing a local shape inter-actively, we provide an interaction and multiresolution based analysis for the local shape changes. In this paper, our experiment shows that our approach is robust to the rotation and the scale, especially effective to discriminate the changes between local shapes of hippocampus and more-over to increase the speed of analysis without degrading accuracy by using a hierarchical level-of-detail approach.

Clinical Outcomes of Off-pump Coronary Artery Bypass Grafting (심폐바이패스 없는 관상동맥우회술의 임상성적)

  • Shin, Je-Kyoun;Kim, Jeong-Won;Jung, Jong-Pil;Park, Chang-Ryul;Park, Soon-Eun
    • Journal of Chest Surgery
    • /
    • v.41 no.1
    • /
    • pp.34-40
    • /
    • 2008
  • Background: Off-pump coronary artery bypass grafting (OPCAB) shows fewer side effects than cardiopulmonary by. pass, and other benefits include myocardial protection, pulmonary and renal protection, coagulation, inflammation, and cognitive function. We analyzed the clinical results of our cases of OPCAB. Material and Method: From May 1999 to August 2007, OPCAB was performed in 100 patients out of a total of 310 coronary artery bypass surgeries. There were 63 males and 37 females, from 29 to 82 years old, with a mean age of $62{\pm}10$ years. The preoperative diagnoses were unstable angina in 77 cases, stable angina in 16, and acute myocardial infarction in 7. The associated diseases were hypertension in 48 cases, diabetes in 42, chronic renal failure in 10, carotid artery disease in 6, and chronic obstructive pulmonary disease in 5. The preoperative cardiac ejection fraction ranged from 26% to 74% (mean $56.7{\pm}11.6%$). Preoperative angiograms showed three-vessel disease in 47 cases, two-vessel disease in 25, one-vessel disease in 24, and left main disease in 23. The internal thoracic artery was harvested by the pedicled technique through a median sternotomy in 97 cases. The radial artery and greater saphenous vein were harvested in 70 and 45 cases, respectively (endoscopic harvest in 53 and 41 cases, respectively). Result: The mean number of grafts was $2.7{\pm}1.2$ per patient, with grafts sourced from the unilateral internal thoracic artery in 95 (95%) cases, the radial artery in 62, the greater saphenous vein in 39, and the bilateral internal thoracic artery in 2. Sequential anastomoses were performed in 46 cases. The anastomosed vessels were the left anterior descending artery in 97 cases, the obtuse marginal branch in 63, the diagonal branch in 53, the right coronary artery in 30, the intermediate branch in 11, the posterior descending artery in 9 and the posterior lateral branch in 3. The conversion to cardiopulmonary bypass occurred in 4 cases. Graft patency was checked before discharge by coronary angiography or multi-slice coronary CT angiography in 72 cases, with a patency rate of 92.9% (184/198). There was one case of mortality due to sepsis. Postoperative arrhythmias or myocardial in-farctions were not observed. Postoperative complications were a cerebral stroke in 1 case and wound infection in 1. The mean time of respirator care was $20{\pm}35$ hours and the mean duration of stay in the intensive care unit was $68{\pm}47$ hours. The mean amounts of blood transfusion were $4.0{\pm}2.6$ packs/patient. Conclusion: We found good clinical outcomes after OPCAB, and suggest that OPCAB could be used to expand the use of coronary artery bypass grafting.